-
1
-
-
70349574028
-
Measurement of individual red blood cell motions under high hematocrit conditions using a confocal micro-PTV system
-
Lima R, Ishikawa T, Imai Y, Takeda M, Wada S, Yamaguchi T. Measurement of individual red blood cell motions under high hematocrit conditions using a confocal micro-PTV system. Annals of Biomedical Engineering 2009; 37:1546-1559.
-
(2009)
Annals of Biomedical Engineering
, vol.37
, pp. 1546-1559
-
-
Lima, R.1
Ishikawa, T.2
Imai, Y.3
Takeda, M.4
Wada, S.5
Yamaguchi, T.6
-
3
-
-
77953115357
-
A three-dimensional particle simulation of the formation and collapse of a primary thrombus
-
Kamada H, Tsubota K, Nakamura M, Wada S, Ishikawa T, Yamaguchi T. A three-dimensional particle simulation of the formation and collapse of a primary thrombus. International Journal for Numerical Methods in Biomedical Engineering 2010; 26:488-500.
-
(2010)
International Journal for Numerical Methods in Biomedical Engineering
, vol.26
, pp. 488-500
-
-
Kamada, H.1
Tsubota, K.2
Nakamura, M.3
Wada, S.4
Ishikawa, T.5
Yamaguchi, T.6
-
4
-
-
36249017571
-
Computational blood flow analysis - new trends and methods
-
Yamaguchi T, Ishikawa T, Tsubota K, Imai Y, Nakamura M, Fukui T. Computational blood flow analysis - new trends and methods. Journal of Biomechanical Science and Enginneering 2006; 1:29-50.
-
(2006)
Journal of Biomechanical Science and Enginneering
, vol.1
, pp. 29-50
-
-
Yamaguchi, T.1
Ishikawa, T.2
Tsubota, K.3
Imai, Y.4
Nakamura, M.5
Fukui, T.6
-
5
-
-
84883655273
-
Confocal micro-PIV/PTV measurements of the blood flow in micro-channels
-
Collins MW, Koenig CS Springer: NewYork
-
Lima R, Ishikawa T, Imai Y, Yamaguchi T. Confocal micro-PIV/PTV measurements of the blood flow in micro-channels. In Nano and Micro Flow Systems for Bioanalysis, Collins MW, Koenig CS (eds). Springer: NewYork, 2012; 131-152.
-
(2012)
Nano and Micro Flow Systems for Bioanalysis
, pp. 131-152
-
-
Lima, R.1
Ishikawa, T.2
Imai, Y.3
Yamaguchi, T.4
-
7
-
-
0023059504
-
Rheological aspects of thrombosis and haemostasis: basic principles and applications. ICTH-Report-Subcommittee on Rheology of the International Committee on Thrombosis and Haemostasis
-
Goldsmith H, Turitto V. Rheological aspects of thrombosis and haemostasis: basic principles and applications. ICTH-Report-Subcommittee on Rheology of the International Committee on Thrombosis and Haemostasis. Journal of Thrombosis and Haemostasis 1986; 55(3):415-435.
-
(1986)
Journal of Thrombosis and Haemostasis
, vol.55
, Issue.3
, pp. 415-435
-
-
Goldsmith, H.1
Turitto, V.2
-
8
-
-
84883653538
-
-
Analysis of the blood flow behavior through microchannels by aconfocal micro-PIV/PTV system. PhD(Eng), Bioengineering and RoboticsDepartment, Tohoku University, Sendai, Japan
-
Lima R. Analysis of the blood flow behavior through microchannels by aconfocal micro-PIV/PTV system. PhD(Eng), Bioengineering and RoboticsDepartment, Tohoku University, Sendai, Japan, 2007.
-
(2007)
-
-
Lima, R.1
-
9
-
-
84882848971
-
Blood flow behavior in microchannels: advances and future trends
-
Dias R, Martins AA, Lima R, Mata TM (eds). Bentham Science Publishers: Netherlands
-
Lima R, Ishikawa T, Imai Y, Yamaguchi T. Blood flow behavior in microchannels: advances and future trends. In Single and two-Phase Flows on Chemical and Biomedical Engineering, Dias R, Martins AA, Lima R, Mata TM (eds). Bentham Science Publishers: Netherlands, 2012; 513-547.
-
(2012)
Single and two-Phase Flows on Chemical and Biomedical Engineering
, pp. 513-547
-
-
Lima, R.1
Ishikawa, T.2
Imai, Y.3
Yamaguchi, T.4
-
11
-
-
24144464290
-
Velocity measurement of both red blood cells and plasma of in vitro blood flow using high-speed micro PIV technique
-
Sugii Y, Okuda R, Okamoto K, Madarame H. Velocity measurement of both red blood cells and plasma of in vitro blood flow using high-speed micro PIV technique. Measurement Science and Technology 2005; 16:1126-1130.
-
(2005)
Measurement Science and Technology
, vol.16
, pp. 1126-1130
-
-
Sugii, Y.1
Okuda, R.2
Okamoto, K.3
Madarame, H.4
-
12
-
-
33646025854
-
In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart
-
Vennemann P, Kiger K, Lindken R, Groenendijk B, Stekelenburg-de Vos S, Hagen T, Ursem N, RPoelmann R, Westerweel J, Hierk B. In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart. Journal of Biomechanics 2006; 39:1191-1200.
-
(2006)
Journal of Biomechanics
, vol.39
, pp. 1191-1200
-
-
Vennemann, P.1
Kiger, K.2
Lindken, R.3
Groenendijk, B.4
Stekelenburg-de Vos, S.5
Hagen, T.6
Ursem, N.7
RPoelmann, R.8
Westerweel, J.9
Hierk, B.10
-
14
-
-
12044260218
-
Particle-imaging techniques for experimental fluid mechanics
-
Adrian R. Particle-imaging techniques for experimental fluid mechanics. Annual Review of Fluid Mechanics 1991; 23:261-304.
-
(1991)
Annual Review of Fluid Mechanics
, vol.23
, pp. 261-304
-
-
Adrian, R.1
-
15
-
-
23044515069
-
Feature point tracking and trajectory analysis for video imaging in cell biology
-
Sbalzarini IF, Koumoutsakos P. Feature point tracking and trajectory analysis for video imaging in cell biology. Journal of Structural Biology 2005; 151(2):182-195.
-
(2005)
Journal of Structural Biology
, vol.151
, Issue.2
, pp. 182-195
-
-
Sbalzarini, I.F.1
Koumoutsakos, P.2
-
16
-
-
33744768636
-
Single particle tracking across sequences of microscopical images: Application to platelet adhesion under flow
-
DOI: 10.1007/s10439-006-9086-8.
-
Machin M, Santomaso A, Mazzucato M, Cozzi MR, Battiston M, Marco L, Canu P. Single particle tracking across sequences of microscopical images: Application to platelet adhesion under flow. Annals of Biomedical Engineering 2006; 34(5):833-846. DOI: 10.1007/s10439-006-9086-8.
-
(2006)
Annals of Biomedical Engineering
, vol.34
, Issue.5
, pp. 833-846
-
-
Machin, M.1
Santomaso, A.2
Mazzucato, M.3
Cozzi, M.R.4
Battiston, M.5
Marco, L.6
Canu, P.7
-
17
-
-
0036354738
-
Brief Communication: Automatic trackingof rolling leukocytes in vivo
-
DOI: 10.1006/mvre.2001.2373.
-
Acton ST, Wethmar K, Ley K. Brief Communication: Automatic trackingof rolling leukocytes in vivo. Microvascular Research 2002; 63:139-148. DOI: 10.1006/mvre.2001.2373.
-
(2002)
Microvascular Research
, vol.63
, pp. 139-148
-
-
Acton, S.T.1
Wethmar, K.2
Ley, K.3
-
18
-
-
33645241605
-
Confocal micro-PIV measurements of three dimensional profiles of cell suspension flow in a square microchannel
-
Lima R, Wada S, Tsubota K, Yamaguchi T. Confocal micro-PIV measurements of three dimensional profiles of cell suspension flow in a square microchannel. Measurement Science and Technology 2006; 17:797-808.
-
(2006)
Measurement Science and Technology
, vol.17
, pp. 797-808
-
-
Lima, R.1
Wada, S.2
Tsubota, K.3
Yamaguchi, T.4
-
19
-
-
34547758445
-
In vitro confocal micro-PIV measurements of blood flow in a square microchannel: the effect of the haematocrit on instantaneous velocity profiles
-
Lima R, Wada S, Takeda M, Tsubota K, Yamaguchi T. In vitro confocal micro-PIV measurements of blood flow in a square microchannel: the effect of the haematocrit on instantaneous velocity profiles. Journal of Biomechanics 2007; 40:2752-2757.
-
(2007)
Journal of Biomechanics
, vol.40
, pp. 2752-2757
-
-
Lima, R.1
Wada, S.2
Takeda, M.3
Tsubota, K.4
Yamaguchi, T.5
-
20
-
-
52649122824
-
Radial dispersion of red blood cells in blood flowing through glass capillaries: role of heamatocrit and geometry
-
Lima R, Ishikawa T, Imai Y, Takeda M, Wada S, Yamaguchi T. Radial dispersion of red blood cells in blood flowing through glass capillaries: role of heamatocrit and geometry. Journal of Biomechanics 2008a; 44:2188-2196.
-
(2008)
Journal of Biomechanics
, vol.44
, pp. 2188-2196
-
-
Lima, R.1
Ishikawa, T.2
Imai, Y.3
Takeda, M.4
Wada, S.5
Yamaguchi, T.6
-
21
-
-
40349096097
-
In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system
-
Lima R, Wada S, Tanaka S, Takeda M, Ishikawa T, Tsubota K, Imai Y, Yamaguchi T. In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system. Biomedical Microdevices 2008b; 10(2):153-167.
-
(2008)
Biomedical Microdevices
, vol.10
, Issue.2
, pp. 153-167
-
-
Lima, R.1
Wada, S.2
Tanaka, S.3
Takeda, M.4
Ishikawa, T.5
Tsubota, K.6
Imai, Y.7
Yamaguchi, T.8
-
22
-
-
77957976765
-
Axisymmetric PDMS microchannels for in vitro haemodynamics studies
-
Lima R, Oliveira MSN, Ishikawa T, Kaji H, Tanaka S, Nishizawa M, Yamaguchi T. Axisymmetric PDMS microchannels for in vitro haemodynamics studies. Biofabrication 2009d; 1(3):035005.
-
(2009)
Biofabrication
, vol.1
, Issue.3
, pp. 035005
-
-
Lima, R.1
Oliveira, M.S.N.2
Ishikawa, T.3
Kaji, H.4
Tanaka, S.5
Nishizawa, M.6
Yamaguchi, T.7
-
23
-
-
64749115421
-
Red blood cell motions in a high hematocrit blood flowing through a stenosed micro-channel
-
Fujiwara H, Ishikawa T, Lima R, Matsuki N, Imai Y, Kaji H, Nishizawa M, Yamaguchi T. Red blood cell motions in a high hematocrit blood flowing through a stenosed micro-channel. Journal of Biomechanics 2009; 42:838-843.
-
(2009)
Journal of Biomechanics
, vol.42
, pp. 838-843
-
-
Fujiwara, H.1
Ishikawa, T.2
Lima, R.3
Matsuki, N.4
Imai, Y.5
Kaji, H.6
Nishizawa, M.7
Yamaguchi, T.8
-
24
-
-
81455144566
-
-
Red blood cell deformation in flows through a PDMS hyperbolic microchannel. Proceedings of TechConnect World 2011 - Microtech Conference and Expo, Boston, MA, USA
-
Yaginuma T, Oliveira MSN, Lima R, Ishikawa T, Yamaguchi T. Red blood cell deformation in flows through a PDMS hyperbolic microchannel. Proceedings of TechConnect World 2011 - Microtech Conference and Expo, Boston, MA, USA, 2011; 2, 505.
-
(2011)
, pp. 2505
-
-
Yaginuma, T.1
Oliveira, M.S.N.2
Lima, R.3
Ishikawa, T.4
Yamaguchi, T.5
-
25
-
-
84856714200
-
-
Flow visualization of trace particles and red blood cells in a microchannel with a diverging and converging bifurcation. ECCOMAS Thematic Conference on Computational Vision and Medical Image Processing, Olhão, Portugal
-
Yaginuma T, Oliveira MSN, Lima R, Dias R, Ishikawa T, Imai Y, Yamaguchi T. Flow visualization of trace particles and red blood cells in a microchannel with a diverging and converging bifurcation. ECCOMAS Thematic Conference on Computational Vision and Medical Image Processing, Olhão, Portugal, 2012; 209-211.
-
(2012)
, pp. 209-211
-
-
Yaginuma, T.1
Oliveira, M.S.N.2
Lima, R.3
Dias, R.4
Ishikawa, T.5
Imai, Y.6
Yamaguchi, T.7
-
26
-
-
84855278516
-
Asymmetry of red blood cell motions in a microchannel with a diverging and converging bifurcation
-
Leble V, Lima R, Dias R, Fernandes C, Ishikawa T, Imai Y, Yamaguchi T. Asymmetry of red blood cell motions in a microchannel with a diverging and converging bifurcation. Biomicrofluidics 2011; 5:044120.
-
(2011)
Biomicrofluidics
, vol.5
, pp. 044120
-
-
Leble, V.1
Lima, R.2
Dias, R.3
Fernandes, C.4
Ishikawa, T.5
Imai, Y.6
Yamaguchi, T.7
-
27
-
-
84964237818
-
Microscale flow dynamics of red blood cells in microchannels: an experimental and numerical analysis
-
Tavares, Jorge (eds).Springer: New York, London
-
Lima R, Fernandes C, Dias R, Ishikawa T, Imai Y, Yamaguchi T. Microscale flow dynamics of red blood cells in microchannels: an experimental and numerical analysis. In Computational Vision and Medical Image Processing: Recent Trends, Vol.19, Tavares, Jorge (eds).Springer: New York, London, 2011; 297-309.
-
(2011)
Computational Vision and Medical Image Processing: Recent Trends
, vol.19
, pp. 297-309
-
-
Lima, R.1
Fernandes, C.2
Dias, R.3
Ishikawa, T.4
Imai, Y.5
Yamaguchi, T.6
-
29
-
-
84883656796
-
-
MatLab. The MathWorks, Inc., version 7.11. Image Processing Toolbox version 7.1 User's guide
-
MatLab. The MathWorks, Inc., version 7.11. Image Processing Toolbox version 7.1 User's guide, 2010.
-
(2010)
-
-
-
30
-
-
35248816828
-
Precise particle tracking against a complicated background: polynomial fitting with Gaussian weight
-
Rogers SS, Zhao TAZ, Lu JR. Precise particle tracking against a complicated background: polynomial fitting with Gaussian weight. Physical Biology 2007; 4:220-222.
-
(2007)
Physical Biology
, vol.4
, pp. 220-222
-
-
Rogers, S.S.1
Zhao, T.A.Z.2
Lu, J.R.3
-
31
-
-
24144437239
-
Tracking single particles: a user-friendly quantitative evaluation
-
Carter BC, Shubeita GT, Gross SP. Tracking single particles: a user-friendly quantitative evaluation. Physical Biology 2005; 2:60-72.
-
(2005)
Physical Biology
, vol.2
, pp. 60-72
-
-
Carter, B.C.1
Shubeita, G.T.2
Gross, S.P.3
-
34
-
-
84883655751
-
-
Region - based spatial and temporal image segmentation. PhD Thesis, Faculdade de Engenharia da Universidadedo Porto
-
Monteiro FJC. Region - based spatial and temporal image segmentation. PhD Thesis, Faculdade de Engenharia da Universidadedo Porto, 2007.
-
(2007)
-
-
Monteiro, F.J.C.1
-
38
-
-
84883657227
-
-
Determination and characterization of red blood cells trajectories: a semi-automatic method. Master in Biomedical Technology, Polytechnic Institute of Bragança, Portugal, in portuguese).
-
Pinho D. Determination and characterization of red blood cells trajectories: a semi-automatic method. Master in Biomedical Technology, Polytechnic Institute of Bragança, Portugal, 2011. (in portuguese).
-
(2011)
-
-
Pinho, D.1
-
40
-
-
33645113436
-
A computer - based for determination of cell-free layer width in microcirculation
-
DOI: 10.1080/10739680600556878.
-
Kim S, Kong RL, Popel AS, Intaglietta M, Jonhson PC. A computer - based for determination of cell-free layer width in microcirculation. Microcirculation 2006; 13:199-207. DOI: 10.1080/10739680600556878.
-
(2006)
Microcirculation
, vol.13
, pp. 199-207
-
-
Kim, S.1
Kong, R.L.2
Popel, A.S.3
Intaglietta, M.4
Jonhson, P.C.5
-
41
-
-
78149303233
-
A comparative study of histogram-based thresholding of cell-free layer wisth in small blood vessels
-
Namgung B, Ong PK, Wong YH, Lim D, Chun KC, Kim S. A comparative study of histogram-based thresholding of cell-free layer wisth in small blood vessels. Physiological Measurement 2010; 31:N61-N70.
-
(2010)
Physiological Measurement
, vol.31
-
-
Namgung, B.1
Ong, P.K.2
Wong, Y.H.3
Lim, D.4
Chun, K.C.5
Kim, S.6
-
42
-
-
84883657694
-
-
MedCalc Software, Version 12.1.4 Broekstraat 52, 9030 Mariakerke, Belgium.
-
MedCalc Software, Version 12.1.4 Broekstraat 52, 9030 Mariakerke, Belgium.
-
-
-
-
43
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
|