메뉴 건너뛰기




Volumn 7, Issue 3, 2013, Pages

Correlations between blood glucose and breath components from portable gas sensors and PTR-TOF-MS

Author keywords

[No Author keywords available]

Indexed keywords

ACETONE; ALCOHOL; GLUCOSE; ISOPRENE; METHANOL; NANOMATERIAL; BIOLOGICAL MARKER;

EID: 84884159705     PISSN: 17527155     EISSN: 17527163     Source Type: Journal    
DOI: 10.1088/1752-7155/7/3/037110     Document Type: Article
Times cited : (100)

References (45)
  • 1
    • 0020693943 scopus 로고
    • The diagnostic potential of breath analysis
    • Manolis A 1983 The diagnostic potential of breath analysis Clin. Chem. 29 5-15 (Pubitemid 13167610)
    • (1983) Clinical Chemistry , vol.29 , Issue.1 , pp. 5-15
    • Manolis, A.1
  • 2
    • 70449378196 scopus 로고    scopus 로고
    • Noninvasive detection of lung cancer by analysis of exhaled breath
    • 10.1186/1471-2407-9-348 1471-2407
    • Bajtarevic A et al 2009 Noninvasive detection of lung cancer by analysis of exhaled breath BMC Cancer 9 348
    • (2009) BMC Cancer , vol.9 , Issue.1 , pp. 348
    • Bajtarevic, A.1
  • 3
    • 33646338915 scopus 로고    scopus 로고
    • Breath analysis: Potential for clinical diagnosis and exposure assessment
    • DOI 10.1373/clinchem.2005.063545
    • Cao W Q and Duan Y X 2006 Breath analysis: potential for clinical diagnosis and exposure assessment Clin. Chem. 52 800-11 (Pubitemid 43673257)
    • (2006) Clinical Chemistry , vol.52 , Issue.5 , pp. 800-811
    • Cao, W.1    Duan, Y.2
  • 4
    • 0030939301 scopus 로고    scopus 로고
    • Exhaled human breath measurement method for assessing exposure to halogenated volatile organic compounds
    • Pleil J D and Lindstrom A B 1997 Exhaled human breath measurement method for assessing exposure to halogenated volatile organic compounds Clin. Chem. 43 723-30 (Pubitemid 27208772)
    • (1997) Clinical Chemistry , vol.43 , Issue.5 , pp. 723-730
    • Pleil, J.D.1    Lindstrom, A.B.2
  • 7
    • 0032724364 scopus 로고    scopus 로고
    • Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: A preliminary study
    • Smith D, Spanel P and Davies S 1999 Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: a preliminary study J. Appl. Physiol. 87 1584-8
    • (1999) J. Appl. Physiol. , vol.87 , pp. 1584-1588
    • Smith, D.1    Spanel, P.2    Davies, S.3
  • 8
    • 36849055638 scopus 로고    scopus 로고
    • Monitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: An observational study
    • 10.1186/1749-8090-2-37 1749-8090
    • Pabst F, Miekisch W, Fuchs P, Kischkel S and Schubert J K 2007 Monitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: an observational study J. Cardiothorac. Surg. 2 37
    • (2007) J. Cardiothorac. Surg. , vol.2 , Issue.1 , pp. 37
    • Pabst, F.1    Miekisch, W.2    Fuchs, P.3    Kischkel, S.4    Schubert, J.K.5
  • 9
    • 33749016240 scopus 로고    scopus 로고
    • Current status of clinical breath analysis
    • DOI 10.1007/s00340-006-2280-4, Optics: Trends in Laser Sources, Spectroscopic Techniques and their Applications to Trace Gas-Detection
    • Risby T H and Solga S F 2006 Current status of clinical breath analysis Appl. Phys. B 85 421-6 (Pubitemid 44451363)
    • (2006) Applied Physics B: Lasers and Optics , vol.85 , Issue.2-3 , pp. 421-426
    • Risby, T.H.1    Solga, S.F.2
  • 11
    • 80054023459 scopus 로고    scopus 로고
    • A mathematical model for breath gas analysis of volatile organic compounds with special emphasis on acetone
    • 10.1007/s00285-010-0398-9 0303-6812
    • King J, Unterkofler K, Teschl G, Teschl S, Koc H, Hinterhuber H and Amann A 2011 A mathematical model for breath gas analysis of volatile organic compounds with special emphasis on acetone J. Math. Biol. 63 959-99
    • (2011) J. Math. Biol. , vol.63 , Issue.5 , pp. 959-999
    • King, J.1    Unterkofler, K.2    Teschl, G.3    Teschl, S.4    Koc, H.5    Hinterhuber, H.6    Amann, A.7
  • 12
    • 68149136300 scopus 로고    scopus 로고
    • Breath acetone - Aspects of normal physiology related to age and gender as determined in a PTR-MS study
    • 1752-7155 027003
    • Schwarz K et al 2009 Breath acetone - aspects of normal physiology related to age and gender as determined in a PTR-MS study J. Breath Res. 3 027003
    • (2009) J. Breath Res. , vol.3
    • Schwarz, K.1
  • 13
    • 17444399677 scopus 로고    scopus 로고
    • Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis
    • DOI 10.1002/mas.20033
    • Smith D and Spanel P 2005 Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis Mass Spectrom. Rev. 24 661-700 (Pubitemid 41615714)
    • (2005) Mass Spectrometry Reviews , vol.24 , Issue.5 , pp. 661-700
    • Smith, D.1    Spanel, P.2
  • 14
    • 29144508524 scopus 로고    scopus 로고
    • A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry
    • DOI 10.1002/rcm.2275
    • Turner C, Spanel P and Smith D 2006 A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry Rapid Commun. Mass Spectrom. 20 61-68 (Pubitemid 41815180)
    • (2006) Rapid Communications in Mass Spectrometry , vol.20 , Issue.1 , pp. 61-68
    • Turner, C.1    Spanel, P.2    Smith, D.3
  • 16
    • 85008060882 scopus 로고    scopus 로고
    • Analysis of volatile and non-volatile biomarkers in human breath using differential mobility spectrometry (DMS)
    • 10.1109/JSEN.2009.2033562 1530-437X
    • Davis C E et al 2010 Analysis of volatile and non-volatile biomarkers in human breath using differential mobility spectrometry (DMS) IEEE Sensors J. 10 114-22
    • (2010) IEEE Sensors J. , vol.10 , Issue.1 , pp. 114-122
    • Davis, C.E.1
  • 18
    • 77951794989 scopus 로고    scopus 로고
    • 3 sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis
    • 10.1021/ac902695n 0003-2700
    • 3 sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis Anal. Chem. 82 3581-7
    • (2010) Anal. Chem. , vol.82 , Issue.9 , pp. 3581-3587
    • Righettoni, M.1    Tricoli, A.2    Pratsinis, S.E.3
  • 19
    • 78249266634 scopus 로고    scopus 로고
    • Semiconductor gas sensors: Dry synthesis and application
    • 10.1002/anie.200903801 1433-7851
    • Tricoli A, Righettoni M and Teleki A 2010 Semiconductor gas sensors: dry synthesis and application Angew. Chem.,Int. Edn Engl. 49 7632-59
    • (2010) Angew. Chem.,Int. Edn Engl. , vol.49 , Issue.42 , pp. 7632-7659
    • Tricoli, A.1    Righettoni, M.2    Teleki, A.3
  • 20
    • 80052711835 scopus 로고    scopus 로고
    • Toward portable breath acetone analysis for diabetes detection
    • 1752-7155 037109
    • Righettoni M and Tricoli A 2011 Toward portable breath acetone analysis for diabetes detection J. Breath Res. 5 037109
    • (2011) J. Breath Res. , vol.5
    • Righettoni, M.1    Tricoli, A.2
  • 22
    • 0033526615 scopus 로고    scopus 로고
    • Volatile organic compounds in breath as markers of lung cancer: A cross-sectional study
    • DOI 10.1016/S0140-6736(98)07552-7
    • Phillips M, Gleeson K, Hughes J M B, Greenberg J, Cataneo R N, Baker L and McVay W P 1999 Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study Lancet 353 1930-3 (Pubitemid 29255706)
    • (1999) Lancet , vol.353 , Issue.9168 , pp. 1930-1933
    • Phillips, M.1    Gleeson, K.2    Hughes, J.M.B.3    Greenberg, J.4    Cataneo, R.N.5    Baker, L.6    McVay, W.P.7
  • 24
    • 62349108351 scopus 로고    scopus 로고
    • On the use of Tedlar (R) bags for breath-gas sampling and analysis
    • 1752-7155 046001
    • Beauchamp J, Herbig J, Gutmann R and Hansel A 2008 On the use of Tedlar (R) bags for breath-gas sampling and analysis J. Breath Res. 2 046001
    • (2008) J. Breath Res. , vol.2
    • Beauchamp, J.1    Herbig, J.2    Gutmann, R.3    Hansel, A.4
  • 25
    • 34247866471 scopus 로고    scopus 로고
    • An off-line breath sampling and analysis method suitable for large screening studies
    • DOI 10.1088/0967-3334/28/5/005, PII S0967333407349265
    • Steeghs M M L, Cristescu S M, Munnik P, Zanen P and Harren F J M 2007 An off-line breath sampling and analysis method suitable for large screening studies Physiol. Meas. 28 503-14 (Pubitemid 46691079)
    • (2007) Physiological Measurement , vol.28 , Issue.5 , pp. 005
    • Steeghs, M.M.L.1    Cristescu, S.M.2    Munnik, P.3    Zanen, P.4    Harren, F.J.M.5
  • 26
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • DOI 10.2337/diacare.28.5.1231
    • Klonoff D C 2005 Continuous glucose monitoring - roadmap for 21st century diabetes therapy Diabetes Care 28 1231-39 (Pubitemid 40616646)
    • (2005) Diabetes Care , vol.28 , Issue.5 , pp. 1231-1239
    • Klonoff, D.C.1
  • 27
    • 76649112772 scopus 로고    scopus 로고
    • Breath acetone concentration decreases with blood glucose concentration in type i diabetes mellitus patients during hypoglycaemic clamps
    • 1752-7155 046004
    • Turner C, Walton C, Hoashi S and Evans M 2009 Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps J. Breath Res. 3 046004
    • (2009) J. Breath Res. , vol.3
    • Turner, C.1    Walton, C.2    Hoashi, S.3    Evans, M.4
  • 29
    • 67650076217 scopus 로고    scopus 로고
    • Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds
    • 10.1152/japplphysiol.91657.2008 8750-7587
    • Lee J, Ngo J, Blake D, Meinardi S, Pontello A M, Newcomb R and Galassetti P R 2009 Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds J. Appl. Physiol. 107 155-60
    • (2009) J. Appl. Physiol. , vol.107 , Issue.1 , pp. 155-160
    • Lee, J.1    Ngo, J.2    Blake, D.3    Meinardi, S.4    Pontello, A.M.5    Newcomb, R.6    Galassetti, P.R.7
  • 32
    • 77952880920 scopus 로고    scopus 로고
    • High resolution PTR-TOF: Quantification and formula confirmation of VOC in real time
    • 10.1016/j.jasms.2010.02.006 1044-0305
    • Graus M, Muller M and Hansel A 2010 High resolution PTR-TOF: quantification and formula confirmation of VOC in real time J. Am. Soc. Mass Spectrom. 21 1037-44
    • (2010) J. Am. Soc. Mass Spectrom. , vol.21 , Issue.6 , pp. 1037-1044
    • Graus, M.1    Muller, M.2    Hansel, A.3
  • 33
    • 84875141049 scopus 로고    scopus 로고
    • Comparison of different real time VOC measurement techniques in a ponderosa pine forest
    • 10.5194/acp-13-2893-2013 1680-7324
    • Kaser L et al 2013 Comparison of different real time VOC measurement techniques in a ponderosa pine forest Atmos. Chem. Phys. 13 2893-906
    • (2013) Atmos. Chem. Phys. , vol.13 , Issue.5 , pp. 2893-2906
    • Kaser, L.1
  • 34
    • 43549115501 scopus 로고    scopus 로고
    • Characterizing glucose exposure for individuals with normal glucose tolerance using continuous glucose monitoring and ambulatory glucose profile analysis
    • DOI 10.1089/dia.2007.0293
    • Mazze R S, Strock E, Wesley D, Borgman S, Morgan B, Bergenstal R and Cuddihy R 2008 Characterizing glucose exposure for individuals with normal glucose tolerance using continuous glucose monitoring and ambulatory glucose profile analysis Diabetes Technol. Ther. 10 149-59 (Pubitemid 351677595)
    • (2008) Diabetes Technology and Therapeutics , vol.10 , Issue.3 , pp. 149-159
    • Mazze, R.S.1    Strock, E.2    Wesley, D.3    Borgman, S.4    Morgan, B.5    Bergenstal, R.6    Cuddihy, R.7
  • 36
    • 0015425965 scopus 로고
    • Day-to-day variation of continuously monitored glycemia - Further measure of diabetic instability
    • 10.1007/BF01218495 0012-186X
    • Molnar G D, Taylor W F and Ho M M 1972 Day-to-day variation of continuously monitored glycemia - further measure of diabetic instability Diabetologia 8 342-8
    • (1972) Diabetologia , vol.8 , Issue.5 , pp. 342-348
    • Molnar, G.D.1    Taylor, W.F.2    Ho, M.M.3
  • 37
    • 0014095480 scopus 로고
    • Plasma insulin response to glucose infusion in healthy subjects and in diabetes mellitus
    • 0001-5598
    • Cerasi E and Luft R 1967 Plasma insulin response to glucose infusion in healthy subjects and in diabetes mellitus Acta Endocrinol. 55 278-304
    • (1967) Acta Endocrinol. , vol.55 , pp. 278-304
    • Cerasi, E.1    Luft, R.2
  • 38
    • 84871995815 scopus 로고    scopus 로고
    • Standards of medical care in diabetes-2013
    • 10.2337/dc13-S011 0149-5992
    • American Diabetes Association 2013 Standards of medical care in diabetes-2013 Diabetes Care 36 S11-66
    • (2013) Diabetes Care , vol.36 , Issue.SUPPL. 1
  • 41
    • 33747781180 scopus 로고    scopus 로고
    • Sample water removal method in volatile organic compound analysis based on diffusion through poly(vinyl fluoride) film
    • DOI 10.1016/j.chroma.2006.05.102, PII S0021967306010983
    • Beghi S and Guillot J M 2006 Sample water removal method in volatile organic compound analysis based on diffusion through poly(vinyl fluoride) film J. Chromatogr. A 1127 1-5 (Pubitemid 44278821)
    • (2006) Journal of Chromatography A , vol.1127 , Issue.1-2 , pp. 1-5
    • Beghi, S.1    Guillot, J.-M.2
  • 43
    • 0027250730 scopus 로고
    • Effect of regulating cholesterol biosynthesis on breath isoprene excretion in men
    • Stone B G, Besse T J, Duane W C, Evans C D and Demaster E G 1993 Effect of regulating cholesterol-biosynthesis on breath isoprene excretion in men Lipids 28 705-8 (Pubitemid 23241435)
    • (1993) Lipids , vol.28 , Issue.8 , pp. 705-708
    • Stone, B.G.1    Besse, T.J.2    Duane, W.C.3    Evans, C.D.4    DeMaster, E.G.5
  • 44
    • 84886595668 scopus 로고
    • Significance testing of Spearman rank correlation coefficient
    • 10.1080/01621459.1972.10481251 0162-1459
    • Zar J H 1972 Significance testing of Spearman rank correlation coefficient J. Am. Stat. Assoc. 67 578-80
    • (1972) J. Am. Stat. Assoc. , vol.67 , Issue.339 , pp. 578-580
    • Zar, J.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.