메뉴 건너뛰기




Volumn 42, Issue 11, 2013, Pages 1555-1563

Bilateral hip imaging at 7 Tesla using a multi-channel transmit technology: Initial results presenting anatomical detail in healthy volunteers and pathological changes in patients with avascular necrosis of the femoral head

Author keywords

7 Tesla; Avascular necrosis; AVN; B1 shimming; Hip; MRI

Indexed keywords

ADULT; ARTICLE; AVASCULAR NECROSIS; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC IMAGING; DIAGNOSTIC IMAGING EQUIPMENT; FEMALE; FEMUR HEAD NECROSIS; HIP RADIOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE PROCESSING; IMAGE QUALITY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGICAL ANATOMY; PRIORITY JOURNAL;

EID: 84885419824     PISSN: 03642348     EISSN: 14322161     Source Type: Journal    
DOI: 10.1007/s00256-013-1698-0     Document Type: Article
Times cited : (28)

References (33)
  • 1
    • 33744799176 scopus 로고    scopus 로고
    • Musculoskeletal MR imaging at 3.0 T: Current status and future perspectives
    • 16541224 10.1007/s00330-006-0184-7
    • Bolog N, Nanz D, Weishaupt D. Musculoskeletal MR imaging at 3.0 T: current status and future perspectives. Eur Radiol. 2006;16(6):1298-307.
    • (2006) Eur Radiol , vol.16 , Issue.6 , pp. 1298-1307
    • Bolog, N.1    Nanz, D.2    Weishaupt, D.3
  • 2
    • 64649090409 scopus 로고    scopus 로고
    • First clinical study on ultra-high-field MR imaging in patients with multiple sclerosis: Comparison of 1.5T and 7T
    • 19147714 10.3174/ajnr.A1434 1:STN:280:DC%2BD1M3mt12luw%3D%3D
    • Kollia K, Maderwald S, Putzki N, Schlamann M, Theysohn JM, Kraff O, et al. First clinical study on ultra-high-field MR imaging in patients with multiple sclerosis: comparison of 1.5T and 7T. AJNR Am J Neuroradiol. 2009;30(4):699-702.
    • (2009) AJNR Am J Neuroradiol , vol.30 , Issue.4 , pp. 699-702
    • Kollia, K.1    Maderwald, S.2    Putzki, N.3    Schlamann, M.4    Theysohn, J.M.5    Kraff, O.6
  • 4
    • 33846785601 scopus 로고    scopus 로고
    • Ultra-high-field MRI of the musculoskeletal system at 7.0T
    • 17260399 10.1002/jmri.20814
    • Regatte RR, Schweitzer ME. Ultra-high-field MRI of the musculoskeletal system at 7.0T. J Magn Reson Imaging. 2007;25(2):262-9.
    • (2007) J Magn Reson Imaging , vol.25 , Issue.2 , pp. 262-269
    • Regatte, R.R.1    Schweitzer, M.E.2
  • 5
    • 34447341182 scopus 로고    scopus 로고
    • High-field-strength magnetic resonance: Potential and limits
    • 17621228 10.1097/RMR.0b013e3180f612b3
    • Ladd ME. High-field-strength magnetic resonance: potential and limits. Topics in magnetic resonance imaging: TMRI. 2007;18(2):139-52.
    • (2007) Topics in Magnetic Resonance Imaging: TMRI , vol.18 , Issue.2 , pp. 139-152
    • Ladd, M.E.1
  • 9
    • 84864694054 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the knee at 3 and 7 Tesla: A comparison using dedicated multi-channel coils and optimised 2D and 3D protocols
    • Welsch GH, Juras V, Szomolanyi P, Mamisch TC, Baer P, Kronnerwetter C, et al. Magnetic resonance imaging of the knee at 3 and 7 Tesla: a comparison using dedicated multi-channel coils and optimised 2D and 3D protocols. Eur Radiol. 2012.
    • (2012) Eur Radiol
    • Welsch, G.H.1    Juras, V.2    Szomolanyi, P.3    Mamisch, T.C.4    Baer, P.5    Kronnerwetter, C.6
  • 10
    • 44449139521 scopus 로고    scopus 로고
    • Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion
    • 18421685 10.1002/jmri.21164
    • Franklin KM, Dale BM, Merkle EM. Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion. J Magn Reson Imaging. 2008;27(6):1443-7.
    • (2008) J Magn Reson Imaging , vol.27 , Issue.6 , pp. 1443-1447
    • Franklin, K.M.1    Dale, B.M.2    Merkle, E.M.3
  • 11
    • 34548714118 scopus 로고    scopus 로고
    • Perspectives on body MR imaging at ultrahigh field
    • 17893062 10.1016/j.mric.2007.07.001 viii
    • Hecht EM, Lee RF, Taouli B, Sodickson DK. Perspectives on body MR imaging at ultrahigh field. Magn Reson Imaging Clin N Am. 2007;15(3):449-65. viii.
    • (2007) Magn Reson Imaging Clin N Am , vol.15 , Issue.3 , pp. 449-465
    • Hecht, E.M.1    Lee, R.F.2    Taouli, B.3    Sodickson, D.K.4
  • 12
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • 17622966 10.1002/jmri.20969
    • Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging. 2007;26(2):375-85.
    • (2007) J Magn Reson Imaging , vol.26 , Issue.2 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Reiser, M.F.4    Schoenberg, S.O.5
  • 13
    • 84866293743 scopus 로고    scopus 로고
    • Simultaneous bilateral hip joint imaging at 7 Tesla using fast transmit B(1) shimming methods and multichannel transmission - A feasibility study
    • Ellermann J, Goerke U, Morgan P, Ugurbil K, Tian J, Schmitter S, et al. Simultaneous bilateral hip joint imaging at 7 Tesla using fast transmit B(1) shimming methods and multichannel transmission - a feasibility study. NMR Biomed. 2012.
    • (2012) NMR Biomed
    • Ellermann, J.1    Goerke, U.2    Morgan, P.3    Ugurbil, K.4    Tian, J.5    Schmitter, S.6
  • 14
    • 84865343927 scopus 로고    scopus 로고
    • New look at renal vasculature: 7 Tesla nonenhanced T1-weighted FLASH imaging
    • 22649028 10.1002/jmri.23702 1:STN:280:DC%2BC38nns1arsg%3D%3D
    • Umutlu L, Maderwald S, Kraff O, Kinner S, Schaefer LC, Wrede K, et al. New look at renal vasculature: 7 Tesla nonenhanced T1-weighted FLASH imaging. J Magn Reson Imaging. 2012;36(3):714-21.
    • (2012) J Magn Reson Imaging , vol.36 , Issue.3 , pp. 714-721
    • Umutlu, L.1    Maderwald, S.2    Kraff, O.3    Kinner, S.4    Schaefer, L.C.5    Wrede, K.6
  • 15
    • 84867271608 scopus 로고    scopus 로고
    • Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7.0T: Implications for clinical imaging
    • 22653280 10.1007/s00330-012-2487-1
    • Winter L, Kellman P, Renz W, Grassl A, Hezel F, Thalhammer C, et al. Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7.0T: implications for clinical imaging. Eur Radiol. 2012;22(10):2211-20.
    • (2012) Eur Radiol , vol.22 , Issue.10 , pp. 2211-2220
    • Winter, L.1    Kellman, P.2    Renz, W.3    Grassl, A.4    Hezel, F.5    Thalhammer, C.6
  • 20
    • 78650133011 scopus 로고    scopus 로고
    • An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T
    • 21302794 10.1118/1.3517176
    • Kraff O, Bitz AK, Dammann P, Ladd SC, Ladd ME, Quick HH. An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T. Med Phys. 2010;37(12):6368-76.
    • (2010) Med Phys , vol.37 , Issue.12 , pp. 6368-6376
    • Kraff, O.1    Bitz, A.K.2    Dammann, P.3    Ladd, S.C.4    Ladd, M.E.5    Quick, H.H.6
  • 23
    • 34250783171 scopus 로고    scopus 로고
    • Magnetic-field-induced vertigo: A theoretical and experimental investigation
    • 17427890 10.1002/bem.20316 1:STN:280:DC%2BD2szksVahug%3D%3D
    • Glover PM, Cavin I, Qian W, Bowtell R, Gowland PA. Magnetic-field-induced vertigo: a theoretical and experimental investigation. Bioelectromagnetics. 2007;28(5):349-61.
    • (2007) Bioelectromagnetics , vol.28 , Issue.5 , pp. 349-361
    • Glover, P.M.1    Cavin, I.2    Qian, W.3    Bowtell, R.4    Gowland, P.A.5
  • 24
    • 33644839187 scopus 로고    scopus 로고
    • Musculoskeletal imaging at 3T: Current techniques and future applications
    • 16530635 10.1016/j.mric.2005.12.002
    • Mosher TJ. Musculoskeletal imaging at 3T: current techniques and future applications. Magn Reson Imaging Clin N Am. 2006;14(1):63-76.
    • (2006) Magn Reson Imaging Clin N Am , vol.14 , Issue.1 , pp. 63-76
    • Mosher, T.J.1
  • 25
    • 80051587689 scopus 로고    scopus 로고
    • A radiofrequency coil to facilitate B(1)(+) shimming and parallel imaging acceleration in three dimensions at 7 T
    • 21834005 10.1002/nbm.1627
    • Gilbert KM, Curtis AT, Gati JS, Klassen LM, Menon RS. A radiofrequency coil to facilitate B(1)(+) shimming and parallel imaging acceleration in three dimensions at 7 T. NMR Biomed. 2011;24(7):815-23.
    • (2011) NMR Biomed , vol.24 , Issue.7 , pp. 815-823
    • Gilbert, K.M.1    Curtis, A.T.2    Gati, J.S.3    Klassen, L.M.4    Menon, R.S.5
  • 26
    • 41849145236 scopus 로고    scopus 로고
    • Overcoming high-field RF problems with non-magnetic Cartesian feedback transceivers
    • 18026763 10.1007/s10334-007-0089-8 1:STN:280:DC%2BD1c3jtVGitg%3D%3D
    • Hoult DI, Foreman D, Kolansky G, Kripiakevich D. Overcoming high-field RF problems with non-magnetic Cartesian feedback transceivers. Magma. 2008;21(1-2):15-29.
    • (2008) Magma , vol.21 , Issue.1-2 , pp. 15-29
    • Hoult, D.I.1    Foreman, D.2    Kolansky, G.3    Kripiakevich, D.4
  • 27
    • 80052788738 scopus 로고    scopus 로고
    • The role of MR imaging in avascular necrosis of the femoral head
    • 21644201 10.1055/s-0031-1278427
    • Karantanas AH, Drakonaki EE. The role of MR imaging in avascular necrosis of the femoral head. Semin Musculoskelet Radiol. 2011;15(3):281-300.
    • (2011) Semin Musculoskelet Radiol , vol.15 , Issue.3 , pp. 281-300
    • Karantanas, A.H.1    Drakonaki, E.E.2
  • 28
    • 51649086479 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the hip at 3 Tesla: Clinical value in femoroacetabular impingement of the hip and current concepts
    • 18850503 10.1055/s-0028-1083105
    • Mamisch TC, Bittersohl B, Hughes T, Kim YJ, Welsch GH, Dudda M, et al. Magnetic resonance imaging of the hip at 3 Tesla: clinical value in femoroacetabular impingement of the hip and current concepts. Semin Musculoskelet Radiol. 2008;12(3):212-22.
    • (2008) Semin Musculoskelet Radiol , vol.12 , Issue.3 , pp. 212-222
    • Mamisch, T.C.1    Bittersohl, B.2    Hughes, T.3    Kim, Y.J.4    Welsch, G.H.5    Dudda, M.6
  • 29
    • 33644835009 scopus 로고    scopus 로고
    • 3T MR imaging of the musculoskeletal system (Part I): Considerations, coils, and challenges
    • 16530633 10.1016/j.mric.2006.01.001
    • Ramnath RR. 3T MR imaging of the musculoskeletal system (Part I): considerations, coils, and challenges. Magn Reson Imaging Clin N Am. 2006;14(1):27-40.
    • (2006) Magn Reson Imaging Clin N Am , vol.14 , Issue.1 , pp. 27-40
    • Ramnath, R.R.1
  • 30
    • 33644837451 scopus 로고    scopus 로고
    • 3T MR imaging of the musculoskeletal system (Part II): Clinical applications
    • 16530634 10.1016/j.mric.2006.01.003
    • Ramnath RR. 3T MR imaging of the musculoskeletal system (Part II): clinical applications. Magn Reson Imaging Clin N Am. 2006;14(1):41-62.
    • (2006) Magn Reson Imaging Clin N Am , vol.14 , Issue.1 , pp. 41-62
    • Ramnath, R.R.1
  • 31
    • 29844447052 scopus 로고    scopus 로고
    • 3.0 vs 1.5 T MRI in the detection of focal cartilage pathology-ROC analysis in an experimental model
    • 16188466 10.1016/j.joca.2005.08.002 1:STN:280:DC%2BD28%2FhsVWktA%3D%3D
    • Link TM, Sell CA, Masi JN, Phan C, Newitt D, Lu Y, et al. 3.0 vs 1.5 T MRI in the detection of focal cartilage pathology-ROC analysis in an experimental model. Osteoarthritis Cartilage. 2006;14(1):63-70.
    • (2006) Osteoarthritis Cartilage , vol.14 , Issue.1 , pp. 63-70
    • Link, T.M.1    Sell, C.A.2    Masi, J.N.3    Phan, C.4    Newitt, D.5    Lu, Y.6
  • 32
    • 82555172132 scopus 로고    scopus 로고
    • Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk
    • 22129641 10.1097/RMR.0b013e31823ccebc
    • Bae WC, Du J, Bydder GM, Chung CB. Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk. Topics in magnetic resonance imaging: TMRI. 2010;21(5):275-89.
    • (2010) Topics in Magnetic Resonance Imaging: TMRI , vol.21 , Issue.5 , pp. 275-289
    • Bae, W.C.1    Du, J.2    Bydder, G.M.3    Chung, C.B.4
  • 33
    • 77950263339 scopus 로고    scopus 로고
    • Ultrashort echo time MR imaging of osteochondral junction of the knee at 3 T: Identification of anatomic structures contributing to signal intensity
    • 20177096 10.1148/radiol.09081743
    • Bae WC, Dwek JR, Znamirowski R, Statum SM, Hermida JC, D'Lima DD, et al. Ultrashort echo time MR imaging of osteochondral junction of the knee at 3 T: identification of anatomic structures contributing to signal intensity. Radiology. 2010;254(3):837-45.
    • (2010) Radiology , vol.254 , Issue.3 , pp. 837-845
    • Bae, W.C.1    Dwek, J.R.2    Znamirowski, R.3    Statum, S.M.4    Hermida, J.C.5    D'Lima, D.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.