Volumn 9, Issue 5, 2008, Pages 450-453

Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion: Clinical article

Author keywords

IsoC 3D; Neuronavigation; Pedicle screw; Three dimensional fluoroscopy

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CERVICAL SPINE; CLINICAL ARTICLE; CLINICAL ASSESSMENT; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; FLUOROSCOPY; HUMAN; INTRAOPERATIVE PERIOD; MALE; NEURONAVIGATION; ORTHOPEDIC EQUIPMENT; PEDICLE SCREW; POSTOPERATIVE PERIOD; SPINE SURGERY; SURGICAL APPROACH; SURGICAL TECHNIQUE; THREE DIMENSIONAL IMAGING; BONE SCREW; METHODOLOGY; MIDDLE AGED; PROSPECTIVE STUDY; RADIOGRAPHY; REPRODUCIBILITY; SPINE DISEASE; SPINE FUSION;

EID: 58149168458     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/SPI.2008.9.11.450     Document Type: Article
Times cited : (114)

References (18)
  • 1
    • 0028012268 scopus 로고
    • Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: Description of the techniques and preliminary report
    • Abumi K, Itoh H, Taneichi H, Kaneda K: Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7:19-28, 1994 (Pubitemid 24064744)
    • (1994) Journal of Spinal Disorders , vol.7 , Issue.1 , pp. 19-28
    • Abumi, K.1    Itoh, H.2    Taneichi, H.3    Kaneda, K.4
  • 2
    • 1242331911 scopus 로고    scopus 로고
    • C-arm-based three-dimensional navigation: A preliminary feasibility study
    • Euler E, Heining S, Riquarts C, Mutschler W: C-arm-based three-dimensional navigation: a preliminary feasibility study. Comput Aided Surg 8:35-41, 2003
    • (2003) Comput Aided Surg , vol.8 , pp. 35-41
    • Euler, E.1    Heining, S.2    Riquarts, C.3    Mutschler, W.4
  • 3
    • 33645499877 scopus 로고    scopus 로고
    • Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy
    • Holly LT, Foley KT: Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine 31:536-541, 2006
    • (2006) Spine , vol.31 , pp. 536-541
    • Holly, L.T.1    Foley, K.T.2
  • 5
    • 21244433504 scopus 로고    scopus 로고
    • Intraoperative Iso-C C-arm navigation in cervical spinal surgery: Review of the first 52 cases
    • Hott JS, Papadopoulos SM, Theodore N, Dickman CA, Sonntag VK: Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine 29:2856-2860, 2004
    • (2004) Spine , vol.29 , pp. 2856-2860
    • Hott, J.S.1    Papadopoulos, S.M.2    Theodore, N.3    Dickman, C.A.4    Sonntag, V.K.5
  • 6
    • 66049146833 scopus 로고    scopus 로고
    • Intraoperative Iso-C C-arm navigation in cervical spinal surgery
    • Jpn
    • Ito Y, Hashimoto T: [Intraoperative Iso-C C-arm navigation in cervical spinal surgery.] J Western Japanese Res Soc Spine 33:71-75, 2007 (Jpn)
    • (2007) J Western Japanese Res Soc Spine , vol.33 , pp. 71-75
    • Ito, Y.1    Hashimoto, T.2
  • 8
    • 0028336015 scopus 로고
    • Transpedicular screw fixation of articular mass fracture-separation: Results of an anatomical study and operative technique
    • Jeanneret B, Gebhard JS, Magerl F: Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7:222-229, 1994 (Pubitemid 24164827)
    • (1994) Journal of Spinal Disorders , vol.7 , Issue.3 , pp. 222-229
    • Jeanneret, B.1    Gebhard, J.S.2    Magerl, F.3    Ducker, T.B.4
  • 9
    • 0031010622 scopus 로고    scopus 로고
    • Cervical pedicle screws versus lateral mass screws: Anatomic feasibility and biomechanical comparison
    • Jones EL, Heller JG, Silcox DH, Hutton WC: Cervical pedicle screws versus lateral mass screws: anatomic feasibility and biomechanical comparison. Spine 22:977-982, 1997
    • (1997) Spine , vol.22 , pp. 977-982
    • Jones, E.L.1    Heller, J.G.2    Silcox, D.H.3    Hutton, W.C.4
  • 11
    • 0142120120 scopus 로고    scopus 로고
    • Improved accuracy of computer-assisted cervical pedicle screw insertion
    • Kotani Y, Abumi K, Ito M, Minami A: Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257-263, 2003
    • (2003) J Neurosurg , vol.99 , pp. 257-263
    • Kotani, Y.1    Abumi, K.2    Ito, M.3    Minami, A.4
  • 12
    • 34250782220 scopus 로고    scopus 로고
    • Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: Comparison between conventional fluoroscopic and computer-assisted technique
    • DOI 10.1097/BRS.0b013e318068661e, PII 0000763220070615000014
    • Kotani Y, Abumi K, Ito M, Takahata M, Sudo H, Ohshima S, et al: Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine 32:1543-1550, 2007 (Pubitemid 46956151)
    • (2007) Spine , vol.32 , Issue.14 , pp. 1543-1550
    • Kotani, Y.1    Abumi, K.2    Ito, M.3    Takahata, M.4    Sudo, H.5    Ohshima, S.6    Minami, A.7
  • 13
    • 0027999435 scopus 로고
    • Biomechanical analysis of cervical stabilization systems: An assessment of transpedicular screw fixation in the cervical spine
    • Kotani Y, Cunningham BW, Abumi K, McAfee PC: Biomechanical analysis of cervical stabilization systems: an assessment of transpedicular screw fixation in the cervical spine. Spine 19:2529-2539, 1994 (Pubitemid 24356455)
    • (1994) Spine , vol.19 , Issue.22 , pp. 2529-2539
    • Kotani, Y.1    Cunningham, B.W.2    Abumi, K.3    McAfee, P.C.4
  • 14
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D: Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235-240, 2000
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3    Lohikoski, J.4    Schlenzka, D.5
  • 15
    • 29444456659 scopus 로고    scopus 로고
    • The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae
    • DOI 10.1097/01.brs.0000192297.07709.5d
    • Neo M, Sakamoto T, Fujibayashi S, Nakamura T: The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine 30:2800-2805, 2005 (Pubitemid 43011045)
    • (2005) Spine , vol.30 , Issue.24 , pp. 2800-2805
    • Neo, M.1    Sakamoto, T.2    Fujibayashi, S.3    Nakamura, T.4
  • 16
    • 33846239956 scopus 로고    scopus 로고
    • Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
    • DOI 10.1097/01.brs.0000252094.64857.ab, PII 0000763220070115000030
    • Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP: Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine 32:E56-E64, 2007 (Pubitemid 46105794)
    • (2007) Spine , vol.32 , Issue.2
    • Rajasekaran, S.1    Vidyadhara, S.2    Ramesh, P.3    Shetty, A.P.4
  • 17
    • 27144527301 scopus 로고    scopus 로고
    • Cervical pedicle screws: Conventional versus computer-assisted placement of cannulated screws
    • DOI 10.1097/01.brs.0000182275.31425.cd
    • Richter M, Cakir B, Schmidt R: Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine 30:2280-2287, 2005 (Pubitemid 41504897)
    • (2005) Spine , vol.30 , Issue.20 , pp. 2280-2287
    • Richter, M.1    Cakir, B.2    Schmidt, R.3
  • 18
    • 33646456917 scopus 로고    scopus 로고
    • Computerized tomographic measurement of the cervical pedicles diameter in a Malaysian population and the feasibility for transpedicular fixation
    • Yusof MI, Ming LK, Abdullah MS, Yusof AH: Computerized tomographic measurement of the cervical pedicles diameter in a Malaysian population and the feasibility for transpedicular fixation. Spine 31:E221-E224, 2006
    • (2006) Spine , vol.31
    • Yusof, M.I.1    Ming, L.K.2    Abdullah, M.S.3    Yusof, A.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.