메뉴 건너뛰기




Volumn 41, Issue 7, 2012, Pages 858-862

A novel root analogue dental implant using CT scan and CAD/CAM: Selective laser melting technology

Author keywords

custom made root analogue implants; direct laser metal forming; immediate implants; primary stability

Indexed keywords

ADULT; ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER AIDED DESIGN; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; DENTAL TECHNOLOGY; DIRECT LASER METAL FORMING IMPLANT; FEMALE; FOLLOW UP; HUMAN; LASER MELTING TECHNOLOGY; MAXILLA; NANOFABRICATION; NORMAL HUMAN; OUTCOME ASSESSMENT; PREMOLAR TOOTH; THREE DIMENSIONAL IMAGING; TOOTH EXTRACTION; TOOTH IMPLANTATION; TOOTH SOCKET;

EID: 84862145994     PISSN: 09015027     EISSN: 13990020     Source Type: Journal    
DOI: 10.1016/j.ijom.2012.01.014     Document Type: Article
Times cited : (102)

References (10)
  • 1
    • 0014574910 scopus 로고
    • The dental polymer implant concept
    • M. Hodosh, M. Povar, and G. Shklar The dental polymer implant concept J Prosthet Dent 22 1969 371 380
    • (1969) J Prosthet Dent , vol.22 , pp. 371-380
    • Hodosh, M.1    Povar, M.2    Shklar, G.3
  • 2
    • 77951047569 scopus 로고    scopus 로고
    • Immediate implant placement: Positives and negatives
    • R. Koh, I. Rudek, and H.L. Wang Immediate implant placement: positives and negatives Implant Dent 19 2010 98 108
    • (2010) Implant Dent , vol.19 , pp. 98-108
    • Koh, R.1    Rudek, I.2    Wang, H.L.3
  • 3
    • 40249104431 scopus 로고    scopus 로고
    • Clinical investigation of a new dental immediate implant system. The reimplant-system
    • R.J. Kohal, G. Klaus, and J.R. Strubl Clinical investigation of a new dental immediate implant system. The reimplant-system Dtsch Zahnarztl Z 57 2002 495 497
    • (2002) Dtsch Zahnarztl Z , vol.57 , pp. 495-497
    • Kohal, R.J.1    Klaus, G.2    Strubl, J.R.3
  • 4
    • 0026922309 scopus 로고
    • Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog
    • D. Lundgren, H. Rylander, M. Andersson, C. Johansson, and T. Albrektsson Healing-in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog Clin Oral Implants Res 3 1992 136 144
    • (1992) Clin Oral Implants Res , vol.3 , pp. 136-144
    • Lundgren, D.1    Rylander, H.2    Andersson, M.3    Johansson, C.4    Albrektsson, T.5
  • 5
    • 84856014745 scopus 로고    scopus 로고
    • Immediate loading of mandibular overdentures supported by unsplinted direct laser metal forming (DLMF) implants. Results from a 1-year prospective study
    • C. Mangano, F. Mangano, J.A. Shibli, M. Ricci, V. Perrotti, S. d'Avila, and A. Piattelli Immediate loading of mandibular overdentures supported by unsplinted direct laser metal forming (DLMF) implants. Results from a 1-year prospective study J Periodontol 83 2012 70 78
    • (2012) J Periodontol , vol.83 , pp. 70-78
    • Mangano, C.1    Mangano, F.2    Shibli, J.A.3    Ricci, M.4    Perrotti, V.5    D'Avila, S.6    Piattelli, A.7
  • 6
    • 84880699410 scopus 로고    scopus 로고
    • Designing a novel dental root analogue implant using cone beam computed tomography and CAD/CAM technology
    • 10.1111/j.1600-0501.2011.02359.x November 14 [Epub ahead of print]
    • D.A. Moin, B. Hassan, P. Mercelis, and D. Wismeijer Designing a novel dental root analogue implant using cone beam computed tomography and CAD/CAM technology Clin Oral Implants Res 2011 10.1111/j.1600-0501.2011.02359.x November 14 [Epub ahead of print]
    • (2011) Clin Oral Implants Res
    • Moin, D.A.1    Hassan, B.2    Mercelis, P.3    Wismeijer, D.4
  • 7
    • 40249098654 scopus 로고    scopus 로고
    • Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement
    • W. Pirker, and A. Kocher Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement Int J Oral Maxillofac Surg 37 2008 293 295
    • (2008) Int J Oral Maxillofac Surg , vol.37 , pp. 293-295
    • Pirker, W.1    Kocher, A.2
  • 8
    • 71249138907 scopus 로고    scopus 로고
    • Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study
    • W. Pirker, and A. Kocher Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study Int J Oral Maxillofac Surg 38 2009 1127 1132
    • (2009) Int J Oral Maxillofac Surg , vol.38 , pp. 1127-1132
    • Pirker, W.1    Kocher, A.2
  • 9
    • 79951951006 scopus 로고    scopus 로고
    • Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: A case report with 2.5 years follow-up
    • W. Pirker, D. Wiedemann, A. Lidauer, and A. Kocher Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow-up Int J Oral Maxillofac Surg 40 2011 212 216
    • (2011) Int J Oral Maxillofac Surg , vol.40 , pp. 212-216
    • Pirker, W.1    Wiedemann, D.2    Lidauer, A.3    Kocher, A.4
  • 10
    • 84862138342 scopus 로고    scopus 로고
    • An overview of immediate root analogue zirconia implants
    • September 9 [Epub ahead of print]
    • K.M.R. Sharma, and D. Drp An overview of immediate root analogue zirconia implants J Oral Implantol 2011 September 9 [Epub ahead of print]
    • (2011) J Oral Implantol
    • Sharma, K.M.R.1    Drp, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.