Volumn 6, Issue 3, 2013, Pages 284-291

Transcatheter aortic valve implantation for patients with severe bicuspid aortic valve stenosis

Author keywords

Aortic stenosis; Bicuspid aortic valve; Computed tomography; Echocardiography; Transcatheter aortic valve implantation

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; HEPARIN;

EID: 84884471245     PISSN: 19417640     EISSN: 19417632     Source Type: Journal    
DOI: 10.1161/CIRCINTERVENTIONS.112.000084     Document Type: Article
Times cited : (149)

References (18)
  • 1
    • 0014820336 scopus 로고
    • The congenitally bicuspid aortic valve. A study of 85 autopsy cases
    • Roberts WC. The congenitally bicuspid aortic valve. A study of 85 autopsy cases. Am J Cardiol. 1970;26:72-83.
    • (1970) Am J Cardiol , vol.26 , pp. 72-83
    • Roberts, W.C.1
  • 2
    • 23944467963 scopus 로고    scopus 로고
    • Frequency of bicuspid aortic valve in young male conscripts by echocardiogram
    • Nistri S, Basso C, Marzari C, Mormino P, Thiene G. Frequency of bicuspid aortic valve in young male conscripts by echocardiogram. Am J Cardiol. 2005;96:718-721.
    • (2005) Am J Cardiol , vol.96 , pp. 718-721
    • Nistri, S.1    Basso, C.2    Marzari, C.3    Mormino, P.4    Thiene, G.5
  • 3
    • 14044262240 scopus 로고    scopus 로고
    • Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation
    • Roberts WC, Ko JM. Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation. Circulation. 2005;111:920-925.
    • (2005) Circulation , vol.111 , pp. 920-925
    • Roberts, W.C.1    Ko, J.M.2
  • 10
    • 29244432482 scopus 로고    scopus 로고
    • Recommendations for chamber quantification: A report from the american society of echocardiography's guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the european association of echocardiography, a branch of the european society of cardiology
    • Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ. Recommendations for chamber quantification: A report from the American society of echocardiography's guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the European association of echocardiography, a branch of the European society of cardiology. J Am Soc Echocardiogr. 2005;18:1440-1463.
    • (2005) J Am Soc Echocardiogr. , vol.18 , pp. 1440-1463
    • Lang, R.M.1    Bierig, M.2    Devereux, R.B.3    Flachskampf, F.A.4    Foster, E.5    Pellikka, P.A.6    Picard, M.H.7    Roman, M.J.8    Seward, J.9    Shanewise, J.S.10    Solomon, S.D.11    Spencer, K.T.12    Sutton, M.S.13    Stewart, W.J.14
  • 13
    • 78649323412 scopus 로고    scopus 로고
    • Assessment of aortic annulus dimensions for edwards sapien transapical heart valve implantation by computed tomography: Calculating average diameter using a virtual ring method
    • Blanke P, Siepe M, Reinöhl J, Zehender M, Beyersdorf F, Schlensak C, Langer M, Pache G. Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method. Eur J Cardiothorac Surg. 2010;38:750-758.
    • (2010) Eur J Cardiothorac Surg , vol.38 , pp. 750-758
    • Blanke, P.1    Siepe, M.2    Reinöhl, J.3    Zehender, M.4    Beyersdorf, F.5    Schlensak, C.6    Langer, M.7    Pache, G.8
  • 15
    • 34247463401 scopus 로고    scopus 로고
    • A classification system for the bicuspid aortic valve from 304 surgical specimens
    • Sievers HH, Schmidtke C. A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg. 2007;133:1226-1233.
    • (2007) J Thorac Cardiovasc Surg. , vol.133 , pp. 1226-1233
    • Sievers, H.H.1    Schmidtke, C.2
  • 17
    • 77958585763 scopus 로고    scopus 로고
    • Diagnostic value of cardiac ct in the evaluation of bicuspid aortic stenosis: Comparison with echocardiography and operative findings
    • Tanaka R, Yoshioka K, Niinuma H, Ohsawa S, Okabayashi H, Ehara S. Diagnostic value of cardiac CT in the evaluation of bicuspid aortic stenosis: comparison with echocardiography and operative findings. AJR Am J Roentgenol. 2010;195:895-899.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 895-899
    • Tanaka, R.1    Yoshioka, K.2    Niinuma, H.3    Ohsawa, S.4    Okabayashi, H.5    Ehara, S.6
  • 18
    • 0032894771 scopus 로고    scopus 로고
    • Congenitally bicuspid aortic valves: A surgical pathology study of 542 cases (1991 through 1996) and a literature review of 2,715 additional cases
    • Sabet HY, Edwards WD, Tazelaar HD, Daly RC. Congenitally bicuspid aortic valves: a surgical pathology study of 542 cases (1991 through 1996) and a literature review of 2,715 additional cases. Mayo Clin Proc. 1999;74:14-26.
    • (1999) Mayo Clin Proc , vol.74 , pp. 14-26
    • Sabet, H.Y.1    Edwards, W.D.2    Tazelaar, H.D.3    Daly, R.C.4