Validation of a new method based on ultrasound velocity dilution to measure cardiac output in paediatric patients

Author keywords

Cardiac output; Cardiac surgery; Children; Monitoring; Ultrasound dilution

Indexed keywords

ARTERY CATHETER; ARTERY CATHETERIZATION; ARTICLE; BLOOD FLOW VELOCITY; CENTRAL VENOUS CATHETER; CONGENITAL HEART DISEASE; DILUTION; ECHOGRAPHY; EXTRACORPOREAL CIRCULATION; FEMORAL ARTERY; FICK EQUATION; GROUPS BY AGE; HEART INDEX; HEART OUTPUT; HEART OUTPUT MEASUREMENT; HEART SURGERY; HUMAN; INFANT; INTERMETHOD COMPARISON; INTRAVENOUS CATHETER; MAJOR CLINICAL STUDY; MASS SPECTROMETER; MATHEMATICAL COMPUTING; MEASUREMENT ERROR; NEWBORN; OXYGEN CONSUMPTION; POSTOPERATIVE PERIOD; QUADRUPOLE MASS SPECTROMETRY; RESPIRATORY MASS SPECTROMETRY; ULTRASOUND DILUTION; ULTRASOUND SCANNER; VALIDATION STUDY;

EID: 84885018452     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-013-2848-5     Document Type: Article
Times cited : (16)

References (28)
  • 1
    • 0028789940 scopus 로고
    • Postoperative course and hemodynamic profile after the arterial switch operation in neonates and infants. A comparison of low-flow cardiopulmonary bypass and circulatory arrest
    • 7554206 10.1161/01.CIR.92.8.2226 1:STN:280:DyaK28%2FhslejsA%3D%3D
    • Wernovsky G, Wypij D, Jonas RA, Mayer JE Jr, Hanley FL, Hickey PR, Walsh AZ, Chang AC, Castaneda AR, Newburger JW et al (1995) Postoperative course and hemodynamic profile after the arterial switch operation in neonates and infants. A comparison of low-flow cardiopulmonary bypass and circulatory arrest. Circulation 92:2226-2235
    • (1995) Circulation , vol.92 , pp. 2226-2235
    • Wernovsky, G.1    Wypij, D.2    Jonas, R.A.3    Mayer, Jr.J.E.4    Hanley, F.L.5    Hickey, P.R.6    Walsh, A.Z.7    Chang, A.C.8    Castaneda, A.R.9    Newburger, J.W.10
  • 2
    • 0000435778 scopus 로고
    • Estimation of cardiac output soon after intracardiac surgery with cardiopulmonary bypass
    • 13803517 10.1097/00000658-195910000-00007 1:STN:280:DyaF3c7itl2isA%3D%3D
    • Boyd AD, Tremblay RE, Spencer FC, Bahnson HT (1959) Estimation of cardiac output soon after intracardiac surgery with cardiopulmonary bypass. Ann Surg 150:613-626
    • (1959) Ann Surg , vol.150 , pp. 613-626
    • Boyd, A.D.1    Tremblay, R.E.2    Spencer, F.C.3    Bahnson, H.T.4
  • 3
    • 0033787516 scopus 로고    scopus 로고
    • Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit
    • 11126264 10.1007/s001340051347 1:STN:280:DC%2BD3M7htlegsw%3D%3D
    • Linton RA, Jonas MM, Tibby SM, Murdoch IA, O'Brien TK, Linton NW, Band DM (2000) Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit. Intensive Care Med 26:1507-1511
    • (2000) Intensive Care Med , vol.26 , pp. 1507-1511
    • Linton, R.A.1    Jonas, M.M.2    Tibby, S.M.3    Murdoch, I.A.4    O'Brien, T.K.5    Linton, N.W.6    Band, D.M.7
  • 4
    • 33845769558 scopus 로고    scopus 로고
    • Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery
    • 17198817 10.1016/j.jtcvs.2006.07.038 1:STN:280:DC%2BD2s%2FgtlantQ%3D%3D
    • Fakler U, Pauli C, Balling G, Lorenz HP, Eicken A, Hennig M, Hess J (2007) Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery. J Thorac Cardiovasc Surg 133:224-228
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 224-228
    • Fakler, U.1    Pauli, C.2    Balling, G.3    Lorenz, H.P.4    Eicken, A.5    Hennig, M.6    Hess, J.7
  • 5
    • 84855683066 scopus 로고    scopus 로고
    • Ultrasound dilution: An accurate means of determining cardiac output in children
    • 21499176 10.1097/PCC.0b013e3182196804
    • Crittendon I 3rd, Dreyer WJ, Decker JA, Kim JJ (2012) Ultrasound dilution: an accurate means of determining cardiac output in children. Pediatr Crit Care Med 13:42-46
    • (2012) Pediatr Crit Care Med , vol.13 , pp. 42-46
    • Crittendon III, I.1    Dreyer, W.J.2    Decker, J.A.3    Kim, J.J.4
  • 6
    • 80051596406 scopus 로고    scopus 로고
    • Validation of cardiac output measurement by ultrasound dilution technique with pulmonary artery thermodilution in a pediatric animal model
    • 21359950 10.1007/s00246-011-9915-x
    • Darling E, Thuramalla N, Searles B (2011) Validation of cardiac output measurement by ultrasound dilution technique with pulmonary artery thermodilution in a pediatric animal model. Pediatr Cardiol 32:585-589
    • (2011) Pediatr Cardiol , vol.32 , pp. 585-589
    • Darling, E.1    Thuramalla, N.2    Searles, B.3
  • 7
    • 78349252680 scopus 로고    scopus 로고
    • Flow-regulated extracorporeal arteriovenous tubing loop for cardiac output measurements by ultrasound velocity dilution: Validation in post-cardiac surgery intensive care unit patients
    • 21245798 10.1097/MAT.0b013e3181effdf8
    • Eremenko AA, Safarov PN (2010) Flow-regulated extracorporeal arteriovenous tubing loop for cardiac output measurements by ultrasound velocity dilution: validation in post-cardiac surgery intensive care unit patients. ASAIO J 56:522-526
    • (2010) ASAIO J , vol.56 , pp. 522-526
    • Eremenko, A.A.1    Safarov, P.N.2
  • 9
    • 10244267519 scopus 로고    scopus 로고
    • Negative-pressure ventilation improves cardiac output after right heart surgery
    • 8901719 1:STN:280:DyaK2s%2Flslersg%3D%3D
    • Shekerdemian LS, Shore DF, Lincoln C, Bush A, Redington AN (1996) Negative-pressure ventilation improves cardiac output after right heart surgery. Circulation 94:II49-II55
    • (1996) Circulation , vol.94
    • Shekerdemian, L.S.1    Shore, D.F.2    Lincoln, C.3    Bush, A.4    Redington, A.N.5
  • 10
    • 0018419014 scopus 로고
    • The measurement of metabolic gas exchange and minute volume by mass spectrometry alone
    • 441578 10.1016/0034-5687(79)90029-X 1:STN:280:DyaE1M7otFCjsQ%3D%3D
    • Davies NJ, Denison DM (1979) The measurement of metabolic gas exchange and minute volume by mass spectrometry alone. Respir Physiol 36:261-267
    • (1979) Respir Physiol , vol.36 , pp. 261-267
    • Davies, N.J.1    Denison, D.M.2
  • 11
    • 0345374592 scopus 로고    scopus 로고
    • Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial
    • 14645314 10.1001/jama.290.20.2713 1:CAS:528:DC%2BD3sXpsVars74%3D
    • Richard C, Warszawski J, Anguel N, Deye N, Combes A, Barnoud D, Boulain T, Lefort Y, Fartoukh M, Baud F, Boyer A, Brochard L, Teboul JL (2003) Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA 290:2713-2720
    • (2003) JAMA , vol.290 , pp. 2713-2720
    • Richard, C.1    Warszawski, J.2    Anguel, N.3    Deye, N.4    Combes, A.5    Barnoud, D.6    Boulain, T.7    Lefort, Y.8    Fartoukh, M.9    Baud, F.10    Boyer, A.11    Brochard, L.12    Teboul, J.L.13
  • 12
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
    • 16084255 10.1016/S0140-6736(05)67061-4
    • Harvey S, Harrison DA, Singer M, Ashcroft J, Jones CM, Elbourne D, Brampton W, Williams D, Young D, Rowan K (2005) Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 366:472-477
    • (2005) Lancet , vol.366 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3    Ashcroft, J.4    Jones, C.M.5    Elbourne, D.6    Brampton, W.7    Williams, D.8    Young, D.9    Rowan, K.10
  • 13
    • 26044478155 scopus 로고    scopus 로고
    • Impact of the pulmonary artery catheter in critically ill patients: Meta-analysis of randomized clinical trials
    • 16204666 10.1001/jama.294.13.1664 1:CAS:528:DC%2BD2MXhtVOqtLrP
    • Shah MR, Hasselblad V, Stevenson LW, Binanay C, O'Connor CM, Sopko G, Califf RM (2005) Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. JAMA 294:1664-1670
    • (2005) JAMA , vol.294 , pp. 1664-1670
    • Shah, M.R.1    Hasselblad, V.2    Stevenson, L.W.3    Binanay, C.4    O'Connor, C.M.5    Sopko, G.6    Califf, R.M.7
  • 16
    • 34547153816 scopus 로고    scopus 로고
    • Trends in the use of the pulmonary artery catheter in the United States, 1993-2004
    • 17652296 10.1001/jama.298.4.423 1:CAS:528:DC%2BD2sXot1eks7c%3D
    • Wiener RS, Welch HG (2007) Trends in the use of the pulmonary artery catheter in the United States, 1993-2004. JAMA 298:423-429
    • (2007) JAMA , vol.298 , pp. 423-429
    • Wiener, R.S.1    Welch, H.G.2
  • 17
    • 0031471719 scopus 로고    scopus 로고
    • Clinicians' abilities to estimate cardiac index in ventilated children and infants
    • 9496187 10.1136/adc.77.6.516 1:STN:280:DyaK1c7lslaksA%3D%3D
    • Tibby SM, Hatherill M, Marsh MJ, Murdoch IA (1997) Clinicians' abilities to estimate cardiac index in ventilated children and infants. Arch Dis Child 77:516-518
    • (1997) Arch Dis Child , vol.77 , pp. 516-518
    • Tibby, S.M.1    Hatherill, M.2    Marsh, M.J.3    Murdoch, I.A.4
  • 18
    • 0021275040 scopus 로고
    • Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patients
    • 6734221 10.1097/00003246-198407000-00001 1:STN:280:DyaL2c3jsV2lsg%3D%3D
    • Eisenberg PR, Jaffe AS, Schuster DP (1984) Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patients. Crit Care Med 12:549-553
    • (1984) Crit Care Med , vol.12 , pp. 549-553
    • Eisenberg, P.R.1    Jaffe, A.S.2    Schuster, D.P.3
  • 19
    • 78649326604 scopus 로고    scopus 로고
    • Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods
    • 20689918 10.1007/s00134-010-2003-5
    • Galstyan G, Bychinin M, Alexanyan M, Gorodetsky V (2010) Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods. Intensive Care Med 36:2140-2144
    • (2010) Intensive Care Med , vol.36 , pp. 2140-2144
    • Galstyan, G.1    Bychinin, M.2    Alexanyan, M.3    Gorodetsky, V.4
  • 20
    • 0344406137 scopus 로고    scopus 로고
    • Measured versus estimated oxygen consumption in ventilated patients with congenital heart disease: The validity of predictive equations
    • 12682498 10.1097/01.CCM.0000060010.81321.45
    • Li J, Bush A, Schulze-Neick I, Penny DJ, Redington AN, Shekerdemian LS (2003) Measured versus estimated oxygen consumption in ventilated patients with congenital heart disease: the validity of predictive equations. Crit Care Med 31:1235-1240
    • (2003) Crit Care Med , vol.31 , pp. 1235-1240
    • Li, J.1    Bush, A.2    Schulze-Neick, I.3    Penny, D.J.4    Redington, A.N.5    Shekerdemian, L.S.6
  • 22
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • 12578081 10.1023/A:1009982611386 1:STN:280:DC%2BD3s%2FmslCruw%3D%3D
    • Critchley LA, Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15:85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 23
    • 0023820479 scopus 로고
    • Intrapulmonary oxygen consumption in experimental pneumococcal pneumonia
    • 3136127 1:STN:280:DyaL1c3pvVGjtw%3D%3D
    • Light RB (1988) Intrapulmonary oxygen consumption in experimental pneumococcal pneumonia. J Appl Physiol 64:2490-2495
    • (1988) J Appl Physiol , vol.64 , pp. 2490-2495
    • Light, R.B.1
  • 24
    • 0029846058 scopus 로고    scopus 로고
    • Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients
    • 8891961 10.1016/S0883-9441(96)90006-4 1:STN:280:DyaK2s%2FkslSnsg%3D%3D
    • Axler O, Tousignant C, Thompson CR, Dall'ava-Santucci J, Phang PT, Russell JA, Walley KR (1996) Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients. J Crit Care 11:109-116
    • (1996) J Crit Care , vol.11 , pp. 109-116
    • Axler, O.1    Tousignant, C.2    Thompson, C.R.3    Dall'Ava-Santucci, J.4    Phang, P.T.5    Russell, J.A.6    Walley, K.R.7
  • 25
    • 0031060466 scopus 로고    scopus 로고
    • Measuring cardiac output in critically Ill patients: Disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods
    • 8960620 10.1159/000177304 1:STN:280:DyaK2s7hvF2nuw%3D%3D
    • Sherman MS, Kosinski R, Paz HL, Campbell D (1997) Measuring cardiac output in critically Ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods. Cardiology 88:19-25
    • (1997) Cardiology , vol.88 , pp. 19-25
    • Sherman, M.S.1    Kosinski, R.2    Paz, H.L.3    Campbell, D.4
  • 26
    • 0037386425 scopus 로고    scopus 로고
    • Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients
    • 12720564 10.1186/cc1848
    • Gonzalez J, Delafosse C, Fartoukh M, Capderou A, Straus C, Zelter M, Derenne JP, Similowski T (2003) Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients. Crit Care 7:171-178
    • (2003) Crit Care , vol.7 , pp. 171-178
    • Gonzalez, J.1    Delafosse, C.2    Fartoukh, M.3    Capderou, A.4    Straus, C.5    Zelter, M.6    Derenne, J.P.7    Similowski, T.8
  • 27
    • 0014555452 scopus 로고
    • Critical assessment of use of central venous oxygen saturation as a mirror of mixed venous oxygen in severely ill cardiac patients
    • 5796787 10.1161/01.CIR.40.2.165 1:STN:280:DyaF1M3ktFCltQ%3D%3D
    • Scheinman MM, Brown MA, Rapaport E (1969) Critical assessment of use of central venous oxygen saturation as a mirror of mixed venous oxygen in severely ill cardiac patients. Circulation 40:165-172
    • (1969) Circulation , vol.40 , pp. 165-172
    • Scheinman, M.M.1    Brown, M.A.2    Rapaport, E.3
  • 28
    • 70450223542 scopus 로고    scopus 로고
    • Comparison of a new cardiac output ultrasound dilution method with thermodilution technique in adult patients under general anesthesia
    • 19464193 10.1053/j.jvca.2009.03.007
    • Tsutsui M, Matsuoka N, Ikeda T, Sanjo Y, Kazama T (2009) Comparison of a new cardiac output ultrasound dilution method with thermodilution technique in adult patients under general anesthesia. J Cardiothorac Vasc Anesth 23:835-840
    • (2009) J Cardiothorac Vasc Anesth , vol.23 , pp. 835-840
    • Tsutsui, M.1    Matsuoka, N.2    Ikeda, T.3    Sanjo, Y.4    Kazama, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.