메뉴 건너뛰기




Volumn 28, Issue 5, 2013, Pages 1241-1247

Custom-made, selective laser sintering (SLS) blade implants as a non-conventional solution for the prosthetic rehabilitation of extremely atrophied posterior mandible

Author keywords

Blade implants; Computer aided design computer aided manufacturing (CAD CAM); Custom made; Selective laser sintering (SLS)

Indexed keywords

TITANIUM;

EID: 84884289088     PISSN: 02688921     EISSN: 1435604X     Source Type: Journal    
DOI: 10.1007/s10103-012-1205-1     Document Type: Article
Times cited : (54)

References (30)
  • 1
    • 84866491480 scopus 로고    scopus 로고
    • R) for the rehabilitation of horizontally deficient edentulous ridges: Prospective study on 18 consecutive patients
    • doi: 10.1111/j.1600-0501.2011.02296.x
    • R) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients. Clin Oral Implants Res. doi: 10.1111/j.1600-0501.2011.02296.x
    • (2011) Clin Oral Implants Res.
    • Chiapasco, M.1    Casentini, P.2    Zaniboni, M.3    Corsi, E.4    Anello, T.5
  • 4
    • 79955021451 scopus 로고    scopus 로고
    • Retrospective multicenter analysis of immediate provisonalization using one-piece narrow-diameter (3.0 mm) implants
    • 21365052
    • Sohn DS, Bae MS, Heo JU, Park JS, Yea SH, Romanos GE (2011) Retrospective multicenter analysis of immediate provisonalization using one-piece narrow-diameter (3.0 mm) implants. Int J Oral Maxillofac Implants 26:163-168
    • (2011) Int J Oral Maxillofac Implants , vol.26 , pp. 163-168
    • Sohn, D.S.1    Bae, M.S.2    Heo, J.U.3    Park, J.S.4    Yea, S.H.5    Romanos, G.E.6
  • 5
    • 0014257582 scopus 로고
    • The blade vent - A new dimension in endosseous implantology
    • Linkow LI (1968) The blade vent - a new dimension in endosseous implantology. Dent Concepts 11:3-12
    • (1968) Dent Concepts , vol.11 , pp. 3-12
    • Linkow, L.I.1
  • 6
    • 0026834154 scopus 로고
    • Retrieval analyses of a blade implant after 231 months of clinical function
    • 1288796 1:STN:280:DyaK3s7mvFegtw%3D%3D
    • Linkow LI, Donath K, Lemons JE (1992) Retrieval analyses of a blade implant after 231 months of clinical function. Implant Dent 1:37-43
    • (1992) Implant Dent , vol.1 , pp. 37-43
    • Linkow, L.I.1    Donath, K.2    Lemons, J.E.3
  • 8
    • 0030322728 scopus 로고    scopus 로고
    • Types, uses, and evaluation of the plate-form implant
    • 9151633 1:STN:280:DyaK2s3ps1WntA%3D%3D
    • Roberts RA (1996) Types, uses, and evaluation of the plate-form implant. J Oral Implantol 22:111-118
    • (1996) J Oral Implantol , vol.22 , pp. 111-118
    • Roberts, R.A.1
  • 9
    • 0031263091 scopus 로고    scopus 로고
    • Implant rehabilitation of distal mandibular atrophy using a blade implant
    • 9471688
    • Veron C, Chanavaz M (1997) Implant rehabilitation of distal mandibular atrophy using a blade implant. Rev Stomatol Chir Maxillofac 98(Suppl 1):17-22
    • (1997) Rev Stomatol Chir Maxillofac , vol.98 , Issue.SUPPL. 1 , pp. 17-22
    • Veron, C.1    Chanavaz, M.2
  • 10
    • 0036356244 scopus 로고    scopus 로고
    • Placement of plate-form implants using osteotomes
    • 12498537 10.1563/1548-1336(2002)028<0283:POPIUO>2.3.CO;2
    • Roberts R (2002) Placement of plate-form implants using osteotomes. J Oral Implantol 28:283-289
    • (2002) J Oral Implantol , vol.28 , pp. 283-289
    • Roberts, R.1
  • 11
    • 79958041888 scopus 로고    scopus 로고
    • Fixed bicortical screw and blade implants as a non-standard solution to an edentulous (toothless) mandible
    • 20737937 10.4248/IJOS10030
    • Strecha J, Jurkovic R, Siebert T, Prachar P, Bartakova S (2010) Fixed bicortical screw and blade implants as a non-standard solution to an edentulous (toothless) mandible. Int J Oral Sci 2:105-110
    • (2010) Int J Oral Sci , vol.2 , pp. 105-110
    • Strecha, J.1    Jurkovic, R.2    Siebert, T.3    Prachar, P.4    Bartakova, S.5
  • 12
    • 0027597595 scopus 로고
    • A light microscopy, scanning electron microscopy and laser scanning microscopy analysis of retrieved blade implants after 7 to 20 years of clinical function
    • 8515367 10.1902/jop.1993.64.5.374 1:STN:280:DyaK3s3psVOjtg%3D%3D
    • Trisi P, Emanuelli M, Quaranta M, Piattelli A (1993) A light microscopy, scanning electron microscopy and laser scanning microscopy analysis of retrieved blade implants after 7 to 20 years of clinical function. J Periodontol 64:374-378
    • (1993) J Periodontol , vol.64 , pp. 374-378
    • Trisi, P.1    Emanuelli, M.2    Quaranta, M.3    Piattelli, A.4
  • 13
    • 0036550798 scopus 로고    scopus 로고
    • Evaluation of two Vitallium blade-form implants retrieved after 13 and 21 years of function: A clinical report
    • 12011855 10.1067/mpr.2002.122960
    • Proussaefs P, Lozada J (2002) Evaluation of two Vitallium blade-form implants retrieved after 13 and 21 years of function: a clinical report. J Prosthet Dent 87:412-415
    • (2002) J Prosthet Dent , vol.87 , pp. 412-415
    • Proussaefs, P.1    Lozada, J.2
  • 14
    • 33750737365 scopus 로고    scopus 로고
    • Immediately loaded blade implant retrieved from a man after a 20-year loading period: A histologic and histomorphometric case report
    • 17009561 10.1563/765.1
    • Di Stefano D, Iezzi G, Scarano A, Perrotti V, Piattelli A (2006) Immediately loaded blade implant retrieved from a man after a 20-year loading period: a histologic and histomorphometric case report. J Oral Implantol 32:171-176
    • (2006) J Oral Implantol , vol.32 , pp. 171-176
    • Di Stefano, D.1    Iezzi, G.2    Scarano, A.3    Perrotti, V.4    Piattelli, A.5
  • 15
    • 84355161961 scopus 로고    scopus 로고
    • The future of dental devices is digital
    • 22119539 10.1016/j.dental.2011.10.014
    • van Noort R (2012) The future of dental devices is digital. Dent Mater 28:3-12
    • (2012) Dent Mater , vol.28 , pp. 3-12
    • Van Noort, R.1
  • 16
    • 76949084294 scopus 로고    scopus 로고
    • Computer-assisted technique for the design and manufacture of realistic facial prostheses
    • 19556041 10.1016/j.bjoms.2009.05.009
    • Feng Z, Dong Y, Zhao Y, Bai S, Zhou B, Bi Y, Wu G (2010) Computer-assisted technique for the design and manufacture of realistic facial prostheses. Br J Oral Maxillofac Surg 48:105-109
    • (2010) Br J Oral Maxillofac Surg , vol.48 , pp. 105-109
    • Feng, Z.1    Dong, Y.2    Zhao, Y.3    Bai, S.4    Zhou, B.5    Bi, Y.6    Wu, G.7
  • 18
    • 84867785722 scopus 로고    scopus 로고
    • Custom-made, root-analogue direct laser metal forming implant: A case report
    • doi: 10.1007/s10103-012-1134-z
    • Mangano F, Cirotti B, Sammons R, Mangano C (2012) Custom-made, root-analogue direct laser metal forming implant: a case report. Lasers Med Sci. doi: 10.1007/s10103-012-1134-z
    • (2012) Lasers Med Sci.
    • Mangano, F.1    Cirotti, B.2    Sammons, R.3    Mangano, C.4
  • 19
    • 84862145994 scopus 로고    scopus 로고
    • Case report on a novel root analogue dental implant using CT scan and CAD/CAM - Selective laser melting technology
    • 22377004 10.1016/j.ijom.2012.01.014 1:STN:280:DC%2BC38vksl2ntg%3D%3D
    • Figliuzzi M, Mangano F, Mangano C (2012) Case report on a novel root analogue dental implant using CT scan and CAD/CAM - selective laser melting technology. Int J Oral Maxillofac Surg 41:858-862
    • (2012) Int J Oral Maxillofac Surg , vol.41 , pp. 858-862
    • Figliuzzi, M.1    Mangano, F.2    Mangano, C.3
  • 20
    • 77951824398 scopus 로고    scopus 로고
    • Laser direct writing of micro- and nano-scale medical devices
    • 20420557 10.1586/erd.10.14
    • Gittard SD, Narayan RJ (2010) Laser direct writing of micro- and nano-scale medical devices. Expert Rev Med Devices 7:343-356
    • (2010) Expert Rev Med Devices , vol.7 , pp. 343-356
    • Gittard, S.D.1    Narayan, R.J.2
  • 21
    • 76349093596 scopus 로고    scopus 로고
    • Novel use of an aerospace selective laser sintering machine for rapid prototyping of an orbital blowout fracture
    • 20064702 10.1016/j.ijom.2009.12.002 1:STN:280:DC%2BC3c7kt1amsg%3D%3D
    • Williams JV, Revington PJ (2010) Novel use of an aerospace selective laser sintering machine for rapid prototyping of an orbital blowout fracture. Int J Oral Maxillofac Surg 39:182-184
    • (2010) Int J Oral Maxillofac Surg , vol.39 , pp. 182-184
    • Williams, J.V.1    Revington, P.J.2
  • 22
    • 45749091695 scopus 로고    scopus 로고
    • Selective laser sintering technology for customized fabrication of facial prostheses
    • 18589076 10.1016/S0022-3913(08)60138-9
    • Wu G, Zhou B, Bi Y, Zhao Y (2008) Selective laser sintering technology for customized fabrication of facial prostheses. J Prosthet Dent 100:56-60
    • (2008) J Prosthet Dent , vol.100 , pp. 56-60
    • Wu, G.1    Zhou, B.2    Bi, Y.3    Zhao, Y.4
  • 23
    • 52049098001 scopus 로고    scopus 로고
    • Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants
    • 18502498 10.1016/j.dental.2008.03.029 1:CAS:528:DC%2BD1cXhtFCgu7bM
    • Traini T, Mangano C, Sammons RL (2008) Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants. Dent Mater 24:1525-1533
    • (2008) Dent Mater , vol.24 , pp. 1525-1533
    • Traini, T.1    Mangano, C.2    Sammons, R.L.3
  • 25
    • 79955687907 scopus 로고    scopus 로고
    • Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: A case series
    • 20803160 10.1007/s10103-010-0831-8
    • Mangano C, Piattelli A, Iezzi G, Mangano F, Raspanti M, Shibli JA, Cassoni A (2011) Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series. Lasers Med Sci 26:133-138
    • (2011) Lasers Med Sci , vol.26 , pp. 133-138
    • Mangano, C.1    Piattelli, A.2    Iezzi, G.3    Mangano, F.4    Raspanti, M.5    Shibli, J.A.6    Cassoni, A.7
  • 26
    • 84856014745 scopus 로고    scopus 로고
    • Immediate loading of mandibular overdentures supported by unsplinted direct laser metal forming (DLMF) implants. Results from a 1-year prospective study
    • 21627459 10.1902/jop.2011.110079 1:CAS:528:DC%2BC38XjsVSlt74%3D
    • Mangano C, Mangano F, Shibli JA, Ricci M, Perrotti V, d'Avila S, Piattelli A (2012) Immediate loading of mandibular overdentures supported by unsplinted direct laser metal forming (DLMF) implants. Results from a 1-year prospective study. J Periodontol 83:70-78
    • (2012) J Periodontol , vol.83 , pp. 70-78
    • Mangano, C.1    Mangano, F.2    Shibli, J.A.3    Ricci, M.4    Perrotti, V.5    D'Avila, S.6    Piattelli, A.7
  • 28
    • 0027024820 scopus 로고
    • Correlative transmission electron microscopic and scanning electron microscopic observations of the tissues supporting endosteal blade implants
    • Steflik DE, Sisk AL, Parr GR, Hanes PJ, Lake FT, Brewer P, Horner J, McKinney RV (1992) Correlative transmission electron microscopic and scanning electron microscopic observations of the tissues supporting endosteal blade implants. J Oral Implantol 27:110-120
    • (1992) J Oral Implantol , vol.27 , pp. 110-120
    • Steflik, D.E.1    Sisk, A.L.2    Parr, G.R.3    Hanes, P.J.4    Lake, F.T.5    Brewer, P.6    Horner, J.7    McKinney, R.V.8
  • 30
    • 67650242372 scopus 로고    scopus 로고
    • Preoperative accuracy of selective laser sintering (SLS) in craniofacial 3D modeling: Comparison with patient CT data
    • 19253203 10.1055/s-0028-1109204 1:STN:280:DC%2BD1MvktlGhsg%3D%3D
    • Kaim AH, Kirsch EC, Alder P, Bucher P, Hammer B (2009) Preoperative accuracy of selective laser sintering (SLS) in craniofacial 3D modeling: comparison with patient CT data. Rofo 181:644-651
    • (2009) Rofo , vol.181 , pp. 644-651
    • Kaim, A.H.1    Kirsch, E.C.2    Alder, P.3    Bucher, P.4    Hammer, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.