메뉴 건너뛰기




Volumn 21, Issue 1, 2011, Pages 54-62

Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography

Author keywords

Computer aided diagnosis; CT; Diagnosis; Dual energy CT; Pulmonary embolism

Indexed keywords

ARTICLE; CLINICAL EVALUATION; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER AIDED DETECTION; DIAGNOSTIC PROCEDURE; DUAL ENERGY SOFTWARE; HUMAN; LUNG EMBOLISM; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; PULMONARY ARTERY; SENSITIVITY AND SPECIFICITY;

EID: 78650566575     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-010-1903-7     Document Type: Article
Times cited : (77)

References (23)
  • 1
    • 0034023924 scopus 로고    scopus 로고
    • Incidence of venous thromboembolism: A community-based study in Western France. EPI-GETBP Study Group. Groupe d'Etude de la Thrombose de Bretagne Occidentale
    • 1:CAS:528:DC%2BD3cXjsl2hsLo%3D 10823257
    • E Oger 2000 Incidence of venous thromboembolism: a community-based study in Western France. EPI-GETBP Study Group. Groupe d'Etude de la Thrombose de Bretagne Occidentale Thromb Haemost 83 657 660 1:CAS:528:DC%2BD3cXjsl2hsLo%3D 10823257
    • (2000) Thromb Haemost , vol.83 , pp. 657-660
    • Oger, E.1
  • 2
    • 39849091192 scopus 로고    scopus 로고
    • Increased diagnosis of pulmonary embolism without a corresponding decline in mortality during the CT era
    • 1:STN:280:DC%2BD1c7ms1yjsg%3D%3D 10.1016/j.crad.2007.10.004 18325357
    • AJ Burge KD Freeman PJ Klapper LB Haramati 2008 Increased diagnosis of pulmonary embolism without a corresponding decline in mortality during the CT era Clin Radiol 63 381 386 1:STN:280:DC%2BD1c7ms1yjsg%3D%3D 10.1016/j.crad.2007. 10.004 18325357
    • (2008) Clin Radiol , vol.63 , pp. 381-386
    • Burge, A.J.1    Freeman, K.D.2    Klapper, P.J.3    Haramati, L.B.4
  • 3
    • 0030039489 scopus 로고    scopus 로고
    • Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan
    • 10.1136/thx.51.1.23 8658363
    • AB van Rossum FE Treurniet GJ Kieft SJ Smith R Schepers-Bok 1996 Role of spiral volumetric computed tomographic scanning in the assessment of patients with clinical suspicion of pulmonary embolism and an abnormal ventilation/perfusion lung scan Thorax 51 23 28 10.1136/thx.51.1.23 8658363
    • (1996) Thorax , vol.51 , pp. 23-28
    • Van Rossum, A.B.1    Treurniet, F.E.2    Kieft, G.J.3    Smith, S.J.4    Schepers-Bok, R.5
  • 4
    • 0029831577 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with spiral CT: Comparison with pulmonary angiography and scintigraphy
    • 1:STN:280:DyaK28zkslygug%3D%3D 8756918
    • M Remy-Jardin J Remy F Deschildre, et al. 1996 Diagnosis of pulmonary embolism with spiral CT: comparison with pulmonary angiography and scintigraphy Radiology 200 699 706 1:STN:280:DyaK28zkslygug%3D%3D 8756918
    • (1996) Radiology , vol.200 , pp. 699-706
    • Remy-Jardin, M.1    Remy, J.2    Deschildre, F.3
  • 5
    • 0030711577 scopus 로고    scopus 로고
    • Pulmonary embolism: Prospective comparison of spiral CT with ventilation-perfusion scintigraphy
    • 1:STN:280:DyaK1c%2FhvFCnsg%3D%3D 9356627
    • JR Mayo M Remy-Jardin NL Muller, et al. 1997 Pulmonary embolism: prospective comparison of spiral CT with ventilation-perfusion scintigraphy Radiology 205 2 447 452 1:STN:280:DyaK1c%2FhvFCnsg%3D%3D 9356627
    • (1997) Radiology , vol.205 , Issue.2 , pp. 447-452
    • Mayo, J.R.1    Remy-Jardin, M.2    Muller, N.L.3
  • 6
    • 0029026454 scopus 로고
    • Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: Helical CT versus angiography
    • 1:STN:280:DyaK2M3nsVCqtQ%3D%3D 7754875
    • LR Goodman JJ Curtin MW Mewissen, et al. 1995 Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT versus angiography AJR Am J Roentgenol 164 1369 1374 1:STN:280:DyaK2M3nsVCqtQ%3D%3D 7754875
    • (1995) AJR Am J Roentgenol , vol.164 , pp. 1369-1374
    • Goodman, L.R.1    Curtin, J.J.2    Mewissen, M.W.3
  • 7
    • 0031878546 scopus 로고    scopus 로고
    • Pulmonary embolism: Diagnosis with spiral CT and ventilation-perfusion scanning-correlation with pulmonary angiographic results or clinical outcome
    • 1:STN:280:DyaK1czhtVOrsA%3D%3D 9646814
    • K Garg CH Welsh AJ Feyerabend, et al. 1998 Pulmonary embolism: diagnosis with spiral CT and ventilation-perfusion scanning-correlation with pulmonary angiographic results or clinical outcome Radiology 208 201 208 1:STN:280:DyaK1czhtVOrsA%3D%3D 9646814
    • (1998) Radiology , vol.208 , pp. 201-208
    • Garg, K.1    Welsh, C.H.2    Feyerabend, A.J.3
  • 8
    • 22844446155 scopus 로고    scopus 로고
    • CT imaging in acute pulmonary embolism: Diagnostic strategies
    • 10.1007/s00330-005-2643-y 15662491
    • JE Wildberger AH Mahnken M Das A Kuttner M Lell RW Gunther 2005 CT imaging in acute pulmonary embolism: diagnostic strategies Eur Radiol 15 919 929 10.1007/s00330-005-2643-y 15662491
    • (2005) Eur Radiol , vol.15 , pp. 919-929
    • Wildberger, J.E.1    Mahnken, A.H.2    Das, M.3    Kuttner, A.4    Lell, M.5    Gunther, R.W.6
  • 9
    • 33947694585 scopus 로고    scopus 로고
    • Diagnostic pathways in acute pulmonary embolism: Recommendations of the PIOPED II investigators
    • 10.1016/j.amjmed.2006.05.060 17145249
    • PD Stein PK Woodard JG Weg, et al. 2006 Diagnostic pathways in acute pulmonary embolism: recommendations of the PIOPED II investigators Am J Med 119 1048 1055 10.1016/j.amjmed.2006.05.060 17145249
    • (2006) Am J Med , vol.119 , pp. 1048-1055
    • Stein, P.D.1    Woodard, P.K.2    Weg, J.G.3
  • 10
    • 33744503127 scopus 로고    scopus 로고
    • Multidetector computed tomography for acute pulmonary embolism
    • 1:CAS:528:DC%2BD28XmtVykt78%3D 10.1056/NEJMoa052367 16738268
    • PD Stein SE Fowler LR Goodman, et al. 2006 Multidetector computed tomography for acute pulmonary embolism N Engl J Med 354 2317 2327 1:CAS:528:DC%2BD28XmtVykt78%3D 10.1056/NEJMoa052367 16738268
    • (2006) N Engl J Med , vol.354 , pp. 2317-2327
    • Stein, P.D.1    Fowler, S.E.2    Goodman, L.R.3
  • 11
    • 33644977678 scopus 로고    scopus 로고
    • Diagnosis and management of subsegmental pulmonary embolism
    • 10.1111/j.1538-7836.2006.01819.x 16634736
    • G Le Gal M Righini F Parent M van Strijen F Couturaud 2006 Diagnosis and management of subsegmental pulmonary embolism J Thromb Haemost 4 724 731 10.1111/j.1538-7836.2006.01819.x 16634736
    • (2006) J Thromb Haemost , vol.4 , pp. 724-731
    • Le Gal, G.1    Righini, M.2    Parent, F.3    Van Strijen, M.4    Couturaud, F.5
  • 12
    • 33947182969 scopus 로고    scopus 로고
    • Multidetector computed tomography (MDCT) in the diagnosis of pulmonary embolism: Interobserver agreement among radiologists with varied levels of experience
    • 1:STN:280:DC%2BD2s7ltlKitQ%3D%3D 10.1080/02841850601100859 17354136
    • W Ghanima BE Nielssen LO Holmen A Witwit A Al-Ashtari PM Sandset 2007 Multidetector computed tomography (MDCT) in the diagnosis of pulmonary embolism: interobserver agreement among radiologists with varied levels of experience Acta Radiol 48 165 170 1:STN:280:DC%2BD2s7ltlKitQ%3D%3D 10.1080/ 02841850601100859 17354136
    • (2007) Acta Radiol , vol.48 , pp. 165-170
    • Ghanima, W.1    Nielssen, B.E.2    Holmen, L.O.3    Witwit, A.4    Al-Ashtari, A.5    Sandset, P.M.6
  • 13
    • 26044460979 scopus 로고    scopus 로고
    • Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism
    • 1:STN:280:DC%2BD2MrmvF2ruw%3D%3D 10.1007/s00330-005-2844-4 16021452
    • S Brunot O Corneloup V Latrabe M Montaudon F Laurent 2005 Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism Eur Radiol 15 2057 2063 1:STN:280: DC%2BD2MrmvF2ruw%3D%3D 10.1007/s00330-005-2844-4 16021452
    • (2005) Eur Radiol , vol.15 , pp. 2057-2063
    • Brunot, S.1    Corneloup, O.2    Latrabe, V.3    Montaudon, M.4    Laurent, F.5
  • 14
    • 36649003540 scopus 로고    scopus 로고
    • Pulmonary embolism: Computer-aided detection at multidetector row spiral computed tomography
    • 10.1097/RTI.0b013e31815842a9 18043385
    • UJ Schoepf AC Schneider M Das SA Wood JI Cheema P Costello 2007 Pulmonary embolism: computer-aided detection at multidetector row spiral computed tomography J Thorac Imaging 22 319 323 10.1097/RTI.0b013e31815842a9 18043385
    • (2007) J Thorac Imaging , vol.22 , pp. 319-323
    • Schoepf, U.J.1    Schneider, A.C.2    Das, M.3    Wood, S.A.4    Cheema, J.I.5    Costello, P.6
  • 15
    • 36649015219 scopus 로고    scopus 로고
    • Computer-aided detection of pulmonary embolism on CT angiography: Initial experience
    • 10.1097/RTI.0b013e31815b89ca 18043386
    • ZV Maizlin PM Vos MC Godoy PL Cooperberg 2007 Computer-aided detection of pulmonary embolism on CT angiography: initial experience J Thorac Imaging 22 324 329 10.1097/RTI.0b013e31815b89ca 18043386
    • (2007) J Thorac Imaging , vol.22 , pp. 324-329
    • Maizlin, Z.V.1    Vos, P.M.2    Godoy, M.C.3    Cooperberg, P.L.4
  • 16
    • 34250221160 scopus 로고    scopus 로고
    • Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism
    • 10.1016/j.acra.2007.02.007 17502254
    • S Buhmann P Herzog J Liang, et al. 2007 Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism Acad Radiol 14 651 658 10.1016/j.acra.2007.02.007 17502254
    • (2007) Acad Radiol , vol.14 , pp. 651-658
    • Buhmann, S.1    Herzog, P.2    Liang, J.3
  • 17
    • 45849092871 scopus 로고    scopus 로고
    • Computer-aided detection of pulmonary embolism: Influence on radiologists' detection performance with respect to vessel segments
    • 10.1007/s00330-008-0889-x 18292998
    • M Das G Muhlenbruch A Helm, et al. 2008 Computer-aided detection of pulmonary embolism: Influence on radiologists' detection performance with respect to vessel segments Eur Radiol 18 1350 1355 10.1007/s00330-008-0889-x 18292998
    • (2008) Eur Radiol , vol.18 , pp. 1350-1355
    • Das, M.1    Muhlenbruch, G.2    Helm, A.3
  • 18
    • 39049099930 scopus 로고    scopus 로고
    • Computer-assisted detection of pulmonary embolism: Performance evaluation in consensus with experienced and inexperienced chest radiologists
    • 10.1007/s00330-007-0770-3 17901958
    • C Engelke S Schmidt A Bakai F Auer K Marten 2008 Computer-assisted detection of pulmonary embolism: performance evaluation in consensus with experienced and inexperienced chest radiologists Eur Radiol 18 298 307 10.1007/s00330-007-0770-3 17901958
    • (2008) Eur Radiol , vol.18 , pp. 298-307
    • Engelke, C.1    Schmidt, S.2    Bakai, A.3    Auer, F.4    Marten, K.5
  • 19
    • 55349095807 scopus 로고    scopus 로고
    • Lung perfusion with dual-energy multidetector-row CT (MDCT): Feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients
    • 10.1016/j.acra.2008.05.018 19000866
    • F Pontana JB Faivre M Remy-Jardin, et al. 2008 Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients Acad Radiol 15 1494 1504 10.1016/j.acra.2008.05.018 19000866
    • (2008) Acad Radiol , vol.15 , pp. 1494-1504
    • Pontana, F.1    Faivre, J.B.2    Remy-Jardin, M.3
  • 20
    • 67650306387 scopus 로고    scopus 로고
    • Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma
    • 10.2214/AJR.08.1653 19542406
    • SF Thieme TR Johnson C Lee, et al. 2009 Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma AJR Am J Roentgenol 193 144 149 10.2214/AJR.08.1653 19542406
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 144-149
    • Thieme, S.F.1    Johnson, T.R.2    Lee, C.3
  • 21
    • 34548403882 scopus 로고    scopus 로고
    • Computer aided detection of pulmonary embolism with tobogganing and mutiple instance classification in CT pulmonary angiography
    • 10.1007/978-3-540-73273-0-52 17633735
    • J Liang J Bi 2007 Computer aided detection of pulmonary embolism with tobogganing and mutiple instance classification in CT pulmonary angiography Inf Process Med Imaging 20 630 641 10.1007/978-3-540-73273-0-52 17633735
    • (2007) Inf Process Med Imaging , vol.20 , pp. 630-641
    • Liang, J.1    Bi, J.2
  • 22
    • 34248673159 scopus 로고    scopus 로고
    • Material differentiation by dual energy CT: Initial experience
    • 10.1007/s00330-006-0517-6 17151859
    • TR Johnson B Krauss M Sedlmair, et al. 2007 Material differentiation by dual energy CT: initial experience Eur Radiol 17 1510 1517 10.1007/s00330-006- 0517-6 17151859
    • (2007) Eur Radiol , vol.17 , pp. 1510-1517
    • Johnson, T.R.1    Krauss, B.2    Sedlmair, M.3
  • 23
    • 77749277564 scopus 로고    scopus 로고
    • Dual-energy CT for assessment of the severity of acute pulmonary embolism: Pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio
    • Chae EJ, Seo JB, Jang YM, et al Dual-energy CT for assessment of the severity of acute pulmonary embolism: pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio. AJR Am J Roentgenol 194:604-610
    • AJR Am J Roentgenol , vol.194 , pp. 604-610
    • Chae, E.J.1    Seo, J.B.2    Jang, Y.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.