메뉴 건너뛰기




Volumn 24, Issue 9, 2013, Pages 958-964

Multi-sensor esophageal temperature probe used during radiofrequency ablation for atrial fibrillation is associated with increased intraluminal temperature detection and increased risk of esophageal injury compared to single-sensor probe

Author keywords

atrial fibrillation; catheter ablation; complications; electrophysiology; esophageal injury; esophageal temperature monitoring; pulmonary vein isolation

Indexed keywords

ADULT; ARTICLE; CATHETER ABLATION; DISEASE SEVERITY; ENDOSCOPY; ESOPHAGEAL ENDOSCOPY; ESOPHAGUS INJURY; ESOPHAGUS ULCER; FEMALE; HEART ATRIUM FIBRILLATION; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTI SENSOR ESOPHAGEAL TEMPERATURE PROBE; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; SENSOR; SINGLE SENSOR ESOPHAGEAL TEMPERATURE PROBE; TEMPERATURE MEASUREMENT;

EID: 84883754236     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12180     Document Type: Article
Times cited : (64)

References (28)
  • 11
  • 16
    • 33846361056 scopus 로고    scopus 로고
    • Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: A pilot study
    • Tsuchiya T, Ashikaga K, Nakagawa S, Hayashida K, Kugimiya H,: Atrial fibrillation ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: A pilot study. J Cardiovasc Electrophysiol 2007; 18: 145-150.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 145-150
    • Tsuchiya, T.1    Ashikaga, K.2    Nakagawa, S.3    Hayashida, K.4    Kugimiya, H.5
  • 24
    • 23744437914 scopus 로고    scopus 로고
    • What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis
    • Berjano EJ, Hornero F,: What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis. Physiol Meas 2005; 26: 837-848.
    • (2005) Physiol Meas , vol.26 , pp. 837-848
    • Berjano, E.J.1    Hornero, F.2
  • 25
    • 58149117951 scopus 로고    scopus 로고
    • Safe and effective ablation of atrial fibrillation: Importance of esophageal temperature monitoring to avoid periesophageal nerve injury as a complication of pulmonary vein isolation
    • Kuwahara T, Takahashi A, Kobori A, Miyazaki S, Takahashi Y, Takei A, Nozato T, Hikita H, Sato A, Aonuma K,: Safe and effective ablation of atrial fibrillation: Importance of esophageal temperature monitoring to avoid periesophageal nerve injury as a complication of pulmonary vein isolation. J Cardiovasc Electrophysiol 2009; 20: 1-6.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1-6
    • Kuwahara, T.1    Takahashi, A.2    Kobori, A.3    Miyazaki, S.4    Takahashi, Y.5    Takei, A.6    Nozato, T.7    Hikita, H.8    Sato, A.9    Aonuma, K.10
  • 28
    • 77951948055 scopus 로고    scopus 로고
    • Oesophageal temperature monitoring and incidence of oesophageal lesions after pulmonary vein isolation using a remote robotic navigation system
    • Rillig A, Meyerfeldt U, Birkemeyer R, Wiest S, Sauer BM, Staritz M, Jung W,: Oesophageal temperature monitoring and incidence of oesophageal lesions after pulmonary vein isolation using a remote robotic navigation system. Eurospace 2010; 12: 655-661.
    • (2010) Eurospace , vol.12 , pp. 655-661
    • Rillig, A.1    Meyerfeldt, U.2    Birkemeyer, R.3    Wiest, S.4    Sauer, B.M.5    Staritz, M.6    Jung, W.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.