-
1
-
-
84865278119
-
Heart rhythm society task force on catheter and surgical ablation of atrial fibrillation: 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design
-
Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, Crijns HJ, Damiano RJ Jr, Davies DW, DiMarco J, Edgerton J, Ellenbogen K, Ezekowitz MD, Haines DE, Haissaguerre M, Hindricks G, Iesaka Y, Jackman W, Jalife J, Jais P, Kalman J, Keane D, Kim YH, Kirchhof P, Klein G, Kottkamp H, Kumagai K, Lindsay BD, Mansour M, Marchlinski FE, McCarthy PM, Mont JL, Morady F, Nademanee K, Nakagawa H, Natale A, Nattel S, Packer DL, Pappone C, Prystowsky E, Raviele A, Reddy V, Ruskin JN, Shemin RJ, Tsao HM, Wilber D,; Heart rhythm society task force on catheter and surgical ablation of atrial fibrillation: 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Heart Rhythm 2012; 9: 632-696.
-
(2012)
Heart Rhythm
, vol.9
, pp. 632-696
-
-
Calkins, H.1
Kuck, K.H.2
Cappato, R.3
Brugada, J.4
Camm, A.J.5
Chen, S.A.6
Crijns, H.J.7
Damiano, Jr.R.J.8
Davies, D.W.9
Dimarco, J.10
Edgerton, J.11
Ellenbogen, K.12
Ezekowitz, M.D.13
Haines, D.E.14
Haissaguerre, M.15
Hindricks, G.16
Iesaka, Y.17
Jackman, W.18
Jalife, J.19
Jais, P.20
Kalman, J.21
Keane, D.22
Kim, Y.H.23
Kirchhof, P.24
Klein, G.25
Kottkamp, H.26
Kumagai, K.27
Lindsay, B.D.28
Mansour, M.29
Marchlinski, F.E.30
McCarthy, P.M.31
Mont, J.L.32
Morady, F.33
Nademanee, K.34
Nakagawa, H.35
Natale, A.36
Nattel, S.37
Packer, D.L.38
Pappone, C.39
Prystowsky, E.40
Raviele, A.41
Reddy, V.42
Ruskin, J.N.43
Shemin, R.J.44
Tsao, H.M.45
Wilber, D.46
more..
-
2
-
-
77951884938
-
Damage to the esophagus after atrial fibrillation ablation: Just the tip of the iceberb? High prevalence of mediastinal changes diagnosed by endosonography
-
Zellerhoff S, Ullerich H, Lenze F, Meister T, Wasmer K, Mönnig G, Köbe J, Milberg P, Bittner A, Domschke W, Breithardt G, Eckardt L,: Damage to the esophagus after atrial fibrillation ablation: Just the tip of the iceberb? High prevalence of mediastinal changes diagnosed by endosonography. Circ Arrhythm Electrophysiol 2010; 3: 155-159.
-
(2010)
Circ Arrhythm Electrophysiol
, vol.3
, pp. 155-159
-
-
Zellerhoff, S.1
Ullerich, H.2
Lenze, F.3
Meister, T.4
Wasmer, K.5
Mönnig, G.6
Köbe, J.7
Milberg, P.8
Bittner, A.9
Domschke, W.10
Breithardt, G.11
Eckardt, L.12
-
3
-
-
20844438328
-
Computed tomographic analysis of the anatomy of the left atrium and the esophagus: Implications for left atrial catheter ablation
-
Lemola K, Sneider M, Desjardins B, Case I, Han J, Good E, Tamirisa K, Tsemo A, Chugh A, Bogun F, Pelosi F Jr, Kazerooni E, Morady F, Oral H,: Computed tomographic analysis of the anatomy of the left atrium and the esophagus: Implications for left atrial catheter ablation. Circulation 2004; 110: 3655-3660.
-
(2004)
Circulation
, vol.110
, pp. 3655-3660
-
-
Lemola, K.1
Sneider, M.2
Desjardins, B.3
Case, I.4
Han, J.5
Good, E.6
Tamirisa, K.7
Tsemo, A.8
Chugh, A.9
Bogun, F.10
Pelosi, Jr.F.11
Kazerooni, E.12
Morady, F.13
Oral, H.14
-
4
-
-
79958816503
-
Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: Results of a pilot study
-
Leite LR, Santos SN, Maia H, Henz BD, Giuseppin F, Oliverira A, Zanatta AR, Peres AK, Novakoski C, Barreto JR, Vassalo F, d'Avila A, Singh SM,: Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: Results of a pilot study. Circ Arrhythm Electrophysiol 2011; 4: 149-156.
-
(2011)
Circ Arrhythm Electrophysiol
, vol.4
, pp. 149-156
-
-
Leite, L.R.1
Santos, S.N.2
Maia, H.3
Henz, B.D.4
Giuseppin, F.5
Oliverira, A.6
Zanatta, A.R.7
Peres, A.K.8
Novakoski, C.9
Barreto, J.R.10
Vassalo, F.11
D'Avila, A.12
Singh, S.M.13
-
5
-
-
79957706725
-
Prevalence and characteristics of asymptomatic excessive transmural injury after radiofrequency catheter ablation of atrial fibrillation
-
Yamasaki H, Tada H, Sekiguchi Y, Igarashi M, Arimoto T, Machino T, Ozawa M, Naruse Y, Kuroki K, Tsuneoka H, Ito Y, Murakoshi N, Kuga K, Hyodo I, Aonuma K,: Prevalence and characteristics of asymptomatic excessive transmural injury after radiofrequency catheter ablation of atrial fibrillation. Heart Rhythm 2011; 8: 826-832.
-
(2011)
Heart Rhythm
, vol.8
, pp. 826-832
-
-
Yamasaki, H.1
Tada, H.2
Sekiguchi, Y.3
Igarashi, M.4
Arimoto, T.5
Machino, T.6
Ozawa, M.7
Naruse, Y.8
Kuroki, K.9
Tsuneoka, H.10
Ito, Y.11
Murakoshi, N.12
Kuga, K.13
Hyodo, I.14
Aonuma, K.15
-
6
-
-
41949089867
-
Incidence of oesophageal wall injury post-pulmonary vein atrum isolation for treatment of patients with atrial fibrillation
-
Schmidt M, Nölker G, Marschang H, Gutleben KJ, Schibgilla V, Rittger H, Sinha AM, Ritscher G, Mayer D, Brachmann J, Marrouche NF,: Incidence of oesophageal wall injury post-pulmonary vein atrum isolation for treatment of patients with atrial fibrillation. Eurospace 2008; 10: 205-209.
-
(2008)
Eurospace
, vol.10
, pp. 205-209
-
-
Schmidt, M.1
Nölker, G.2
Marschang, H.3
Gutleben, K.J.4
Schibgilla, V.5
Rittger, H.6
Sinha, A.M.7
Ritscher, G.8
Mayer, D.9
Brachmann, J.10
Marrouche, N.F.11
-
7
-
-
77955243893
-
Unexpected high incidence of esophageal injury following pulmonary vein isolation using robotic navigation
-
Tilz RR, Chun KR, Metzner A, Burchard A, Wissner E, Koektuerk B, Konstantinidou M, Nuyens D, De Potter T, Neven K, Fürnkranz A, Ouyang F, Schmidt B,: Unexpected high incidence of esophageal injury following pulmonary vein isolation using robotic navigation. J Cardiovasc Electrophysiol 2010; 21: 853-858.
-
(2010)
J Cardiovasc Electrophysiol
, vol.21
, pp. 853-858
-
-
Tilz, R.R.1
Chun, K.R.2
Metzner, A.3
Burchard, A.4
Wissner, E.5
Koektuerk, B.6
Konstantinidou, M.7
Nuyens, D.8
De Potter, T.9
Neven, K.10
Fürnkranz, A.11
Ouyang, F.12
Schmidt, B.13
-
8
-
-
77949275782
-
Thermal esophageal lesions after radiofrequency catheter ablation of left atrial arrhythmias
-
Halm U, Gaspar T, Zachäus M, Sack S, Arya A, Piorkowski C, Knigge I, Hindricks G, Husser D,: Thermal esophageal lesions after radiofrequency catheter ablation of left atrial arrhythmias. Am J Gastroenterol 2010; 105: 551-556.
-
(2010)
Am J Gastroenterol
, vol.105
, pp. 551-556
-
-
Halm, U.1
Gaspar, T.2
Zachäus, M.3
Sack, S.4
Arya, A.5
Piorkowski, C.6
Knigge, I.7
Hindricks, G.8
Husser, D.9
-
9
-
-
67549085521
-
Esophageal damage during radiofrequency ablation of atrial fibrillation: Impact of energy settings, lesion sets, and esophageal visualization
-
Martinek M, Bencsik G, Aichinger J, Hassanein S, Schoefl R, Kuchinka P, Nesser HJ, Purerfellner H,: Esophageal damage during radiofrequency ablation of atrial fibrillation: Impact of energy settings, lesion sets, and esophageal visualization. J Cardiovasc Electrophysiol 2009; 20: 726-733.
-
(2009)
J Cardiovasc Electrophysiol
, vol.20
, pp. 726-733
-
-
Martinek, M.1
Bencsik, G.2
Aichinger, J.3
Hassanein, S.4
Schoefl, R.5
Kuchinka, P.6
Nesser, H.J.7
Purerfellner, H.8
-
10
-
-
65349092957
-
Esophageal injury and temperature monitoring during atrial fibrillation ablation
-
Singh SM, d'Avila A, Doshi SK, Brugge WR, Bedford RA, Mela T, Ruskin JN, Reddy VY,: Esophageal injury and temperature monitoring during atrial fibrillation ablation. Circ Arrhythm Electrophysiol 2008; 1: 162-168.
-
(2008)
Circ Arrhythm Electrophysiol
, vol.1
, pp. 162-168
-
-
Singh, S.M.1
D'Avila, A.2
Doshi, S.K.3
Brugge, W.R.4
Bedford, R.A.5
Mela, T.6
Ruskin, J.N.7
Reddy, V.Y.8
-
11
-
-
4444229385
-
Left atrial-esophageal fistula following radiofrequency catheter ablation
-
Scanavacca MI, D'Avila A, Parga J, Sosa E,: Left atrial-esophageal fistula following radiofrequency catheter ablation. J Cardiovasc Electrophysiol 2004; 15: 960-962.
-
(2004)
J Cardiovasc Electrophysiol
, vol.15
, pp. 960-962
-
-
Scanavacca, M.I.1
D'Avila, A.2
Parga, J.3
Sosa, E.4
-
12
-
-
69249170000
-
Complications of atrial fibrillation ablation in a high-volume center in 1,000 procedures: Still cause for concern?
-
Dagres N, Hindricks G, Kottkamp H, Sommer P, Gaspar T, Bode K, Arya A, Husser D, Rallidis LS, Kremastinos DT, Piorkowski C,: Complications of atrial fibrillation ablation in a high-volume center in 1,000 procedures: Still cause for concern? J Cardiovasc Electrophysiol 2009; 20: 1014-1019.
-
(2009)
J Cardiovasc Electrophysiol
, vol.20
, pp. 1014-1019
-
-
Dagres, N.1
Hindricks, G.2
Kottkamp, H.3
Sommer, P.4
Gaspar, T.5
Bode, K.6
Arya, A.7
Husser, D.8
Rallidis, L.S.9
Kremastinos, D.T.10
Piorkowski, C.11
-
13
-
-
59449098640
-
A nationwide survey on the prevalence of atrio-esophageal fistula after left atrial radiofrequency ablation
-
Ghia KK, Chugh A, Good E, Pelosi F, Jongnarangsin K, Bogun F, Morady F, Oral H,: A nationwide survey on the prevalence of atrio-esophageal fistula after left atrial radiofrequency ablation. J Interv Card Electrophysiol 2009; 24: 33-36.
-
(2009)
J Interv Card Electrophysiol
, vol.24
, pp. 33-36
-
-
Ghia, K.K.1
Chugh, A.2
Good, E.3
Pelosi, F.4
Jongnarangsin, K.5
Bogun, F.6
Morady, F.7
Oral, H.8
-
14
-
-
23044477164
-
Assessment of temperature, proximity, and course of the esophagus during radiofrequency ablation within the left atrium
-
Cummings JE, Schweikert RA, Saliba WI, Burkhardt JD, Brachmann J, Gunther J, Schibgilla V, Verma A, Dery M, Drago JL, Kilicaslan F, Natale A,: Assessment of temperature, proximity, and course of the esophagus during radiofrequency ablation within the left atrium. Circulation 2005; 112: 459-464.
-
(2005)
Circulation
, vol.112
, pp. 459-464
-
-
Cummings, J.E.1
Schweikert, R.A.2
Saliba, W.I.3
Burkhardt, J.D.4
Brachmann, J.5
Gunther, J.6
Schibgilla, V.7
Verma, A.8
Dery, M.9
Drago, J.L.10
Kilicaslan, F.11
Natale, A.12
-
15
-
-
84857030787
-
Mechanical esophageal displacement during catheter ablation for atrial fibrillation
-
Koruth JS, Reddy VY, Miller MA, Patel KK, Coffey JO, Fischer A, Gomes JA, Dukkipati S, D'Avila A, Mittnacht A,: Mechanical esophageal displacement during catheter ablation for atrial fibrillation. J Cardiovasc Electrophysiol 2012; 23: 147-154.
-
(2012)
J Cardiovasc Electrophysiol
, vol.23
, pp. 147-154
-
-
Koruth, J.S.1
Reddy, V.Y.2
Miller, M.A.3
Patel, K.K.4
Coffey, J.O.5
Fischer, A.6
Gomes, J.A.7
Dukkipati, S.8
D'Avila, A.9
Mittnacht, A.10
-
16
-
-
33846361056
-
Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: A pilot study
-
Tsuchiya T, Ashikaga K, Nakagawa S, Hayashida K, Kugimiya H,: Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: A pilot study. J Cardiovasc Electrophysiol 2007; 18: 145-150.
-
(2007)
J Cardiovasc Electrophysiol
, vol.18
, pp. 145-150
-
-
Tsuchiya, T.1
Ashikaga, K.2
Nakagawa, S.3
Hayashida, K.4
Kugimiya, H.5
-
17
-
-
28244462488
-
Movement of the esophagus during left atrial catheter ablation for atrial fibrillation
-
Good E, Oral H, Lemola K, Han J, Tamirisa K, Igic P, Elmouchi D, Tschopp D, Reich S, Chugh A, Bogun F, Pelosi F Jr, Morady F,: Movement of the esophagus during left atrial catheter ablation for atrial fibrillation. J Am Coll Cardiol 2005; 46: 2107-2110.
-
(2005)
J Am Coll Cardiol
, vol.46
, pp. 2107-2110
-
-
Good, E.1
Oral, H.2
Lemola, K.3
Han, J.4
Tamirisa, K.5
Igic, P.6
Elmouchi, D.7
Tschopp, D.8
Reich, S.9
Chugh, A.10
Bogun, F.11
Pelosi, Jr.F.12
Morady, F.13
-
18
-
-
82455175259
-
Severity of esophageal injury predicts time to healing after radiofrequency catheter ablation for atrial fibrillation
-
Contreras-Valdes FM, Heist EK, Danik SB, Barrett CD, Blendea D, Brugge WR, Ptaszek L, Ruskin JN, Mansour M,: Severity of esophageal injury predicts time to healing after radiofrequency catheter ablation for atrial fibrillation. Heart Rhythm 2011; 8: 1862-1868.
-
(2011)
Heart Rhythm
, vol.8
, pp. 1862-1868
-
-
Contreras-Valdes, F.M.1
Heist, E.K.2
Danik, S.B.3
Barrett, C.D.4
Blendea, D.5
Brugge, W.R.6
Ptaszek, L.7
Ruskin, J.N.8
Mansour, M.9
-
19
-
-
79952512982
-
Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation
-
Deneke T, Bünz K, Bastian A, Päsler M, Anders H, Lehmann R, Meuser W, de Groot JR, Horlitz M, Haberkorn R, Mügge A, Shin DI,: Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation. J Cardiovasc Electrophysiol 2011; 22: 255-261.
-
(2011)
J Cardiovasc Electrophysiol
, vol.22
, pp. 255-261
-
-
Deneke, T.1
Bünz, K.2
Bastian, A.3
Päsler, M.4
Anders, H.5
Lehmann, R.6
Meuser, W.7
De Groot, J.R.8
Horlitz, M.9
Haberkorn, R.10
Mügge, A.11
Shin, D.I.12
-
20
-
-
79957773102
-
Esophageal temperature change and esophageal thermal lesions after pulmonary vein isolation using the novel endoscopic ablation system
-
Metzner A, Schmidt B, Fuernkranz A, Wissner E, Tilz RR, Koester I, Konstantinidou M, Rillig A, Yoshiga Y, Mathew S, Ouyang F, Kuck KH,: Esophageal temperature change and esophageal thermal lesions after pulmonary vein isolation using the novel endoscopic ablation system. Heart Rhythm 2011; 8: 815-820.
-
(2011)
Heart Rhythm
, vol.8
, pp. 815-820
-
-
Metzner, A.1
Schmidt, B.2
Fuernkranz, A.3
Wissner, E.4
Tilz, R.R.5
Koester, I.6
Konstantinidou, M.7
Rillig, A.8
Yoshiga, Y.9
Mathew, S.10
Ouyang, F.11
Kuck, K.H.12
-
21
-
-
45149095735
-
Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: Comparison between 8 mm tip and open irrigation catheters
-
Cummings JE, Barrett CD, Litwak KN, DI Biase L, Chowdhury P, Oh S, Ching CK, Saliba WI, Schweikert RA, Burkhardt JD, DE Marco S, Armaganijan L, Natale A,: Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: Comparison between 8 mm tip and open irrigation catheters. J Cardiovasc Electrophysiol 2008; 19: 641-644.
-
(2008)
J Cardiovasc Electrophysiol
, vol.19
, pp. 641-644
-
-
Cummings, J.E.1
Barrett, C.D.2
Litwak, K.N.3
Di Biase, L.4
Chowdhury, P.5
Oh, S.6
Ching, C.K.7
Saliba, W.I.8
Schweikert, R.A.9
Burkhardt, J.D.10
De Marco, S.11
Armaganijan, L.12
Natale, A.13
-
22
-
-
20444423813
-
Esophageal temperature monitoring during radiofrequency ablation of atrial fibrillation
-
Redfearn DP, Trim GM, Skanes AC, Petrellis B, Krahn AD, Yee R, Klein GJ,: Esophageal temperature monitoring during radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol 2005; 16: 589-593.
-
(2005)
J Cardiovasc Electrophysiol
, vol.16
, pp. 589-593
-
-
Redfearn, D.P.1
Trim, G.M.2
Skanes, A.C.3
Petrellis, B.4
Krahn, A.D.5
Yee, R.6
Klein, G.J.7
-
23
-
-
27944436105
-
Ablation of atrial fibrillation and esophageal injury: Effects of energy source and ablation technique
-
Aupperle H, Doll N, Walther T, Kornherr P, Ullmann C, Schoon HA, Mohr FW,: Ablation of atrial fibrillation and esophageal injury: Effects of energy source and ablation technique. J Thorac Cardiovasc Surg 2005; 130: 1549-1554.
-
(2005)
J Thorac Cardiovasc Surg
, vol.130
, pp. 1549-1554
-
-
Aupperle, H.1
Doll, N.2
Walther, T.3
Kornherr, P.4
Ullmann, C.5
Schoon, H.A.6
Mohr, F.W.7
-
24
-
-
23744437914
-
What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis
-
Berjano EJ, Hornero F,: What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis. Physiol Meas 2005; 26: 837-848.
-
(2005)
Physiol Meas
, vol.26
, pp. 837-848
-
-
Berjano, E.J.1
Hornero, F.2
-
25
-
-
58149117951
-
Safe and effective ablation of atrial fibrillation: Importance of esophageal temperature monitoring to avoid periesophageal nerve injury as a complication of pulmonary vein isolation
-
Kuwahara T, Takahashi A, Kobori A, Miyazaki S, Takahashi Y, Takei A, Nozato T, Hikita H, Sato A, Aonuma K,: Safe and effective ablation of atrial fibrillation: Importance of esophageal temperature monitoring to avoid periesophageal nerve injury as a complication of pulmonary vein isolation. J Cardiovasc Electrophysiol 2009; 20: 1-6.
-
(2009)
J Cardiovasc Electrophysiol
, vol.20
, pp. 1-6
-
-
Kuwahara, T.1
Takahashi, A.2
Kobori, A.3
Miyazaki, S.4
Takahashi, Y.5
Takei, A.6
Nozato, T.7
Hikita, H.8
Sato, A.9
Aonuma, K.10
-
26
-
-
84883818982
-
Canine model of esophageal injury and left atrial-esophageal fistula after pulmonary vein isolation
-
Yokoyama K, Nakagawa H, Seres KA, Jung E, Merino J, Zou Y, Ikeda A, Pitha JV, Lazzara R, Jackman WM,: Canine model of esophageal injury and left atrial-esophageal fistula after pulmonary vein isolation. Circulation 2007; 116 (Suppl II): II-490.
-
(2007)
Circulation
, vol.116
, Issue.SUPPL. II
-
-
Yokoyama, K.1
Nakagawa, H.2
Seres, K.A.3
Jung, E.4
Merino, J.5
Zou, Y.6
Ikeda, A.7
Pitha, J.V.8
Lazzara, R.9
Jackman, W.M.10
-
27
-
-
77955240556
-
Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique
-
Fürnkranz A, Chun KR, Metzner A, Nuyens D, Schmidt B, Burchard A, Tilz R, Ouyang F, Kuck KH,: Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique. J Cardiovasc Electrophysiol 2010; 21: 869-874.
-
(2010)
J Cardiovasc Electrophysiol
, vol.21
, pp. 869-874
-
-
Fürnkranz, A.1
Chun, K.R.2
Metzner, A.3
Nuyens, D.4
Schmidt, B.5
Burchard, A.6
Tilz, R.7
Ouyang, F.8
Kuck, K.H.9
-
28
-
-
77951948055
-
Oesophageal temperature monitoring and incidence of oesophageal lesions after pulmonary vein isolation using a remote robotic navigation system
-
Rillig A, Meyerfeldt U, Birkemeyer R, Wiest S, Sauer BM, Staritz M, Jung W,: Oesophageal temperature monitoring and incidence of oesophageal lesions after pulmonary vein isolation using a remote robotic navigation system. Eurospace 2010; 12: 655-661.
-
(2010)
Eurospace
, vol.12
, pp. 655-661
-
-
Rillig, A.1
Meyerfeldt, U.2
Birkemeyer, R.3
Wiest, S.4
Sauer, B.M.5
Staritz, M.6
Jung, W.7
|