메뉴 건너뛰기




Volumn 47, Issue 2, 2013, Pages 154-160

Uterine perforation - 5-year experience in 3-d image guided gynaecological brachytherapy at institute of oncology ljubljana

Author keywords

3d imaging; Brachytherapy; Ultrasound guidance; Uterine perforation

Indexed keywords

CISPLATIN;

EID: 84885005926     PISSN: 13182099     EISSN: 15813207     Source Type: Journal    
DOI: 10.2478/raon-2013-0030     Document Type: Article
Times cited : (32)

References (38)
  • 1
    • 0020622768 scopus 로고
    • Uterine perforation during intracavitary application. Prognostic significance in carcinoma of the cervix
    • Kim RY, Levy DS, Brascho DJ, Hatch KD. Uterine perforation during intracavitary application. Prognostic significance in carcinoma of the cervix. Radiology 1983; 147; 249-51. (Pubitemid 13112356)
    • (1983) Radiology , vol.147 , Issue.1 , pp. 249-251
    • Kim, R.Y.1    Levy, D.S.2    Brascho, D.J.3    Hatch, K.D.4
  • 3
    • 0034653303 scopus 로고    scopus 로고
    • Perioperative and postoperative complications of intracavitary radiation for FIGO stage I-III carcinoma of the cervix
    • DOI 10.1016/S0360-3016(99)00545-3, PII S0360301699005453
    • Jhingran A, Eifel PJ. Perioperative and postoperative complications of intracavitary radiation for FIGO stage l-lll carcinoma of the cervix. Int J Radiat Oncol Biol Phys 2000; 46:1177-83. (Pubitemid 30139428)
    • (2000) International Journal of Radiation Oncology Biology Physics , vol.46 , Issue.5 , pp. 1177-1183
    • Jhingran, A.1    Eifel, P.J.2
  • 5
    • 0022636484 scopus 로고
    • Uterine perforation at the time of brachytherapy for the carcinoma of the uterine cervix
    • DOI 10.1016/0090-8258(86)90225-8
    • Matsuyama T, Tsukamoto N, Matsukuma K, Kamura T, Jingu K. Uterine perforation at the time of brachytherapy for the carcinoma of the uterine cervix. Gynecol Oncol 1986; 23:205-11. (Pubitemid 16155036)
    • (1986) Gynecologic Oncology , vol.23 , Issue.2 , pp. 205-211
    • Matsuyama, T.1    Tsukamoto, N.2    Matsukuma, K.3
  • 6
    • 34447298127 scopus 로고    scopus 로고
    • Prospective comparison of clinical and computed tomography assessment in detecting uterine perforation with intracavitary brachytherapy for carcinoma of the cervix
    • DOI 10.1111/j.1525-1438.2007.00888.x
    • Barnes EA, Thomas G, Ackerman I, Barbera L, Letourneau, Lam K, et al. Prospective comparison of clinical and computed tomography assessment in detecting uterine perforation with intracavitary brachytherapy for carcinoma of the cervix. Int J Gynecol Cancer 2007; 17:821-6. (Pubitemid 47063335)
    • (2007) International Journal of Gynecological Cancer , vol.17 , Issue.4 , pp. 821-826
    • Barnes, E.A.1    Thomas, G.2    Ackerman, I.3    Barbera, L.4    Letourneau, D.5    Lam, K.6    Makhani, N.7    Sankreacha, R.8
  • 7
    • 0038162247 scopus 로고    scopus 로고
    • Uterine perforation at the time of brachytherapy for carcinoma of the cervix
    • DOI 10.1016/S0090-8258(03)00230-0
    • Irvin W, Rice L, Taylor P, Anderson W, Schneider B. Uterine perforation at the time of brachytherapy for carcinoma of the cervix. Gynecol Oncol 2003; 90:113-22. (Pubitemid 37338085)
    • (2003) Gynecologic Oncology , vol.90 , Issue.1 , pp. 113-122
    • Irvin, W.1    Rice, L.2    Taylor, P.3    Andersen, W.4    Schneider, B.5
  • 8
    • 0026075999 scopus 로고
    • Uterine perforation by an intracavitary tandem: Ct demonstration
    • Milman RM, Goodman P. Uterine perforation by an intracavitary tandem: CT demonstration. Clin Imaging 1991; 15:223-6.
    • (1991) Clin Imaging , vol.15 , pp. 223-226
    • Milman, R.M.1    Goodman, P.2
  • 9
    • 0019457614 scopus 로고
    • Endometrial adenosarcoma with pelvic involvement following uterine perforation
    • Mills SE, Sugg NK, Mahnesmith RC Endometrial carcinoma with pelvic involvement following uterine perforation. Diagn Gynecol Obstet 1981; 3: 149-54. (Pubitemid 11085326)
    • (1981) Diagnostic Gynecology and Obstetrics , vol.3 , Issue.2 , pp. 149-154
    • Mills, S.E.1    Sugg, N.K.2    Mahnesmith, R.C.3
  • 10
    • 0028340113 scopus 로고
    • Technically accurate intracavitary insertions improve pelvic control and survival among patients with locally advanced carcinoma of the uterine cervix
    • DOI 10.1006/gyno.1994.1137
    • Corn BW, Hanlon AL, Pajak TF, Owen J, Hanks GE. Technically accurate intracavitary insertions improve pelvic control among patients with locally advanced carcinoma of the uterine cervix. Gynecol Oncol 1994, 53:294-300. (Pubitemid 24187856)
    • (1994) Gynecologic Oncology , vol.53 , Issue.3 , pp. 294-300
    • Corn, B.W.1    Hanlon, A.L.2    Pajak, T.F.3    Owen, J.4    Hanks, G.E.5
  • 11
    • 84885935221 scopus 로고    scopus 로고
    • Mri-based brachytherapy for cervical cancer
    • Petric P, Hudej R, Marolt-Music M. MRI-based brachytherapy for cervical cancer. Onkologija 2008; 12:46-51.
    • (2008) Onkologija , vol.12 , pp. 46-51
    • Petric, P.1    Hudej, R.2    Marolt-Music, M.3
  • 12
    • 84885931062 scopus 로고    scopus 로고
    • Moving from 2d to 3d brachytherapy in gynecological tumors
    • Petric P. Moving from 2D to 3D brachytherapy in gynecological tumors. J Contemp Brachyther 2011; 3:161-2.
    • (2011) J Contemp Brachyther , vol.3 , pp. 161-162
    • Petric, P.1
  • 13
    • 84885911082 scopus 로고    scopus 로고
    • Mri assisted treatment planning improves the dvh parameters in cervix cancer brachytherapy
    • Petric P, Hudej R, Segedin B, Zobec Logar HB. MRI assisted treatment planning improves the DVH parameters in cervix cancer brachytherapy. Radiother Oncol 2011; 99:264-5.
    • (2011) Radiother Oncol , vol.99 , pp. 264-265
    • Petric, P.1    Hudej, R.2    Segedin, B.3    Zobec, L.H.B.4
  • 14
    • 84867310056 scopus 로고    scopus 로고
    • Comparison of 3d mri with high sampling efficiency and 2d multiplanar mri for contouring in cervix cancer brachytherapy
    • Petric P, Hudej R, Rogelj P, Bias M, Segedin B, Zobec logar HB, et al. Comparison of 3D MRI with high sampling efficiency and 2D multiplanar MRI for contouring in cervix cancer brachytherapy. Radiol Oncol 2012; 46-242-51.
    • (2012) Radiol Oncol , vol.46 , pp. 242-251
    • Petric, P.1    Hudej, R.2    Rogelj, P.3    Bias, M.4    Segedin, B.5    Zobec, L.H.B.6
  • 15
    • 51049099674 scopus 로고    scopus 로고
    • Inter- And in- traobserver variation in hr-ctv contouring: Intercomparison of transverse and paratransverse image orientation in 3d-mri assisted cervix cancer brachytherapy
    • Petric P, Dimopoulos JCA, Kirisits C, Berger D, Hudej R, Potter R. Inter- And in- traobserver variation in HR-CTV contouring: intercomparison of transverse and paratransverse image orientation in 3D-MRI assisted cervix cancer brachytherapy. Radiother Oncol 2008; 89:164-71.
    • (2008) Radiother Oncol , vol.89 , pp. 164-171
    • Petric, P.1    Dimopoulos, J.C.A.2    Kirisits, C.3    Berger, D.4    Hudej, R.5    Potter, R.6
  • 17
    • 31144452943 scopus 로고    scopus 로고
    • Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy - 3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology
    • DOI 10.1016/j.radonc.2005.11.014, PII S0167814005005463
    • Potter R, Haie-Mader C, Van Umbergen E, Barillot I, De Brabandere M, Dimopoulos J, et al. Recommendations from gynaecological (GYN) GEC ESTRO working group (II): concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology. Radiother Oncol 2006; 78:67-77. (Pubitemid 43131038)
    • (2006) Radiotherapy and Oncology , vol.78 , Issue.1 , pp. 67-77
    • Potter, R.1    Haie-Meder, C.2    Van Limbergen, E.3    Barillot, I.4    De Brabandere, M.5    Dimopoulos, J.6    Dumas, I.7    Erickson, B.8    Lang, S.9    Nulens, A.10    Petrow, P.11    Rownd, J.12    Kirisits, C.13
  • 19
    • 14844283334 scopus 로고    scopus 로고
    • Cervix cancer
    • Gerbaulet A, Potter R, Mazeron JJ, Meertens H, Van Umbergen E, editors. Brussels: European Society of Therapeutic Radiology and Oncology
    • Gerbaulet A, Potter R, Haie-Meder C. Cervix cancer. In: Gerbaulet A, Potter R, Mazeron JJ, Meertens H, Van Umbergen E, editors. The GEC ESTRO handbook of brachytherapy. Brussels: European Society of Therapeutic Radiology and Oncology; 2002. p. 301-63.
    • (2002) The GEC ESTRO Handbook of Brachytherapy , pp. 301-363
    • Gerbaulet, A.1    Potter, R.2    Haie-Meder, C.3
  • 20
    • 77549085727 scopus 로고    scopus 로고
    • Mri assisted cervix cancer brachytherapy pre-planning, based on insertion of the applicator in para-cervical anaesthesia: Preliminary results of a prospective study
    • Petric P, Hudej R, Marolt-Music M. MRI assisted cervix cancer brachytherapy pre-planning, based on insertion of the applicator in para-cervical anaesthesia: preliminary results of a prospective study. J Contemp Brachyther 2009; 1:163-9.
    • (2009) J Contemp Brachyther , vol.1 , pp. 163-169
    • Petric, P.1    Hudej, R.2    Marolt-Music, M.3
  • 21
  • 22
    • 84857767364 scopus 로고    scopus 로고
    • Frequency-distribution mapping of hr ctv in cervix cancer: Possibilities and limitations of existent and prototype applicators
    • Petric P, Hudej R, Rogelj P, Lindegaard I, Tanderup K, Kirisits C, et al. Frequency-distribution mapping of HR CTV in cervix cancer: possibilities and limitations of existent and prototype applicators. Radiother Oncol 2010; 96:70.
    • (2010) Radiother Oncol , vol.96 , pp. 70
    • Petric, P.1    Hudej, R.2    Rogelj, P.3    Lindegaard, I.4    Tanderup, K.5    Kirisits, C.6
  • 23
    • 0024264555 scopus 로고
    • CT scanning in intracavitary therapy: Unexpected findings in 'straightforward' insertions
    • DOI 10.1016/0167-8140(88)90220-4
    • Makin WP, Hunter, RD. CT scanning in intracavitary therapy: Unexpected findings in "straightforward" insertions. Radiother Oncol 1988; 13:253-5. (Pubitemid 19009240)
    • (1988) Radiotherapy and Oncology , vol.13 , Issue.4 , pp. 253-255
    • Makin, W.P.1    Hunter, R.D.2
  • 24
    • 46849109296 scopus 로고    scopus 로고
    • Optimization of high-dose-rate cervix brachytherapy applicator placement: The benefits of intraoperative ultrasound guidance
    • DOI 10.1016/j.brachy.2008.03.004, PII S1538472108005576
    • Davidson MTM, Yuen J, D'Souza DP, Radwan JS, Hammond JA, Batchelar DL Optimization of high-dose-rate cervix brachytherapy applicator placement: The benefits of intraoperative ultrasound guidance. Brachytherapy 2008; 7:248-53. (Pubitemid 351957934)
    • (2008) Brachytherapy , vol.7 , Issue.3 , pp. 248-253
    • Davidson, M.T.M.1    Yuen, J.2    D'Souza, D.P.3    Radwan, J.S.4    Hammond, J.A.5    Batchelar, D.L.6
  • 25
    • 0014868924 scopus 로고
    • Use of pelvic pneumography in planning radiotherapy of endometrial carcinoma
    • Brascho DJ. Use of pelvic pneumography in planning radiotherapy of endometrial carcinoma. Radiology 1970; 97:113-20.
    • (1970) Radiology , vol.97 , pp. 113-120
    • Brascho, D.J.1
  • 26
    • 0016539459 scopus 로고
    • Tandem hysterography during intrauterine radium application
    • Scott WP. Tandem hysterography during intrauterine radium application. Am J Roentgenol Radium Ther Nucl Med 1975; 124:636-7.
    • (1975) Am J Roentgenol Radium Ther Nucl Med , vol.124 , pp. 636-637
    • Scott, W.P.1
  • 28
    • 77955714423 scopus 로고    scopus 로고
    • Mri-based low dose-rate brachytherapy experience in locally advanced cervical cancer patients initially treated by concomitant chemoradiotherapy
    • Haie-Meder C, Chargari C, Rey A, Dumas I, Morice P, Magnc N. MRI-based low dose-rate brachytherapy experience in locally advanced cervical cancer patients initially treated by concomitant chemoradiotherapy. Radiother Oncol 2010; 96:161-5.
    • (2010) Radiother Oncol , vol.96 , pp. 161-165
    • Haie-Meder, C.1    Chargari, C.2    Rey, A.3    Dumas, I.4    Morice, P.5    Magnc, N.6
  • 30
    • 44449163974 scopus 로고    scopus 로고
    • Mri-guided 3d optimization significantly pmproves dvh parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer
    • Lindegaard JC, Tanderup K, Nielsen SK, Haack S, Gelineck J. MRI-guided 3D optimization significantly pmproves DVH Parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer. Int J Radiat Oncol Biol Phys 2008; 71:756-64.
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 756-764
    • Lindegaard, J.C.1    Tanderup, K.2    Nielsen, S.K.3    Haack, S.4    Gelineck, J.5
  • 31
    • 80051789536 scopus 로고    scopus 로고
    • Clinical outcome of protocol based image (mri) guided adaptive brachytherapy combined with 3d conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer
    • Potter R, Georg P, Dimopoulos J, Grimm M, Berger D, Nesvacil N, et al. Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer. Radiother Oncol 2011; 100:116-23.
    • (2011) Radiother Oncol , vol.100 , pp. 116-123
    • Potter, R.1    Georg, P.2    Dimopoulos, J.3    Grimm, M.4    Berger, D.5    Nesvacil, N.6
  • 32
    • 70350499498 scopus 로고    scopus 로고
    • Mri-guided treatment-planning optimisation in intracavitary or combined intracavitary/interstitiai pdr brachytherapy using tandem ovoid applicators in locally advanced cervical cancer
    • Jurgenliemk-Schulz IM, Tersteeg RJ, Roesink JM, Bijmolt S, Nomden CN, Moerland MA, et al. MRI-guided treatment-planning optimisation in intracavitary or combined intracavitary/interstitiai PDR brachytherapy using tandem ovoid applicators in locally advanced cervical cancer. Radiother Oncol 2009; 93:322-30.
    • (2009) Radiother Oncol , vol.93 , pp. 322-330
    • Jurgenliemk-Schulz, I.M.1    Tersteeg, R.J.2    Roesink, J.M.3    Bijmolt, S.4    Nomden, C.N.5    Moerland, M.A.6
  • 33
    • 0021245685 scopus 로고
    • Ultrasound used for assessing the in situ position of intrauterine tandems
    • Granai CO, Allee P, Doherty F, Madoc-Jones H, Curry SL Ultrasound used for assessing the in situ position of intrauterine tandems. Gynecol Oncol 1984; 18:334-8. (Pubitemid 14095033)
    • (1984) Gynecologic Oncology , vol.18 , Issue.3 , pp. 334-338
    • Granai, C.O.1    Allee, P.2    Doherty, F.3
  • 34
    • 0022644995 scopus 로고
    • Intraoperative real-time ultrasonography during intrauterine tandem placement
    • Granai CO, Allee P, Doherty F, Ball HG, Madoc-Jones H, Curry SL Intraperative real-time ultrasonography during intrauterine tandem placement. Obstet Gynecol 1986; 67:112-4. (Pubitemid 16174311)
    • (1986) Obstetrics and Gynecology , vol.67 , Issue.1 , pp. 112-114
    • Granai, C.O.1    Allee, P.2    Doherty, F.3
  • 35
    • 0025126272 scopus 로고
    • The usefulness of ultrasonography in intracavitary radiotherapy using selectron applicators
    • Wong F, Bhimji S. The usefulness of ultrasonography in intracavitary radiotherapy using selectron applicators. Int J Radiat Oncol Biol Phys 1990; 19:477-82. (Pubitemid 20299044)
    • (1990) International Journal of Radiation Oncology Biology Physics , vol.19 , Issue.2 , pp. 477-482
    • Wong, F.1    Bhimji, S.2
  • 37
    • 0025289355 scopus 로고
    • Intraoperative guidance for intrauterine procedures with transrectal sonography
    • Fleischer AC, Burnett LS, Murray MJ, Jones HW. Intraoperative guidance for intrauterine procedures with transrectal sonography. Radiology 1990; 176:576-7. (Pubitemid 20225160)
    • (1990) Radiology , vol.176 , Issue.2 , pp. 576-577
    • Fleischer, A.C.1    Burnett, L.S.2    Murray, M.J.3    Jones III, H.W.4
  • 38
    • 77953448020 scopus 로고    scopus 로고
    • Use of transrectal ultrasound for high dose rate interstitial brachytherapy for patients of carcinoma of uterine cervix
    • Sharma DN, Rath GK, Thulkar S, Kumar S, Subramani V, Julka PK. Use of transrectal ultrasound for high dose rate interstitial brachytherapy for patients of carcinoma of uterine cervix. J Gynecol Oncol 2010; 21:12-7.
    • (2010) J Gynecol Oncol , vol.21 , pp. 12-17
    • Sharma, D.N.1    Rath, G.K.2    Thulkar, S.3    Kumar, S.4    Subramani, V.5    Julka, P.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.