메뉴 건너뛰기




Volumn 37, Issue 4, 2013, Pages 605-610

Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up

Author keywords

[No Author keywords available]

Indexed keywords

BONE CEMENT;

EID: 84885050159     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-013-1818-4     Document Type: Article
Times cited : (15)

References (27)
  • 1
    • 33745948305 scopus 로고    scopus 로고
    • Acetabular reconstruction with impacted bone allografts and cemented acetabular components. A 2- to 13-year follow-up study of 142 aseptic revisions
    • 16798986 10.1302/0301-620X.88B7.17227 1:STN:280:DC%2BD28zotFyhsQ%3D%3D
    • Comba F, Buttaro M, Pusso R, Piccaluga F (2006) Acetabular reconstruction with impacted bone allografts and cemented acetabular components. A 2- to 13-year follow-up study of 142 aseptic revisions. J Bone Joint Surg Br 88:865-869
    • (2006) J Bone Joint Surg Br , vol.88 , pp. 865-869
    • Comba, F.1    Buttaro, M.2    Pusso, R.3    Piccaluga, F.4
  • 2
    • 78649329690 scopus 로고    scopus 로고
    • The survival and fate of acetabular reconstruction with impaction grafting for large defects
    • 20499294 10.1007/s11999-010-1395-4
    • Garcia-Cimbrelo E, Cruz-Pardos A, Garcia-Rey E, Ortega-Chamarro J (2010) The survival and fate of acetabular reconstruction with impaction grafting for large defects. Clin Orthop Relat Res 468:3304-3313
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 3304-3313
    • Garcia-Cimbrelo, E.1    Cruz-Pardos, A.2    Garcia-Rey, E.3    Ortega-Chamarro, J.4
  • 3
    • 0037354113 scopus 로고    scopus 로고
    • Failure of an uncemented non-porous metal-backed prosthesis with augmentation using impacted allograft for acetabular revision. 12- to 17-year results
    • 12678349 10.1302/0301-620X.85B2.13249 1:STN:280:DC%2BD3s7mtFWiuw%3D%3D
    • Jeffery M, Scott G, Freeman M (2003) Failure of an uncemented non-porous metal-backed prosthesis with augmentation using impacted allograft for acetabular revision. 12- to 17-year results. J Bone Joint Surg Br 85:182-186
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 182-186
    • Jeffery, M.1    Scott, G.2    Freeman, M.3
  • 4
    • 33846871948 scopus 로고    scopus 로고
    • Revision total hip replacement using the Kerboull acetabular reinforcement device with morsellised or bulk graft
    • 17259411 10.1302/0301-620X.89B1.18037 1:STN:280:DC%2BD2s%2FlsFSktQ%3D%3D
    • Kawanabe K, Akiyama H, Onishi E, Nakamura T (2007) Revision total hip replacement using the Kerboull acetabular reinforcement device with morsellised or bulk graft. J Bone Joint Surg Br 89:26-31
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 26-31
    • Kawanabe, K.1    Akiyama, H.2    Onishi, E.3    Nakamura, T.4
  • 5
    • 77953122271 scopus 로고    scopus 로고
    • Revision with impacted bone allografts and the Kerboull cross plate for massive bone defect of the acetabulum
    • 19493654 10.1016/j.arth.2009.04.003
    • Okano K, Miyata N, Enomoto H, Osaki M, Shindo H (2010) Revision with impacted bone allografts and the Kerboull cross plate for massive bone defect of the acetabulum. J Arthroplasty 25:594-599
    • (2010) J Arthroplasty , vol.25 , pp. 594-599
    • Okano, K.1    Miyata, N.2    Enomoto, H.3    Osaki, M.4    Shindo, H.5
  • 6
    • 0031026881 scopus 로고    scopus 로고
    • Hydroxyapatite in revision of total hip replacements with massive acetabular defects
    • 9020452 10.1302/0301-620X.79B1.1290 1:STN:280:DyaK2s7nt1elug%3D%3D
    • Oonishi H, Iwaki Y, Kin N, Kushitani S, Murata N, Wakitani S, Imoto K (1997) Hydroxyapatite in revision of total hip replacements with massive acetabular defects. J Bone Joint Surg Br 79:87-92
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 87-92
    • Oonishi, H.1    Iwaki, Y.2    Kin, N.3    Kushitani, S.4    Murata, N.5    Wakitani, S.6    Imoto, K.7
  • 7
    • 77956363425 scopus 로고    scopus 로고
    • Grafting with hydroxyapatite grannules for defects of acetabular bone at revision total hip replacement. A minimum ten-year follow-up
    • 20798437 1:STN:280:DC%2BC3cjnvVartw%3D%3D
    • Sakai T, Ohzono K, Nishii T, Miki H, Takao M, Sugano N (2010) Grafting with hydroxyapatite grannules for defects of acetabular bone at revision total hip replacement. A minimum ten-year follow-up. J Bone Joint Surg Br 92:1215-1221
    • (2010) J Bone Joint Surg Br , vol.92 , pp. 1215-1221
    • Sakai, T.1    Ohzono, K.2    Nishii, T.3    Miki, H.4    Takao, M.5    Sugano, N.6
  • 8
    • 62549088739 scopus 로고    scopus 로고
    • Acetabular revision with impacted morsellised cancellous bone grafting and a cemented acetabular component. A 20-to 25-year follow-up
    • 19721038 10.2106/JBJS.G.01701 1:STN:280:DC%2BD1MrptlOltg%3D%3D
    • Schreurs BW, Keurentjes JC, Gardeniers JWM, Verdonschot N, Slooff TJJH, Veth RPH (2009) Acetabular revision with impacted morsellised cancellous bone grafting and a cemented acetabular component. A 20-to 25-year follow-up. J Bone Joint Surg Br 91:1148-1153
    • (2009) J Bone Joint Surg Br , vol.91 , pp. 1148-1153
    • Schreurs, B.W.1    Keurentjes, J.C.2    Gardeniers, J.W.M.3    Verdonschot, N.4    Slooff, T.5    Veth, R.P.H.6
  • 9
    • 16844381918 scopus 로고    scopus 로고
    • The use of structural distal femoral allografts for acetabular reconstruction. Average 10-year follow-up
    • 15805204 10.2106/JBJS.D.02099
    • Sporer SM, O'Rourke M, Chong P, Paprosky WG (2005) The use of structural distal femoral allografts for acetabular reconstruction. Average 10-year follow-up. J Bone Joint Surg Am 87:760-765
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 760-765
    • Sporer, S.M.1    O'Rourke, M.2    Chong, P.3    Paprosky, W.G.4
  • 10
    • 34548381164 scopus 로고    scopus 로고
    • Acetabular reconstruction using a cementless cup and hydroxyapatite granules
    • 17826272 10.1016/j.arth.2006.09.011
    • Sudo A, Hasegawa M, Fukuda A, Kawamura G, Muraki M, Uchida A (2007) Acetabular reconstruction using a cementless cup and hydroxyapatite granules. J Arthroplasty 22:828-832
    • (2007) J Arthroplasty , vol.22 , pp. 828-832
    • Sudo, A.1    Hasegawa, M.2    Fukuda, A.3    Kawamura, G.4    Muraki, M.5    Uchida, A.6
  • 11
    • 0141869963 scopus 로고    scopus 로고
    • Acetabular reconstruction using a Kerboull-type acetabular reinforcement device and hydroxyapatite granules. A 3- to 8- year follow-up study
    • 14513444 10.1016/S0883-5403(03)00149-9
    • Tanaka C, Shikata J, Ikenaga M, Takahashi M (2003) Acetabular reconstruction using a Kerboull-type acetabular reinforcement device and hydroxyapatite granules. A 3- to 8- year follow-up study. J Arthroplasty 18:719-725
    • (2003) J Arthroplasty , vol.18 , pp. 719-725
    • Tanaka, C.1    Shikata, J.2    Ikenaga, M.3    Takahashi, M.4
  • 12
    • 34147109941 scopus 로고    scopus 로고
    • High rate of failure of impaction grafting in large acetabular defects
    • 17356137 10.1302/0301-620X.89B3.18080
    • van Haaren EH, Heyligers IC, Alexander FGM, Wuisman PIJM (2007) High rate of failure of impaction grafting in large acetabular defects. J Bone Joint Surg Br 89:296-300
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 296-300
    • Van Haaren, E.H.1    Heyligers, I.C.2    Alexander, F.G.M.3    Wuisman, P.4
  • 13
    • 33646822988 scopus 로고    scopus 로고
    • Acetabular revision with morsellised allogenic bone graft and a cemented metal-backed component
    • 16645102 10.1302/0301-620X.88B5.17275
    • Wang JW, Fong CY, Su YS, Yu HN (2006) Acetabular revision with morsellised allogenic bone graft and a cemented metal-backed component. J Bone Joint Surg Br 88:586-591
    • (2006) J Bone Joint Surg Br , vol.88 , pp. 586-591
    • Wang, J.W.1    Fong, C.Y.2    Su, Y.S.3    Yu, H.N.4
  • 14
    • 84876541047 scopus 로고    scopus 로고
    • Application and survival curve of total hip arthroplasties: A systematic comparative analysis using worldwide hip arthroplasty registers
    • 22911152 10.1007/s00264-012-1614-6
    • Sadoghi P, Schröder C, Fottner A, Steinbrück A, Betz O, Müller PE, Jansson V, Hölzer A (2012) Application and survival curve of total hip arthroplasties: a systematic comparative analysis using worldwide hip arthroplasty registers. Int Orthop 36:2197-2203
    • (2012) Int Orthop , vol.36 , pp. 2197-2203
    • Sadoghi, P.1    Schröder, C.2    Fottner, A.3    Steinbrück, A.4    Betz, O.5    Müller, P.E.6    Jansson, V.7    Hölzer, A.8
  • 15
    • 0028155886 scopus 로고
    • Acetabular defect classification and surgical reconstruction in revision arthroplasty: A six year follow-up evaluation
    • 8163974 10.1016/0883-5403(94)90135-X 1:STN:280:DyaK2c3hs1yluw%3D%3D
    • Paprosky WG, Perona PG, Lawrence JM (1994) Acetabular defect classification and surgical reconstruction in revision arthroplasty: a six year follow-up evaluation. J Arthroplasty 9:33-44
    • (1994) J Arthroplasty , vol.9 , pp. 33-44
    • Paprosky, W.G.1    Perona, P.G.2    Lawrence, J.M.3
  • 16
    • 83455170813 scopus 로고    scopus 로고
    • High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook
    • 22161919 10.1302/0301-620X.93B12.27299 1:STN:280:DC%2BC38%2Fnt1GksQ%3D%3D
    • Babis GC, Sakellariou VI, Chatziantoniou AN, Soucacos PN, Megas P (2011) High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook. J Bone Joint Surg Br 93:1592-1596
    • (2011) J Bone Joint Surg Br , vol.93 , pp. 1592-1596
    • Babis, G.C.1    Sakellariou, V.I.2    Chatziantoniou, A.N.3    Soucacos, P.N.4    Megas, P.5
  • 17
    • 84863777866 scopus 로고    scopus 로고
    • Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: A retrospective data analysis and review of the literature
    • 22202962 10.1007/s00264-011-1462-9
    • Friesenbichler J, Schwarzkopf R, Sadoghi P, Marwin SE, Glehr M, Maurer-Ertl W, Leithner A (2012) Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature. Int Orthop 36:993-998
    • (2012) Int Orthop , vol.36 , pp. 993-998
    • Friesenbichler, J.1    Schwarzkopf, R.2    Sadoghi, P.3    Marwin, S.E.4    Glehr, M.5    Maurer-Ertl, W.6    Leithner, A.7
  • 18
    • 72249110313 scopus 로고    scopus 로고
    • The management of severe acetabular bone defects in revision hip arthroplasty using modular porous metal components
    • 19949116 10.1302/0301-620X.91B12.22517 1:STN:280:DC%2BD1Mjpt1Chug%3D%3D
    • Lingaraj K, Teo YH, Bergman N (2009) The management of severe acetabular bone defects in revision hip arthroplasty using modular porous metal components. J Bone Joint Surg Br 91:1555-1560
    • (2009) J Bone Joint Surg Br , vol.91 , pp. 1555-1560
    • Lingaraj, K.1    Teo, Y.H.2    Bergman, N.3
  • 19
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty: An end-result study using a new method of result evaluation
    • 5783851 1:STN:280:DyaF1M3gtlWltQ%3D%3D
    • Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737-755
    • (1969) J Bone Joint Surg Am , vol.51 , pp. 737-755
    • Harris, W.H.1
  • 20
    • 20444365875 scopus 로고    scopus 로고
    • Reconstructed hip joints position and abductor muscle strength after total hip arthroplasty
    • 16124955 10.1016/j.arth.2004.01.016
    • Asayama I, Chamnongkich S, Simpson KJ, Kinsey TL, Mahoney OM (2005) Reconstructed hip joints position and abductor muscle strength after total hip arthroplasty. J Arthroplasty 20:414-420
    • (2005) J Arthroplasty , vol.20 , pp. 414-420
    • Asayama, I.1    Chamnongkich, S.2    Simpson, K.J.3    Kinsey, T.L.4    Mahoney, O.M.5
  • 21
    • 0024400553 scopus 로고
    • The measurement of migration of the acetabular component of hip prostheses
    • 2768311 1:STN:280:DyaL1MzlvFClsg%3D%3D
    • Nunn D, Freeman MAR, Hill PF, Evans SJW (1989) The measurement of migration of the acetabular component of hip prostheses. J Bone Joint Surg Br 71:629-631
    • (1989) J Bone Joint Surg Br , vol.71 , pp. 629-631
    • Nunn, D.1    Freeman, M.A.R.2    Hill, P.F.3    Evans, S.J.W.4
  • 22
    • 53649083045 scopus 로고    scopus 로고
    • Acetabular bone reconstruction in revision arthroplasty. A comparison of freeze-dried, irradiated and chemically-treated allograft vitalized with autologous marrow versus frozen non-irradiated allograft
    • 18757955 10.1302/0301-620X.90B9.20425 1:STN:280:DC%2BD1crntFOlug%3D%3D
    • Ochs BG, Schmid U, Rieth J, Ateschrang A, Weise K, Ochs U (2008) Acetabular bone reconstruction in revision arthroplasty. A comparison of freeze-dried, irradiated and chemically-treated allograft vitalized with autologous marrow versus frozen non-irradiated allograft. J Bone Joint Surg Br 90:1164-1171
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 1164-1171
    • Ochs, B.G.1    Schmid, U.2    Rieth, J.3    Ateschrang, A.4    Weise, K.5    Ochs, U.6
  • 23
    • 0017047304 scopus 로고
    • Radiographic demarcation of cemented sockets in total hip replacement
    • 991504
    • DeLee JG, Charnley J (1976) Radiographic demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20-32
    • (1976) Clin Orthop Relat Res , vol.121 , pp. 20-32
    • Delee, J.G.1    Charnley, J.2
  • 24
    • 0035644173 scopus 로고    scopus 로고
    • The abuse of power: The pervasive fallacy of power calculations for data analysis
    • 10.1198/000313001300339897
    • Hoenig JM, Heisey DM (2001) The abuse of power: the pervasive fallacy of power calculations for data analysis. Am Stat 55:19-24
    • (2001) Am Stat , vol.55 , pp. 19-24
    • Hoenig, J.M.1    Heisey, D.M.2
  • 25
    • 79955980177 scopus 로고    scopus 로고
    • The results of a press-fit-only technique for acetabular fixation in hip dysplasia
    • 20647158 10.1016/j.arth.2010.05.025
    • Takao M, Nakamura N, Ohzono K, Sakai T, Nishii T, Sugano N (2011) The results of a press-fit-only technique for acetabular fixation in hip dysplasia. J Arthroplasty 26:562-568
    • (2011) J Arthroplasty , vol.26 , pp. 562-568
    • Takao, M.1    Nakamura, N.2    Ohzono, K.3    Sakai, T.4    Nishii, T.5    Sugano, N.6
  • 26
    • 0036189274 scopus 로고    scopus 로고
    • Incorporation of morsellised bone grafts: A study of 24 acetabular biopsy specimens
    • 11859236 10.1097/00003086-200203000-00022
    • van der Donk S, Buma P, Slooff TJJH, Gardeniers JWM, Schreurs BW (2002) Incorporation of morsellised bone grafts: a study of 24 acetabular biopsy specimens. Clin Orthop Relat Res 396:131-141
    • (2002) Clin Orthop Relat Res , vol.396 , pp. 131-141
    • Van Der Donk, S.1    Buma, P.2    Slooff, T.3    Gardeniers, J.W.M.4    Schreurs, B.W.5
  • 27
    • 0034998169 scopus 로고    scopus 로고
    • Allogeneic cancellous bone graft and a Burch-Schneider ring for acetabular reconstruction in revision hip arthroplasty
    • 11407794
    • Winter E, Piert M, Volkmann R, Maurer F, Eingartner C, Weise K, Weller S (2001) Allogeneic cancellous bone graft and a Burch-Schneider ring for acetabular reconstruction in revision hip arthroplasty. J Bone Joint Surg Am 83:862-867
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 862-867
    • Winter, E.1    Piert, M.2    Volkmann, R.3    Maurer, F.4    Eingartner, C.5    Weise, K.6    Weller, S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.