메뉴 건너뛰기




Volumn 190, Issue , 2014, Pages 243-248

Label-free CRP detection using optical biosensor with one-step immobilization of antibody on nitrocellulose membrane

Author keywords

C reactive protein; Label free; Metal clad waveguide; Nitrocellulose; Optical biosensor

Indexed keywords

ADDITIONAL TREATMENT; C-REACTIVE PROTEINS; CONCENTRATION RANGES; LABEL FREE; LABEL-FREE OPTICAL BIOSENSORS; METAL-CLAD WAVEGUIDES; NITROCELLULOSE MEMBRANES; OPTICAL BIO-SENSORS;

EID: 84884561941     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.08.078     Document Type: Article
Times cited : (29)

References (13)
  • 8
    • 40749110305 scopus 로고    scopus 로고
    • A single layer nitrocellulose substrate for fabricating protein chips
    • L.T. Yin, C.Y. Hu, and C.H. Chang A single layer nitrocellulose substrate for fabricating protein chips Sens. Actuators B: Chem. 130 2008 374 378
    • (2008) Sens. Actuators B: Chem. , vol.130 , pp. 374-378
    • Yin, L.T.1    Hu, C.Y.2    Chang, C.H.3
  • 9
    • 0030956673 scopus 로고    scopus 로고
    • Inflammation, aspirin, and the risk of cardiovascular disease in apparently healthy men
    • DOI 10.1056/NEJM199704033361401
    • P.M. Ridker, M. Cushman, M.J. Stampfer, R.P. Tracy, and C.H. Hennekens Inflammation, aspirin, and risk of cardiovascular disease in apparently healthy men N. Engl. J. Med. 336 1997 973 979 (Pubitemid 27152782)
    • (1997) New England Journal of Medicine , vol.336 , Issue.14 , pp. 973-979
    • Ridker, P.M.1    Cushman, M.2    Stampfer, M.J.3    Tracy, R.P.4    Hennekens, C.H.5
  • 10
    • 0032566401 scopus 로고    scopus 로고
    • Prospective study of C-reactive protein and the risk of future cardiovascular events among apparently healthy women
    • P.M. Ridker, J.E. Buring, J. Shih, M. Matias, and C.H. Hennekens Prospective study of C-reactive protein and the risk of future cardiovascular events among apparently healthy women Circulation 98 1998 731 733 (Pubitemid 28391836)
    • (1998) Circulation , vol.98 , Issue.8 , pp. 731-733
    • Ridker, P.M.1    Buring, J.E.2    Shih, J.3    Matias, M.4    Hennekens, C.H.5
  • 11
    • 36449009386 scopus 로고
    • Molecular recognition at self-assembled monolayers: Optimization of surface functionalization
    • J. Spinkle, M. Liley, F.J. Schmitt, H.J. Guder, and L. Angermaier Molecular recognition at self-assembled monolayers: optimization of surface functionalization J. Chem. Phys. 99 1993 7012 7019
    • (1993) J. Chem. Phys. , vol.99 , pp. 7012-7019
    • Spinkle, J.1    Liley, M.2    Schmitt, F.J.3    Guder, H.J.4    Angermaier, L.5
  • 12
    • 14644415474 scopus 로고    scopus 로고
    • Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers
    • DOI 10.1016/j.bios.2004.09.023, PII S0956566304004282
    • K.W. Wee, G.Y. Kang, J. Park, J.Y. Kang, D.S. Yoon, J.H. Park, and T.S. Kim Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers Biosens. Bioelectron. 20 2005 1932 1938 (Pubitemid 40312087)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.10 SPEC. ISSUE. , pp. 1932-1938
    • Wee, K.W.1    Kang, G.Y.2    Park, J.3    Kang, J.Y.4    Yoon, D.S.5    Park, J.H.6    Kim, T.S.7
  • 13
    • 31044439705 scopus 로고    scopus 로고
    • Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance biosensing
    • DOI 10.1016/j.bios.2005.11.001, PII S0956566305003520
    • W.P. Hu, H.-Y. Hsu, A. Chiou, K.Y. Tseng, H.-Y. Lin, G.L. Chang, and S.-J. Chen Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance biosensing Biosens. Bioelectron. 21 2006 1631 1637 (Pubitemid 43122031)
    • (2006) Biosensors and Bioelectronics , vol.21 , Issue.8 , pp. 1631-1637
    • Hu, W.P.1    Hsu, H.-Y.2    Chiou, A.3    Tseng, K.Y.4    Lin, H.-Y.5    Chang, G.L.6    Chen, S.-J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.