메뉴 건너뛰기




Volumn 4, Issue 9, 2013, Pages

Simultaneous imaging of two-photon absorption and stimulated Raman scattering by spatial overlap modulation nonlinear optical microscopy

Author keywords

[No Author keywords available]

Indexed keywords

OPTICAL SIGNAL PROCESSING; PHOTONS; SEMICONDUCTOR QUANTUM DOTS; STIMULATED RAMAN SCATTERING;

EID: 84883438495     PISSN: None     EISSN: 21567085     Source Type: Journal    
DOI: 10.1364/BOE.4.001548     Document Type: Article
Times cited : (9)

References (24)
  • 1
    • 0025342635 scopus 로고
    • Two-photon laser scanning fluorescence microscopy
    • W. Denk, J. H. Strickler, and W. W. Webb, "Two-photon laser scanning fluorescence microscopy," Science 248(4951), 73-76 (1990).
    • (1990) Science , vol.248 , Issue.4951 , pp. 73-76
    • Denk, W.1    Strickler, J.H.2    Webb, W.W.3
  • 2
    • 0033747389 scopus 로고    scopus 로고
    • Multiphoton microscopy in life sciences
    • K. König, "Multiphoton microscopy in life sciences," J. Microsc. 200(2), 83-104 (2000).
    • (2000) J. Microsc , vol.200 , Issue.2 , pp. 83-104
    • König, K.1
  • 3
    • 0242353872 scopus 로고    scopus 로고
    • Nonlinear magic: Multiphoton microscopy in the biosciences
    • W. R. Zipfel, R. M. Williams, and W. W. Webb, "Nonlinear magic: multiphoton microscopy in the biosciences," Nat. Biotechnol. 21(11), 1369-1377 (2003).
    • (2003) Nat. Biotechnol , vol.21 , Issue.11 , pp. 1369-1377
    • Zipfel, W.R.1    Williams, R.M.2    Webb, W.W.3
  • 4
    • 0242385409 scopus 로고    scopus 로고
    • Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms
    • P. J. Campagnola and L. M. Loew, "Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms," Nat. Biotechnol. 21(11), 1356-1360 (2003).
    • (2003) Nat. Biotechnol , vol.21 , Issue.11 , pp. 1356-1360
    • Campagnola, P.J.1    Loew, L.M.2
  • 5
    • 0035397061 scopus 로고    scopus 로고
    • High resolution nonlinear microscopy: A review of sources and methods for achieving optimal imaging
    • J. Squier and M. Müller, "High resolution nonlinear microscopy: A review of sources and methods for achieving optimal imaging," Rev. Sci. Instrum. 72(7), 2855-2867 (2001).
    • (2001) Rev. Sci. Instrum , vol.72 , Issue.7 , pp. 2855-2867
    • Squier, J.1    Müller, M.2
  • 6
    • 0031075571 scopus 로고    scopus 로고
    • Nonlinear scanning laser microscopy by third harmonic generation
    • Y. Barad, H. Eisenberg, M. Horowitz, and Y. Silberberg, "Nonlinear scanning laser microscopy by third harmonic generation," Appl. Phys. Lett. 70(8), 922-924 (1997).
    • (1997) Appl. Phys. Lett , vol.70 , Issue.8 , pp. 922-924
    • Barad, Y.1    Eisenberg, H.2    Horowitz, M.3    Silberberg, Y.4
  • 7
    • 84975597771 scopus 로고
    • Scanning coherent anti-Stokes Raman microscope
    • M. D. Duncan, J. Reintjes, and T. J. Manuccia, "Scanning coherent anti-Stokes Raman microscope," Opt. Lett. 7(8), 350-352 (1982).
    • (1982) Opt. Lett , vol.7 , Issue.8 , pp. 350-352
    • Duncan, M.D.1    Reintjes, J.2    Manuccia, T.J.3
  • 8
    • 0001104529 scopus 로고    scopus 로고
    • Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering
    • A. Zumbusch, G. R. Holtom, and X. S. Xie, "Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82(20), 4142-4145 (1999).
    • (1999) Phys. Rev. Lett , vol.82 , Issue.20 , pp. 4142-4145
    • Zumbusch, A.1    Holtom, G.R.2    Xie, X.S.3
  • 9
    • 38449101653 scopus 로고    scopus 로고
    • Two-color, two-photon, and excited-state absorption microscopy
    • D. Fu, T. Ye, T. E. Matthews, G. Yurtsever, and W. S. Warren, "Two-color, two-photon, and excited-state absorption microscopy," J. Biomed. Opt. 12(5), 054004 (2007).
    • (2007) J. Biomed. Opt , vol.12 , Issue.5 , pp. 054004
    • Fu, D.1    Ye, T.2    Matthews, T.E.3    Yurtsever, G.4    Warren, W.S.5
  • 10
    • 38449092651 scopus 로고    scopus 로고
    • High-resolution in vivo imaging of blood vessels without labeling
    • D. Fu, T. Ye, T. E. Matthews, B. J. Chen, G. Yurtserver, and W. S. Warren, "High-resolution in vivo imaging of blood vessels without labeling," Opt. Lett. 32(18), 2641-2643 (2007).
    • (2007) Opt. Lett , vol.32 , Issue.18 , pp. 2641-2643
    • Fu, D.1    Ye, T.2    Matthews, T.E.3    Chen, B.J.4    Yurtserver, G.5    Warren, W.S.6
  • 11
    • 57849134248 scopus 로고    scopus 로고
    • Labelfree biomedical imaging with high sensitivity by stimulated Raman scattering microscopy
    • C. W. Freudiger, W. Min, B. G. Saar, S. Lu, G. R. Holtom, C. He, J. C. Tsai, J. X. Kang, and X. S. Xie, "Labelfree biomedical imaging with high sensitivity by stimulated Raman scattering microscopy," Science 322(5909), 1857-1861 (2008).
    • (2008) Science , vol.322 , Issue.5909 , pp. 1857-1861
    • Freudiger, C.W.1    Min, W.2    Saar, B.G.3    Lu, S.4    Holtom, G.R.5    He, C.6    Tsai, J.C.7    Kang, J.X.8    Xie, X.S.9
  • 12
    • 65149100490 scopus 로고    scopus 로고
    • Vibrational imaging based on stimulated Raman scattering microscopy
    • P. Nandakumar, A. Kovalev, and A. Volkmer, "Vibrational imaging based on stimulated Raman scattering microscopy," New J. Phys. 11(3), 033026 (2009).
    • (2009) New J. Phys , vol.11 , Issue.3 , pp. 033026
    • Nandakumar, P.1    Kovalev, A.2    Volkmer, A.3
  • 13
    • 61549101274 scopus 로고    scopus 로고
    • Analysis and experimental assessment of the sensitivity of stimulated Raman scattering microscopy
    • Y. Ozeki, F. Dake, S. Kajiyama, K. Fukui, and K. Itoh, "Analysis and experimental assessment of the sensitivity of stimulated Raman scattering microscopy," Opt. Express 17(5), 3651-3658 (2009).
    • (2009) Opt. Express , vol.17 , Issue.5 , pp. 3651-3658
    • Ozeki, Y.1    Dake, F.2    Kajiyama, S.3    Fukui, K.4    Itoh, K.5
  • 15
    • 84863889943 scopus 로고    scopus 로고
    • Cross-phase modulation spectral shifting: Nonlinear phase contrast in a pump-probe microscope
    • J. W. Wilson, P. Samineni, W. S. Warren, and M. C. Fischer, "Cross-phase modulation spectral shifting: nonlinear phase contrast in a pump-probe microscope," Biomed. Opt. Express 3(5), 854-862 (2012).
    • (2012) Biomed. Opt. Express , vol.3 , Issue.5 , pp. 854-862
    • Wilson, J.W.1    Samineni, P.2    Warren, W.S.3    Fischer, M.C.4
  • 16
    • 33645517672 scopus 로고    scopus 로고
    • In-vivo multi-nonlinear optical imaging of a living cell using a supercontinuum light source generated from a photonic crystal fiber
    • H. Kano and H. O. Hamaguchi, "In-vivo multi-nonlinear optical imaging of a living cell using a supercontinuum light source generated from a photonic crystal fiber," Opt. Express 14(7), 2798-2804 (2006).
    • (2006) Opt. Express , vol.14 , Issue.7 , pp. 2798-2804
    • Kano, H.1    Hamaguchi, H.O.2
  • 17
    • 0037106701 scopus 로고    scopus 로고
    • Ultrafast measurement of two-photon absorption by loss modulation
    • P. Tian and W. S. Warren, "Ultrafast measurement of two-photon absorption by loss modulation," Opt. Lett. 27(18), 1634-1636 (2002).
    • (2002) Opt. Lett , vol.27 , Issue.18 , pp. 1634-1636
    • Tian, P.1    Warren, W.S.2
  • 19
    • 84863275180 scopus 로고    scopus 로고
    • Quantitative chemical imaging with multiplex stimulated Raman scattering microscopy
    • D. Fu, F.-K. Lu, X. Zhang, C. Freudiger, D. R. Pernik, G. Holtom, and X. S. Xie, "Quantitative chemical imaging with multiplex stimulated Raman scattering microscopy," J. Am. Chem. Soc. 134(8), 3623-3626 (2012).
    • (2012) J. Am. Chem. Soc , vol.134 , Issue.8 , pp. 3623-3626
    • Fu, D.1    Lu, F.-K.2    Zhang, X.3    Freudiger, C.4    Pernik, D.R.5    Holtom, G.6    Xie, X.S.7
  • 20
    • 84864124095 scopus 로고    scopus 로고
    • Phasor analysis for nonlinear pump-probe microscopy
    • F. E. Robles, J. W. Wilson, M. C. Fischer, and W. S. Warren, "Phasor analysis for nonlinear pump-probe microscopy," Opt. Express 20(15), 17082-17092 (2012).
    • (2012) Opt. Express , vol.20 , Issue.15 , pp. 17082-17092
    • Robles, F.E.1    Wilson, J.W.2    Fischer, M.C.3    Warren, W.S.4
  • 21
    • 29144446288 scopus 로고    scopus 로고
    • Polar plot representation for frequency-domain analysis of fluorescence lifetimes
    • G. I. Redford and R. M. Clegg, "Polar plot representation for frequency-domain analysis of fluorescence lifetimes," J. Fluoresc. 15(5), 805-815 (2005).
    • (2005) J. Fluoresc , vol.15 , Issue.5 , pp. 805-815
    • Redford, G.I.1    Clegg, R.M.2
  • 22
    • 38349018672 scopus 로고    scopus 로고
    • The phasor approach to fluorescence lifetime imaging analysis
    • M. A. Digman, V. R. Caiolfa, M. Zamai, and E. Gratton, "The phasor approach to fluorescence lifetime imaging analysis," Biophys. J. 94(2), L14-L16 (2008).
    • (2008) Biophys. J , vol.94 , Issue.2
    • Digman, M.A.1    Caiolfa, V.R.2    Zamai, M.3    Gratton, E.4
  • 23
    • 80051995853 scopus 로고    scopus 로고
    • Phasor approach to fluorescence lifetime microscopy distinguishes different metabolic states of germ cells in a live tissue
    • C. Stringari, A. Cinquin, O. Cinquin, M. A. Digman, P. J. Donovan, and E. Gratton, "Phasor approach to fluorescence lifetime microscopy distinguishes different metabolic states of germ cells in a live tissue," Proc. Natl. Acad. Sci. U.S.A. 108(33), 13582-13587 (2011).
    • (2011) Proc. Natl. Acad. Sci. U.S.A , vol.108 , Issue.33 , pp. 13582-13587
    • Stringari, C.1    Cinquin, A.2    Cinquin, O.3    Digman, M.A.4    Donovan, P.J.5    Gratton, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.