Experience with DC polarization-depolarization measurements on stator winding insulation

Author keywords

depolarization currents; polarization currents; stator windine insulation

Indexed keywords

DEPOLARIZATION CURRENTS; DISCHARGING CURRENT; DISSIPATION FACTORS; INSULATION RESISTANCE; PARTIAL DISCHARGE TESTS; POLARIZATION CURRENT; POLARIZATION INDICES; POLARIZATION/DEPOLARIZATION CURRENT;

EID: 84883818614     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EIC.2013.6554191     Document Type: Conference Paper
Times cited : (11)

References (13)
  • 6
    • 33646398368 scopus 로고    scopus 로고
    • Dielectric response studies on insulating systems of rotating machines
    • Feb
    • M. Farahani et al, "Dielectric Response Studies on Insulating Systems of Rotating Machines", Trans DEI, Feb 2006, pp 383-393.
    • (2006) Trans DEI , pp. 383-393
    • Farahani, M.1
  • 7
    • 70449640303 scopus 로고    scopus 로고
    • Field experience in insulation diagnosis of industrial hv motors using dielectric response technique
    • May
    • S. Bhumiwat, "Field Experience in Insulation Diagnosis of Industrial HV Motors Using Dielectric Response Technique", in Proc IEEE Electrical Insulation Conference, May 2009, pp 454-459.
    • (2009) Proc IEEE Electrical Insulation Conference , pp. 454-459
    • Bhumiwat, S.1
  • 8
    • 34249715253 scopus 로고    scopus 로고
    • Condition assessment of rotating machine winding insulation by analysis of charging and discharging currents
    • G. R. Soltani, E. David, "Condition Assessment of Rotating Machine Winding Insulation by Analysis of Charging and Discharging Currents", in Proc IEEE International Symposium on Electrical Insulation 2006, pp 336-339.
    • (2006) Proc IEEE International Symposium on Electrical Insulation , pp. 336-339
    • Soltani, G.R.1    David, E.2
  • 9
    • 70449652305 scopus 로고    scopus 로고
    • Stator winding hipot (High Potential) testing
    • Montreal, June
    • B. K. Gupta, et al, "Stator Winding Hipot (High Potential) Testing", in Proc IEEE Electrical Insulation Conference, Montreal, June 2009.
    • (2009) Proc IEEE Electrical Insulation Conference
    • Gupta, B.K.1
  • 11
    • 32144442689 scopus 로고    scopus 로고
    • Objective methods to interpret PD data on rotating machine stator windings
    • Jan
    • G. C. Stone, V. Warren, "Objective Methods to Interpret PD Data on Rotating machine Stator Windings, IEEE Trans IA, Jan 2006, pp 195-200.
    • (2006) IEEE Trans IA , pp. 195-200
    • Stone, G.C.1    Warren, V.2
  • 12
    • 14844298673 scopus 로고    scopus 로고
    • High voltage DC ramp testing as a diagnostic of stator insulation condition
    • Sept
    • H. G. Sedding et al, "High voltage DC ramp testing as a diagnostic of stator insulation condition", in Proc IEEE International Symposium on Electrical Insulation, Sept 2004, pp 430-433.
    • (2004) Proc IEEE International Symposium on Electrical Insulation , pp. 430-433
    • Sedding, H.G.1
  • 13
    • 77958051215 scopus 로고    scopus 로고
    • Relevance of phase resolved PD analysis to insulation diagnosis on industrial equipment
    • Germany, July
    • G. C. Stone, "Relevance of Phase Resolved PD Analysis to Insulation Diagnosis on Industrial Equipment", in Proc IEEE International Conference on Solid Dielectrics, Germany, July 2010.
    • (2010) Proc IEEE International Conference on Solid Dielectrics
    • Stone, G.C.1