메뉴 건너뛰기




Volumn 41, Issue 5, 2013, Pages 455-462

Femtosecond laser-assisted cataract surgery compared with conventional cataract surgery

Author keywords

Capsulotomy; Cataract surgery; Femtosecond; Phacoemulsification

Indexed keywords

AGED; ARTICLE; CAPSULOTOMY; CATARACT; CATARACT EXTRACTION; CONTROLLED STUDY; HUMAN; INTERMETHOD COMPARISON; LENS IMPLANT; MAJOR CLINICAL STUDY; OPERATION DURATION; OPHTHALMIC FEMTOSECOND LASER; OPTICAL COHERENCE TOMOGRAPHY; PEROPERATIVE COMPLICATION; PHACOEMULSIFICATION;

EID: 84883305751     PISSN: 14426404     EISSN: 14429071     Source Type: Journal    
DOI: 10.1111/ceo.12025     Document Type: Article
Times cited : (118)

References (36)
  • 3
    • 0036679234 scopus 로고    scopus 로고
    • Ultrafast (femtosecond) laser refractive surgery
    • Sugar A. Ultrafast (femtosecond) laser refractive surgery. Curr Opin Ophthalmol 2002; 13: 246-249.
    • (2002) Curr Opin Ophthalmol , vol.13 , pp. 246-249
    • Sugar, A.1
  • 4
  • 5
    • 74049134979 scopus 로고    scopus 로고
    • Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery
    • Nagy Z, Takacs A, Filkorn T, Sarayba M. Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery. J Refract Surg 2009; 25: 1053-1060.
    • (2009) J Refract Surg , vol.25 , pp. 1053-1060
    • Nagy, Z.1    Takacs, A.2    Filkorn, T.3    Sarayba, M.4
  • 6
    • 80052216505 scopus 로고    scopus 로고
    • Comparison of intraocular lens decentration parameters after femtosecond and manual capsulotomies
    • Nagy ZZ, Kranitz K, Takacs AI, Mihaltz K, Kovacs I, Knorz MC. Comparison of intraocular lens decentration parameters after femtosecond and manual capsulotomies. J Refract Surg 2011; 27: 1-6.
    • (2011) J Refract Surg , vol.27 , pp. 1-6
    • Nagy, Z.Z.1    Kranitz, K.2    Takacs, A.I.3    Mihaltz, K.4    Kovacs, I.5    Knorz, M.C.6
  • 7
    • 84861551754 scopus 로고    scopus 로고
    • Macular morphology assessed by optical coherence tomography image segmentation after femtosecond laser-assisted and standard cataract surgery
    • Nagy ZZ, Excesy M, Kovacs I etal. Macular morphology assessed by optical coherence tomography image segmentation after femtosecond laser-assisted and standard cataract surgery. J Cataract Refract Surg 2012; 38: 941-946.
    • (2012) J Cataract Refract Surg , vol.38 , pp. 941-946
    • Nagy, Z.Z.1    Excesy, M.2    Kovacs, I.3
  • 8
    • 78449284653 scopus 로고    scopus 로고
    • Femtosecond laser-assisted cataract surgery with integrated optical coherence tomography
    • Palanker DV, Blumenkranz MS, Andersen D etal. Femtosecond laser-assisted cataract surgery with integrated optical coherence tomography. Sci Transl Med 2010; 2: 1-8.
    • (2010) Sci Transl Med , vol.2 , pp. 1-8
    • Palanker, D.V.1    Blumenkranz, M.S.2    Andersen, D.3
  • 10
    • 80052216657 scopus 로고    scopus 로고
    • Femtosecond laser capsulotomy and manual continuous curvilinear capsulorhexis parameters and their effects on intraocular lens centration
    • Kranitz K, Takacs A, Mihaltz K, Kovacs I, Knorz MC, Nagy ZZ. Femtosecond laser capsulotomy and manual continuous curvilinear capsulorhexis parameters and their effects on intraocular lens centration. J Refract Surg 2011; 27: 558-563.
    • (2011) J Refract Surg , vol.27 , pp. 558-563
    • Kranitz, K.1    Takacs, A.2    Mihaltz, K.3    Kovacs, I.4    Knorz, M.C.5    Nagy, Z.Z.6
  • 11
    • 77952522156 scopus 로고    scopus 로고
    • Femtosecond laser-assisted cataract incisions: architectural stability and reproducibility
    • Masket S, Sarayba M, Ignacio T, Fram N. Femtosecond laser-assisted cataract incisions: architectural stability and reproducibility. J Cataract Refract Surg 2010; 36: 1048-1049.
    • (2010) J Cataract Refract Surg , vol.36 , pp. 1048-1049
    • Masket, S.1    Sarayba, M.2    Ignacio, T.3    Fram, N.4
  • 12
    • 84892903006 scopus 로고    scopus 로고
    • First safety study of femtosecond laser photodisruption in animal lenses: tissue morphology and hydrophilic acrylic intraocular lenses: comparative study
    • Krueger RR, Kuszak J, Lubatschowski H, Myers RI, Ripken T, Heisterkamp A. First safety study of femtosecond laser photodisruption in animal lenses: tissue morphology and hydrophilic acrylic intraocular lenses: comparative study. J Cataract Refract Surg 2006; 32: 1201-1205.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1201-1205
    • Krueger, R.R.1    Kuszak, J.2    Lubatschowski, H.3    Myers, R.I.4    Ripken, T.5    Heisterkamp, A.6
  • 14
    • 45149117667 scopus 로고    scopus 로고
    • Corneal endothelial cell damage by free radicals associated with ultrasound oscillation
    • Murano N, Ischizaki M, Sato S, Fukuda Y, Takahashi H. Corneal endothelial cell damage by free radicals associated with ultrasound oscillation. Arch Ophthalmol 2008; 126: 816-821.
    • (2008) Arch Ophthalmol , vol.126 , pp. 816-821
    • Murano, N.1    Ischizaki, M.2    Sato, S.3    Fukuda, Y.4    Takahashi, H.5
  • 15
    • 65249131787 scopus 로고    scopus 로고
    • The effect of phacoemulsification energy on the redox state of cultured human corneal endothelial cells
    • Shin YJ, Nishi Y, Engler C etal. The effect of phacoemulsification energy on the redox state of cultured human corneal endothelial cells. Arch Ophthalmol 2009; 127: 435-441.
    • (2009) Arch Ophthalmol , vol.127 , pp. 435-441
    • Shin, Y.J.1    Nishi, Y.2    Engler, C.3
  • 17
    • 40449112007 scopus 로고    scopus 로고
    • Corneal endothelial cell loss after cataract extraction by using ultrasound phacoemulsification versus a fluid-based system
    • Richard J, Hoffart L, Chavane F, Ridings B, Conrath J. Corneal endothelial cell loss after cataract extraction by using ultrasound phacoemulsification versus a fluid-based system. Cornea 2008; 27: 17-21.
    • (2008) Cornea , vol.27 , pp. 17-21
    • Richard, J.1    Hoffart, L.2    Chavane, F.3    Ridings, B.4    Conrath, J.5
  • 18
    • 2342657886 scopus 로고    scopus 로고
    • Power modulations in new phacoemulsification technology: improved outcomes
    • Fine IH, Packer M, Hoffman RS. Power modulations in new phacoemulsification technology: improved outcomes. J Cataract Refract Surg 2004; 30: 1014-1019.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1014-1019
    • Fine, I.H.1    Packer, M.2    Hoffman, R.S.3
  • 19
    • 0036669682 scopus 로고    scopus 로고
    • Prostaglandins and cystoid macular edema
    • Miyake K, Ibaraki N. Prostaglandins and cystoid macular edema. Surv Ophthalmol 2002; 47 (Suppl.): S203-218.
    • (2002) Surv Ophthalmol , vol.47 , Issue.SUPPL.
    • Miyake, K.1    Ibaraki, N.2
  • 20
    • 0032412542 scopus 로고    scopus 로고
    • The incidence, pathogenesis, and treatment of cystoid macular edema following cataract surgery
    • Flach AJ. The incidence, pathogenesis, and treatment of cystoid macular edema following cataract surgery. Trans Am Ophthalmol Soc 1998; 96: 557-634.
    • (1998) Trans Am Ophthalmol Soc , vol.96 , pp. 557-634
    • Flach, A.J.1
  • 22
    • 0142227840 scopus 로고    scopus 로고
    • Incidence of cystoid macular edema after uncomplicated phacoemulsification
    • Mentes J, Erakgun T, Afrashi F, Kerci G. Incidence of cystoid macular edema after uncomplicated phacoemulsification. Ophthalmologica 2003; 217: 408-412.
    • (2003) Ophthalmologica , vol.217 , pp. 408-412
    • Mentes, J.1    Erakgun, T.2    Afrashi, F.3    Kerci, G.4
  • 24
    • 36348940951 scopus 로고    scopus 로고
    • Macular thickness after uneventful cataract surgery determined by optical coherence tomography
    • Jagow B, Ohrloff C, Kohnen T. Macular thickness after uneventful cataract surgery determined by optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 2007; 245: 1765-1771.
    • (2007) Graefes Arch Clin Exp Ophthalmol , vol.245 , pp. 1765-1771
    • Jagow, B.1    Ohrloff, C.2    Kohnen, T.3
  • 25
    • 38349143475 scopus 로고    scopus 로고
    • Change of foveal and perifoveal thickness measured by OCT after phacoemulsification and IOL implantation
    • Biro Z, Balla Z, Kovacs B. Change of foveal and perifoveal thickness measured by OCT after phacoemulsification and IOL implantation. Eye 2008; 22: 8-12.
    • (2008) Eye , vol.22 , pp. 8-12
    • Biro, Z.1    Balla, Z.2    Kovacs, B.3
  • 26
    • 33947310765 scopus 로고    scopus 로고
    • Evaluation of macular changes after uncomplicated phacoemulsification surgery by optical coherence tomography
    • Perente I, Utine CA, Ozturker C etal. Evaluation of macular changes after uncomplicated phacoemulsification surgery by optical coherence tomography. Curr Eye Res 2007; 32: 241-247.
    • (2007) Curr Eye Res , vol.32 , pp. 241-247
    • Perente, I.1    Utine, C.A.2    Ozturker, C.3
  • 28
    • 45349091789 scopus 로고    scopus 로고
    • New technology for sizing the continuous curvilinear capsulorhexis: prospective trial
    • Dick HB, Pena-Aceves A, Manns A, Krummenauer F. New technology for sizing the continuous curvilinear capsulorhexis: prospective trial. J Cataract Refract Surg 2008; 34: 1136-1144.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 1136-1144
    • Dick, H.B.1    Pena-Aceves, A.2    Manns, A.3    Krummenauer, F.4
  • 29
    • 0027200679 scopus 로고
    • Decentration associated with asymmetric capsular shrinkage and intraocular lens size
    • Ohmi S. Decentration associated with asymmetric capsular shrinkage and intraocular lens size. J Cataract Refract Surg 1993; 19: 640-643.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 640-643
    • Ohmi, S.1
  • 30
    • 0033008477 scopus 로고    scopus 로고
    • The relationship between capsulorhexis size and anterior chamber depth relation
    • Cekic O, Batman C. The relationship between capsulorhexis size and anterior chamber depth relation. Ophthalmic Surg Lasers 1999; 30: 185-190.
    • (1999) Ophthalmic Surg Lasers , vol.30 , pp. 185-190
    • Cekic, O.1    Batman, C.2
  • 31
    • 41949113224 scopus 로고    scopus 로고
    • Sources of error in intraocular lens power calculations
    • Norrby S. Sources of error in intraocular lens power calculations. J Cataract Refract Surg 2008; 34: 368-376.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 368-376
    • Norrby, S.1
  • 32
    • 84860481554 scopus 로고    scopus 로고
    • Intraocular lens tilt and decentration measured by Scheimpflug camera following manual or femtosecond laser-created continuous circular capsulotomy
    • Kranitz K, Mihaltz K, Sandor GL, Takacs A, Knorz MC, Nagy ZZ. Intraocular lens tilt and decentration measured by Scheimpflug camera following manual or femtosecond laser-created continuous circular capsulotomy. J Refract Surg 2012; 28: 259-263.
    • (2012) J Refract Surg , vol.28 , pp. 259-263
    • Kranitz, K.1    Mihaltz, K.2    Sandor, G.L.3    Takacs, A.4    Knorz, M.C.5    Nagy, Z.Z.6
  • 34
    • 0027301363 scopus 로고
    • Capsule contraction syndrome
    • Davison JA. Capsule contraction syndrome. J Cataract Refract Surg 1993; 19: 582-589.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 582-589
    • Davison, J.A.1
  • 35
    • 0027217944 scopus 로고
    • Intraocular lens encapsulation by shrinkage of the capsulorhexis opening
    • Nishi O, Nishi K. Intraocular lens encapsulation by shrinkage of the capsulorhexis opening. J Cataract Refract Surg 1993; 19: 544-545.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 544-545
    • Nishi, O.1    Nishi, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.