메뉴 건너뛰기




Volumn 48, Issue 9, 2013, Pages 1050-1058

LC-MS analysis of estradiol in human serum and endometrial tissue: Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization

Author keywords

estradiol; ionization; mass spectrometry; serum; tissue

Indexed keywords

ATMOSPHERIC PRESSURE CHEMICAL IONIZATION; ATMOSPHERIC PRESSURE PHOTO IONIZATION; CHROMATOGRAPHIC SEPARATIONS; ELECTROSPRAY IONIZATION (ESI); ESTRADIOL; IONIZATION TECHNIQUES; MULTIPLE REACTION MONITORING; SERUM;

EID: 84884899802     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.3252     Document Type: Article
Times cited : (42)

References (48)
  • 1
    • 0014526986 scopus 로고
    • Solid-phase radioimmunoassay of estradiol-17 beta
    • G. E. Abraham,. Solid-phase radioimmunoassay of estradiol-17 beta. J. Clin. Endocrinol. Metab. 1969, 29, 866-70.
    • (1969) J. Clin. Endocrinol. Metab. , vol.29 , pp. 866-870
    • Abraham, G.E.1
  • 2
    • 0023414442 scopus 로고
    • Discrepancies in plasma estradiol values obtained with commercial kits
    • J.A. Nisbet, P.A. Jomain,. Discrepancies in plasma estradiol values obtained with commercial kits. Clin. Chem. 1987, 33, 1672.
    • (1987) Clin. Chem. , vol.33 , pp. 1672
    • Nisbet, J.A.1    Jomain, P.A.2
  • 3
    • 0030751769 scopus 로고    scopus 로고
    • Falsely increased serum estradiol results reported in direct estradiol assays
    • Y.S. Leung, K. Dees, R. Cyr, I. Schloegel, P.C. Kao,. Falsely increased serum estradiol results reported in direct estradiol assays. Clin. Chem. 1997, 43, 1250.
    • (1997) Clin. Chem. , vol.43 , pp. 1250
    • Leung, Y.S.1    Dees, K.2    Cyr, R.3    Schloegel, I.4    Kao, P.C.5
  • 4
    • 0036183463 scopus 로고    scopus 로고
    • Limitations of steroid determination by direct immunoassay
    • J. Taieb, C. Benattar, A.S. Birr, A. Lindenbaum,. Limitations of steroid determination by direct immunoassay. Clin. Chem. 2002, 48, 583.
    • (2002) Clin. Chem. , vol.48 , pp. 583
    • Taieb, J.1    Benattar, C.2    Birr, A.S.3    Lindenbaum, A.4
  • 6
    • 13444251237 scopus 로고    scopus 로고
    • Deficits in plasma oestradiol measurement in studies and management of breast cancer
    • M. Dowsett, E. Folkerd,. Deficits in plasma oestradiol measurement in studies and management of breast cancer. Breast Cancer Res. 2005, 7, 1.
    • (2005) Breast Cancer Res. , vol.7 , pp. 1
    • Dowsett, M.1    Folkerd, E.2
  • 7
    • 38949117322 scopus 로고    scopus 로고
    • A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children
    • C. Ankarberg-Lindgren, E. Norjavaara,. A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children. Eur. J. Endocrinol. 2008, 158, 117.
    • (2008) Eur. J. Endocrinol. , vol.158 , pp. 117
    • Ankarberg-Lindgren, C.1    Norjavaara, E.2
  • 8
    • 84876544579 scopus 로고    scopus 로고
    • Deficiencies in immunoassay methods used to monitor serum Estradiol levels during aromatase inhibitor treatment in postmenopausal breast cancer patients
    • J. Jaque, H. Macdonald, D. Brueggmann, S.K. Patel, C. Azen, N. Clarke, F.Z. Stanczyk,. Deficiencies in immunoassay methods used to monitor serum Estradiol levels during aromatase inhibitor treatment in postmenopausal breast cancer patients. Springerplus 2013, 2, 5.
    • (2013) Springerplus , vol.2 , pp. 5
    • Jaque, J.1    Macdonald, H.2    Brueggmann, D.3    Patel, S.K.4    Azen, C.5    Clarke, N.6    Stanczyk, F.Z.7
  • 9
    • 33747846300 scopus 로고    scopus 로고
    • Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry
    • T. Guo, R.L. Taylor, R.J. Singh, S.J. Soldin,. Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry. Clin. Chim. Acta 2006, 372, 76.
    • (2006) Clin. Chim. Acta , vol.372 , pp. 76
    • Guo, T.1    Taylor, R.L.2    Singh, R.J.3    Soldin, S.J.4
  • 10
    • 43449100035 scopus 로고    scopus 로고
    • Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography-tandem mass spectrometry without derivatization
    • T. Guo, J. Gu, O.P. Soldin, R.J. Singh, S.J. Soldin,. Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography- tandem mass spectrometry without derivatization. Clin. Biochem. 2008, 41, 736.
    • (2008) Clin. Biochem. , vol.41 , pp. 736
    • Guo, T.1    Gu, J.2    Soldin, O.P.3    Singh, R.J.4    Soldin, S.J.5
  • 11
    • 58549112567 scopus 로고    scopus 로고
    • Rapid quantification of steroid patterns in human serum by on-line solid phase extraction combined with liquid chromatography-triple quadrupole linear ion trap mass spectrometry
    • U. Ceglarek, L. Kortz, A. Leichtle, G.M. Fiedler, J. Kratzsch, J. Thiery,. Rapid quantification of steroid patterns in human serum by on-line solid phase extraction combined with liquid chromatography-triple quadrupole linear ion trap mass spectrometry. Clin. Chim. Acta 2009, 401, 114.
    • (2009) Clin. Chim. Acta , vol.401 , pp. 114
    • Ceglarek, U.1    Kortz, L.2    Leichtle, A.3    Fiedler, G.M.4    Kratzsch, J.5    Thiery, J.6
  • 12
    • 70349819876 scopus 로고    scopus 로고
    • Development and validation of a sensitive liquid chromatography-tandem mass spectrometry assay to simultaneously measure androgens and estrogens in serum without derivatization
    • D.T. Harwood, D.J. Handelsman,. Development and validation of a sensitive liquid chromatography-tandem mass spectrometry assay to simultaneously measure androgens and estrogens in serum without derivatization. Clin. Chim. Acta 2009, 409, 78.
    • (2009) Clin. Chim. Acta , vol.409 , pp. 78
    • Harwood, D.T.1    Handelsman, D.J.2
  • 15
    • 77949263021 scopus 로고    scopus 로고
    • Analysis of estrogens in serum and plasma from postmenopausal women: Past present, and future
    • I.A. Blair,. Analysis of estrogens in serum and plasma from postmenopausal women: past present, and future. Steroids 2010, 75, 297.
    • (2010) Steroids , vol.75 , pp. 297
    • Blair, I.A.1
  • 16
    • 84862535206 scopus 로고    scopus 로고
    • Performance evaluation of Siemens ADVIA Centaur® enhanced estradiol assay and a split sample comparison with liquid chromatography-tandem mass spectrometry
    • Y. Chen, L. Kinney, S.J. Soldin,. Performance evaluation of Siemens ADVIA Centaur® enhanced estradiol assay and a split sample comparison with liquid chromatography-tandem mass spectrometry. Clin. Biochem. 2012, 5, 811.
    • (2012) Clin. Biochem. , vol.5 , pp. 811
    • Chen, Y.1    Kinney, L.2    Soldin, S.J.3
  • 17
    • 84868611284 scopus 로고    scopus 로고
    • Reference ranges and determinants of testosterone, dihydrotestosterone, and estradiol levels measured using liquid chromatography-tandem mass spectrometry in a population-based cohort of older men
    • B.B. Yeap, H. Alfonso, S.A. Chubb, D.J. Handelsman, G.J. Hankey, P.E. Norman, L. Flicker,. Reference ranges and determinants of testosterone, dihydrotestosterone, and estradiol levels measured using liquid chromatography-tandem mass spectrometry in a population-based cohort of older men. J. Clin. Endocrinol. Metab. 2012, 97, 4030.
    • (2012) J. Clin. Endocrinol. Metab. , vol.97 , pp. 4030
    • Yeap, B.B.1    Alfonso, H.2    Chubb, S.A.3    Handelsman, D.J.4    Hankey, G.J.5    Norman, P.E.6    Flicker, L.7
  • 18
    • 78650513033 scopus 로고    scopus 로고
    • Reexamination of testosterone, dihydrotestosterone, estradiol and estrone levels across the menstrual cycle and in postmenopausal women measured by liquid chromatography-tandem mass spectrometry
    • M.S. Rothman, N.E. Carlson, M. Xu, C. Wang, R. Swerdloff, P. Lee, V.H. Goh, E.C. Ridgway, M.E. Wierman,. Reexamination of testosterone, dihydrotestosterone, estradiol and estrone levels across the menstrual cycle and in postmenopausal women measured by liquid chromatography-tandem mass spectrometry. Steroids 2011, 76, 177.
    • (2011) Steroids , vol.76 , pp. 177
    • Rothman, M.S.1    Carlson, N.E.2    Xu, M.3    Wang, C.4    Swerdloff, R.5    Lee, P.6    Goh, V.H.7    Ridgway, E.C.8    Wierman, M.E.9
  • 20
    • 9644272537 scopus 로고    scopus 로고
    • Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry
    • M. Zhao, S.D. Baker, X. Yan, Y. Zhao, W.W. Wright, B.R. Zirkin, J.P. Jarow,. Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry. Steroids 2004, 69, 721.
    • (2004) Steroids , vol.69 , pp. 721
    • Zhao, M.1    Baker, S.D.2    Yan, X.3    Zhao, Y.4    Wright, W.W.5    Zirkin, B.R.6    Jarow, J.P.7
  • 21
    • 84865754143 scopus 로고    scopus 로고
    • The development and validation of a turbulent flow chromatography-tandem mass spectrometry method for the endogenous steroid profiling of equine serum
    • B.C. Moeller, S.D. Stanley,. The development and validation of a turbulent flow chromatography-tandem mass spectrometry method for the endogenous steroid profiling of equine serum. J. Chromatogr. B 2012, 905, 1.
    • (2012) J. Chromatogr. B , vol.905 , pp. 1
    • Moeller, B.C.1    Stanley, S.D.2
  • 22
    • 79952173245 scopus 로고    scopus 로고
    • Detection of low plasma estradiol concentrations in nesting green turtles (Chelonia mydas) by HPLC/Ms-Ms
    • I.Y. Mahmoud, A.Y. Alkindi, T. Khan, S.N. Al-Bahry,. Detection of low plasma estradiol concentrations in nesting green turtles (Chelonia mydas) by HPLC/Ms-Ms. J. Exp. Zool. A Ecol. Genet. Physiol. 2011, 315, 170.
    • (2011) J. Exp. Zool. A Ecol. Genet. Physiol. , vol.315 , pp. 170
    • Mahmoud, I.Y.1    Alkindi, A.Y.2    Khan, T.3    Al-Bahry, S.N.4
  • 23
    • 84859443929 scopus 로고    scopus 로고
    • Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatization
    • T. Fiers, B. Casetta, B. Bernaert, E. Vandersypt, M. Debock, J.M. Kaufman,. Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatization. J. Chromatogr. B 2012, 893-894, 57.
    • (2012) J. Chromatogr. B , vol.893-894 , pp. 57
    • Fiers, T.1    Casetta, B.2    Bernaert, B.3    Vandersypt, E.4    Debock, M.5    Kaufman, J.M.6
  • 24
    • 38349123293 scopus 로고    scopus 로고
    • Evaluation of neuroactive steroid levels by liquid chromatography-tandem mass spectrometry in central and peripheral nervous system: Effect of diabetes
    • D. Caruso, S. Scurati, O. Maschi, L. De Angelis, I. Roglio, S. Giatti, L.M. Garcia-Segura, R.C. Melcangi,. Evaluation of neuroactive steroid levels by liquid chromatography-tandem mass spectrometry in central and peripheral nervous system: effect of diabetes. Neurochem. Int. 2008, 52, 560.
    • (2008) Neurochem. Int. , vol.52 , pp. 560
    • Caruso, D.1    Scurati, S.2    Maschi, O.3    De Angelis, L.4    Roglio, I.5    Giatti, S.6    Garcia-Segura, L.M.7    Melcangi, R.C.8
  • 25
    • 84857550631 scopus 로고    scopus 로고
    • Sample preparation and liquid chromatography-tandem mass spectrometry for multiple steroids in mammalian and avian circulation
    • L. Koren, E.S. Ng, K.K. Soma, K.E. Wynne-Edwards,. Sample preparation and liquid chromatography-tandem mass spectrometry for multiple steroids in mammalian and avian circulation. PLoS One 2012, 7, e32496.
    • (2012) PLoS One , vol.7
    • Koren, L.1    Ng, E.S.2    Soma, K.K.3    Wynne-Edwards, K.E.4
  • 26
    • 78651242878 scopus 로고    scopus 로고
    • Determination of anabolic steroids in bovine serum by liquid chromatography-tandem mass spectrometry
    • G. Kaklamanos, G.A. Theodoridis, T. Dabalis, I. Papadoyannis,. Determination of anabolic steroids in bovine serum by liquid chromatography-tandem mass spectrometry. J. Chromatogr. B 2011, 879, 225.
    • (2011) J. Chromatogr. B , vol.879 , pp. 225
    • Kaklamanos, G.1    Theodoridis, G.A.2    Dabalis, T.3    Papadoyannis, I.4
  • 27
    • 1842531360 scopus 로고    scopus 로고
    • Steroid profiles using liquid chromatography-tandem mass spectrometry with atmospheric pressure photoionization source
    • T. Guo, M. Chan, S.J. Soldin,. Steroid profiles using liquid chromatography-tandem mass spectrometry with atmospheric pressure photoionization source. Arch. Pathol. Lab. Med. 2004, 128, 469.
    • (2004) Arch. Pathol. Lab. Med. , vol.128 , pp. 469
    • Guo, T.1    Chan, M.2    Soldin, S.J.3
  • 28
    • 0742287006 scopus 로고    scopus 로고
    • Liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of estradiol and estrone in human plasma
    • R.E. Nelson, S.K. Grebe, D.J. O'Kane, R.J. Singh,. Liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of estradiol and estrone in human plasma. Clin. Chem. 2004, 50, 373.
    • (2004) Clin. Chem. , vol.50 , pp. 373
    • Nelson, R.E.1    Grebe, S.K.2    O'Kane, D.J.3    Singh, R.J.4
  • 29
    • 26444496492 scopus 로고    scopus 로고
    • Development and evaluation of a reference measurement procedure for the determination of estradiol-17beta in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
    • S.S. Tai, M.J. Welch,. Development and evaluation of a reference measurement procedure for the determination of estradiol-17beta in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal. Chem. 2005, 77, 6359.
    • (2005) Anal. Chem. , vol.77 , pp. 6359
    • Tai, S.S.1    Welch, M.J.2
  • 30
    • 35448939711 scopus 로고    scopus 로고
    • Quantitative measurement of endogenous estrogens and estrogen metabolites in human serum by liquid chromatography-tandem mass spectrometry
    • X. Xu, J.M. Roman, H.J. Issaq, L.K. Keefer, T.D. Veenstra, R.G. Ziegler,. Quantitative measurement of endogenous estrogens and estrogen metabolites in human serum by liquid chromatography-tandem mass spectrometry. Anal. Chem. 2007, 79, 7813.
    • (2007) Anal. Chem. , vol.79 , pp. 7813
    • Xu, X.1    Roman, J.M.2    Issaq, H.J.3    Keefer, L.K.4    Veenstra, T.D.5    Ziegler, R.G.6
  • 31
    • 78650231839 scopus 로고    scopus 로고
    • Simultaneous quantification of four native estrogen hormones at trace levels in human cerebrospinal fluid using liquid chromatography-tandem mass spectrometry
    • H.P. Nguyen, L. Li, J.W. Gatson, D. Maass, J.G. Wigginton, J.W. Simpkins, K.A. Schug,. Simultaneous quantification of four native estrogen hormones at trace levels in human cerebrospinal fluid using liquid chromatography-tandem mass spectrometry. J. Pharm. Biomed. Anal. 2011, 54, 830.
    • (2011) J. Pharm. Biomed. Anal. , vol.54 , pp. 830
    • Nguyen, H.P.1    Li, L.2    Gatson, J.W.3    Maass, D.4    Wigginton, J.G.5    Simpkins, J.W.6    Schug, K.A.7
  • 32
    • 84859425453 scopus 로고    scopus 로고
    • Direct measurement of free estradiol in human serum by equilibrium dialysis-liquid chromatography-tandem mass spectrometry and reference intervals of free estradiol in women
    • J.A. Ray, M.M. Kushnir, A. Bunker, A.L. Rockwood, A.W. Meikle,. Direct measurement of free estradiol in human serum by equilibrium dialysis-liquid chromatography-tandem mass spectrometry and reference intervals of free estradiol in women. Clin. Chim. Acta 2012, 413, 1008.
    • (2012) Clin. Chim. Acta , vol.413 , pp. 1008
    • Ray, J.A.1    Kushnir, M.M.2    Bunker, A.3    Rockwood, A.L.4    Meikle, A.W.5
  • 33
    • 33745775407 scopus 로고    scopus 로고
    • Atmospheric pressure photoionization-mass spectrometry and atmospheric pressure chemical ionization-mass spectrometry of neurotransmitters
    • T.J. Kauppila, T. Nikkola, R.A. Ketola, R. Kostiainen,. Atmospheric pressure photoionization-mass spectrometry and atmospheric pressure chemical ionization-mass spectrometry of neurotransmitters. J. Mass Spectrom. 2006, 41, 781.
    • (2006) J. Mass Spectrom. , vol.41 , pp. 781
    • Kauppila, T.J.1    Nikkola, T.2    Ketola, R.A.3    Kostiainen, R.4
  • 34
    • 50149109377 scopus 로고    scopus 로고
    • Analysis of natural and synthetic estrogenic endocrine disruptors in environmental waters using online preconcentration coupled with LC-APPI-MS/MS
    • L. Viglino, K. Aboulfadl, M. Prévost, S. Sauvé,. Analysis of natural and synthetic estrogenic endocrine disruptors in environmental waters using online preconcentration coupled with LC-APPI-MS/MS. Talanta 2008, 76, 1088.
    • (2008) Talanta , vol.76 , pp. 1088
    • Viglino, L.1    Aboulfadl, K.2    Prévost, M.3    Sauvé, S.4
  • 35
    • 58149459568 scopus 로고    scopus 로고
    • Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization for determining estrogenic chemicals in water by liquid chromatography tandem mass spectrometry with chemical derivatizations
    • G.W. Lien, C.Y. Chen, G.S. Wang,. Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization for determining estrogenic chemicals in water by liquid chromatography tandem mass spectrometry with chemical derivatizations. J. Chromatog. A 2009, 1216, 956.
    • (2009) J. Chromatog. A , vol.1216 , pp. 956
    • Lien, G.W.1    Chen, C.Y.2    Wang, G.S.3
  • 36
    • 79953114904 scopus 로고    scopus 로고
    • On-line two-dimensional liquid chromatography-tandem mass spectrometric determination of estrogens in sediments
    • D. Matějíček,. On-line two-dimensional liquid chromatography-tandem mass spectrometric determination of estrogens in sediments. J. Chromatogr. A 2011, 1218, 2292.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 2292
    • Matějíček, D.1
  • 37
    • 84857782736 scopus 로고    scopus 로고
    • Multi heart-cutting two-dimensional liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry method for the determination of endocrine disrupting compounds in water
    • D. Matějíček,. Multi heart-cutting two-dimensional liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry method for the determination of endocrine disrupting compounds in water. J. Chromatogr. A 2012, 1231, 52.
    • (2012) J. Chromatogr. A , vol.1231 , pp. 52
    • Matějíček, D.1
  • 38
    • 84867000518 scopus 로고    scopus 로고
    • Comparison of multiple API techniques for the simultaneous detection of microconstituents in water by on-line SPE-LC-MS/MS
    • C. Wang, P.R. Gardinali,. Comparison of multiple API techniques for the simultaneous detection of microconstituents in water by on-line SPE-LC-MS/MS. J. Mass Spectrom. 2012, 47, 1255.
    • (2012) J. Mass Spectrom. , vol.47 , pp. 1255
    • Wang, C.1    Gardinali, P.R.2
  • 40
    • 84868620900 scopus 로고    scopus 로고
    • Endometrial and endometriotic concentrations of estrone and estradiol are determined by local metabolism rather than circulating levels
    • K. Huhtinen, R. Desai, M. Ståhle, A. Salminen, D.J. Handelsman, A. Perheentupa, M. Poutanen,. Endometrial and endometriotic concentrations of estrone and estradiol are determined by local metabolism rather than circulating levels. J. Clin. Endocrinol. Metab. 2012, 97, 4228.
    • (2012) J. Clin. Endocrinol. Metab. , vol.97 , pp. 4228
    • Huhtinen, K.1    Desai, R.2    Ståhle, M.3    Salminen, A.4    Handelsman, D.J.5    Perheentupa, A.6    Poutanen, M.7
  • 41
    • 81255167995 scopus 로고    scopus 로고
    • Fast and sensitive liquid chromatography-mass spectrometry assay for seven androgenic and progestagenic steroids in human serum
    • P. Keski-Rahkonen, K. Huhtinen, M. Poutanen, S. Auriola,. Fast and sensitive liquid chromatography-mass spectrometry assay for seven androgenic and progestagenic steroids in human serum. J. Steroid Biochem. Mol. Biol. 2011, 127, 396.
    • (2011) J. Steroid Biochem. Mol. Biol. , vol.127 , pp. 396
    • Keski-Rahkonen, P.1    Huhtinen, K.2    Poutanen, M.3    Auriola, S.4
  • 42
    • 0003484310 scopus 로고    scopus 로고
    • US Department of Health and Human Services, Food and Drug Administration
    • Guidance for Industry, Bioanalytical Method Validation, US Department of Health and Human Services, Food and Drug Administration, 2001. www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/ UCM070107.pdf.
    • (2001) Guidance for Industry, Bioanalytical Method Validation
  • 43
    • 79954434807 scopus 로고    scopus 로고
    • Sensitive measurement of serum 1α,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction
    • C. Yuan, J. Kosewick, X. He, M. Kozak, S. Wang,. Sensitive measurement of serum 1α,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction. Rapid Commun. Mass Spectrom. 2011, 25, 1241.
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , pp. 1241
    • Yuan, C.1    Kosewick, J.2    He, X.3    Kozak, M.4    Wang, S.5
  • 44
    • 0018652753 scopus 로고
    • PKa values of estrone, 17 beta-estradiol and 2-methoxyestrone
    • K.M. Lewis, R.D. Archer,. pKa values of estrone, 17 beta-estradiol and 2-methoxyestrone. Steroids 1979, 34, 485.
    • (1979) Steroids , vol.34 , pp. 485
    • Lewis, K.M.1    Archer, R.D.2
  • 45
    • 58149112644 scopus 로고    scopus 로고
    • Effect of eluent on the ionization process in liquid chromatography-mass spectrometry
    • R. Kostiainen, T.J. Kauppila,. Effect of eluent on the ionization process in liquid chromatography-mass spectrometry. J. Chromatogr. A 2009, 1216, 685.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 685
    • Kostiainen, R.1    Kauppila, T.J.2
  • 47
    • 0037663202 scopus 로고    scopus 로고
    • Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS-MS
    • B.K. Matuszewski, M.L. Constanzer, C.M. Chavez-Eng,. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS-MS. Anal. Chem. 2003, 75, 3019.
    • (2003) Anal. Chem. , vol.75 , pp. 3019
    • Matuszewski, B.K.1    Constanzer, M.L.2    Chavez-Eng, C.M.3
  • 48
    • 55549143295 scopus 로고    scopus 로고
    • Quantitative determination of endogenous compounds in biological samples using chromatographic techniques
    • N.C. van de Merbel,. Quantitative determination of endogenous compounds in biological samples using chromatographic techniques. Trends Anal. Chem. 2008, 27, 924.
    • (2008) Trends Anal. Chem. , vol.27 , pp. 924
    • Van De Merbel, N.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.