메뉴 건너뛰기




Volumn 2007, Issue , 2007, Pages 336-339

Condition assessment of rotating machine winding insulation by analysis of charging and discharging currents

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC INSULATION; PARTIAL DISCHARGES; POLARIZATION; ROTATING MACHINERY; TURBOGENERATORS;

EID: 34249715253     PISSN: 01642006     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (14)

References (5)
  • 1
    • 34249749515 scopus 로고    scopus 로고
    • Recommended practice for testing insulation resistance of rotating machinery
    • IEEE Std. 43-2000, "Recommended practice for testing insulation resistance of rotating machinery"
    • IEEE Std1
  • 2
    • 22744445648 scopus 로고    scopus 로고
    • Detecting delaminated stator winding insulation using the ramped high-voltage DC test methods
    • Aug
    • L.M. Rux and S. Grzybowski, "Detecting delaminated stator winding insulation using the ramped high-voltage DC test methods", High Voltage Engineering Symposium, Aug. 1999
    • (1999) High Voltage Engineering Symposium
    • Rux, L.M.1    Grzybowski, S.2
  • 3
    • 0036082085 scopus 로고    scopus 로고
    • The use of time domain spectroscopy as a diagnostic tool for rotating machine windings
    • April
    • E.David, L.Lamarre, D.N.Nguyen, "The use of time domain spectroscopy as a diagnostic tool for rotating machine windings", International Symposium on Electrical Insulation, pp.506-510, April 2002.
    • (2002) International Symposium on Electrical Insulation , pp. 506-510
    • David, E.1    Lamarre, L.2    Nguyen, D.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.