메뉴 건너뛰기




Volumn 58, Issue 9, 2013, Pages 1442-1448

Humidification performance of humidifying devices for tracheostomized patients with spontaneous breathing: A bench study

Author keywords

CPAP; Heat and moisture exchanger; HME; Humidification; Mechanical ventilation; Respiratory; Spontaneous breathing; Supplemental oxygen; Tracheostomy

Indexed keywords

OXYGEN;

EID: 84883307530     PISSN: 00201324     EISSN: 19433654     Source Type: Journal    
DOI: 10.4187/respcare.02093     Document Type: Article
Times cited : (27)

References (10)
  • 2
    • 0024454998 scopus 로고
    • Passive and active inspired gas humidification in infants and children
    • Bissonnette B, Sessler DI, LaFlamme P. Passive and active inspired gas humidification in infants and children. Anesthesiology 1989; 71(3):350-354.
    • (1989) Anesthesiology , vol.71 , Issue.3 , pp. 350-354
    • Bissonnette, B.1    Sessler, D.I.2    Laflamme, P.3
  • 3
    • 0026907566 scopus 로고
    • American Association for Respiratory Care. AARC clinical practice guideline. Humidification during mechanical ventilation
    • Branson RD, Campbell RS, Chatburn RL, Covington J; American Association for Respiratory Care. AARC clinical practice guideline. Humidification during mechanical ventilation. Respir Care 1992; 37(8):887-890.
    • (1992) Respir Care , vol.37 , Issue.8 , pp. 887-890
    • Branson, R.D.1    Campbell, R.S.2    Chatburn, R.L.3    Covington, J.4
  • 4
    • 0033010764 scopus 로고    scopus 로고
    • Humidification for patients with artificial airways
    • Branson RD. Humidification for patients with artificial airways. Respir Care 1999;44(6):630-641.
    • (1999) Respir Care , vol.44 , Issue.6 , pp. 630-641
    • Branson, R.D.1
  • 5
    • 60249083574 scopus 로고    scopus 로고
    • Groupe de Travail sur les Respirateurs de l'AP-HP. Humidification performance of 48 passive airway humidifiers: Comparison with manufacturer data
    • Lellouche F, Taillé S, Lefrançois F, Deye N, Maggiore SM, Jouvet P, et al; Groupe de Travail sur les Respirateurs de l'AP-HP. Humidification performance of 48 passive airway humidifiers: comparison with manufacturer data. Chest 2009;135(2):276-286.
    • (2009) Chest , vol.135 , Issue.2 , pp. 276-286
    • Lellouche, F.1    Taillé, S.2    Lefrançois, F.3    Deye, N.4    Maggiore, S.M.5    Jouvet, P.6
  • 6
    • 33748483057 scopus 로고    scopus 로고
    • Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidification
    • Inui D, Oto J, Nishimura M. Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidification. BMC Pulm Med 2006;6:19.
    • (2006) BMC Pulm Med , vol.6 , pp. 19
    • Inui, D.1    Oto, J.2    Nishimura, M.3
  • 7
    • 68949119361 scopus 로고    scopus 로고
    • Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: A respiratory system model study
    • Lucato JJ, Adams AB, Souza R, Torquato JA, Carvalho CR, Marini JJ. Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: a respiratory system model study. Clinics (São Paulo) 2009;64(6):585-590.
    • (2009) Clinics (São Paulo) , vol.64 , Issue.6 , pp. 585-590
    • Lucato, J.J.1    Adams, A.B.2    Souza, R.3    Torquato, J.A.4    Carvalho, C.R.5    Marini, J.J.6
  • 8
    • 67349283019 scopus 로고    scopus 로고
    • Endotracheal temperature and humidity measurements in laryngectomized patients: Intra- and inter-patient variability
    • Scheenstra RJ, Muller SH, Vincent A, Sinaasappel M, Zuur JK, Hilger FJM. Endotracheal temperature and humidity measurements in laryngectomized patients: intra- and inter-patient variability. Med Biol Eng Comput 2009;47(7):773-782.
    • (2009) Med Biol Eng Comput , vol.47 , Issue.7 , pp. 773-782
    • Scheenstra, R.J.1    Muller, S.H.2    Vincent, A.3    Sinaasappel, M.4    Zuur, J.K.5    Hilger, F.J.M.6
  • 10
    • 84866235371 scopus 로고    scopus 로고
    • Humidification performance of heat and moisture exchangers for pediatric use
    • 2012
    • Chikata Y, Sumida C, Oto J, Imanaka H, Nishimura M. Humidification performance of heat and moisture exchangers for pediatric use. Crit Care Res Pract 2012;2012:439267.
    • (2012) Crit Care Res Pract , pp. 439267
    • Chikata, Y.1    Sumida, C.2    Oto, J.3    Imanaka, H.4    Nishimura, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.