-
1
-
-
85023987104
-
Inside the livable city: The atrium
-
C. Kent “Inside the livable city: The atrium” Inland Architect, Vol. 33, No. 1, p. 36-43 (1989).
-
(1989)
Inland Architect
, vol.33
, Issue.1
, pp. 36-43
-
-
Kent, C.1
-
2
-
-
85024021869
-
Yamashita Sekkei: Recent works”
-
“Amenity space for interaction, Tokyo
-
“Amenity space for interaction: Yamashita Sekkei: Recent works” Process Architecture, Tokyo, p. 16-37 (1989).
-
(1989)
Process Architecture
, pp. 16-37
-
-
-
4
-
-
85024062225
-
Atrium buildings
-
A Jackson, et al. “Atrium buildings” Canadian Architect, Vol. 42, Pan 4, p. 22-36 (1997).
-
(1997)
Canadian Architect
, vol.42
, pp. 22-36
-
-
Jackson, A.1
-
5
-
-
84865791414
-
Climatic responsive atrium design in Europe
-
D. Ho “Climatic responsive atrium design in Europe” ARQ: Architectural Research Quarterly, Vol. 1, Pan 3, p. 64-75 (1996).
-
(1996)
ARQ: Architectural Research Quarterly
, vol.1
, pp. 64-75
-
-
Ho, D.1
-
6
-
-
84914783086
-
-
Building Technical File, No. 21
-
N. Baker “The atrium environment” Building Technical File, No. 21, p. 39-48 (1988).
-
(1988)
The Atrium Environment
, pp. 39-48
-
-
Baker, N.1
-
7
-
-
85023986276
-
The atrium future forms in an old space
-
M. Benyon “The atrium future forms in an old space” Canadian Architect, Vol. 27, No. 7, p. 14-23 (1982).
-
(1982)
Canadian Architect
, vol.27
, Issue.7
, pp. 14-23
-
-
Benyon, M.1
-
9
-
-
85024021556
-
-
explores the Hong Kong skyline” Building Journal Hong Kong China, August 1985
-
“Hongkong Bank headquarters building: An eye-catching “spacescraper” explores the Hong Kong skyline” Building Journal Hong Kong China, August 1985, p. 62-86 (1985).
-
(1985)
Hongkong Bank Headquarters Building: An Eye-Catching “spacescraper
, pp. 62-86
-
-
-
10
-
-
85024056110
-
-
Building joumal Hong Kong China, August 1997
-
J. Doyle “Palace Mall: Sunken treasure” Building joumal Hong Kong China, August 1997, p. 34-39 (1997).
-
(1997)
“Palace Mall: Sunken Treasure
, pp. 34-39
-
-
Doyle, J.1
-
11
-
-
24944469217
-
-
Building Ordinance, Hong Kong Special Administrative Region
-
“Cap. 123F, Building (Planning) Regulations”, Building Ordinance, Hong Kong Special Administrative Region (1997).
-
(1997)
Cap. 123F, Building (Planning) Regulations
-
-
-
12
-
-
84897226282
-
-
edited by V. Magnago Lampugnani, Prestel Verlag: New York
-
“Hong Kong architecture: the aesthetics of density”, edited by V. Magnago Lampugnani, Prestel Verlag: New York (1993).
-
(1993)
Hong Kong Architecture: The Aesthetics of Density
-
-
-
13
-
-
85023965583
-
-
HKIA Journal, PACE Publishing: Hong Kong
-
“HKIA annual awards and exhibitions 97” HKIA Journal, PACE Publishing: Hong Kong (1998).
-
(1998)
HKIA Annual Awards and Exhibitions 97
-
-
-
14
-
-
85023967370
-
Smoke control in atrium buildings Building Control
-
G.O. Hansell “Smoke control in atrium buildings” Building Control, No. 22, p. 40-51 (1987).
-
(1987)
No
, vol.22
, pp. 40-51
-
-
Hansell, G.O.1
-
18
-
-
0032231116
-
A case study of fire protection in large stadia: The San Antonio Alamodome
-
G.P. Corbett “A case study of fire protection in large stadia: The San Antonio Alamodome” Journal of Applied Fire Science, Vol. 8, No. 2, p. 117-132 (1998-99).
-
(1998)
Journal of Applied Fire Science
, vol.8
, Issue.2
, pp. 117-132
-
-
Corbett, G.P.1
-
19
-
-
0035238896
-
Natural smoke filling in atrium with liquid pool fires up to 1.6 MW
-
W.K. Chow, Y.Z. Li, E Cui and R. Huo “Natural smoke filling in atrium with liquid pool fires up to 1.6 MW” Building and Environment, Vol. 36, No. 1, p. 121-127(2001).
-
(2001)
Building and Environment
, vol.36
, Issue.1
, pp. 121-127
-
-
Chow, W.K.1
Li, Y.Z.2
Cui, E.3
Huo, R.4
-
20
-
-
0003928622
-
-
NFPA92B, National Fire Protection Association, Quincy, MA, USA
-
“Guide for smoke management systems in malls, atria and large areas” NFPA92B, National Fire Protection Association, Quincy, MA, USA (1995).
-
(1995)
Guide for Smoke Management Systems in Malls, Atria and Large Areas
-
-
-
21
-
-
0033280695
-
Smoke control by air curtain for spaces adjacent to atria
-
W.K. Chow “Smoke control by air curtain for spaces adjacent to atria” Journal of Environmental Systems, Vol. 27, No. 2, p. 151-162 (1999).
-
(1999)
Journal of Environmental Systems
, vol.27
, Issue.2
, pp. 151-162
-
-
Chow, W.K.1
-
22
-
-
85023981777
-
-
System Safety Society: Proceedings of the /6”International System Safety Conference on System Safety on the Frontier of Technology, Fort Worth, Texas, U.S.A, 11-16 September, 2000
-
G.C.H. Lui and W.K. Chow “A preliminary proposal on fire safety management for karaoke establishments” System Safety Society: Proceedings of the /6”International System Safety Conference on System Safety on the Frontier of Technology, Fort Worth, Texas, U.S.A, 11-16 September, 2000, p. 76-84 (2000).
-
(2000)
A Preliminary Proposal on Fire Safety Management for Karaoke Establishments
, pp. 76-84
-
-
Lui, G.C.H.1
Chow, W.K.2
-
23
-
-
80052627157
-
-
Fire Code Reform, Final Research Report: Project 6, Fire Code Reform Research Program, Sydney, Australia, July
-
Fire Code Reform “Fire safety in shopping centres” Final Research Report: Project 6, Fire Code Reform Research Program, Sydney, Australia, July (1998).
-
(1998)
Fire Safety in Shopping Centres
-
-
|