Volumn 105, Issue 10, 2013, Pages 69-70

Effect of connection type on galvanic corrosion between lead and copper pipes

Author keywords

[No Author keywords available]

Indexed keywords

BENCH-SCALE TEST; COMPARISON TESTING; GALVANIC CORROSION; GALVANIC CURRENT; LEAD RELEASE; PIPE CONNECTOR; TAP WATER; ZINC CONTENT;

EID: 84885415539     PISSN: 0003150X     EISSN: 15518833     Source Type: Journal    
DOI: 10.5942/jawwa.2013.105.0113     Document Type: Article
Times cited : (16)

References (7)
  • 2
    • 78751591480 scopus 로고    scopus 로고
    • Association between children's blood lead levels, lead service lines, and water disinfection, washington, D.C., 1998-2006
    • Brown, M.J.; Raymond, J.; Homa, D.; Kennedy, C; & Sinks, I,2011. Association Between Children's Blood Lead Levels, Lead Service Lines, and Water Disinfection, Washington, D.C., 1998-2006. Environmental Research, 111:1:67. http://dx.doi.org/10.1016/ j.envres.2010.10.003.
    • (2011) Environmental Research , vol.111 , Issue.1 , pp. 67
    • Brown, M.J.1    Raymond, J.2    Homa, D.3    Kennedy, C.4    Sinks, I.5
  • 3
    • 84862765970 scopus 로고    scopus 로고
    • Effect of flow rate and lead/copper pipe sequence on lead release from service lines
    • Cartier, C; Arnold, R.B. Jr.; Triantafyllidou, S.; Prevost, M.; & Edwards, M., 2012. Effect of Flow Rate and Lead/Copper Pipe Sequence on Lead Release from Service Lines. Water Research, 46:13:4142. http://dx.doi.Org/10. 1016/j.watres.2012.05.010.
    • (2012) Water Research , vol.46 , Issue.13 , pp. 4142
    • Cartier, C.1    Arnold Jr., R.B.2    Triantafyllidou, S.3    Prevost, M.4    Edwards, M.5
  • 5
    • 84865744327 scopus 로고    scopus 로고
    • Copper-induced metal release from lead pipe into drinking water
    • Hu, J.; Gan, F.; Triantafyllidou, S.; Nguyen, C.K.; & Edwards, M., 2012. Copper-induced Metal Release From Lead Pipe Into Drinking Water. Corrosion, 68:11:1037. http://dx.doi.org/10.5006/0616.
    • (2012) Corrosion , vol.68 , Issue.11 , pp. 1037
    • Hu, J.1    Gan, F.2    Triantafyllidou, S.3    Nguyen, C.K.4    Edwards, M.5
  • 6
    • 84865991465 scopus 로고    scopus 로고
    • Impact of galvanic corrosion on lead release from aged lead service lines
    • Wang, Y.; Jing, H.; Mehta, V.; Welter, G.J.; & Giammar, D.E., 2012. Impact of Galvanic Corrosion on Lead Release From Aged Lead Service Lines. Water Research, 46:5049. http://dx.doi.org/10.1016/ j.watres.2012.06.046.
    • (2012) Water Research , vol.46 , pp. 5049
    • Wang, Y.1    Jing, H.2    Mehta, V.3    Welter, G.J.4    Giammar, D.E.5
  • 7
    • 84862766457 scopus 로고    scopus 로고
    • Galvanic corrosion after simulated small-scale partial lead service line replacements
    • Triantafyllidou, S. & Edwards, M" 2011. Galvanic Corrosion After Simulated Small-scale Partial Lead Service Line Replacements. Journal AWWA, 103:9:85.
    • (2011) Journal AWWA , vol.103 , Issue.9 , pp. 85
    • Triantafyllidou, S.1    Edwards, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.