메뉴 건너뛰기




Volumn 112, Issue , 2013, Pages 1016-1024

Analysis and prediction of daylighting and energy performance in atrium spaces using daylight-linked lighting controls

Author keywords

Atrium; Daylight; Daylight linked lighting controls; Energy savings; Greenhouse gases

Indexed keywords

DESIGN; ELECTRIC LIGHTING; ELECTRICITY; ENERGY CONSERVATION; ENERGY EFFICIENCY; GREENHOUSE GASES; OFFICE BUILDINGS;

EID: 84884286443     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2012.12.033     Document Type: Article
Times cited : (67)

References (35)
  • 1
    • 84855262554 scopus 로고    scopus 로고
    • Technical performance evaluation of stand-alone photovoltaic array for outdoor field conditions of New Delhi
    • Tiwari G.N., Sharma R. Technical performance evaluation of stand-alone photovoltaic array for outdoor field conditions of New Delhi. Appl Energy 2012, 92:644-652.
    • (2012) Appl Energy , vol.92 , pp. 644-652
    • Tiwari, G.N.1    Sharma, R.2
  • 2
    • 33644553087 scopus 로고    scopus 로고
    • The all-sky meteorological radiation model: proposed improvements
    • Muneer T., Younes S. The all-sky meteorological radiation model: proposed improvements. Appl Energy 2006, 83:436-450.
    • (2006) Appl Energy , vol.83 , pp. 436-450
    • Muneer, T.1    Younes, S.2
  • 3
    • 77953147443 scopus 로고    scopus 로고
    • A review of daylight illuminance determinations and energy implications
    • Li D.H.W. A review of daylight illuminance determinations and energy implications. Appl Energy 2010, 87:2109-2118.
    • (2010) Appl Energy , vol.87 , pp. 2109-2118
    • Li, D.H.W.1
  • 4
    • 43949098287 scopus 로고    scopus 로고
    • An analysis of daylighting performance for office buildings in Hong Kong
    • Li D.H.W., Tsang E.K.W. An analysis of daylighting performance for office buildings in Hong Kong. Build Environ 2008, 43(9):1446-1458.
    • (2008) Build Environ , vol.43 , Issue.9 , pp. 1446-1458
    • Li, D.H.W.1    Tsang, E.K.W.2
  • 5
    • 0041118740 scopus 로고    scopus 로고
    • Occupant reactions to daylight in offices
    • Roche L., Dewey E., Littlefair P.J. Occupant reactions to daylight in offices. Light Res Technol 2000, 32(3):119-126.
    • (2000) Light Res Technol , vol.32 , Issue.3 , pp. 119-126
    • Roche, L.1    Dewey, E.2    Littlefair, P.J.3
  • 6
    • 84859424242 scopus 로고    scopus 로고
    • Considerations on design optimization criteria for windows providing low energy consumption and high visual comfort
    • Ochoa C.E., Aries M.B.C., Loenen E.J.V., Hensen J.L.M. Considerations on design optimization criteria for windows providing low energy consumption and high visual comfort. Appl Energy 2012, 95:238-245.
    • (2012) Appl Energy , vol.95 , pp. 238-245
    • Ochoa, C.E.1    Aries, M.B.C.2    Loenen, E.J.V.3    Hensen, J.L.M.4
  • 7
    • 34548324707 scopus 로고    scopus 로고
    • Daylighting and energy implications due to shading effects from nearby buildings
    • Li D.H.W., Wong S.L. Daylighting and energy implications due to shading effects from nearby buildings. Appl Energy 2007, 84:1199-1209.
    • (2007) Appl Energy , vol.84 , pp. 1199-1209
    • Li, D.H.W.1    Wong, S.L.2
  • 8
    • 77953308556 scopus 로고    scopus 로고
    • Performance of anidolic daylighting systems in tropical climates - parametric studies for identification of main influencing factors
    • Linharta F. Performance of anidolic daylighting systems in tropical climates - parametric studies for identification of main influencing factors. Sol Energy 2010, 84(7):1085-1094.
    • (2010) Sol Energy , vol.84 , Issue.7 , pp. 1085-1094
    • Linharta, F.1
  • 9
    • 0035442256 scopus 로고    scopus 로고
    • A review on architectural aspects of atrium buildings
    • Hung W.Y., Chow W.K. A review on architectural aspects of atrium buildings. Archit Sci Rev 2001, 44(3):285-296.
    • (2001) Archit Sci Rev , vol.44 , Issue.3 , pp. 285-296
    • Hung, W.Y.1    Chow, W.K.2
  • 10
    • 77954030209 scopus 로고    scopus 로고
    • A modified model for estimation of daylight factor for skylight integrated with dome roof structure of mud-house in New Delhi India
    • Tiwari G.N. A modified model for estimation of daylight factor for skylight integrated with dome roof structure of mud-house in New Delhi India. Appl Energy 2010, 87:3037-3050.
    • (2010) Appl Energy , vol.87 , pp. 3037-3050
    • Tiwari, G.N.1
  • 11
    • 0039508760 scopus 로고    scopus 로고
    • Illuminance in atria: review of prediction methods
    • Wright J., Letherman K. Illuminance in atria: review of prediction methods. Light Res Technol 1998, 30(1):1-10.
    • (1998) Light Res Technol , vol.30 , Issue.1 , pp. 1-10
    • Wright, J.1    Letherman, K.2
  • 12
    • 0029521592 scopus 로고
    • The daylighting of atria: a critical review
    • Aizlewood M. The daylighting of atria: a critical review. ASHRAE Trans 1995, 101:841-857.
    • (1995) ASHRAE Trans , vol.101 , pp. 841-857
    • Aizlewood, M.1
  • 13
    • 0141708687 scopus 로고    scopus 로고
    • An analysis of lighting energy savings and switching frequency for a daylit corridor under various indoor design illuminance levels
    • Li D.H.W., Lam J.C. An analysis of lighting energy savings and switching frequency for a daylit corridor under various indoor design illuminance levels. Appl Energy 2003, 76(4):363-378.
    • (2003) Appl Energy , vol.76 , Issue.4 , pp. 363-378
    • Li, D.H.W.1    Lam, J.C.2
  • 14
    • 37349119787 scopus 로고    scopus 로고
    • The role of spectral response of photosensors in daylight responsive systems
    • Doulos L., Tsangrassoulis A., Topalis F.V. The role of spectral response of photosensors in daylight responsive systems. Energy Build 2008, 40(4):588-599.
    • (2008) Energy Build , vol.40 , Issue.4 , pp. 588-599
    • Doulos, L.1    Tsangrassoulis, A.2    Topalis, F.V.3
  • 15
    • 0002642788 scopus 로고    scopus 로고
    • Measured energy savings due to photocell control of individual luminaries
    • Knight I.P. Measured energy savings due to photocell control of individual luminaries. Light Res Technol 1999, 31(1):19-22.
    • (1999) Light Res Technol , vol.31 , Issue.1 , pp. 19-22
    • Knight, I.P.1
  • 16
    • 20544473370 scopus 로고    scopus 로고
    • Daylighting monitoring protocols and procedures for buildings
    • A Report of Task 21/Annex 29: Daylight in Building
    • Atif MR, Love JA, Littlefair P. Daylighting monitoring protocols and procedures for buildings. A Report of Task 21/Annex 29: Daylight in Building; 1997.
    • (1997)
    • Atif, M.R.1    Love, J.A.2    Littlefair, P.3
  • 17
    • 77955652100 scopus 로고    scopus 로고
    • A critical review of articles published on atrium geometry and surface reflectances on daylighting in an atrium and its adjoining spaces
    • Samant S. A critical review of articles published on atrium geometry and surface reflectances on daylighting in an atrium and its adjoining spaces. Archit Sci Rev 2010, 53(2):145-156.
    • (2010) Archit Sci Rev , vol.53 , Issue.2 , pp. 145-156
    • Samant, S.1
  • 19
    • 0028697082 scopus 로고
    • Instrumentation system for evaluating daylighting performance in sunlit atria with design-stage scale models
    • Song K., Boyer L. Instrumentation system for evaluating daylighting performance in sunlit atria with design-stage scale models. ASHRAE Trans 1994, 100:696-702.
    • (1994) ASHRAE Trans , vol.100 , pp. 696-702
    • Song, K.1    Boyer, L.2
  • 20
    • 1842715574 scopus 로고    scopus 로고
    • Daylight factor prediction in atria building designs
    • Calcagni B., Parongini M. Daylight factor prediction in atria building designs. Sol Energy 2004, 76(6):669-682.
    • (2004) Sol Energy , vol.76 , Issue.6 , pp. 669-682
    • Calcagni, B.1    Parongini, M.2
  • 21
    • 84884282530 scopus 로고    scopus 로고
    • Electrical and Mechanical Services Department. Code of practice for energy efficiency of lighting installations, 2007 ed. Electrical and Mechanical Services Department, Hong Kong Special Administrative Region
    • Electrical and Mechanical Services Department. Code of practice for energy efficiency of lighting installations, 2007 ed. Electrical and Mechanical Services Department, Hong Kong Special Administrative Region, 2007.
    • (2007)
  • 23
    • 14844283830 scopus 로고    scopus 로고
    • An analysis of measured and simulated daylight illuminance and lighting savings in a daylit corridor
    • Li D.H.W., Tsang E.K.W. An analysis of measured and simulated daylight illuminance and lighting savings in a daylit corridor. Build Environ 2005, 40(7):973-982.
    • (2005) Build Environ , vol.40 , Issue.7 , pp. 973-982
    • Li, D.H.W.1    Tsang, E.K.W.2
  • 24
    • 0003675235 scopus 로고
    • CIBSE, London, Chartered Institute of Building Services Engineers
    • Chartered Institute of Building Services Engineers CIBSE Code for Interior Lighting 1994, CIBSE, London.
    • (1994) CIBSE Code for Interior Lighting
  • 25
    • 84884290876 scopus 로고    scopus 로고
    • China Light and Power Co. Ltd. website: <>
    • China Light and Power Co. Ltd. website: <>. http://www.clpgroup.com/Pages/home.aspx.
  • 26
    • 84869113056 scopus 로고    scopus 로고
    • Electrical and Mechanical Services Department, Hong Kong Special Administrative Region, Electrical and Mechanical Services Department
    • Electrical and Mechanical Services Department Hong Kong Energy end-use data 2009, Electrical and Mechanical Services Department, Hong Kong Special Administrative Region.
    • (2009) Hong Kong Energy end-use data
  • 27
    • 75449094502 scopus 로고    scopus 로고
    • An analysis of energy-efficient light fittings and lighting controls
    • Li D.H.W., Cheung K.L., Wong S.L., Lam T.N.T. An analysis of energy-efficient light fittings and lighting controls. Appl Energy 2010, 87:558-567.
    • (2010) Appl Energy , vol.87 , pp. 558-567
    • Li, D.H.W.1    Cheung, K.L.2    Wong, S.L.3    Lam, T.N.T.4
  • 28
    • 0000706831 scopus 로고    scopus 로고
    • Predicting lighting energy use under daylight linked lighting controls
    • Littlefair P.J. Predicting lighting energy use under daylight linked lighting controls. Build Res Inform 1998, 26(4):208-222.
    • (1998) Build Res Inform , vol.26 , Issue.4 , pp. 208-222
    • Littlefair, P.J.1
  • 29
    • 0036459633 scopus 로고    scopus 로고
    • Daylight prediction in atrium buildings
    • Littlefair P.J. Daylight prediction in atrium buildings. Sol Energy 2002, 73(2):105-109.
    • (2002) Sol Energy , vol.73 , Issue.2 , pp. 105-109
    • Littlefair, P.J.1
  • 30
    • 84884286727 scopus 로고
    • British Standards Institution. Code of practice for daylighting. British Standard BS8206, Part 2. BSI, London
    • British Standards Institution. Code of practice for daylighting. British Standard BS8206, Part 2. BSI, London; 1992.
    • (1992)
  • 31
    • 84884288766 scopus 로고    scopus 로고
    • Average daylight factor: a simple basis for daylight design
    • Build Res Inform Paper 15/88. Construction Research Communications, Garston, UK
    • Littlefair PJ. Average daylight factor: a simple basis for daylight design. Build Res Inform Paper 15/88. Construction Research Communications, Garston, UK; 1998.
    • (1998)
    • Littlefair, P.J.1
  • 32
    • 84965400606 scopus 로고
    • A sequence for daylighting design
    • Lynes J.A. A sequence for daylighting design. Light Res Technol 1979, 11(2):102-106.
    • (1979) Light Res Technol , vol.11 , Issue.2 , pp. 102-106
    • Lynes, J.A.1
  • 33
    • 84964193404 scopus 로고
    • Lighting energy saving from daylight: estimation at the sketch design stage
    • Lynes J.A., Littlefair P.J. Lighting energy saving from daylight: estimation at the sketch design stage. Light Res Technol 1990, 22(3):129-137.
    • (1990) Light Res Technol , vol.22 , Issue.3 , pp. 129-137
    • Lynes, J.A.1    Littlefair, P.J.2
  • 34
    • 0019718062 scopus 로고
    • The illuminance distribution of an average sky
    • Littlefair P.J. The illuminance distribution of an average sky. Light Res Technol 1981, 13(4):192-198.
    • (1981) Light Res Technol , vol.13 , Issue.4 , pp. 192-198
    • Littlefair, P.J.1
  • 35
    • 57049117356 scopus 로고    scopus 로고
    • Estimation of lighting energy savings from daylighting
    • Ihm P., Nemri A., Krarti M. Estimation of lighting energy savings from daylighting. Build Environ 2009, 44(3):509-514.
    • (2009) Build Environ , vol.44 , Issue.3 , pp. 509-514
    • Ihm, P.1    Nemri, A.2    Krarti, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.