메뉴 건너뛰기




Volumn 168, Issue 2, 2013, Pages 1269-1273

Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding medtronic core valve system

Author keywords

Dependency; Follow up; Permanent pacemaker implantation; Transcatheter aortic valve implantation

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; ATRIOVENTRICULAR CONDUCTION; BRADYCARDIA; COHORT ANALYSIS; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEART LEFT BUNDLE BRANCH BLOCK; HEART VENTRICLE TACHYCARDIA; HUMAN; MAJOR CLINICAL STUDY; MALE; OBSERVATIONAL STUDY; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; SECOND DEGREE ATRIOVENTRICULAR BLOCK; TACHYCARDIA; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT INDICATION; TREATMENT OUTCOME; TREATMENT RESPONSE;

EID: 84885306863     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2012.11.115     Document Type: Article
Times cited : (99)

References (31)
  • 1
    • 44949107279 scopus 로고    scopus 로고
    • Transcatheter valve Implantation for patients with aortic stenosis: A position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCi)
    • Vahanian A, Alfieri O, Al-Attar N, et al. Transcatheter valve Implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), In collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCi). Eur Heart J 2008;29:1463-70.
    • (2008) Eur Heart J , vol.29 , pp. 1463-1470
    • Vahanian, A.1    Alfieri, O.2    Al-Attar, N.3
  • 2
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve Implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, MackM, et al. Transcatheter aortic-valve Implantation for aortic stenosis In patients who cannot undergo surgery. N Engl J Med 2010;363:1597-607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 3
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement In high-risk patients. N Engl J Med 2011;364:2187-98.
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 4
    • 84864285945 scopus 로고    scopus 로고
    • New conduction abnormalities after TAVi-frequency and causes
    • van der Boon RM, Nuis R-J, Van Mieghem NM, et al. New conduction abnormalities after TAVi-frequency and causes. Nat Rev Cardiol 2012;9:454-63.
    • (2012) Nat Rev Cardiol , vol.9 , pp. 454-463
    • Van Der Boon, R.M.1    Nuis, R.-J.2    Van Mieghem, N.M.3
  • 5
    • 33750336350 scopus 로고    scopus 로고
    • Left ventricular lead electrical delay predicts response to cardiac resynchronization therapy
    • Singh JP, Fan D, Heist EK, et al. Left ventricular lead electrical delay predicts response to cardiac resynchronization therapy. Heart Rhythm 2006;3:1285-92.
    • (2006) Heart Rhythm , vol.3 , pp. 1285-1292
    • Singh, J.P.1    Fan, D.2    Heist, E.K.3
  • 6
    • 76649117775 scopus 로고    scopus 로고
    • Analysis of ventricular activation using surface electrocardiography to predict left ventricular reverse volumetric remodeling during cardiac resynchronization therapy
    • SweeneyMO, van Bommel RJ, SchalijMJ, Borleffs CJW,Hellkamp AS, Bax JJ. analysis of ventricular activation using surface electrocardiography to predict left ventricular reverse volumetric remodeling during cardiac resynchronization therapy. Circulation 2010;121:626-34.
    • (2010) Circulation , vol.121 , pp. 626-634
    • Sweeney, M.O.1    Van Bommel, R.J.2    Schalij, M.J.3    Borleffs, C.J.W.4    Hellkamp, A.S.5    Bax, J.J.6
  • 7
    • 78650904577 scopus 로고    scopus 로고
    • Frequency of conduction abnormalities after transcatheter aortic valve Implantation with the Medtronic-CoreValve and the effect on left ventricular ejection fraction
    • Tzikas A, van Dalen BM, VanMieghemNM, et al. Frequency of conduction abnormalities after transcatheter aortic valve Implantation with the Medtronic-CoreValve and the effect on left ventricular ejection fraction. Am J Cardiol 2011;107:285-9.
    • (2011) Am J Cardiol , vol.107 , pp. 285-289
    • Tzikas, A.1    Van Dalen, B.M.2    Van Mieghem, N.M.3
  • 8
    • 0024517171 scopus 로고
    • Functional abnormalities in Isolated left bundle branch block. The effect of Interventricular asynchrony
    • Grines CL, Bashore TM, Boudoulas H, Olson S, Shafer P,Wooley CF. Functional abnormalities In Isolated left bundle branch block. The effect of Interventricular asynchrony. Circulation 1989;79:845-53.
    • (1989) Circulation , vol.79 , pp. 845-853
    • Grines, C.L.1    Bashore, T.M.2    Boudoulas, H.3    Olson, S.4    Shafer, P.5    Wooley, C.F.6
  • 10
    • 13544260792 scopus 로고    scopus 로고
    • Left bundle branch block Induces ventricular remodelling and functional septal hypoperfusion
    • Vernooy K, Verbeek XAAM, Peschar M, et al. Left bundle branch block Induces ventricular remodelling and functional septal hypoperfusion. Eur Heart J 2005;26:91-8.
    • (2005) Eur Heart J , vol.26 , pp. 91-98
    • Vernooy, K.1    Verbeek, X.A.A.M.2    Peschar, M.3
  • 11
    • 33846055922 scopus 로고    scopus 로고
    • Left bundle branch block as a risk factor for progression to heart failure
    • Zannad F, Huvelle E, Dickstein K, et al. Left bundle branch block as a risk factor for progression to heart failure. Eur J Heart Fail 2007;9:7-14.
    • (2007) Eur J Heart Fail , vol.9 , pp. 7-14
    • Zannad, F.1    Huvelle, E.2    Dickstein, K.3
  • 12
    • 2442479695 scopus 로고    scopus 로고
    • Cardiac-resynchronization therapy with or without an Implantable defibrillator in advanced chronic heart failure
    • Bristow MR, Saxon LA, Boehmer J, et al. Cardiac-resynchronization therapy with or without an Implantable defibrillator In advanced chronic heart failure. N Engl J Med 2004;350:2140-50.
    • (2004) N Engl J Med , vol.350 , pp. 2140-2150
    • Bristow, M.R.1    Saxon, L.A.2    Boehmer, J.3
  • 13
    • 16844364826 scopus 로고    scopus 로고
    • The effect of cardiac resynchronization on morbidity and mortality in heart failure
    • Cleland JGF, Daubert J-C, Erdmann E, et al. The effect of cardiac resynchronization on morbidity and mortality In heart failure. N Engl J Med 2005;352:1539-49.
    • (2005) N Engl J Med , vol.352 , pp. 1539-1549
    • Cleland, J.G.F.1    Daubert, J.-C.2    Erdmann, E.3
  • 14
    • 78650215892 scopus 로고    scopus 로고
    • Cardiac-resynchronization therapy for mild-tomoderate heart failure
    • Tang ASL,Wells GA, Talajic M, et al. Cardiac-resynchronization therapy for mild-tomoderate heart failure. N Engl J Med 2010;363:2385-95.
    • (2010) N Engl J Med , vol.363 , pp. 2385-2395
    • Tang, A.S.L.1    Wells, G.A.2    Talajic, M.3
  • 15
    • 80054729062 scopus 로고    scopus 로고
    • The relationship between ventricular electrical delay and left ventricular remodellingwith cardiac resynchronization therapy
    • Gold MR, Birgersdotter-Green U, Singh JP, et al. The relationship between ventricular electrical delay and left ventricular remodellingwith cardiac resynchronization therapy. Eur Heart J 2011;32:2516-24.
    • (2011) Eur Heart J , vol.32 , pp. 2516-2524
    • Gold, M.R.1    Birgersdotter-Green, U.2    Singh, J.P.3
  • 16
    • 44949088496 scopus 로고    scopus 로고
    • Early and persistent Intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve
    • Piazza N, Onuma Y, Jesserun E, et al. Early and persistent Intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve. JACC Cardiovasc Interv 2008;1:310-6.
    • (2008) JACC Cardiovasc Interv , vol.1 , pp. 310-316
    • Piazza, N.1    Onuma, Y.2    Jesserun, E.3
  • 17
    • 79952198456 scopus 로고    scopus 로고
    • Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve Implantation
    • Piazza N, Nuis R-J, Tzikas A, et al. Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve Implantation. EuroIntervention 2010;6:475-84.
    • (2010) EuroIntervention , vol.6 , pp. 475-484
    • Piazza, N.1    Nuis, R.-J.2    Tzikas, A.3
  • 18
    • 67650514071 scopus 로고    scopus 로고
    • Electrocardiographic changes and clinical outcomes after transapical aortic valve Implantation
    • GutiérrezM, Rodés-Cabau J, Bagur R, et al. Electrocardiographic changes and clinical outcomes after transapical aortic valve Implantation. Am Heart J 2009;158:302-8.
    • (2009) Am Heart J , vol.158 , pp. 302-308
    • Gutiérrez, M.1    Rodés-Cabau, J.2    Bagur, R.3
  • 19
    • 79951581461 scopus 로고    scopus 로고
    • Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve Implantation
    • Fraccaro C, Buja G, Tarantini G, et al. Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve Implantation. Am J Cardiol 2011;107:747-54.
    • (2011) Am J Cardiol , vol.107 , pp. 747-754
    • Fraccaro, C.1    Buja, G.2    Tarantini, G.3
  • 20
    • 80955163682 scopus 로고    scopus 로고
    • Predictors and course of high-degree atrioventricular block after transcatheter aortic valve Implantation using the CoreValve Revalving system
    • Guetta V, Goldenberg G, Segev A, et al. Predictors and course of high-degree atrioventricular block after transcatheter aortic valve Implantation using the CoreValve Revalving system. Am J Cardiol 2011;108:1600-5.
    • (2011) Am J Cardiol , vol.108 , pp. 1600-1605
    • Guetta, V.1    Goldenberg, G.2    Segev, A.3
  • 21
    • 79957940876 scopus 로고    scopus 로고
    • Effect of experience on results of transcatheter aortic valve Implantation using a Medtronic CoreValve System
    • Nuis R-J, van Mieghem NM, van der Boon RM, et al. Effect of experience on results of transcatheter aortic valve Implantation using a Medtronic CoreValve System. Am J Cardiol 2011;107:1824-9.
    • (2011) Am J Cardiol , vol.107 , pp. 1824-1829
    • Nuis, R.-J.1    Van Mieghem, N.M.2    Van Der Boon, R.M.3
  • 22
    • 55049111038 scopus 로고    scopus 로고
    • Population characteristics, treatment assignment and survival of patients with aortic stenosis referred for percutaneous valve replacement
    • Otten AM, van Domburg RT, van Gameren M, et al. Population characteristics, treatment assignment and survival of patients with aortic stenosis referred for percutaneous valve replacement. EuroIntervention 2008;4:250-5.
    • (2008) EuroIntervention , vol.4 , pp. 250-255
    • Otten, A.M.1    Van Domburg, R.T.2    Van Gameren, M.3
  • 23
    • 80052018699 scopus 로고    scopus 로고
    • Timing and potential mechanisms of new conduction abnormalities during the Implantation of the Medtronic CoreValve System in patients with aortic stenosis
    • Nuis R-J, Van Mieghem NM, Schultz CJ, et al. Timing and potential mechanisms of new conduction abnormalities during the Implantation of the Medtronic CoreValve System In patients with aortic stenosis. Eur Heart J 2011;32:2067-74.
    • (2011) Eur Heart J , vol.32 , pp. 2067-2074
    • Nuis, R.-J.1    Van Mieghem, N.M.2    Schultz, C.J.3
  • 24
    • 0021877091 scopus 로고
    • Criteria for Intraventricular conduction disturbances and pre-excitation. World Health Organizational/International Society and Federation for Cardiology Task Force Ad Hoc
    • Willems JL, de Medina EO Robles, Bernard R, et al. Criteria for Intraventricular conduction disturbances and pre-excitation.World Health Organizational/International Society and Federation for Cardiology Task Force Ad Hoc. J Am Coll Cardiol 1985;5: 1261-75.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 1261-1275
    • Willems, J.L.1    Robles. Eo D.Medina2    Bernard, R.3
  • 25
    • 78149452061 scopus 로고    scopus 로고
    • Incidence and predictors of atrioventricular conduction Impairment after transcatheter aortic valve Implantation
    • Roten L,Wenaweser P, Delacrétaz E, et al. Incidence and predictors of atrioventricular conduction Impairment after transcatheter aortic valve Implantation. Am J Cardiol 2010;106:1473-80.
    • (2010) Am J Cardiol , vol.106 , pp. 1473-1480
    • Roten, L.1    Wenaweser, P.2    Delacrétaz, E.3
  • 26
    • 84860395530 scopus 로고    scopus 로고
    • Atrioventricular conduction disturbance characterization in transcatheter aortic valve Implantation with the CoreValve prosthesis
    • Rubín JM, Avanzas P, del Valle R, et al. Atrioventricular conduction disturbance characterization In transcatheter aortic valve Implantation with the CoreValve prosthesis. Circ Cardiovasc Interv 2011;4:280-6.
    • (2011) Circ Cardiovasc Interv , vol.4 , pp. 280-286
    • Rubín, J.M.1    Avanzas, P.2    Del Valle, R.3
  • 27
    • 58149204438 scopus 로고    scopus 로고
    • Permanent pacemaker Implantation following cardiac surgery: Indications and long-term follow-up
    • Merin O, IlanM, Oren A, et al. Permanent pacemaker Implantation following cardiac surgery: Indications and long-term follow-up. Pacing Clin ElectroPhysiol 2009;32: 7-12.
    • (2009) Pacing Clin ElectroPhysiol , vol.32 , pp. 7-12
    • Merin, O.1    Ilan, M.2    Oren, A.3
  • 28
    • 68249132551 scopus 로고    scopus 로고
    • Cause of complete atrioventricular block after percutaneous aortic valve Implantation: Insights from a necropsy study
    • Moreno R, Dobarro D, López de Sá E, et al. Cause of complete atrioventricular block after percutaneous aortic valve Implantation: Insights from a necropsy study. Circulation 2009;120:e29-30.
    • (2009) Circulation , vol.120
    • Moreno, R.1    Dobarro, D.2    López De Sá, E.3
  • 29
    • 79955804163 scopus 로고    scopus 로고
    • Incidence, predictive factors, and prognostic value ofmyocardial Injury following uncomplicated transcatheter aortic valve Implantation
    • Rodés-Cabau J, GutiérrezM, Bagur R, et al. Incidence, predictive factors, and prognostic value ofmyocardial Injury following uncomplicated transcatheter aortic valve Implantation. J Am Coll Cardiol 2011;57:1988-99.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1988-1999
    • Rodés-Cabau, J.1    Gutiérrezm2    Bagur, R.3
  • 30
    • 0037176263 scopus 로고    scopus 로고
    • Dual-chamber pacing or ventricular backup pacing in patients with an Implantable defibrillator: The Dual Chamber and VVi Implantable Defibrillator (DAViD) Trial
    • Wilkoff BL, Cook JR, Epstein AE, et al. Dual-chamber pacing or ventricular backup pacing In patients with an Implantable defibrillator: the Dual Chamber and VVi Implantable Defibrillator (DAViD) Trial. JAMA 2002;288:3115-23.
    • (2002) JAMA , vol.288 , pp. 3115-3123
    • Wilkoff, B.L.1    Cook, J.R.2    Epstein, A.E.3
  • 31
    • 84864724536 scopus 로고    scopus 로고
    • Left bundle-branch block Induced by transcatheter aortic valve Implantation Increases risk of death
    • Houthuizen P, Van Garsse LAFM, Poels TT, et al. Left bundle-branch block Induced by transcatheter aortic valve Implantation Increases risk of death. Circulation 2012;126:720-8.
    • (2012) Circulation , vol.126 , pp. 720-728
    • Houthuizen, P.1    Van Garsse, L.A.F.M.2    Poels, T.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.