-
1
-
-
27944449749
-
In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
-
Boutroy S., Bouxsein M.L., Munoz F., Delmas P. In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. Journal of Clinical Endocrinology and Metabolism 2005, 90:6508-6515.
-
(2005)
Journal of Clinical Endocrinology and Metabolism
, vol.90
, pp. 6508-6515
-
-
Boutroy, S.1
Bouxsein, M.L.2
Munoz, F.3
Delmas, P.4
-
2
-
-
0033213780
-
Femoral strength is better predicted by finite element models than QCT and DXA
-
Cody D.D. Femoral strength is better predicted by finite element models than QCT and DXA. Journal of Biomechanics 1999, 32:1013-1020.
-
(1999)
Journal of Biomechanics
, vol.32
, pp. 1013-1020
-
-
Cody, D.D.1
-
3
-
-
79959565823
-
A calibration methodology of QCT BMD for human vertebral body with registered micro-CT images
-
Dall'Ara E., Varga P., Pahr D., Zysset P. A calibration methodology of QCT BMD for human vertebral body with registered micro-CT images. Medical Physics 2011, 38:2602-2608.
-
(2011)
Medical Physics
, vol.38
, pp. 2602-2608
-
-
Dall'Ara, E.1
Varga, P.2
Pahr, D.3
Zysset, P.4
-
4
-
-
0021388724
-
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
-
Harrigan T.P., Mann R.W. Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor. Journal of Materials Science 1984, 19:761-767.
-
(1984)
Journal of Materials Science
, vol.19
, pp. 761-767
-
-
Harrigan, T.P.1
Mann, R.W.2
-
5
-
-
78651477793
-
Structural parameters of normal and osteoporotic human trabecular bone are affected differently by microCT image resolution
-
Isaksson H., Töyräs J., Hakulinen M., Aula A.S., Tamminen I., Julkunen P., Kröger H., Jurvelin J.S. Structural parameters of normal and osteoporotic human trabecular bone are affected differently by microCT image resolution. Osteoporosis International 2011, 22:167-177.
-
(2011)
Osteoporosis International
, vol.22
, pp. 167-177
-
-
Isaksson, H.1
Töyräs, J.2
Hakulinen, M.3
Aula, A.S.4
Tamminen, I.5
Julkunen, P.6
Kröger, H.7
Jurvelin, J.S.8
-
6
-
-
0031172266
-
Adaptive bone remodeling incorporating simultaneous density and anisotropy considerations
-
Jacobs C.R., Simo J.C., Beaupre G.S., Carter D.R. Adaptive bone remodeling incorporating simultaneous density and anisotropy considerations. Journal of Biomechanics 1997, 30:603-613.
-
(1997)
Journal of Biomechanics
, vol.30
, pp. 603-613
-
-
Jacobs, C.R.1
Simo, J.C.2
Beaupre, G.S.3
Carter, D.R.4
-
7
-
-
0034995656
-
Improved prediction of proximal femoral fracture load using nonlinear finite element models
-
Keyak J.H. Improved prediction of proximal femoral fracture load using nonlinear finite element models. Medical Engineering and Physics 2001, 23:165-173.
-
(2001)
Medical Engineering and Physics
, vol.23
, pp. 165-173
-
-
Keyak, J.H.1
-
8
-
-
0035689961
-
Prediction of fracture location in the proximal femur using finite element models
-
Keyak J.H. Prediction of fracture location in the proximal femur using finite element models. Medical Engineering and Physics 2001, 23:657-664.
-
(2001)
Medical Engineering and Physics
, vol.23
, pp. 657-664
-
-
Keyak, J.H.1
-
9
-
-
0344157373
-
Prediction of femoral fracture load using automated finite element modeling
-
Keyak J.H., Rossi S.A., Jones K.A., Skinner H.B. Prediction of femoral fracture load using automated finite element modeling. Journal of Biomechanics 1998, 31:125-133.
-
(1998)
Journal of Biomechanics
, vol.31
, pp. 125-133
-
-
Keyak, J.H.1
Rossi, S.A.2
Jones, K.A.3
Skinner, H.B.4
-
11
-
-
77956842169
-
Accuracy of high-resolution in vivo micro magnetic resonance imaging for measurements of microstructural and mechanical properties of human distal tibial bone
-
Liu X.S., Zhang X.H., Rajapakse C.S., Wald M.J., Magland J., Sekhon K.K., Adam M.F., Sajda P., Wehrli F.W., Guo X.E. Accuracy of high-resolution in vivo micro magnetic resonance imaging for measurements of microstructural and mechanical properties of human distal tibial bone. Journal of Bone and Mineral Research 2010, 25:2039-2050.
-
(2010)
Journal of Bone and Mineral Research
, vol.25
, pp. 2039-2050
-
-
Liu, X.S.1
Zhang, X.H.2
Rajapakse, C.S.3
Wald, M.J.4
Magland, J.5
Sekhon, K.K.6
Adam, M.F.7
Sajda, P.8
Wehrli, F.W.9
Guo, X.E.10
-
12
-
-
84872575276
-
Quantitative characterization of trabecular bone micro-architecture using tensor scale and multi-detector CT imaging
-
Springer, Berlin
-
Liu Y. Quantitative characterization of trabecular bone micro-architecture using tensor scale and multi-detector CT imaging. Medical Image Computing and Computer-Assisted Intervention-MICCAI 2012 2012, 124-131. Springer, Berlin.
-
(2012)
Medical Image Computing and Computer-Assisted Intervention-MICCAI 2012
, pp. 124-131
-
-
Liu, Y.1
-
13
-
-
0025790268
-
Fracture prediction for the proximal femur using finite element models. 2. Non-linear analysis
-
Lotz J., Cheal E., Hayes W. Fracture prediction for the proximal femur using finite element models. 2. Non-linear analysis. Journal of Biomechanical Engineering 1991, 113:361-365.
-
(1991)
Journal of Biomechanical Engineering
, vol.113
, pp. 361-365
-
-
Lotz, J.1
Cheal, E.2
Hayes, W.3
-
14
-
-
0025836580
-
Fracture prediction for the proximal femur using finite element models: Part I-linear analysis
-
Lotz J.C. Fracture prediction for the proximal femur using finite element models: Part I-linear analysis. Journal of Biomechanical Engineering 1991, 113:353-360.
-
(1991)
Journal of Biomechanical Engineering
, vol.113
, pp. 353-360
-
-
Lotz, J.C.1
-
15
-
-
0031966115
-
High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties
-
Majumdar S., Kothari M., Augat P., Newitt D.C., Link T.M., Lin J.C., Lang T., Lu Y., Genant H.K. High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties. Bone 1998, 22:445-454.
-
(1998)
Bone
, vol.22
, pp. 445-454
-
-
Majumdar, S.1
Kothari, M.2
Augat, P.3
Newitt, D.C.4
Link, T.M.5
Lin, J.C.6
Lang, T.7
Lu, Y.8
Genant, H.K.9
-
16
-
-
0032998090
-
Fracture simulation of the femoral bone using the finite-element method: how a fracture initiates and proceeds
-
Ota T. Fracture simulation of the femoral bone using the finite-element method: how a fracture initiates and proceeds. Journal of Bone and Mineral Metabolism 1999, 17:108-112.
-
(1999)
Journal of Bone and Mineral Metabolism
, vol.17
, pp. 108-112
-
-
Ota, T.1
-
17
-
-
84862274814
-
HR-pQCT-based homogenised finite element models provide quantitative predictions of experimental vertebral body stiffness and strength with the same accuracy as μFE models
-
Pahr D.H., Dall'Ara E., Varga P., Zysset P.K. HR-pQCT-based homogenised finite element models provide quantitative predictions of experimental vertebral body stiffness and strength with the same accuracy as μFE models. Computer Methods in Biomechanics and Biomedical Engineering 2011, 15:711-720.
-
(2011)
Computer Methods in Biomechanics and Biomedical Engineering
, vol.15
, pp. 711-720
-
-
Pahr, D.H.1
Dall'Ara, E.2
Varga, P.3
Zysset, P.K.4
-
18
-
-
60549106824
-
A comparison of enhanced continuum FE with micro FE models of human vertebral bodies
-
Pahr D.H., Zysset P.K. A comparison of enhanced continuum FE with micro FE models of human vertebral bodies. Journal of Biomechanics 2009, 42:455-462.
-
(2009)
Journal of Biomechanics
, vol.42
, pp. 455-462
-
-
Pahr, D.H.1
Zysset, P.K.2
-
20
-
-
20244381352
-
Population-based study of age and sex differences in bone bolumetric density, size, geometry, and structure at different skeletal sites
-
Riggs B.L., Melton L.J., Robb R.A., Camp J.J., Atkinson E.J., Peterson J.M., Rouleau P.A., McCollough C.H., Bouxsein M.L., Khosla S. Population-based study of age and sex differences in bone bolumetric density, size, geometry, and structure at different skeletal sites. Journal of Bone and Mineral Research 2004, 19:1945-1954.
-
(2004)
Journal of Bone and Mineral Research
, vol.19
, pp. 1945-1954
-
-
Riggs, B.L.1
Melton, L.J.2
Robb, R.A.3
Camp, J.J.4
Atkinson, E.J.5
Peterson, J.M.6
Rouleau, P.A.7
McCollough, C.H.8
Bouxsein, M.L.9
Khosla, S.10
-
21
-
-
0034963420
-
Autocorrelation analysis of bone structure
-
Rotter M., Berg A., Langenberger H., Grampp S., Imhof H., Moser E. Autocorrelation analysis of bone structure. Journal of Magnetic Resonance Imaging 2001, 14:87-93.
-
(2001)
Journal of Magnetic Resonance Imaging
, vol.14
, pp. 87-93
-
-
Rotter, M.1
Berg, A.2
Langenberger, H.3
Grampp, S.4
Imhof, H.5
Moser, E.6
-
22
-
-
23844510870
-
Tensor scale: a local morphometric parameter with applications to computer vision and image processing
-
Saha P.K. Tensor scale: a local morphometric parameter with applications to computer vision and image processing. Computer Vision and Image Understanding 2005, 99:384-413.
-
(2005)
Computer Vision and Image Understanding
, vol.99
, pp. 384-413
-
-
Saha, P.K.1
-
23
-
-
84864555436
-
Orientation of orthotropic material properties in a femur FE model: a method based on the principal stresses directions
-
San Antonio T., Ciaccia M., Müller-Karger C., Casanova E. Orientation of orthotropic material properties in a femur FE model: a method based on the principal stresses directions. Medical Engineering and Physics 2012, 34:914-919.
-
(2012)
Medical Engineering and Physics
, vol.34
, pp. 914-919
-
-
San Antonio, T.1
Ciaccia, M.2
Müller-Karger, C.3
Casanova, E.4
-
24
-
-
84861338379
-
Equivalence of mean intercept length and gradient fabric tensors-3d study
-
Tabor Z. Equivalence of mean intercept length and gradient fabric tensors-3d study. Medical Engineering and Physics 2012, 34:598-604.
-
(2012)
Medical Engineering and Physics
, vol.34
, pp. 598-604
-
-
Tabor, Z.1
-
25
-
-
84871517361
-
The potential of multi-slice computed tomography based quantification of the structural anisotropy of vertebral trabecular bone
-
Tabor Z., Petryniak R., Latała Z., Konopka T. The potential of multi-slice computed tomography based quantification of the structural anisotropy of vertebral trabecular bone. Medical Engineering and Physics 2013, 35:7-15.
-
(2013)
Medical Engineering and Physics
, vol.35
, pp. 7-15
-
-
Tabor, Z.1
Petryniak, R.2
Latała, Z.3
Konopka, T.4
-
26
-
-
33847703730
-
Quantifying anisotropy of trabecular bone from gray-level images
-
Tabor Z., Rokita E. Quantifying anisotropy of trabecular bone from gray-level images. Bone 2007, 40:966-972.
-
(2007)
Bone
, vol.40
, pp. 966-972
-
-
Tabor, Z.1
Rokita, E.2
-
27
-
-
33748467122
-
Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy
-
Taddei F., Critofolini L., Martelli S., Gill H.S., Viceconti M. Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy. Journal of Biomechanics 2006, 39:2457-2467.
-
(2006)
Journal of Biomechanics
, vol.39
, pp. 2457-2467
-
-
Taddei, F.1
Critofolini, L.2
Martelli, S.3
Gill, H.S.4
Viceconti, M.5
-
28
-
-
79959410409
-
Patient-specific finite-element analyses of the proximal femur with orthotropic material properties validated by experiments
-
Trabelsi N., Yosibash Z. Patient-specific finite-element analyses of the proximal femur with orthotropic material properties validated by experiments. Journal of Biomechanical Engineering 2011, 133:061001.
-
(2011)
Journal of Biomechanical Engineering
, vol.133
, pp. 061001
-
-
Trabelsi, N.1
Yosibash, Z.2
-
29
-
-
67651160335
-
Validation of an anatomy specific finite element model of Colles' fracture
-
Varga P., Baumbach S., Pahr D., Zysset P.K. Validation of an anatomy specific finite element model of Colles' fracture. Journal of Biomechanics 2009, 42:1726-1731.
-
(2009)
Journal of Biomechanics
, vol.42
, pp. 1726-1731
-
-
Varga, P.1
Baumbach, S.2
Pahr, D.3
Zysset, P.K.4
-
30
-
-
67349091809
-
Sampling sphere orientation distribution: an efficient method to quantify trabecular bone fabric on grayscale images
-
Varga P., Zysset P.K. Sampling sphere orientation distribution: an efficient method to quantify trabecular bone fabric on grayscale images. Medical Image Analysis 2009, 13:530-541.
-
(2009)
Medical Image Analysis
, vol.13
, pp. 530-541
-
-
Varga, P.1
Zysset, P.K.2
-
31
-
-
33847656980
-
Spatial autocorrelation and mean intercept length analysis of trabecular bone anisotropy applied to in vivo magnetic resonance imaging
-
Wald M.J., Vasilic B., Saha P.K., Wehrli F.W. Spatial autocorrelation and mean intercept length analysis of trabecular bone anisotropy applied to in vivo magnetic resonance imaging. Medical Physics 2007, 34:1110-1120.
-
(2007)
Medical Physics
, vol.34
, pp. 1110-1120
-
-
Wald, M.J.1
Vasilic, B.2
Saha, P.K.3
Wehrli, F.W.4
-
32
-
-
0016242145
-
The quantitative morphology of anisotropic trabecular bone
-
Whitehouse W.J. The quantitative morphology of anisotropic trabecular bone. Journal of Microscopy 1974, 101:153-168.
-
(1974)
Journal of Microscopy
, vol.101
, pp. 153-168
-
-
Whitehouse, W.J.1
-
33
-
-
67649502328
-
Vertebral trabecular main direction can be determined from clinical CT datasets using the gradient structure tensor and not the inertia tensor-a case study
-
Wolfram U., Schmitz B., Heuer F., Reinehr M., Wilke H.-J. Vertebral trabecular main direction can be determined from clinical CT datasets using the gradient structure tensor and not the inertia tensor-a case study. Journal of Biomechanics 2009, 42:1390-1396.
-
(2009)
Journal of Biomechanics
, vol.42
, pp. 1390-1396
-
-
Wolfram, U.1
Schmitz, B.2
Heuer, F.3
Reinehr, M.4
Wilke, H.-J.5
-
34
-
-
0141565392
-
A review of morphology-elasticity relationships in human trabecular bone: theories and experiments
-
Zysset P.K. A review of morphology-elasticity relationships in human trabecular bone: theories and experiments. Journal of Biomechanics 2003, 36:1469-1485.
-
(2003)
Journal of Biomechanics
, vol.36
, pp. 1469-1485
-
-
Zysset, P.K.1
-
35
-
-
0029406775
-
An alternative model for anisotropic elasticity based on fabric tensors
-
Zysset P.K., Curnier A. An alternative model for anisotropic elasticity based on fabric tensors. Mechanics of Materials 1995, 21:243-250.
-
(1995)
Mechanics of Materials
, vol.21
, pp. 243-250
-
-
Zysset, P.K.1
Curnier, A.2
|