메뉴 건너뛰기




Volumn 7, Issue 3, 2008, Pages 248-253

Optimization of high-dose-rate cervix brachytherapy applicator placement: The benefits of intraoperative ultrasound guidance

Author keywords

Cervix cancer; High dose rate brachytherapy; Image guidance; Intracavitary; Ultrasound

Indexed keywords

ARTICLE; BRACHYTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; EXTERNAL BEAM RADIOTHERAPY; FEMALE; HUMAN; PEROPERATIVE ECHOGRAPHY; PRIORITY JOURNAL; RADIATION DOSE; UTERINE CERVIX CANCER; UTERINE CERVIX DILATATION;

EID: 46849109296     PISSN: 15384721     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.brachy.2008.03.004     Document Type: Article
Times cited : (67)

References (25)
  • 1
    • 0036150168 scopus 로고    scopus 로고
    • Gynecologic brachytherapy I: Proper incorporation of brachytherapy into the current multimodality management of carcinoma of the cervix
    • Nori D., Dasari N., and Allbright R.M. Gynecologic brachytherapy I: Proper incorporation of brachytherapy into the current multimodality management of carcinoma of the cervix. Semin Radiat Oncol 12 (2002) 40-52
    • (2002) Semin Radiat Oncol , vol.12 , pp. 40-52
    • Nori, D.1    Dasari, N.2    Allbright, R.M.3
  • 2
    • 0033981054 scopus 로고    scopus 로고
    • Optimizing radiation parameters for cervical cancer
    • Lanciano R. Optimizing radiation parameters for cervical cancer. Semin Radiat Oncol 10 (2000) 36-43
    • (2000) Semin Radiat Oncol , vol.10 , pp. 36-43
    • Lanciano, R.1
  • 3
    • 0030955349 scopus 로고    scopus 로고
    • Consensus statement: National Institutes of Health consensus development conference statement on cervical cancer
    • National Institutes of Health. Consensus statement: National Institutes of Health consensus development conference statement on cervical cancer. Gynecol Oncol 66 (1997) 351-361
    • (1997) Gynecol Oncol , vol.66 , pp. 351-361
    • National Institutes of Health1
  • 4
    • 0029134796 scopus 로고
    • Carcinoma of the cervix: Pattern of Care Studies: Review of 1978, 1983, and 1988-1989 surveys
    • Montana G.S., Hanlon A.L., Brickner T.L., et al. Carcinoma of the cervix: Pattern of Care Studies: Review of 1978, 1983, and 1988-1989 surveys. Int J Radiat Oncol Biol Phys 32 (1995) 1481-1486
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 1481-1486
    • Montana, G.S.1    Hanlon, A.L.2    Brickner, T.L.3
  • 5
    • 0025644696 scopus 로고
    • The Patterns of Care Outcome Study for cancer of the uterine cervix. Results of the Second National Practice Survey
    • Coia L., Won M., Lanciano R., et al. The Patterns of Care Outcome Study for cancer of the uterine cervix. Results of the Second National Practice Survey. Cancer 66 (1990) 2451-2456
    • (1990) Cancer , vol.66 , pp. 2451-2456
    • Coia, L.1    Won, M.2    Lanciano, R.3
  • 6
    • 20044380933 scopus 로고    scopus 로고
    • Brachytherapy management of the retroverted uterus using ultrasound-guided implant applicator placement
    • Mayr N.A., Montebello J.F., Sorosky J.I., et al. Brachytherapy management of the retroverted uterus using ultrasound-guided implant applicator placement. Brachytherapy 4 (2005) 24-29
    • (2005) Brachytherapy , vol.4 , pp. 24-29
    • Mayr, N.A.1    Montebello, J.F.2    Sorosky, J.I.3
  • 7
    • 0038162247 scopus 로고    scopus 로고
    • Uterine perforation at the time of brachytherapy for carcinoma of the cervix
    • Irvin W., Rice L., Taylor P., et al. Uterine perforation at the time of brachytherapy for carcinoma of the cervix. Gynecol Oncol 90 (2003) 113-122
    • (2003) Gynecol Oncol , vol.90 , pp. 113-122
    • Irvin, W.1    Rice, L.2    Taylor, P.3
  • 8
    • 0028340113 scopus 로고
    • Technically accurate intracavitary insertions improve pelvic control and survival among patients with locally advanced carcinoma of the uterine cervix
    • Corn B.W., Hanlon A.L., Pajak T.F., et al. Technically accurate intracavitary insertions improve pelvic control and survival among patients with locally advanced carcinoma of the uterine cervix. Gynecol Oncol 53 (1994) 294-300
    • (1994) Gynecol Oncol , vol.53 , pp. 294-300
    • Corn, B.W.1    Hanlon, A.L.2    Pajak, T.F.3
  • 9
    • 0035915779 scopus 로고    scopus 로고
    • Comparison of radiography- and computed tomography-based treatment planning in cervix cancer brachytherapy with specific attention to some quality assurance aspects
    • Fellner C., Pötter R., Knocke T.H., et al. Comparison of radiography- and computed tomography-based treatment planning in cervix cancer brachytherapy with specific attention to some quality assurance aspects. Radiother Oncol 58 (2001) 53-62
    • (2001) Radiother Oncol , vol.58 , pp. 53-62
    • Fellner, C.1    Pötter, R.2    Knocke, T.H.3
  • 10
    • 20344407033 scopus 로고    scopus 로고
    • Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer
    • Kirisits C., Pötter R., Lang S., et al. Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer. Int J Radiat Oncol Biol Phys 62 (2005) 901-911
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 901-911
    • Kirisits, C.1    Pötter, R.2    Lang, S.3
  • 11
    • 34447298127 scopus 로고    scopus 로고
    • Prospective comparison of clinical and computed tomography assessment in detecting uterine perforation with intracavitary brachytherapy for carcinoma of the cervix
    • Barnes E.A., Thomas G., Ackerman I., et al. Prospective comparison of clinical and computed tomography assessment in detecting uterine perforation with intracavitary brachytherapy for carcinoma of the cervix. Int J Gynecol Cancer 17 (2007) 821-826
    • (2007) Int J Gynecol Cancer , vol.17 , pp. 821-826
    • Barnes, E.A.1    Thomas, G.2    Ackerman, I.3
  • 12
    • 0034564179 scopus 로고    scopus 로고
    • Quantification of intracavitary brachytherapy parameters and correlation with outcome in patients with carcinoma of the cervix
    • Katz A., and Eifel P.J. Quantification of intracavitary brachytherapy parameters and correlation with outcome in patients with carcinoma of the cervix. Int J Radiat Oncol Biol Phys 48 (2000) 1417-1425
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1417-1425
    • Katz, A.1    Eifel, P.J.2
  • 13
    • 0023335875 scopus 로고
    • Sonographic positioning of endouterine applicator
    • Tanaka S., Hishikawa Y., Kamikonya N., et al. Sonographic positioning of endouterine applicator. Radiat Med 5 (1987) 92-93
    • (1987) Radiat Med , vol.5 , pp. 92-93
    • Tanaka, S.1    Hishikawa, Y.2    Kamikonya, N.3
  • 14
    • 0025128696 scopus 로고
    • Ultrasound for diagnosing and preventing malplacement of intrauterine tandems
    • Granai C.O., Doherty F., Allee P., et al. Ultrasound for diagnosing and preventing malplacement of intrauterine tandems. Obstet Gynecol 75 (1990) 110-113
    • (1990) Obstet Gynecol , vol.75 , pp. 110-113
    • Granai, C.O.1    Doherty, F.2    Allee, P.3
  • 15
    • 0021245685 scopus 로고
    • Ultrasound used for assessing the in situ position of intrauterine tandems
    • Granai C.O., Allee P., Doherty F., et al. Ultrasound used for assessing the in situ position of intrauterine tandems. Gynecol Oncol 18 (1984) 334-338
    • (1984) Gynecol Oncol , vol.18 , pp. 334-338
    • Granai, C.O.1    Allee, P.2    Doherty, F.3
  • 16
    • 0022644995 scopus 로고
    • Intraoperative real-time ultrasonography during intrauterine tandem placement
    • Granai C.O., Allee P., Doherty F., et al. Intraoperative real-time ultrasonography during intrauterine tandem placement. Obstet Gynecol 67 (1986) 112-114
    • (1986) Obstet Gynecol , vol.67 , pp. 112-114
    • Granai, C.O.1    Allee, P.2    Doherty, F.3
  • 17
    • 0025126272 scopus 로고
    • The usefulness of ultrasonography in intracavitary radiotherapy using selectron applicators
    • Wong F., and Bhimji S. The usefulness of ultrasonography in intracavitary radiotherapy using selectron applicators. Int J Radiat Oncol Biol Phys 19 (1990) 477-482
    • (1990) Int J Radiat Oncol Biol Phys , vol.19 , pp. 477-482
    • Wong, F.1    Bhimji, S.2
  • 18
    • 0031080894 scopus 로고    scopus 로고
    • Intra- and perioperative complications associated with tandem and colpostat application for cervix cancer
    • Corn B.W., Shaktman B.D., Lanciano R.M., et al. Intra- and perioperative complications associated with tandem and colpostat application for cervix cancer. Gynecol Oncol 64 (1997) 224-229
    • (1997) Gynecol Oncol , vol.64 , pp. 224-229
    • Corn, B.W.1    Shaktman, B.D.2    Lanciano, R.M.3
  • 19
    • 0029099034 scopus 로고
    • Carcinoma of the uterine cervix. I. Impact of prolongation of overall treatment time and timing of brachytherapy on outcome of radiation therapy
    • Perez C.A., Grigsby P.W., Castro-Vita H., et al. Carcinoma of the uterine cervix. I. Impact of prolongation of overall treatment time and timing of brachytherapy on outcome of radiation therapy. Int J Radiat Oncol Biol Phys 32 (1995) 1275-1288
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 1275-1288
    • Perez, C.A.1    Grigsby, P.W.2    Castro-Vita, H.3
  • 20
    • 0027994035 scopus 로고
    • Ultrasound guidance for placement of difficult intracavitary implants
    • Rotmensch J., Waggoner S.E., and Quiet C. Ultrasound guidance for placement of difficult intracavitary implants. Gynecol Oncol 54 (1994) 159-162
    • (1994) Gynecol Oncol , vol.54 , pp. 159-162
    • Rotmensch, J.1    Waggoner, S.E.2    Quiet, C.3
  • 21
    • 0035290057 scopus 로고    scopus 로고
    • Invasive procedures in the female pelvis: Value of transabdominal, endovaginal, and endorectal US guidance
    • Scanlan K.A., Propeck P.A., and Lee Jr. F.T. Invasive procedures in the female pelvis: Value of transabdominal, endovaginal, and endorectal US guidance. Radiographics 21 (2001) 491-506
    • (2001) Radiographics , vol.21 , pp. 491-506
    • Scanlan, K.A.1    Propeck, P.A.2    Lee Jr., F.T.3
  • 22
    • 0024264555 scopus 로고
    • CT scanning in intracavitary therapy: Unexpected findings in "straightforward" insertions
    • Makin W.P., and Hunter R.D. CT scanning in intracavitary therapy: Unexpected findings in "straightforward" insertions. Radiother Oncol 13 (1988) 253-255
    • (1988) Radiother Oncol , vol.13 , pp. 253-255
    • Makin, W.P.1    Hunter, R.D.2
  • 23
    • 0022636484 scopus 로고
    • Uterine perforation at the time of brachytherapy for carcinoma of the uterine cervix
    • Matsuyama T., Tsukamoto N., Matsukama K., et al. Uterine perforation at the time of brachytherapy for carcinoma of the uterine cervix. Gynecol Oncol 23 (1986) 205-211
    • (1986) Gynecol Oncol , vol.23 , pp. 205-211
    • Matsuyama, T.1    Tsukamoto, N.2    Matsukama, K.3
  • 24
    • 0020622768 scopus 로고
    • Uterine perforation during intracavitary application. Prognostic significance in carcinoma of the cervix
    • Kim R.Y., Levy D.S., Brascho D.J., et al. Uterine perforation during intracavitary application. Prognostic significance in carcinoma of the cervix. Radiology 147 (1983) 249-251
    • (1983) Radiology , vol.147 , pp. 249-251
    • Kim, R.Y.1    Levy, D.S.2    Brascho, D.J.3
  • 25
    • 0026075999 scopus 로고
    • Uterine perforation by an intracavitary tandem: CT demonstration
    • Milman R.M., and Goodman P. Uterine perforation by an intracavitary tandem: CT demonstration. Clin Imaging 15 (1991) 223-226
    • (1991) Clin Imaging , vol.15 , pp. 223-226
    • Milman, R.M.1    Goodman, P.2