메뉴 건너뛰기




Volumn 70, Issue 4, 2013, Pages 962-971

Generalized inverse imaging (GIN): Ultrafast fMRI with physiological noise correction

Author keywords

3 Tesla; BOLD; brain; GIN; neuroimaging; regression; ultrafast fMRI

Indexed keywords

BRAIN; CHEMICAL ACTIVATION; INVERSE PROBLEMS; MAGNETIC RESONANCE IMAGING; NEUROIMAGING; PHYSIOLOGICAL MODELS; PHYSIOLOGY;

EID: 84885324226     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24528     Document Type: Article
Times cited : (26)

References (41)
  • 1
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S, Lee TM, Kay A, Tank D,. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci U S A 1990; 87: 9868-9872.
    • (1990) Proc Natl Acad Sci U S A , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.3    Tank, D.4
  • 2
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 5
    • 79551590695 scopus 로고    scopus 로고
    • Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils
    • Triantafyllou C, Polimeni JR, Wald LL,. Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils. Neuroimage 2011; 55: 597-606.
    • (2011) Neuroimage , vol.55 , pp. 597-606
    • Triantafyllou, C.1    Polimeni, J.R.2    Wald, L.L.3
  • 7
    • 77955292827 scopus 로고    scopus 로고
    • Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI
    • Moeller S, Yacoub E, Olman CA, Auerbach E, Strupp J, Harel N, Uǧurbil K,. Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI. Magn Reson Med 2009; 63: 1144-1153.
    • (2009) Magn Reson Med , vol.63 , pp. 1144-1153
    • Moeller, S.1    Yacoub, E.2    Olman, C.A.3    Auerbach, E.4    Strupp, J.5    Harel, N.6    Uǧurbil, K.7
  • 9
    • 84863655248 scopus 로고    scopus 로고
    • Whole brain, high resolution spin-echo resting state fMRI using PINS multiplexing at 7 Tesla
    • Koopmans PJ, Boyacioǧlu R, Barth M, Norris DG,. Whole brain, high resolution spin-echo resting state fMRI using PINS multiplexing at 7 Tesla. Neuroimage 2012; 62: 1939-1946.
    • (2012) Neuroimage , vol.62 , pp. 1939-1946
    • Koopmans, P.J.1    Boyacioǧlu, R.2    Barth, M.3    Norris, D.G.4
  • 10
    • 14744304684 scopus 로고    scopus 로고
    • Controlled Aliasing in Parallel Imaging Results in Higher Acceleration (CAIPIRINHA) for Multi-Slice Imaging
    • Breuer FA, Blaimer M, Heidemann RM, Mueller MF, Griswold MA, Jakob PM,. Controlled Aliasing in Parallel Imaging Results in Higher Acceleration (CAIPIRINHA) for Multi-Slice Imaging. Magn Reson Med 2005; 53: 684-691.
    • (2005) Magn Reson Med , vol.53 , pp. 684-691
    • Breuer, F.A.1    Blaimer, M.2    Heidemann, R.M.3    Mueller, M.F.4    Griswold, M.A.5    Jakob, P.M.6
  • 11
    • 84859705233 scopus 로고    scopus 로고
    • Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planer imaging with reduced g-factor penalty
    • Setsompop K, Gagoski BA, Polimeni JR, Witzel T, Wedeen VJ, Wald LL,. Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planer imaging with reduced g-factor penalty. Magn Reson Med 2012; 67: 1210-1224.
    • (2012) Magn Reson Med , vol.67 , pp. 1210-1224
    • Setsompop, K.1    Gagoski, B.A.2    Polimeni, J.R.3    Witzel, T.4    Wedeen, V.J.5    Wald, L.L.6
  • 16
    • 33751084621 scopus 로고    scopus 로고
    • MR-encephalography: Fast multi-channel monitoring of brain physiology with magnetic resonance
    • Hennig J, Zhong K, Speck O,. MR-encephalography: fast multi-channel monitoring of brain physiology with magnetic resonance. Neuroimage 2007; 34: 212-219.
    • (2007) Neuroimage , vol.34 , pp. 212-219
    • Hennig, J.1    Zhong, K.2    Speck, O.3
  • 20
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Börnert P, Boesiger P,. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001; 46: 638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Börnert, P.3    Boesiger, P.4
  • 21
    • 0001632418 scopus 로고
    • The use of the L-curve in the regularization of discrete ill-posed problems
    • Hansen PC, O'Leary DP,. The use of the L-curve in the regularization of discrete ill-posed problems. SIAM J Sci Comput 1993; 14: 1487-1503.
    • (1993) SIAM J Sci Comput , vol.14 , pp. 1487-1503
    • Hansen, P.C.1    O'Leary, D.P.2
  • 23
    • 0036828879 scopus 로고    scopus 로고
    • Fast robust automated brain extraction
    • Smith SM,. Fast robust automated brain extraction. Hum Brain Mapp 2002; 17: 143-155.
    • (2002) Hum Brain Mapp , vol.17 , pp. 143-155
    • Smith, S.M.1
  • 24
    • 85006186246 scopus 로고    scopus 로고
    • Two-axis acceleration of functional connectivity magnetic resonance imaging by parallel excitation of phase-tagged slices and half k-space acceleration
    • Jesmanowicz A, Nencka AS, Li SJ, Hyde JS,. Two-axis acceleration of functional connectivity magnetic resonance imaging by parallel excitation of phase-tagged slices and half k-space acceleration. Brain Connect 2011; 1: 81-90.
    • (2011) Brain Connect , vol.1 , pp. 81-90
    • Jesmanowicz, A.1    Nencka, A.S.2    Li, S.J.3    Hyde, J.S.4
  • 27
    • 0033856106 scopus 로고    scopus 로고
    • Tailored SMASH image reconstructions for robust in vivo parallel MR imaging
    • Sodickson DK,. Tailored SMASH image reconstructions for robust in vivo parallel MR imaging. Magn Reson Med 2000; 44: 243-251.
    • (2000) Magn Reson Med , vol.44 , pp. 243-251
    • Sodickson, D.K.1
  • 28
    • 84857210267 scopus 로고    scopus 로고
    • Assessment of physiological noise modelling methods for functional imaging of the spinal cord
    • Kong Y, Jenkinson M, Andersson J, Tracey I, Brooks JCW,. Assessment of physiological noise modelling methods for functional imaging of the spinal cord. Neuroimage 2011; 60: 1538-1549.
    • (2011) Neuroimage , vol.60 , pp. 1538-1549
    • Kong, Y.1    Jenkinson, M.2    Andersson, J.3    Tracey, I.4    Brooks, J.C.W.5
  • 29
    • 84859038449 scopus 로고    scopus 로고
    • Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging
    • Posse S, Ackley E, Mutihac R, Rick J, Shane M, Murray-Krezan C, Zaitsev M, Speck O,. Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging. Neuroimage 2012; 61: 115-130.
    • (2012) Neuroimage , vol.61 , pp. 115-130
    • Posse, S.1    Ackley, E.2    Mutihac, R.3    Rick, J.4    Shane, M.5    Murray-Krezan, C.6    Zaitsev, M.7    Speck, O.8
  • 31
    • 0033934775 scopus 로고    scopus 로고
    • Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR
    • Glover GH, Li TQ, Ress D,. Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR. Magn Reson Med 2000; 44: 162-167.
    • (2000) Magn Reson Med , vol.44 , pp. 162-167
    • Glover, G.H.1    Li, T.Q.2    Ress, D.3
  • 32
    • 79952740130 scopus 로고    scopus 로고
    • Using pulse oximetry to account for high and low frequency physiological artifacts in the BOLD signal
    • Verstynen TD, Deshpande V,. Using pulse oximetry to account for high and low frequency physiological artifacts in the BOLD signal. Neuroimage 2011; 55: 1633-1644.
    • (2011) Neuroimage , vol.55 , pp. 1633-1644
    • Verstynen, T.D.1    Deshpande, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.