메뉴 건너뛰기




Volumn 15, Issue 5, 2013, Pages 811-820

Subcutaneous blood pressure monitoring with an implantable optical sensor

Author keywords

Blood pressure monitoring; Medical implant; Minimally invasive; Optical sensor; Photoplethysmography; Pulse transit time

Indexed keywords

BLOOD PRESSURE MONITORS; BLOOD-PRESSURE MONITORING; MEDICAL IMPLANTS; MINIMALLY INVASIVE; MINIMALLY-INVASIVE TECHNIQUE; PHOTOPLETHYSMOGRAPHIC SIGNALS; PULSE TRANSIT TIME; SYSTOLIC BLOOD PRESSURE;

EID: 84884355119     PISSN: 13872176     EISSN: 15728781     Source Type: Journal    
DOI: 10.1007/s10544-013-9768-6     Document Type: Article
Times cited : (27)

References (20)
  • 2
    • 0141610987 scopus 로고    scopus 로고
    • Mobile monitoring with wearable photoplethysmographic biosensors
    • 10.1109/MEMB.2003.1213624 10.1109/MEMB.2003.1213624
    • H. Asada, P. Shaltis, A. Reisner, S. Rhee, R. Hutchinson, Mobile monitoring with wearable photoplethysmographic biosensors. Eng. Med. Biol. Mag. IEEE 22(3), 28-40 (2003). doi: 10.1109/MEMB.2003.1213624
    • (2003) Eng. Med. Biol. Mag. IEEE , vol.22 , Issue.3 , pp. 28-40
    • Asada, H.1    Shaltis, P.2    Reisner, A.3    Rhee, S.4    Hutchinson, R.5
  • 3
    • 85007834134 scopus 로고
    • The static elastic properties of the arterial wall
    • D. Bergel, The static elastic properties of the arterial wall. J. Physiol. 445, 156-3 (1961)
    • (1961) J. Physiol. , vol.445 , pp. 156-163
    • Bergel, D.1
  • 4
    • 0032898657 scopus 로고    scopus 로고
    • Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
    • J. Blacher, R. Asmar, S. Djane, G. London, M. Safar, Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients. Hypertens. - J. Am. Heart Assoc. 33, 1111-1117 (1999)
    • (1999) Hypertens. - J. Am. Heart Assoc. , vol.33 , pp. 1111-1117
    • Blacher, J.1    Asmar, R.2    Djane, S.3    London, G.4    Safar, M.5
  • 11
    • 56549100716 scopus 로고    scopus 로고
    • ed. by Y. Zhang. Cuffless and Noninvasive Estimation Of Blood Pressure Based On A Wavelet Transform Approach doi: 10.1109/APBME.2003.1302627
    • C. Lee, C. Lee, Y. Zhang, in Proceedings IEEE EMBS Asian-Pacific Conference on Biomedical Engineering, ed. by Y. Zhang. Cuffless and Noninvasive Estimation Of Blood Pressure Based On A Wavelet Transform Approach, 148-149 (2003). doi: 10.1109/APBME.2003.1302627
    • (2003) Proceedings IEEE EMBS Asian-Pacific Conference on Biomedical Engineering , pp. 148-149
    • Lee, C.1    Lee, C.2    Zhang, Y.3
  • 12
    • 33746750929 scopus 로고    scopus 로고
    • Contour analysis of the photoplethysmographic pulse measured at the finger
    • 10.1097/01.hjh.0000239277.05068.87
    • S.C. Millasseaua, J.M. Rittera, K. Takazawab, P.J. Chowienczyka, Contour analysis of the photoplethysmographic pulse measured at the finger. J. Hypertens. 24, 1449-1456 (2006)
    • (2006) J. Hypertens. , vol.24 , pp. 1449-1456
    • Millasseaua, S.C.1    Rittera, J.M.2    Takazawab, K.3    Chowienczyka, P.J.4
  • 14
    • 0000147387 scopus 로고
    • The effect of blood pressure alteration on the pulse wave velocity
    • 10.1136/hrt.26.2.261
    • E. Nye, The effect of blood pressure alteration on the pulse wave velocity. Br. Heart J. 26, 261-265 (1964)
    • (1964) Br. Heart J. , vol.26 , pp. 261-265
    • Nye, E.1
  • 19
    • 57349138850 scopus 로고    scopus 로고
    • Hemodynamic sensing using subcutaneous photoplethysmography
    • 10.1152/ajpheart.00574.2008
    • R. Turcott, T. Pavek, Hemodynamic sensing using subcutaneous photoplethysmography. Am. J. Physiol. - Heart and Circ. Physiol. 295-6, 2560-2572 (2008)
    • (2008) Am. J. Physiol. - Heart and Circ. Physiol. , vol.295-296 , pp. 2560-2572
    • Turcott, R.1    Pavek, T.2
  • 20
    • 0032408206 scopus 로고    scopus 로고
    • Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
    • 10.1097/00004872-199816121-00033
    • S.I.B.F. Wilkinson, I.M. Jansen, J.C. Spratt, G.D. Murray, J.R. Cockcroft, D. Webb, Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis. J. Hypertens. 16, 2079-2084 (1998)
    • (1998) J. Hypertens. , vol.16 , pp. 2079-2084
    • Wilkinson, S.1    Jansen, I.M.2    Spratt, J.C.3    Murray, G.D.4    Cockcroft, J.R.5    Webb, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.