메뉴 건너뛰기




Volumn 4191 LNCS - II, Issue , 2006, Pages 144-151

Automated analysis of multi site MRI phantom data for the NIHPD project

Author keywords

[No Author keywords available]

Indexed keywords

DATA REDUCTION; PROJECT MANAGEMENT; SIGNAL TO NOISE RATIO;

EID: 84883777300     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/11866763_18     Document Type: Conference Paper
Times cited : (23)

References (14)
  • 1
    • 0036853443 scopus 로고    scopus 로고
    • Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation
    • November
    • Mah D., Steckner M., Palacio E., Mitra R., Richardson T., Hanks G.E.: Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation. Medical Physics, Vol. 29(11):2541-2547, November 2002
    • (2002) Medical Physics , vol.29 , Issue.11 , pp. 2541-2547
    • Mah, D.1    Steckner, M.2    Palacio, E.3    Mitra, R.4    Richardson, T.5    Hanks, G.E.6
  • 2
    • 0034183726 scopus 로고    scopus 로고
    • Signal intensity artifacts in clinical MR imaging
    • May-June
    • Jones R.W., Witte R.F.: Signal intensity artifacts in clinical MR imaging. Radiographics Vol. 20(3):893-901, May-June 2000.
    • (2000) Radiographics , vol.20 , Issue.3 , pp. 893-901
    • Jones, R.W.1    Witte, R.F.2
  • 3
    • 0031859144 scopus 로고    scopus 로고
    • Measurement of small inter-scan fluctuations in voxel dimensions in magnetic resonance images using registration
    • June
    • Lemieux L., Barker G.J.: Measurement of small inter-scan fluctuations in voxel dimensions in magnetic resonance images using registration. Medical Physics, Vol. 25(6): 1049-1054, June 1998.
    • (1998) Medical Physics , vol.25 , Issue.6 , pp. 1049-1054
    • Lemieux, L.1    Barker, G.J.2
  • 5
    • 32644441220 scopus 로고    scopus 로고
    • Brain Development Cooperative Group: The NIH MRI study of normal brain development
    • March
    • Evans A.C., Brain Development Cooperative Group: The NIH MRI study of normal brain development. Neurolmage, Vol. 30(1): 184-202, March 2006.
    • (2006) Neurolmage , vol.30 , Issue.1 , pp. 184-202
    • Evans, A.C.1
  • 7
    • 13844297663 scopus 로고    scopus 로고
    • Quality assurance of clinical MRI scanners using ACR MRI phantom: Preliminary results
    • December
    • Chen C.C., Wan Y.L., Wai Y.Y., Liu H.L.: Quality Assurance of Clinical MRI Scanners Using ACR MRI Phantom: Preliminary Results. Journal of Digital Imaging, Vol. 17(4):279-284, December 2004.
    • (2004) Journal of Digital Imaging , vol.17 , Issue.4 , pp. 279-284
    • Chen, C.C.1    Wan, Y.L.2    Wai, Y.Y.3    Liu, H.L.4
  • 9
    • 0033430135 scopus 로고    scopus 로고
    • Automatic quality assessment protocol for MRI equipment
    • December
    • Bourel P., Gibon D., Coste E., Daanen V., Rousseau J.: Automatic quality assessment protocol for MRI equipment. Medical Physics, Vol. 26(12), December 1999:2693-2700.
    • (1999) Medical Physics , vol.26 , Issue.12 , pp. 2693-2700
    • Bourel, P.1    Gibon, D.2    Coste, E.3    Daanen, V.4    Rousseau, J.5
  • 12
    • 0001059981 scopus 로고    scopus 로고
    • The MINC file format: From bytes to brains
    • Neelin P.: The MINC File Format: From Bytes to Brains. NeuroImage, Vol. 7(4), 1998.
    • (1998) NeuroImage , vol.7 , Issue.4
    • Neelin, P.1
  • 13
    • 0033857047 scopus 로고    scopus 로고
    • Image analysis methods for assessing levels of image plane nonuniformity and stochastic noise in a magnetic resonance image of a homogeneous phantom
    • August
    • Magnusson P., Olson L. E.: Image analysis methods for assessing levels of image plane nonuniformity and stochastic noise in a magnetic resonance image of a homogeneous phantom. Medical Physics, Vol. 27(8): 1980-1994, August 2000.
    • (2000) Medical Physics , vol.27 , Issue.8 , pp. 1980-1994
    • Magnusson, P.1    Olson, L.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.