-
1
-
-
0014526986
-
Solid-phase radioimmunoassay of estradiol-17 beta
-
G. E. Abraham,. Solid-phase radioimmunoassay of estradiol-17 beta. J. Clin. Endocrinol. Metab. 1969, 29, 866-70.
-
(1969)
J. Clin. Endocrinol. Metab.
, vol.29
, pp. 866-870
-
-
Abraham, G.E.1
-
2
-
-
0023414442
-
Discrepancies in plasma estradiol values obtained with commercial kits
-
J.A. Nisbet, P.A. Jomain,. Discrepancies in plasma estradiol values obtained with commercial kits. Clin. Chem. 1987, 33, 1672.
-
(1987)
Clin. Chem.
, vol.33
, pp. 1672
-
-
Nisbet, J.A.1
Jomain, P.A.2
-
3
-
-
0030751769
-
Falsely increased serum estradiol results reported in direct estradiol assays
-
Y.S. Leung, K. Dees, R. Cyr, I. Schloegel, P.C. Kao,. Falsely increased serum estradiol results reported in direct estradiol assays. Clin. Chem. 1997, 43, 1250.
-
(1997)
Clin. Chem.
, vol.43
, pp. 1250
-
-
Leung, Y.S.1
Dees, K.2
Cyr, R.3
Schloegel, I.4
Kao, P.C.5
-
4
-
-
0036183463
-
Limitations of steroid determination by direct immunoassay
-
J. Taieb, C. Benattar, A.S. Birr, A. Lindenbaum,. Limitations of steroid determination by direct immunoassay. Clin. Chem. 2002, 48, 583.
-
(2002)
Clin. Chem.
, vol.48
, pp. 583
-
-
Taieb, J.1
Benattar, C.2
Birr, A.S.3
Lindenbaum, A.4
-
5
-
-
0344393459
-
Limitations of direct estradiol and testosterone immunoassay kits
-
F.Z. Stanczyk, M.M. Cho, D.B. Endres, J.L. Morrison, S. Patel, R.J. Paulson,. Limitations of direct estradiol and testosterone immunoassay kits. Steroids 2003, 68, 1173.
-
(2003)
Steroids
, vol.68
, pp. 1173
-
-
Stanczyk, F.Z.1
Cho, M.M.2
Endres, D.B.3
Morrison, J.L.4
Patel, S.5
Paulson, R.J.6
-
6
-
-
13444251237
-
Deficits in plasma oestradiol measurement in studies and management of breast cancer
-
M. Dowsett, E. Folkerd,. Deficits in plasma oestradiol measurement in studies and management of breast cancer. Breast Cancer Res. 2005, 7, 1.
-
(2005)
Breast Cancer Res.
, vol.7
, pp. 1
-
-
Dowsett, M.1
Folkerd, E.2
-
7
-
-
38949117322
-
A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children
-
C. Ankarberg-Lindgren, E. Norjavaara,. A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children. Eur. J. Endocrinol. 2008, 158, 117.
-
(2008)
Eur. J. Endocrinol.
, vol.158
, pp. 117
-
-
Ankarberg-Lindgren, C.1
Norjavaara, E.2
-
8
-
-
84876544579
-
Deficiencies in immunoassay methods used to monitor serum Estradiol levels during aromatase inhibitor treatment in postmenopausal breast cancer patients
-
J. Jaque, H. Macdonald, D. Brueggmann, S.K. Patel, C. Azen, N. Clarke, F.Z. Stanczyk,. Deficiencies in immunoassay methods used to monitor serum Estradiol levels during aromatase inhibitor treatment in postmenopausal breast cancer patients. Springerplus 2013, 2, 5.
-
(2013)
Springerplus
, vol.2
, pp. 5
-
-
Jaque, J.1
Macdonald, H.2
Brueggmann, D.3
Patel, S.K.4
Azen, C.5
Clarke, N.6
Stanczyk, F.Z.7
-
9
-
-
33747846300
-
Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry
-
T. Guo, R.L. Taylor, R.J. Singh, S.J. Soldin,. Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry. Clin. Chim. Acta 2006, 372, 76.
-
(2006)
Clin. Chim. Acta
, vol.372
, pp. 76
-
-
Guo, T.1
Taylor, R.L.2
Singh, R.J.3
Soldin, S.J.4
-
10
-
-
43449100035
-
Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography-tandem mass spectrometry without derivatization
-
T. Guo, J. Gu, O.P. Soldin, R.J. Singh, S.J. Soldin,. Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography- tandem mass spectrometry without derivatization. Clin. Biochem. 2008, 41, 736.
-
(2008)
Clin. Biochem.
, vol.41
, pp. 736
-
-
Guo, T.1
Gu, J.2
Soldin, O.P.3
Singh, R.J.4
Soldin, S.J.5
-
11
-
-
58549112567
-
Rapid quantification of steroid patterns in human serum by on-line solid phase extraction combined with liquid chromatography-triple quadrupole linear ion trap mass spectrometry
-
U. Ceglarek, L. Kortz, A. Leichtle, G.M. Fiedler, J. Kratzsch, J. Thiery,. Rapid quantification of steroid patterns in human serum by on-line solid phase extraction combined with liquid chromatography-triple quadrupole linear ion trap mass spectrometry. Clin. Chim. Acta 2009, 401, 114.
-
(2009)
Clin. Chim. Acta
, vol.401
, pp. 114
-
-
Ceglarek, U.1
Kortz, L.2
Leichtle, A.3
Fiedler, G.M.4
Kratzsch, J.5
Thiery, J.6
-
12
-
-
70349819876
-
Development and validation of a sensitive liquid chromatography-tandem mass spectrometry assay to simultaneously measure androgens and estrogens in serum without derivatization
-
D.T. Harwood, D.J. Handelsman,. Development and validation of a sensitive liquid chromatography-tandem mass spectrometry assay to simultaneously measure androgens and estrogens in serum without derivatization. Clin. Chim. Acta 2009, 409, 78.
-
(2009)
Clin. Chim. Acta
, vol.409
, pp. 78
-
-
Harwood, D.T.1
Handelsman, D.J.2
-
13
-
-
84858258974
-
Standardized LC-MS/MS based steroid hormone profile-analysis
-
T. Koal, D. Schmiederer, H. Pham-Tuan, C. Röhring, M. Rauh,. Standardized LC-MS/MS based steroid hormone profile-analysis. J. Steroid Biochem. Mol. Biol. 2012, 129, 129.
-
(2012)
J. Steroid Biochem. Mol. Biol.
, vol.129
, pp. 129
-
-
Koal, T.1
Schmiederer, D.2
Pham-Tuan, H.3
Röhring, C.4
Rauh, M.5
-
14
-
-
42949129215
-
High-Sensitivity Tandem Mass Spectrometry Assay for Serum Estrone and Estradiol
-
M.M. Kushnir, A.L. Rockwood, J. Bergquist, M. Varshavsky, W.L. Roberts, B. Yue, A.M. Bunker, A.W. Meikle,. High-Sensitivity Tandem Mass Spectrometry Assay for Serum Estrone and Estradiol. Am. J. Clin. Pathol. 2008, 129, 530.
-
(2008)
Am. J. Clin. Pathol.
, vol.129
, pp. 530
-
-
Kushnir, M.M.1
Rockwood, A.L.2
Bergquist, J.3
Varshavsky, M.4
Roberts, W.L.5
Yue, B.6
Bunker, A.M.7
Meikle, A.W.8
-
15
-
-
77949263021
-
Analysis of estrogens in serum and plasma from postmenopausal women: Past present, and future
-
I.A. Blair,. Analysis of estrogens in serum and plasma from postmenopausal women: past present, and future. Steroids 2010, 75, 297.
-
(2010)
Steroids
, vol.75
, pp. 297
-
-
Blair, I.A.1
-
16
-
-
84862535206
-
Performance evaluation of Siemens ADVIA Centaur® enhanced estradiol assay and a split sample comparison with liquid chromatography-tandem mass spectrometry
-
Y. Chen, L. Kinney, S.J. Soldin,. Performance evaluation of Siemens ADVIA Centaur® enhanced estradiol assay and a split sample comparison with liquid chromatography-tandem mass spectrometry. Clin. Biochem. 2012, 5, 811.
-
(2012)
Clin. Biochem.
, vol.5
, pp. 811
-
-
Chen, Y.1
Kinney, L.2
Soldin, S.J.3
-
17
-
-
84868611284
-
Reference ranges and determinants of testosterone, dihydrotestosterone, and estradiol levels measured using liquid chromatography-tandem mass spectrometry in a population-based cohort of older men
-
B.B. Yeap, H. Alfonso, S.A. Chubb, D.J. Handelsman, G.J. Hankey, P.E. Norman, L. Flicker,. Reference ranges and determinants of testosterone, dihydrotestosterone, and estradiol levels measured using liquid chromatography-tandem mass spectrometry in a population-based cohort of older men. J. Clin. Endocrinol. Metab. 2012, 97, 4030.
-
(2012)
J. Clin. Endocrinol. Metab.
, vol.97
, pp. 4030
-
-
Yeap, B.B.1
Alfonso, H.2
Chubb, S.A.3
Handelsman, D.J.4
Hankey, G.J.5
Norman, P.E.6
Flicker, L.7
-
18
-
-
78650513033
-
Reexamination of testosterone, dihydrotestosterone, estradiol and estrone levels across the menstrual cycle and in postmenopausal women measured by liquid chromatography-tandem mass spectrometry
-
M.S. Rothman, N.E. Carlson, M. Xu, C. Wang, R. Swerdloff, P. Lee, V.H. Goh, E.C. Ridgway, M.E. Wierman,. Reexamination of testosterone, dihydrotestosterone, estradiol and estrone levels across the menstrual cycle and in postmenopausal women measured by liquid chromatography-tandem mass spectrometry. Steroids 2011, 76, 177.
-
(2011)
Steroids
, vol.76
, pp. 177
-
-
Rothman, M.S.1
Carlson, N.E.2
Xu, M.3
Wang, C.4
Swerdloff, R.5
Lee, P.6
Goh, V.H.7
Ridgway, E.C.8
Wierman, M.E.9
-
19
-
-
84876229350
-
Challenges to the Measurement of Estradiol: An Endocrine Society Position Statement
-
W. Rosner, S.E. Hankinson, P.M. Sluss, H.W. Vesper, M.E. Wierman,. Challenges to the Measurement of Estradiol: An Endocrine Society Position Statement. J. Clin. Endocrinol. Metab. 2013, 98, 1376.
-
(2013)
J. Clin. Endocrinol. Metab.
, vol.98
, pp. 1376
-
-
Rosner, W.1
Hankinson, S.E.2
Sluss, P.M.3
Vesper, H.W.4
Wierman, M.E.5
-
20
-
-
9644272537
-
Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry
-
M. Zhao, S.D. Baker, X. Yan, Y. Zhao, W.W. Wright, B.R. Zirkin, J.P. Jarow,. Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry. Steroids 2004, 69, 721.
-
(2004)
Steroids
, vol.69
, pp. 721
-
-
Zhao, M.1
Baker, S.D.2
Yan, X.3
Zhao, Y.4
Wright, W.W.5
Zirkin, B.R.6
Jarow, J.P.7
-
21
-
-
84865754143
-
The development and validation of a turbulent flow chromatography-tandem mass spectrometry method for the endogenous steroid profiling of equine serum
-
B.C. Moeller, S.D. Stanley,. The development and validation of a turbulent flow chromatography-tandem mass spectrometry method for the endogenous steroid profiling of equine serum. J. Chromatogr. B 2012, 905, 1.
-
(2012)
J. Chromatogr. B
, vol.905
, pp. 1
-
-
Moeller, B.C.1
Stanley, S.D.2
-
22
-
-
79952173245
-
Detection of low plasma estradiol concentrations in nesting green turtles (Chelonia mydas) by HPLC/Ms-Ms
-
I.Y. Mahmoud, A.Y. Alkindi, T. Khan, S.N. Al-Bahry,. Detection of low plasma estradiol concentrations in nesting green turtles (Chelonia mydas) by HPLC/Ms-Ms. J. Exp. Zool. A Ecol. Genet. Physiol. 2011, 315, 170.
-
(2011)
J. Exp. Zool. A Ecol. Genet. Physiol.
, vol.315
, pp. 170
-
-
Mahmoud, I.Y.1
Alkindi, A.Y.2
Khan, T.3
Al-Bahry, S.N.4
-
23
-
-
84859443929
-
Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatization
-
T. Fiers, B. Casetta, B. Bernaert, E. Vandersypt, M. Debock, J.M. Kaufman,. Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatization. J. Chromatogr. B 2012, 893-894, 57.
-
(2012)
J. Chromatogr. B
, vol.893-894
, pp. 57
-
-
Fiers, T.1
Casetta, B.2
Bernaert, B.3
Vandersypt, E.4
Debock, M.5
Kaufman, J.M.6
-
24
-
-
38349123293
-
Evaluation of neuroactive steroid levels by liquid chromatography-tandem mass spectrometry in central and peripheral nervous system: Effect of diabetes
-
D. Caruso, S. Scurati, O. Maschi, L. De Angelis, I. Roglio, S. Giatti, L.M. Garcia-Segura, R.C. Melcangi,. Evaluation of neuroactive steroid levels by liquid chromatography-tandem mass spectrometry in central and peripheral nervous system: effect of diabetes. Neurochem. Int. 2008, 52, 560.
-
(2008)
Neurochem. Int.
, vol.52
, pp. 560
-
-
Caruso, D.1
Scurati, S.2
Maschi, O.3
De Angelis, L.4
Roglio, I.5
Giatti, S.6
Garcia-Segura, L.M.7
Melcangi, R.C.8
-
25
-
-
84857550631
-
Sample preparation and liquid chromatography-tandem mass spectrometry for multiple steroids in mammalian and avian circulation
-
L. Koren, E.S. Ng, K.K. Soma, K.E. Wynne-Edwards,. Sample preparation and liquid chromatography-tandem mass spectrometry for multiple steroids in mammalian and avian circulation. PLoS One 2012, 7, e32496.
-
(2012)
PLoS One
, vol.7
-
-
Koren, L.1
Ng, E.S.2
Soma, K.K.3
Wynne-Edwards, K.E.4
-
26
-
-
78651242878
-
Determination of anabolic steroids in bovine serum by liquid chromatography-tandem mass spectrometry
-
G. Kaklamanos, G.A. Theodoridis, T. Dabalis, I. Papadoyannis,. Determination of anabolic steroids in bovine serum by liquid chromatography-tandem mass spectrometry. J. Chromatogr. B 2011, 879, 225.
-
(2011)
J. Chromatogr. B
, vol.879
, pp. 225
-
-
Kaklamanos, G.1
Theodoridis, G.A.2
Dabalis, T.3
Papadoyannis, I.4
-
27
-
-
1842531360
-
Steroid profiles using liquid chromatography-tandem mass spectrometry with atmospheric pressure photoionization source
-
T. Guo, M. Chan, S.J. Soldin,. Steroid profiles using liquid chromatography-tandem mass spectrometry with atmospheric pressure photoionization source. Arch. Pathol. Lab. Med. 2004, 128, 469.
-
(2004)
Arch. Pathol. Lab. Med.
, vol.128
, pp. 469
-
-
Guo, T.1
Chan, M.2
Soldin, S.J.3
-
28
-
-
0742287006
-
Liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of estradiol and estrone in human plasma
-
R.E. Nelson, S.K. Grebe, D.J. O'Kane, R.J. Singh,. Liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of estradiol and estrone in human plasma. Clin. Chem. 2004, 50, 373.
-
(2004)
Clin. Chem.
, vol.50
, pp. 373
-
-
Nelson, R.E.1
Grebe, S.K.2
O'Kane, D.J.3
Singh, R.J.4
-
29
-
-
26444496492
-
Development and evaluation of a reference measurement procedure for the determination of estradiol-17beta in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
-
S.S. Tai, M.J. Welch,. Development and evaluation of a reference measurement procedure for the determination of estradiol-17beta in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal. Chem. 2005, 77, 6359.
-
(2005)
Anal. Chem.
, vol.77
, pp. 6359
-
-
Tai, S.S.1
Welch, M.J.2
-
30
-
-
35448939711
-
Quantitative measurement of endogenous estrogens and estrogen metabolites in human serum by liquid chromatography-tandem mass spectrometry
-
X. Xu, J.M. Roman, H.J. Issaq, L.K. Keefer, T.D. Veenstra, R.G. Ziegler,. Quantitative measurement of endogenous estrogens and estrogen metabolites in human serum by liquid chromatography-tandem mass spectrometry. Anal. Chem. 2007, 79, 7813.
-
(2007)
Anal. Chem.
, vol.79
, pp. 7813
-
-
Xu, X.1
Roman, J.M.2
Issaq, H.J.3
Keefer, L.K.4
Veenstra, T.D.5
Ziegler, R.G.6
-
31
-
-
78650231839
-
Simultaneous quantification of four native estrogen hormones at trace levels in human cerebrospinal fluid using liquid chromatography-tandem mass spectrometry
-
H.P. Nguyen, L. Li, J.W. Gatson, D. Maass, J.G. Wigginton, J.W. Simpkins, K.A. Schug,. Simultaneous quantification of four native estrogen hormones at trace levels in human cerebrospinal fluid using liquid chromatography-tandem mass spectrometry. J. Pharm. Biomed. Anal. 2011, 54, 830.
-
(2011)
J. Pharm. Biomed. Anal.
, vol.54
, pp. 830
-
-
Nguyen, H.P.1
Li, L.2
Gatson, J.W.3
Maass, D.4
Wigginton, J.G.5
Simpkins, J.W.6
Schug, K.A.7
-
32
-
-
84859425453
-
Direct measurement of free estradiol in human serum by equilibrium dialysis-liquid chromatography-tandem mass spectrometry and reference intervals of free estradiol in women
-
J.A. Ray, M.M. Kushnir, A. Bunker, A.L. Rockwood, A.W. Meikle,. Direct measurement of free estradiol in human serum by equilibrium dialysis-liquid chromatography-tandem mass spectrometry and reference intervals of free estradiol in women. Clin. Chim. Acta 2012, 413, 1008.
-
(2012)
Clin. Chim. Acta
, vol.413
, pp. 1008
-
-
Ray, J.A.1
Kushnir, M.M.2
Bunker, A.3
Rockwood, A.L.4
Meikle, A.W.5
-
33
-
-
33745775407
-
Atmospheric pressure photoionization-mass spectrometry and atmospheric pressure chemical ionization-mass spectrometry of neurotransmitters
-
T.J. Kauppila, T. Nikkola, R.A. Ketola, R. Kostiainen,. Atmospheric pressure photoionization-mass spectrometry and atmospheric pressure chemical ionization-mass spectrometry of neurotransmitters. J. Mass Spectrom. 2006, 41, 781.
-
(2006)
J. Mass Spectrom.
, vol.41
, pp. 781
-
-
Kauppila, T.J.1
Nikkola, T.2
Ketola, R.A.3
Kostiainen, R.4
-
34
-
-
50149109377
-
Analysis of natural and synthetic estrogenic endocrine disruptors in environmental waters using online preconcentration coupled with LC-APPI-MS/MS
-
L. Viglino, K. Aboulfadl, M. Prévost, S. Sauvé,. Analysis of natural and synthetic estrogenic endocrine disruptors in environmental waters using online preconcentration coupled with LC-APPI-MS/MS. Talanta 2008, 76, 1088.
-
(2008)
Talanta
, vol.76
, pp. 1088
-
-
Viglino, L.1
Aboulfadl, K.2
Prévost, M.3
Sauvé, S.4
-
35
-
-
58149459568
-
Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization for determining estrogenic chemicals in water by liquid chromatography tandem mass spectrometry with chemical derivatizations
-
G.W. Lien, C.Y. Chen, G.S. Wang,. Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization for determining estrogenic chemicals in water by liquid chromatography tandem mass spectrometry with chemical derivatizations. J. Chromatog. A 2009, 1216, 956.
-
(2009)
J. Chromatog. A
, vol.1216
, pp. 956
-
-
Lien, G.W.1
Chen, C.Y.2
Wang, G.S.3
-
36
-
-
79953114904
-
On-line two-dimensional liquid chromatography-tandem mass spectrometric determination of estrogens in sediments
-
D. Matějíček,. On-line two-dimensional liquid chromatography-tandem mass spectrometric determination of estrogens in sediments. J. Chromatogr. A 2011, 1218, 2292.
-
(2011)
J. Chromatogr. A
, vol.1218
, pp. 2292
-
-
Matějíček, D.1
-
37
-
-
84857782736
-
Multi heart-cutting two-dimensional liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry method for the determination of endocrine disrupting compounds in water
-
D. Matějíček,. Multi heart-cutting two-dimensional liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry method for the determination of endocrine disrupting compounds in water. J. Chromatogr. A 2012, 1231, 52.
-
(2012)
J. Chromatogr. A
, vol.1231
, pp. 52
-
-
Matějíček, D.1
-
38
-
-
84867000518
-
Comparison of multiple API techniques for the simultaneous detection of microconstituents in water by on-line SPE-LC-MS/MS
-
C. Wang, P.R. Gardinali,. Comparison of multiple API techniques for the simultaneous detection of microconstituents in water by on-line SPE-LC-MS/MS. J. Mass Spectrom. 2012, 47, 1255.
-
(2012)
J. Mass Spectrom.
, vol.47
, pp. 1255
-
-
Wang, C.1
Gardinali, P.R.2
-
39
-
-
64949192073
-
Serum HE4 concentration differentiates malignant ovarian tumours from ovarian endometriotic cysts
-
K. Huhtinen, P. Suvitie, J. Hiissa, J. Junnila, J. Huvila, H. Kujari, M. Setälä, P. Härkki, J. Jalkanen, J. Fraser, J. Mäkinen, A. Auranen, M. Poutanen, A. Perheentupa,. Serum HE4 concentration differentiates malignant ovarian tumours from ovarian endometriotic cysts. Br. J. Cancer 2009, 100, 1315.
-
(2009)
Br. J. Cancer
, vol.100
, pp. 1315
-
-
Huhtinen, K.1
Suvitie, P.2
Hiissa, J.3
Junnila, J.4
Huvila, J.5
Kujari, H.6
Setälä, M.7
Härkki, P.8
Jalkanen, J.9
Fraser, J.10
Mäkinen, J.11
Auranen, A.12
Poutanen, M.13
Perheentupa, A.14
-
40
-
-
84868620900
-
Endometrial and endometriotic concentrations of estrone and estradiol are determined by local metabolism rather than circulating levels
-
K. Huhtinen, R. Desai, M. Ståhle, A. Salminen, D.J. Handelsman, A. Perheentupa, M. Poutanen,. Endometrial and endometriotic concentrations of estrone and estradiol are determined by local metabolism rather than circulating levels. J. Clin. Endocrinol. Metab. 2012, 97, 4228.
-
(2012)
J. Clin. Endocrinol. Metab.
, vol.97
, pp. 4228
-
-
Huhtinen, K.1
Desai, R.2
Ståhle, M.3
Salminen, A.4
Handelsman, D.J.5
Perheentupa, A.6
Poutanen, M.7
-
41
-
-
81255167995
-
Fast and sensitive liquid chromatography-mass spectrometry assay for seven androgenic and progestagenic steroids in human serum
-
P. Keski-Rahkonen, K. Huhtinen, M. Poutanen, S. Auriola,. Fast and sensitive liquid chromatography-mass spectrometry assay for seven androgenic and progestagenic steroids in human serum. J. Steroid Biochem. Mol. Biol. 2011, 127, 396.
-
(2011)
J. Steroid Biochem. Mol. Biol.
, vol.127
, pp. 396
-
-
Keski-Rahkonen, P.1
Huhtinen, K.2
Poutanen, M.3
Auriola, S.4
-
42
-
-
0003484310
-
-
US Department of Health and Human Services, Food and Drug Administration
-
Guidance for Industry, Bioanalytical Method Validation, US Department of Health and Human Services, Food and Drug Administration, 2001. www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/ UCM070107.pdf.
-
(2001)
Guidance for Industry, Bioanalytical Method Validation
-
-
-
43
-
-
79954434807
-
Sensitive measurement of serum 1α,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction
-
C. Yuan, J. Kosewick, X. He, M. Kozak, S. Wang,. Sensitive measurement of serum 1α,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction. Rapid Commun. Mass Spectrom. 2011, 25, 1241.
-
(2011)
Rapid Commun. Mass Spectrom.
, vol.25
, pp. 1241
-
-
Yuan, C.1
Kosewick, J.2
He, X.3
Kozak, M.4
Wang, S.5
-
44
-
-
0018652753
-
PKa values of estrone, 17 beta-estradiol and 2-methoxyestrone
-
K.M. Lewis, R.D. Archer,. pKa values of estrone, 17 beta-estradiol and 2-methoxyestrone. Steroids 1979, 34, 485.
-
(1979)
Steroids
, vol.34
, pp. 485
-
-
Lewis, K.M.1
Archer, R.D.2
-
45
-
-
58149112644
-
Effect of eluent on the ionization process in liquid chromatography-mass spectrometry
-
R. Kostiainen, T.J. Kauppila,. Effect of eluent on the ionization process in liquid chromatography-mass spectrometry. J. Chromatogr. A 2009, 1216, 685.
-
(2009)
J. Chromatogr. A
, vol.1216
, pp. 685
-
-
Kostiainen, R.1
Kauppila, T.J.2
-
46
-
-
0034487744
-
Mechanistic investigation of ionization suppression in electrospray ionization
-
R. King, R. Bonfiglio, C. Fernandez-Metzler, C. Miller-Stein, T. Olah,. Mechanistic investigation of ionization suppression in electrospray ionization. J. Am. Soc. Mass Spectrom. 2000, 11, 942.
-
(2000)
J. Am. Soc. Mass Spectrom.
, vol.11
, pp. 942
-
-
King, R.1
Bonfiglio, R.2
Fernandez-Metzler, C.3
Miller-Stein, C.4
Olah, T.5
-
47
-
-
0037663202
-
Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS-MS
-
B.K. Matuszewski, M.L. Constanzer, C.M. Chavez-Eng,. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS-MS. Anal. Chem. 2003, 75, 3019.
-
(2003)
Anal. Chem.
, vol.75
, pp. 3019
-
-
Matuszewski, B.K.1
Constanzer, M.L.2
Chavez-Eng, C.M.3
-
48
-
-
55549143295
-
Quantitative determination of endogenous compounds in biological samples using chromatographic techniques
-
N.C. van de Merbel,. Quantitative determination of endogenous compounds in biological samples using chromatographic techniques. Trends Anal. Chem. 2008, 27, 924.
-
(2008)
Trends Anal. Chem.
, vol.27
, pp. 924
-
-
Van De Merbel, N.C.1
|