메뉴 건너뛰기




Volumn , Issue , 2013, Pages 397-403

State of the art and perspectives on the fabrication of functional contact lenses

Author keywords

Drug delivery systems; Impedance sensors; Micro fabrication; PDMS; Polymer; Smart contact lenses

Indexed keywords

DELIVERY SYSTEMS; DIAGNOSE DISEASE; DRUG DELIVERY SYSTEM; FLEXIBLE POLYMERS; IMPEDANCE SENSORS; PDMS; SALINE SOLUTIONS; STATE OF THE ART;

EID: 84885201387     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1145/2494091.2495971     Document Type: Conference Paper
Times cited : (5)

References (18)
  • 1
    • 84885200358 scopus 로고    scopus 로고
    • The future is now: Unveiling smart lenses
    • May
    • Legerton J. The future is now: unveiling smart lenses. Rev Cornea Contact Lens. 2011 May;147(4):17-.
    • (2011) Rev Cornea Contact Lens , vol.147 , Issue.4 , pp. 17
    • Legerton, J.1
  • 2
    • 84860306461 scopus 로고    scopus 로고
    • Design and wrinkling behavior of a contact lens with an integrated liquid crystal light modulator
    • J De Smet, A Avci, R Beernaert, D Cuypers and H De Smet. Design and wrinkling behavior of a contact lens with an integrated liquid crystal light modulator. Journal of Display Technology. Vol. 8. 2012. 299-305.
    • (2012) Journal of Display Technology , vol.8 , pp. 299-305
    • Smet, J.D.1    Avci, A.2    Beernaert, R.3    Cuypers, D.4    Smet, H.D.5
  • 3
    • 84886601029 scopus 로고    scopus 로고
    • http://www.innovega-inc.com/.
  • 4
    • 84886582766 scopus 로고    scopus 로고
    • www.contactlenses.orgContactlensesmanufacturersassociationnotes.
  • 6
    • 84885209482 scopus 로고    scopus 로고
    • Contact lenses that measure blood glucose
    • Mar. Available at, (Accessed April 2011)
    • Parkinson J. Contact lenses that measure blood glucose. The Future Well. 2010 Mar. Available at: www.thefuturewell.com/2010/03/20/contact-lens (Accessed April 2011).
    • (2010) The Future Well
    • Parkinson, J.1
  • 17
    • 0032964056 scopus 로고    scopus 로고
    • Non invasive electrical measurements for the hydration state of the skin
    • Clarys P, Barel AO, Gabard B. Non invasive electrical measurements for the hydration state of the skin. Skin Res Technology 1999; 5; 14-20.
    • (1999) Skin Res Technology , vol.5 , pp. 14-20
    • Clarys, P.1    Barel, A.O.2    Gabard, B.3
  • 18
    • 84882049142 scopus 로고    scopus 로고
    • Dispersion and correlation of the parameters for skin impedance
    • Me
    • Yamamoto T, Yamamoto Y Dispersion and correlation of the parameters for skin impedance, Med biology Eng 14, 151-158.
    • D Biology Eng , vol.14 , pp. 151-158
    • Yamamoto, T.1    Yamamoto, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.