메뉴 건너뛰기




Volumn 5, Issue 19, 2013, Pages 2331-2332

Importance of matrix effects in LC-MS/MS bioanalysis

Author keywords

hemolyzed plasma; LC MS MS; matrix effects; phospholipids; stability

Indexed keywords

MORPHINE; ORGANIC SOLVENT; PHENOL DERIVATIVE; PHOSPHOLIPID;

EID: 84885191837     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.13.237     Document Type: Editorial
Times cited : (11)

References (9)
  • 1
    • 0030298387 scopus 로고    scopus 로고
    • Quantification of SR 27417 in human plasma using electrospray liquid chromatography- tandem mass spectrometry: A study of ion suppression
    • Buhrman DL, Price PI, Rudewicz PJ. Quantification of SR 27417 in human plasma using electrospray liquid chromatography- tandem mass spectrometry: a study of ion suppression. J. Am. Soc. Mass. Spectrom. 7, 1099-1105 (1996).
    • (1996) J. Am. Soc. Mass. Spectrom. , vol.7 , pp. 1099-1105
    • Buhrman, D.L.1    Price, P.I.2    Rudewicz, P.J.3
  • 2
    • 12044253267 scopus 로고
    • From ions in solution to ions in the gas phase - The mechanism of electrospray mass spectrometry
    • Kebarle P, Tang L. From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry. Anal. Chem. 65(22), 972A-986A (1993).
    • (1993) Anal. Chem. , vol.65 , Issue.22
    • Kebarle, P.1    Tang, L.2
  • 3
    • 14844313671 scopus 로고    scopus 로고
    • Matrix effects: The Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry
    • Taylor PJ. Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry. Clin. Biochem. 38(4), 328-334 (2005).
    • (2005) Clin. Biochem. , vol.38 , Issue.4 , pp. 328-334
    • Taylor, P.J.1
  • 5
    • 79952020424 scopus 로고    scopus 로고
    • Matrix effect elimination during LC-MS/MS bioanalytical method development: A review
    • Côté C, Bergeron A, Mess J-N, Furtado M, Garofolo F. Matrix effect elimination during LC-MS/MS bioanalytical method development: a review. Bioanalysis 1(7), 1243-1257 (2009).
    • (2009) Bioanalysis , vol.1 , Issue.7 , pp. 1243-1257
    • Côté, C.1    Bergeron, A.2    Mess, J.-N.3    Furtado, M.4    Garofolo, F.5
  • 6
    • 77950787286 scopus 로고    scopus 로고
    • Selection of HILIC columns to handle matrix effect due to phospholipids
    • Mess J-N, Côté C, Bergeron A, Furado M, Garofolo F. Selection of HILIC columns to handle matrix effect due to phospholipids. Bioanalysis 1(1), 57-62 (2009).
    • (2009) Bioanalysis , vol.1 , Issue.1 , pp. 57-62
    • Mess, J.-N.1    Côté, C.2    Bergeron, A.3    Furado, M.4    Garofolo, F.5
  • 7
    • 80053251221 scopus 로고    scopus 로고
    • Impact of sample hemolysis on drug stability in regulated bioanalysis
    • Bérubé E-R, Taillon M-P, Furtado M, Garofolo F. Impact of sample hemolysis on drug stability in regulated bioanalysis. Bioanalysis 3(18), 2097-2105 (2011).
    • (2011) Bioanalysis , vol.3 , Issue.18 , pp. 2097-2105
    • Bérubé, E.-R.1    Taillon, M.-P.2    Furtado, M.3    Garofolo, F.4
  • 8
    • 84879638597 scopus 로고    scopus 로고
    • Severe impact of hemolysis on stability of phenolic compounds
    • Bérubé E-R, Lacasse M-C, Furtado M, Garofolo F. Severe impact of hemolysis on stability of phenolic compounds. Bioanalysis 5(12), 1491-1499 (2013).
    • (2013) Bioanalysis , vol.5 , Issue.12 , pp. 1491-1499
    • Bérubé, E.-R.1    Lacasse, M.-C.2    Furtado, M.3    Garofolo, F.4
  • 9
    • 84885217274 scopus 로고    scopus 로고
    • Impact of organic solvent additive on the integrity of plasma samples in bioanalysis by LC-MS/MS
    • Dicaire C, Mess J-N, Furtado M, Bergeron A, Garofolo F. Impact of organic solvent additive on the integrity of plasma samples in bioanalysis by LC-MS/MS. Bioanalysis 5(19), 2359-2370 (2013).
    • (2013) Bioanalysis , vol.5 , Issue.19 , pp. 2359-2370
    • Dicaire, C.1    Mess, J.-N.2    Furtado, M.3    Bergeron, A.4    Garofolo, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.