메뉴 건너뛰기




Volumn 23, Issue 10, 2013, Pages 2666-2675

Dual-energy CT lung ventilation/perfusion imaging for diagnosing pulmonary embolism

Author keywords

Dual energy; Lung perfusion; Lung ventilation; Pulmonary embolism; Tomography; X ray computed

Indexed keywords

IOPROMIDE; XENON;

EID: 84884819247     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-013-2907-x     Document Type: Article
Times cited : (69)

References (28)
  • 1
    • 56149087454 scopus 로고    scopus 로고
    • Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: Initial experience
    • 18796658 10.1148/radiol.2492071956
    • Chae EJ, Song JW, Seo JB, Krauss B, Jang YM, Song KS (2008) Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: initial experience. Radiology 249:671-681
    • (2008) Radiology , vol.249 , pp. 671-681
    • Chae, E.J.1    Song, J.W.2    Seo, J.B.3    Krauss, B.4    Jang, Y.M.5    Song, K.S.6
  • 2
    • 64249100198 scopus 로고    scopus 로고
    • Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: A phantom feasibility study
    • 19153744 10.1007/s00330-008-1273-6 1:STN:280:DC%2BD1M3ks1Chsw%3D%3D
    • Brown CL, Hartman RP, Dzyubak OP et al (2009) Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study. Eur Radiol 19:1289-1295
    • (2009) Eur Radiol , vol.19 , pp. 1289-1295
    • Brown, C.L.1    Hartman, R.P.2    Dzyubak, O.P.3
  • 3
    • 35349026173 scopus 로고    scopus 로고
    • Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society
    • 17848685 10.1148/radiol.2452070397
    • Remy-Jardin M, Pistolesi M, Goodman LR et al (2007) Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society. Radiology 245:315-329
    • (2007) Radiology , vol.245 , pp. 315-329
    • Remy-Jardin, M.1    Pistolesi, M.2    Goodman, L.R.3
  • 4
    • 67650075304 scopus 로고    scopus 로고
    • Pulmonary embolism detection with dual-energy CT: Experimental study of dual-source CT in rabbits
    • 19561250 10.1148/radiol.2521081682
    • Zhang LJ, Zhao YE, Wu SY et al (2009) Pulmonary embolism detection with dual-energy CT: experimental study of dual-source CT in rabbits. Radiology 252:61-70
    • (2009) Radiology , vol.252 , pp. 61-70
    • Zhang, L.J.1    Zhao, Y.E.2    Wu, S.Y.3
  • 5
    • 78650566575 scopus 로고    scopus 로고
    • Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography
    • 20680290 10.1007/s00330-010-1903-7
    • Lee CW, Seo JB, Song JW et al (2011) Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography. Eur Radiol 21:54-62
    • (2011) Eur Radiol , vol.21 , pp. 54-62
    • Lee, C.W.1    Seo, J.B.2    Song, J.W.3
  • 6
    • 84856602055 scopus 로고    scopus 로고
    • Evaluation of pulmonary embolism in pediatric patients with nephrotic syndrome with dual energy CT pulmonary angiography
    • 22177283 10.1016/j.acra.2011.11.002
    • Zhang LJ, Wang ZJ, Zhou CS, Lu L, Luo S, Lu GM (2012) Evaluation of pulmonary embolism in pediatric patients with nephrotic syndrome with dual energy CT pulmonary angiography. Acad Radiol 19:341-348
    • (2012) Acad Radiol , vol.19 , pp. 341-348
    • Zhang, L.J.1    Wang, Z.J.2    Zhou, C.S.3    Lu, L.4    Luo, S.5    Lu, G.M.6
  • 7
    • 77955391792 scopus 로고    scopus 로고
    • Dual-energy computed tomography in pulmonary embolism
    • 20551257 10.1259/bjr/16337436
    • Lu GM, Wu SY, Yeh BM, Zhang LJ (2010) Dual-energy computed tomography in pulmonary embolism. Br J Radiol 83:707-718
    • (2010) Br J Radiol , vol.83 , pp. 707-718
    • Lu, G.M.1    Wu, S.Y.2    Yeh, B.M.3    Zhang, L.J.4
  • 8
    • 56349165548 scopus 로고    scopus 로고
    • Dual energy CT for the assessment of lung perfusion - Correlation to scintigraphy
    • 18775618 10.1016/j.ejrad.2008.07.031
    • Thieme SF, Becker CR, Hacker M, Nikolaou K, Reiser MF, Johnson TR (2008) Dual energy CT for the assessment of lung perfusion - correlation to scintigraphy. Eur J Radiol 68:369-374
    • (2008) Eur J Radiol , vol.68 , pp. 369-374
    • Thieme, S.F.1    Becker, C.R.2    Hacker, M.3    Nikolaou, K.4    Reiser, M.F.5    Johnson, T.R.6
  • 9
    • 84855597593 scopus 로고    scopus 로고
    • Dual Energy CT lung perfusion imaging - Correlation with SPECT/CT
    • 10.1016/j.ejrad.2010.11.037
    • Thieme SF, Graute V, Nikolaou K (2012) Dual Energy CT lung perfusion imaging - correlation with SPECT/CT. Eur J Radiol 281:360-365
    • (2012) Eur J Radiol , vol.281 , pp. 360-365
    • Thieme, S.F.1    Graute, V.2    Nikolaou, K.3
  • 10
    • 71449105418 scopus 로고    scopus 로고
    • Detection of pulmonary embolism by dual energy CT: Correlation with perfusion scintigraphy and histopathological findings in rabbits
    • 19657658 10.1007/s00330-009-1518-z
    • Zhang LJ, Chai X, Wu SY (2009) Detection of pulmonary embolism by dual energy CT: correlation with perfusion scintigraphy and histopathological findings in rabbits. Eur Radiol 19:2844-2854
    • (2009) Eur Radiol , vol.19 , pp. 2844-2854
    • Zhang, L.J.1    Chai, X.2    Wu, S.Y.3
  • 11
    • 79953306819 scopus 로고    scopus 로고
    • Pulmonary enhancement imaging with dual energy CT for the detection of pulmonary embolism in a rabbit model: Comparison to perfusion planar scintigraphy, SPECT and SPECT-CT modalities
    • 21474059 10.1016/j.acra.2010.12.012
    • Yang GF, Yang X, Zhang LJ (2011) Pulmonary enhancement imaging with dual energy CT for the detection of pulmonary embolism in a rabbit model: comparison to perfusion planar scintigraphy, SPECT and SPECT-CT modalities. Acad Radiol 18:605-614
    • (2011) Acad Radiol , vol.18 , pp. 605-614
    • Yang, G.F.1    Yang, X.2    Zhang, L.J.3
  • 12
    • 49049090606 scopus 로고    scopus 로고
    • Xenon ventilation CT with a dual-energy technique of dual-source CT: Initial experience
    • 18641254 10.1148/radiol.2482071482
    • Chae EJ, Seo JB, Goo HW et al (2008) Xenon ventilation CT with a dual-energy technique of dual-source CT: initial experience. Radiology 248:615-624
    • (2008) Radiology , vol.248 , pp. 615-624
    • Chae, E.J.1    Seo, J.B.2    Goo, H.W.3
  • 13
    • 77956114536 scopus 로고    scopus 로고
    • Chronic obstructive pulmonary disease: Quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique
    • 20651060 10.1148/radiol.10091502
    • Park EA, Goo JM, Park SJ (2010) Chronic obstructive pulmonary disease: quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique. Radiology 256:985-997
    • (2010) Radiology , vol.256 , pp. 985-997
    • Park, E.A.1    Goo, J.M.2    Park, S.J.3
  • 14
    • 77952470631 scopus 로고    scopus 로고
    • Xenon ventilation imaging using dual-energy computed tomography in asthmatics: Initial experience
    • 20404734
    • Chae EJ, Seo JB, Lee J (2010) Xenon ventilation imaging using dual-energy computed tomography in asthmatics: initial experience. Invest Radiol 45:354-361
    • (2010) Invest Radiol , vol.45 , pp. 354-361
    • Chae, E.J.1    Seo, J.B.2    Lee, J.3
  • 15
    • 77953532930 scopus 로고    scopus 로고
    • Dual-energy CT: Clinical applications in various pulmonary diseases
    • 20462988 10.1148/rg.303095101
    • Kang MJ, Park CM, Lee CH, Goo JM, Lee HJ (2010) Dual-energy CT: clinical applications in various pulmonary diseases. Radiographics 30:685-698
    • (2010) Radiographics , vol.30 , pp. 685-698
    • Kang, M.J.1    Park, C.M.2    Lee, C.H.3    Goo, J.M.4    Lee, H.J.5
  • 16
    • 78650303334 scopus 로고    scopus 로고
    • Pulmonary ventilation and perfusion imaging with dual-energy CT
    • 20571800 10.1007/s00330-010-1866-8
    • Thieme SF, Hoegl S, Nikolaou K (2010) Pulmonary ventilation and perfusion imaging with dual-energy CT. Eur Radiol 20:2882-2889
    • (2010) Eur Radiol , vol.20 , pp. 2882-2889
    • Thieme, S.F.1    Hoegl, S.2    Nikolaou, K.3
  • 17
    • 84855182285 scopus 로고    scopus 로고
    • Expert opinion: Dual energy CT: Most and least relevant cardiopulmonary imaging applications
    • 22189244 10.1097/RTI.0b013e31823e2732
    • Boiselle PM, Nikolaou K, Schoepf UJ, Seo JB (2012) Expert opinion: Dual energy CT: most and least relevant cardiopulmonary imaging applications. J Thorac Imaging 27:6
    • (2012) J Thorac Imaging , vol.27 , pp. 6
    • Boiselle, P.M.1    Nikolaou, K.2    Schoepf, U.J.3    Seo, J.B.4
  • 18
    • 84869164450 scopus 로고    scopus 로고
    • Dual energy computed tomography demonstrated lung ventilation/perfusion mismatch in a 19-year-old patient with pulmonary embolism
    • 23147771 10.1161/CIRCULATIONAHA.112.130849
    • Zhang LJ, Zhou CS, Lu GM (2012) Dual energy computed tomography demonstrated lung ventilation/perfusion mismatch in a 19-year-old patient with pulmonary embolism. Circulation 126:2441-2443
    • (2012) Circulation , vol.126 , pp. 2441-2443
    • Zhang, L.J.1    Zhou, C.S.2    Lu, G.M.3
  • 20
    • 77952469475 scopus 로고    scopus 로고
    • Enhanced visualization of lung vessels for diagnosis of pulmonary embolism using dual energy CT angiography
    • 20421798
    • Krissak R, Henzler T, Reichert M, Krauss B, Schoenberg SO, Fink C (2010) Enhanced visualization of lung vessels for diagnosis of pulmonary embolism using dual energy CT angiography. Invest Radiol 45:341-346
    • (2010) Invest Radiol , vol.45 , pp. 341-346
    • Krissak, R.1    Henzler, T.2    Reichert, M.3    Krauss, B.4    Schoenberg, S.O.5    Fink, C.6
  • 22
    • 60349123970 scopus 로고    scopus 로고
    • Ventilation/perfusion lung scintigraphy: What is still needed? A review considering technetium-99m-labeled macro-aggregates of albumin
    • 19205833 10.1007/s12149-008-0187-3
    • Zöphel K, Bacher-Stier C, Pinkert J, Kropp J (2009) Ventilation/perfusion lung scintigraphy: what is still needed? A review considering technetium-99m-labeled macro-aggregates of albumin. Ann Nucl Med 23:1-16
    • (2009) Ann Nucl Med , vol.23 , pp. 1-16
    • Zöphel, K.1    Bacher-Stier, C.2    Pinkert, J.3    Kropp, J.4
  • 23
    • 56749133140 scopus 로고    scopus 로고
    • Reinventing ventilation/perfusion lung scanning with SPECT
    • 18987521 10.1097/MNM.0b013e328315efa1
    • Roach PJ, Bailey DL, Schembri GP (2008) Reinventing ventilation/perfusion lung scanning with SPECT. Nucl Med Commun 29:1023-1025
    • (2008) Nucl Med Commun , vol.29 , pp. 1023-1025
    • Roach, P.J.1    Bailey, D.L.2    Schembri, G.P.3
  • 24
    • 84856728150 scopus 로고    scopus 로고
    • Diagnostic accuracy of single-photon emission tomography ventilation/perfusion lung scan in the diagnosis of pulmonary embolism
    • 21852295 10.1378/chest.11-0090
    • Le Duc-Pennec A, Le Roux PY, Cornily JC et al (2012) Diagnostic accuracy of single-photon emission tomography ventilation/perfusion lung scan in the diagnosis of pulmonary embolism. Chest 141:381-387
    • (2012) Chest , vol.141 , pp. 381-387
    • Le Duc-Pennec, A.1    Le Roux, P.Y.2    Cornily, J.C.3
  • 25
    • 73149111747 scopus 로고    scopus 로고
    • A comparison of single-photon emission CT lung scintigraphy and CT pulmonary angiography for the diagnosis of pulmonary embolism
    • 19525358 10.1378/chest.09-0361
    • Miles S, Rogers KM, Thomas P et al (2009) A comparison of single-photon emission CT lung scintigraphy and CT pulmonary angiography for the diagnosis of pulmonary embolism. Chest 136:1546-1553
    • (2009) Chest , vol.136 , pp. 1546-1553
    • Miles, S.1    Rogers, K.M.2    Thomas, P.3
  • 26
    • 55349095807 scopus 로고    scopus 로고
    • Lung perfusion with dual-energy multidetector-row CT (MDCT): Feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients
    • 19000866 10.1016/j.acra.2008.05.018
    • Pontana F, Faivre JB, Remy-Jardin M (2008) Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol 15:1494-1504
    • (2008) Acad Radiol , vol.15 , pp. 1494-1504
    • Pontana, F.1    Faivre, J.B.2    Remy-Jardin, M.3
  • 27
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • 17635892 10.1001/jama.298.3.317 1:CAS:528:DC%2BD2sXotVarsbw%3D
    • Einstein AJ, Henzlova MJ, Rajagopalan S (2007) Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298:317-323
    • (2007) JAMA , vol.298 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 28
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • 18046031 10.1056/NEJMra072149 1:CAS:528:DC%2BD2sXhsVSlurfF
    • Brenner DJ, Hall EJ (2007) Computed tomography - an increasing source of radiation exposure. N Engl J Med 357:2277-2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.