메뉴 건너뛰기




Volumn 17, Issue 9, 2013, Pages 2381-2389

Pt nanoparticles modified Au nanowire array for amperometric and potentiometric detection of glucose

Author keywords

Au nanowire arrays; Electrochemical detection; Glucose biosensor; Pt nanoparticles

Indexed keywords

AMPEROMETRIC DETECTION; AU NANOWIRES; ELECTROCHEMICAL CATALYTIC ACTIVITIES; ELECTROCHEMICAL DETECTION; GLUCOSE BIOSENSOR; GLUCOSE OXIDASES (GOX); POTENTIOMETRIC DETECTION; PT NANOPARTICLES;

EID: 84885051742     PISSN: 14328488     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10008-013-2097-0     Document Type: Article
Times cited : (9)

References (33)
  • 1
    • 1342328051 scopus 로고    scopus 로고
    • Continuous glucose monitoring using enzyme-immobilized platinized diamond microfiber electrodes
    • 10.1016/j.electacta.2003.10.026 1:CAS:528:DC%2BD2cXhs1Ckt74%3D
    • Olivia H, Sarada BV, Honda K, Fujishima A (2004) Continuous glucose monitoring using enzyme-immobilized platinized diamond microfiber electrodes. Electrochim Acta 49:2069-2076
    • (2004) Electrochim Acta , vol.49 , pp. 2069-2076
    • Olivia, H.1    Sarada, B.V.2    Honda, K.3    Fujishima, A.4
  • 2
    • 63649149974 scopus 로고    scopus 로고
    • Detection of glucose based on direct electron transfer reaction of glucose oxidase immobilized on highly ordered polyaniline nanotubes
    • 10.1021/ac802421h 1:CAS:528:DC%2BD1MXhtVaru70%3D
    • Wang ZY, Liu SN, Wu P, Cai CX (2009) Detection of glucose based on direct electron transfer reaction of glucose oxidase immobilized on highly ordered polyaniline nanotubes. Anal Chem 81:1638-1645
    • (2009) Anal Chem , vol.81 , pp. 1638-1645
    • Wang, Z.Y.1    Liu, S.N.2    Wu, P.3    Cai, C.X.4
  • 4
    • 65249157380 scopus 로고    scopus 로고
    • Carbon nanotube-filled nanofibrous membranes electrospun from poly (acrylonitrile-co-acrylic acid) for glucose biosensor
    • 10.1021/jp807047s 1:CAS:528:DC%2BD1MXpsl2itg%3D%3D
    • Wang ZG, Wang Y, Xu H, Li G, Xu ZK (2009) Carbon nanotube-filled nanofibrous membranes electrospun from poly (acrylonitrile-co-acrylic acid) for glucose biosensor. J Phys Chem C 113:2955-2960
    • (2009) J Phys Chem C , vol.113 , pp. 2955-2960
    • Wang, Z.G.1    Wang, Y.2    Xu, H.3    Li, G.4    Xu, Z.K.5
  • 5
    • 77956241335 scopus 로고    scopus 로고
    • Pulse-voltammetric glucose detection at gold junction electrodes
    • 10.1021/ac101303s 1:CAS:528:DC%2BC3cXpvVGnsL4%3D
    • Rassaei L, Marken F (2010) Pulse-voltammetric glucose detection at gold junction electrodes. Anal Chem 82:7063-7067
    • (2010) Anal Chem , vol.82 , pp. 7063-7067
    • Rassaei, L.1    Marken, F.2
  • 6
    • 5644261411 scopus 로고    scopus 로고
    • A glucose biosensor based on chitosan-glucose oxidase-gold nanoparticles biocomposite formed by one-step electrodeposition [J]
    • 10.1016/j.ab.2004.07.005 1:CAS:528:DC%2BD2cXos1Kls7c%3D
    • Luo XL, Xu JJ, Du Y (2004) A glucose biosensor based on chitosan-glucose oxidase-gold nanoparticles biocomposite formed by one-step electrodeposition [J]. Anal Biochem 334:284-289
    • (2004) Anal Biochem , vol.334 , pp. 284-289
    • Luo, X.L.1    Xu, J.J.2    Du, Y.3
  • 7
    • 0242469052 scopus 로고    scopus 로고
    • Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode [J]
    • 10.1016/S0956-5663(03)00172-6 1:CAS:528:DC%2BD3sXovVWltLg%3D
    • Liu SQ, Ju HX (2003) Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode [J]. Biosens Bioelectron 19:177-183
    • (2003) Biosens Bioelectron , vol.19 , pp. 177-183
    • Liu, S.Q.1    Ju, H.X.2
  • 8
    • 10644220482 scopus 로고    scopus 로고
    • Glucose biosensor based on self-assembled gold nanoparticles and double-layer 2d-network (3-mercaptopropyl)-trimethoxysilane polymer onto gold substrate [J]
    • 10.1016/j.snb.2004.04.114 1:CAS:528:DC%2BD2cXhtVWju7rK
    • Zhong X, Yuan R, Chai YQ (2005) Glucose biosensor based on self-assembled gold nanoparticles and double-layer 2d-network (3-mercaptopropyl)- trimethoxysilane polymer onto gold substrate [J]. Sensor Actuat B 104:191-198
    • (2005) Sensor Actuat B , vol.104 , pp. 191-198
    • Zhong, X.1    Yuan, R.2    Chai, Y.Q.3
  • 9
    • 0345376728 scopus 로고    scopus 로고
    • A novel glucose sensor system with Au nanoparticles based on microdialysis and coenzymes for continuous glucose monitoring [J]
    • 10.1016/j.sna.2003.08.009 1:CAS:528:DC%2BD3sXptlegtbk%3D
    • Pan M, Guo XS, Cai Q (2003) A novel glucose sensor system with Au nanoparticles based on microdialysis and coenzymes for continuous glucose monitoring [J]. Sensor Actuat A 108:258-262
    • (2003) Sensor Actuat A , vol.108 , pp. 258-262
    • Pan, M.1    Guo, X.S.2    Cai, Q.3
  • 10
    • 10044252909 scopus 로고    scopus 로고
    • Glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline [J]
    • 10.1016/j.bios.2004.04.024 1:CAS:528:DC%2BD2cXhtVKlur%2FO
    • Zhou HH, Chen H, Luo SL (2005) Glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline [J]. Biosens Bioelectron 20:1305-1311
    • (2005) Biosens Bioelectron , vol.20 , pp. 1305-1311
    • Zhou, H.H.1    Chen, H.2    Luo, S.L.3
  • 11
    • 0038371408 scopus 로고    scopus 로고
    • Characterization of platinum nanoparticle-embedded carbon film electrode and its detection of hydrogen peroxide [J]
    • 10.1021/ac026337w 1:CAS:528:DC%2BD3sXisFSku70%3D
    • You TY, Niwa O, Tomita M (2003) Characterization of platinum nanoparticle-embedded carbon film electrode and its detection of hydrogen peroxide [J]. Anal Chem 75:2080-2085
    • (2003) Anal Chem , vol.75 , pp. 2080-2085
    • You, T.Y.1    Niwa, O.2    Tomita, M.3
  • 12
    • 76649144500 scopus 로고    scopus 로고
    • Nanoparticulate functional materials [J]
    • 10.1002/anie.200903053 1:CAS:528:DC%2BC3cXitVWjtL8%3D
    • Goesmann H, Feldmann C (2010) Nanoparticulate functional materials [J]. Angew Chem Int Ed 49:1362-1395
    • (2010) Angew Chem Int Ed , vol.49 , pp. 1362-1395
    • Goesmann, H.1    Feldmann, C.2
  • 13
    • 76749093968 scopus 로고    scopus 로고
    • Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging [J]
    • 10.1016/j.addr.2009.11.002 1:CAS:528:DC%2BC3cXit1Ont7s%3D
    • Veiseh O, Gunn JW, Zhang MQ (2010) Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging [J]. Adv Drug Delivery Rev 62:284-304
    • (2010) Adv Drug Delivery Rev , vol.62 , pp. 284-304
    • Veiseh, O.1    Gunn, J.W.2    Zhang, M.Q.3
  • 14
    • 10044258525 scopus 로고    scopus 로고
    • Integrated nanoparticle-biomolecule hybrid system: Synthesis, properties, and applications [J]
    • 10.1002/anie.200400651 1:CAS:528:DC%2BD2cXhtVKgsr3P
    • Katz E, Willner I (2004) Integrated nanoparticle-biomolecule hybrid system: synthesis, properties, and applications [J]. Angew Chem Int Ed 43:6042-6108
    • (2004) Angew Chem Int Ed , vol.43 , pp. 6042-6108
    • Katz, E.1    Willner, I.2
  • 15
    • 73449131471 scopus 로고    scopus 로고
    • Aptamer based electrochemical assay for the determination of thrombin by using the amplification of the nanoparticles [J]
    • 10.1016/j.bios.2009.10.017 1:CAS:528:DC%2BC3cXktVWrsA%3D%3D
    • Ding CF, Ge Y, Lin JM (2010) Aptamer based electrochemical assay for the determination of thrombin by using the amplification of the nanoparticles [J]. Biosens Bioelectron 25:1290-1294
    • (2010) Biosens Bioelectron , vol.25 , pp. 1290-1294
    • Ding, C.F.1    Ge, Y.2    Lin, J.M.3
  • 16
    • 54749138351 scopus 로고    scopus 로고
    • Semiconductor quantum dots for bioanalysis [J]
    • 10.1002/anie.200800169 1:CAS:528:DC%2BD1cXht1GltLzK
    • Gill R, Zayats M, Willner I (2008) Semiconductor quantum dots for bioanalysis [J]. Angew Chem Int Ed 47:7602-7625
    • (2008) Angew Chem Int Ed , vol.47 , pp. 7602-7625
    • Gill, R.1    Zayats, M.2    Willner, I.3
  • 17
    • 77952692145 scopus 로고    scopus 로고
    • A single ZnO nanofiber-based highly sensitive amperometric glucose biosensor [J]
    • 10.1021/jp102505g 1:CAS:528:DC%2BC3cXlsFWrtLc%3D
    • Ahmad M, Pan CF, Luo ZX, Zhu J (2010) A single ZnO nanofiber-based highly sensitive amperometric glucose biosensor [J]. J Phys Chem C 114:9308-9313
    • (2010) J Phys Chem C , vol.114 , pp. 9308-9313
    • Ahmad, M.1    Pan, C.F.2    Luo, Z.X.3    Zhu, J.4
  • 18
    • 38049153063 scopus 로고    scopus 로고
    • Simple fabrication of a highly sensitive glucose biosensor using enzymes immobilized in exfoliated graphite nanoplatelets nafion membrane [J]
    • 10.1021/cm702133u 1:CAS:528:DC%2BD2sXhtlSkurjJ
    • Lu J, Drzal LT, Worden RM, Lee I (2007) Simple fabrication of a highly sensitive glucose biosensor using enzymes immobilized in exfoliated graphite nanoplatelets nafion membrane [J]. Chem Mater 19:6240-6246
    • (2007) Chem Mater , vol.19 , pp. 6240-6246
    • Lu, J.1    Drzal, L.T.2    Worden, R.M.3    Lee, I.4
  • 19
    • 33644613273 scopus 로고    scopus 로고
    • Application of nanoparticles in electrochemical sensors and biosensors [J]
    • 10.1002/elan.200503415 1:CAS:528:DC%2BD28XitFCgtbw%3D
    • Luo XL, Morrin A, Killard AJ, Smyth MR (2006) Application of nanoparticles in electrochemical sensors and biosensors [J]. Electroanal 18:319-326
    • (2006) Electroanal , vol.18 , pp. 319-326
    • Luo, X.L.1    Morrin, A.2    Killard, A.J.3    Smyth, M.R.4
  • 20
    • 70349253893 scopus 로고    scopus 로고
    • Gold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection [J]
    • 10.1016/j.snb.2009.07.023 1:CAS:528:DC%2BD1MXhtF2hsrjF
    • Cherevko S, Chung CH (2009) Gold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection [J]. Sensor Actuat B-Chem 142:216-223
    • (2009) Sensor Actuat B-Chem , vol.142 , pp. 216-223
    • Cherevko, S.1    Chung, C.H.2
  • 21
    • 34848875708 scopus 로고    scopus 로고
    • Direct electrochemistry of hemoglobin in gold nanowire array [J]
    • 10.1016/j.bios.2007.05.003 1:CAS:528:DC%2BD2sXhtFelsrfK
    • Yang MH, Qu FL, Li YJ, He Y, Shen GL, Yu RQ (2007) Direct electrochemistry of hemoglobin in gold nanowire array [J]. Biosens Bioelectron 23:414-420
    • (2007) Biosens Bioelectron , vol.23 , pp. 414-420
    • Yang, M.H.1    Qu, F.L.2    Li, Y.J.3    He, Y.4    Shen, G.L.5    Yu, R.Q.6
  • 22
    • 57649149084 scopus 로고    scopus 로고
    • Structural characterisation of gold nanowire arrays [J]
    • 10.1016/j.jcrysgro.2008.10.022 1:CAS:528:DC%2BD1cXhsFaht7vL
    • Milenkovic S, Nakayama T, Rohwerder M, Hassel AW (2008) Structural characterisation of gold nanowire arrays [J]. J Cryst Growth 311:194-199
    • (2008) J Cryst Growth , vol.311 , pp. 194-199
    • Milenkovic, S.1    Nakayama, T.2    Rohwerder, M.3    Hassel, A.W.4
  • 23
    • 77955273580 scopus 로고    scopus 로고
    • A study on the kinetics of gold nanowire electrodeposition in polycarbonate templates [J]
    • 10.1016/j.jelechem.2010.04.007 1:CAS:528:DC%2BC3cXms1eks7k%3D
    • Soleimany L, Dolati A, Ghorbani M (2010) A study on the kinetics of gold nanowire electrodeposition in polycarbonate templates [J]. J Electroanal Chem 645:28-34
    • (2010) J Electroanal Chem , vol.645 , pp. 28-34
    • Soleimany, L.1    Dolati, A.2    Ghorbani, M.3
  • 24
    • 70349230816 scopus 로고    scopus 로고
    • Glucose biosensor based on immobilization of glucose oxidase in platinum nanoparticles/graphene/chitosan nanocomposite film [J]
    • 10.1016/j.talanta.2009.06.054 1:CAS:528:DC%2BD1MXhtF2hsbjI
    • Wu H, Wang J, Kang XH, Wang CM, Wang DH, Liu J, Aksay IA, Lin YH (2009) Glucose biosensor based on immobilization of glucose oxidase in platinum nanoparticles/graphene/chitosan nanocomposite film [J]. Talanta 80:403-406
    • (2009) Talanta , vol.80 , pp. 403-406
    • Wu, H.1    Wang, J.2    Kang, X.H.3    Wang, C.M.4    Wang, D.H.5    Liu, J.6    Aksay, I.A.7    Lin, Y.H.8
  • 25
    • 79959227053 scopus 로고    scopus 로고
    • ZnO nanorods/Au hybrid nanocomposites for glucose biosensor[J]
    • 10.1016/j.bios.2010.06.006 1:CAS:528:DC%2BC3cXhtFGht77E
    • Wei YY, Li Y, Liu XQ, Xian YZ, Shi GY, Jin LT (2010) ZnO nanorods/Au hybrid nanocomposites for glucose biosensor[J]. Biosens Bioelectron 26:275-278
    • (2010) Biosens Bioelectron , vol.26 , pp. 275-278
    • Wei, Y.Y.1    Li, Y.2    Liu, X.Q.3    Xian, Y.Z.4    Shi, G.Y.5    Jin, L.T.6
  • 26
    • 18744401668 scopus 로고    scopus 로고
    • Highly ordered platinum-nanotubule arrays for amperometric glucose sensing [J]
    • 10.1002/adfm.200400321 1:CAS:528:DC%2BD2MXktlSktbg%3D
    • Yuan JH, Wang KW, Xia XH (2005) Highly ordered platinum-nanotubule arrays for amperometric glucose sensing [J]. Adv Funct Mater 15:803-809
    • (2005) Adv Funct Mater , vol.15 , pp. 803-809
    • Yuan, J.H.1    Wang, K.W.2    Xia, X.H.3
  • 27
    • 52649139485 scopus 로고    scopus 로고
    • Active Pt nanoparticles stabilized with glucose oxidase [J]
    • 10.1021/jp800779c 1:CAS:528:DC%2BD1cXpslahtbc%3D
    • Karam P, Xin Y, Jaber S, Halaoui LI (2008) Active Pt nanoparticles stabilized with glucose oxidase [J]. J Phys Chem C 112:13846-13850
    • (2008) J Phys Chem C , vol.112 , pp. 13846-13850
    • Karam, P.1    Xin, Y.2    Jaber, S.3    Halaoui, L.I.4
  • 28
    • 68749088578 scopus 로고    scopus 로고
    • Pt nanoparticles inserting in carbon nanotube arrays: Nanocomposites for glucose biosensors [J]
    • 10.1021/jp902830z 1:CAS:528:DC%2BD1MXosVWnurk%3D
    • Wen ZH, Ci SQ, Li JH (2009) Pt nanoparticles inserting in carbon nanotube arrays: nanocomposites for glucose biosensors [J]. J Phys Chem C 113:13482-13487
    • (2009) J Phys Chem C , vol.113 , pp. 13482-13487
    • Wen, Z.H.1    Ci, S.Q.2    Li, J.H.3
  • 29
    • 84869085765 scopus 로고    scopus 로고
    • Pt modified polypyrrole nanowires array biosensor for amperometric and potentiometric glucose detection [J]
    • 10.1016/j.aca.2012.09.037 1:CAS:528:DC%2BC38Xhs1aru7zN
    • Xu GQ, Adeloju SB, Wu YC, Zhang XY (2012) Pt modified polypyrrole nanowires array biosensor for amperometric and potentiometric glucose detection [J]. Anal Chim Acta 755:100-107
    • (2012) Anal Chim Acta , vol.755 , pp. 100-107
    • Xu, G.Q.1    Adeloju, S.B.2    Wu, Y.C.3    Zhang, X.Y.4
  • 30
    • 84862789155 scopus 로고    scopus 로고
    • A facile and efficient approach for pore-opening detection of anodic aluminum oxide membranes [J]
    • 10.1016/j.apsusc.2012.01.099 1:CAS:528:DC%2BC38Xjt1yitb0%3D
    • Cui JW, Wu YC, Wang Y, Zheng HM, Xu GQ, Zhang XY (2012) A facile and efficient approach for pore-opening detection of anodic aluminum oxide membranes [J]. Appl Surf Sci 258:5305-5311
    • (2012) Appl Surf Sci , vol.258 , pp. 5305-5311
    • Cui, J.W.1    Wu, Y.C.2    Wang, Y.3    Zheng, H.M.4    Xu, G.Q.5    Zhang, X.Y.6
  • 31
    • 79952490423 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on integration of glucose oxidase with platinum nanoparticles/mesoporous carbon nanocomposite [J]
    • 10.1016/j.snb.2010.10.023 1:CAS:528:DC%2BC3MXjtVKmtrc%3D
    • Jiang XY, Wu YH, Mao XY (2011) Amperometric glucose biosensor based on integration of glucose oxidase with platinum nanoparticles/mesoporous carbon nanocomposite [J]. Sensor Actuat B-Chem 153:158-163
    • (2011) Sensor Actuat B-Chem , vol.153 , pp. 158-163
    • Jiang, X.Y.1    Wu, Y.H.2    Mao, X.Y.3
  • 32
    • 80052265104 scopus 로고    scopus 로고
    • ZnO nanoparticle and multiwalled carbon nanotubes for glucose oxidase direct electron transfer and electrocatalytic activity investigation [J]
    • 10.1016/j.molcatb.2011.07.005 1:CAS:528:DC%2BC3MXhtV2ntbrK
    • Hu F, Chen S, Wang C, Yuan R, Chai Y, Xiang Y, Wang C (2011) ZnO nanoparticle and multiwalled carbon nanotubes for glucose oxidase direct electron transfer and electrocatalytic activity investigation [J]. Molecular Catalysis B 72:298-304
    • (2011) Molecular Catalysis B , vol.72 , pp. 298-304
    • Hu, F.1    Chen, S.2    Wang, C.3    Yuan, R.4    Chai, Y.5    Xiang, Y.6    Wang, C.7
  • 33
    • 59449086097 scopus 로고    scopus 로고
    • Direct electrodeposition of porous gold nanowire arrays for biosensing applications [J]
    • 10.1002/cphc.200800538 1:CAS:528:DC%2BD1MXit1WhtLo%3D
    • Zhang XY, Li D, Bourgeois L (2009) Direct electrodeposition of porous gold nanowire arrays for biosensing applications [J]. ChemPhysChem 10:436-441
    • (2009) ChemPhysChem , vol.10 , pp. 436-441
    • Zhang, X.Y.1    Li, D.2    Bourgeois, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.