메뉴 건너뛰기




Volumn 121, Issue 8, 2013, Pages 410-414

Application of the thinprep imaging system in urine cytology :A prospective study

Author keywords

Accuracy; Cytology; Quality; Sensitivity; Specificity; Thinprep imager system; Urine

Indexed keywords

ARTICLE; BLADDER BIOPSY; BLADDER CARCINOMA; BLADDER TUMOR; CANCER SCREENING; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; GOLD STANDARD; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; IMAGING SYSTEM; INTERMETHOD COMPARISON; INVASIVE UROTHELIAL CARCINOMA; KIDNEY CARCINOMA; MAJOR CLINICAL STUDY; NONHODGKIN LYMPHOMA; NONINVASIVE PAPILLARY UROTHELIAL CANCER; PREDICTIVE VALUE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RELIABILITY; SENSITIVITY AND SPECIFICITY; SMALL CELL CARCINOMA; SQUAMOUS CELL CARCINOMA; URINALYSIS; URINE CYTOLOGY; UROTHELIAL CARCINOMA IN SITU; UROTHELIAL DYSPLASIA;

EID: 84885072344     PISSN: None     EISSN: 19346638     Source Type: Journal    
DOI: 10.1002/cncy.21301     Document Type: Article
Times cited : (11)

References (16)
  • 1
    • 34447550058 scopus 로고    scopus 로고
    • Accuracy of reading liquid based cytology slides used the thinprep imager compared with conventional cytology: Prospective study
    • Davey E, d'Assunco J, Irwig L, et al. Accuracy of reading liquid based cytology slides used the ThinPrep Imager compared with conventional cytology: prospective study. BMJ. 2007;335:31.
    • (2007) BMJ , vol.335 , pp. 31
    • Davey, E.1    D'Assunco, J.2    Irwig, L.3
  • 2
    • 84855933890 scopus 로고    scopus 로고
    • Utility of the thinprep imaging system in the detection of squamous intraepithelial abnormalities on retrospective evaluation: Can we trust the imager?
    • Barroeta J, Reilly ME, Steinhoff MM, Lawrence W. Utility of the ThinPrep Imaging System in the detection of squamous intraepithelial abnormalities on retrospective evaluation: can we trust the imager? Diagn Cytopathol. 2012;40:124-127.
    • (2012) Diagn Cytopathol , vol.40 , pp. 124-127
    • Barroeta, J.1    Reilly, M.E.2    Steinhoff, M.M.3    Lawrence, W.4
  • 4
    • 69849104507 scopus 로고    scopus 로고
    • Implementation of the thin prep imaging system in a tertiary military medical center
    • Duby JM, DiFurio MJ. Implementation of the Thin Prep Imaging System in a tertiary military medical center. Cancer (Cancer Cytopathol). 2009;117:264-270.
    • (2009) Cancer (Cancer Cytopathol) , vol.117 , pp. 264-270
    • Duby, J.M.1    Difurio, M.J.2
  • 5
    • 52249099239 scopus 로고    scopus 로고
    • Concordance between original screening and final diagnosis using imager vs manual screen of cervical liquid-based cytology slides
    • Pacheco MC, Conley RC, Pennington DW, Bishop JW. Concordance between original screening and final diagnosis using imager vs manual screen of cervical liquid-based cytology slides. Acta Cytol. 2008;52:575-578.
    • (2008) Acta Cytol , vol.52 , pp. 575-578
    • Pacheco, M.C.1    Conley, R.C.2    Pennington, D.W.3    Bishop, J.W.4
  • 6
    • 39749157862 scopus 로고    scopus 로고
    • Effectiveness of the ThinPrep Imaging System: Clinical experience in a low risk screening population
    • DOI 10.1002/dc.20779
    • Papillo JL, John TL, Leiman G. Effectiveness of the ThinPrep Imaging System: clinical experience in a low risk screening population. Diagn Cytopathol. 2008;36:155-160. (Pubitemid 351312129)
    • (2008) Diagnostic Cytopathology , vol.36 , Issue.3 , pp. 155-160
    • Papillo, J.L.1    St. John, T.L.2    Leiman, G.3
  • 7
    • 33846005864 scopus 로고    scopus 로고
    • Comparison of computer-assisted and manual screening of cervical cytology
    • DOI 10.1016/j.ygyno.2006.07.025, PII S0090825806005531
    • Lozano R. Comparison of computer-assisted and manual screening of cervical cytology. Gynecol Oncol. 2007;104:134-138. (Pubitemid 46054112)
    • (2007) Gynecologic Oncology , vol.104 , Issue.1 , pp. 134-138
    • Lozano, R.1
  • 8
    • 34249676290 scopus 로고    scopus 로고
    • Automated screening versus manual screening: A comparison of the ThinPrep imaging system and manual screening in a time study
    • DOI 10.1002/dc.20640
    • Schledermann D, Hyldebrandt T, Ejersbo D, Hoelund B. Automated screening versus manual screening: A comparison of the ThinPrep imaging system and manual screening in a time study. Diagn Cytopathol. 2007;35:348-352. (Pubitemid 46835025)
    • (2007) Diagnostic Cytopathology , vol.35 , Issue.6 , pp. 348-352
    • Schledermann, D.1    Hyldebrandt, T.2    Ejersbo, D.3    Hoelund, B.4
  • 10
    • 68849125825 scopus 로고    scopus 로고
    • A comparison of screening times between the thinprep imager and conventional cytology
    • Boost T. A comparison of screening times between the ThinPrep Imager and conventional cytology. Diagn Cytopathol. 2009;37: 661-664.
    • (2009) Diagn Cytopathol , vol.37 , pp. 661-664
    • Boost, T.1
  • 11
    • 34047111290 scopus 로고    scopus 로고
    • Implementation of the ThinPrep imaging system in a high-volume metropolitan laboratory
    • DOI 10.1002/dc.20627
    • Miller FS, Nagel LE, Kenny-Moynihan MB. Implementation of the ThinPrep imaging system in a high-volume metropolitan laboratory. Diagn Cytopathol. 2007;35:213-217. (Pubitemid 46516675)
    • (2007) Diagnostic Cytopathology , vol.35 , Issue.4 , pp. 213-217
    • Miller, F.S.1    Nagel, L.E.2    Kenny-Moynihan, M.B.3
  • 13
    • 33847219272 scopus 로고    scopus 로고
    • Introduction of the thin- prep imaging system (TIS): Experience in a high volume academic practice
    • Chivukula M, Saad RS, Elishaev E, et al. Introduction of the Thin- Prep Imaging System (TIS): experience in a high volume academic practice. Cytojournal. 2007;4:6.
    • (2007) Cytojournal , vol.4 , pp. 6
    • Chivukula, M.1    Saad, R.S.2    Elishaev, E.3
  • 14
    • 77951740961 scopus 로고    scopus 로고
    • Comparison of the sensitivity of conventional cytology and the thin prep imaging system for 1083 biopsy confirmed high-grade squamous lesions
    • Halford JA, Batty T, Boost T, et al. Comparison of the sensitivity of conventional cytology and the ThinPrep Imaging System for 1083 biopsy confirmed high-grade squamous lesions. Diag Cytopathol. 2010;38:318-326.
    • (2010) Diag Cytopathol , vol.38 , pp. 318-326
    • Halford, J.A.1    Batty, T.2    Boost, T.3
  • 16
    • 84885072620 scopus 로고    scopus 로고
    • Hologic thinprep imaging system for routine urine screening: Evaluation of screening time and diagnostic comparison
    • Abstract 364
    • Ferraro K, Kanaracus A, Kurian EM. Hologic ThinPrep Imaging System for routine urine screening: evaluation of screening time and diagnostic comparison. Mod Pathol. 2012;25(suppl 2):89A. Abstract 364.
    • (2012) Mod Pathol , vol.25 , Issue.SUPPL. 2
    • Ferraro, K.1    Kanaracus, A.2    Kurian, E.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.