-
1
-
-
0023255774
-
THEORIE UND OPERATIONSTECHNIK DER KAPSULORHEXIS
-
Neuhann T. Theory and surgical technic of capsulorhexis [German]. Klin Monatsbl Augenheilkd. 1987;190(6):542-545. (Pubitemid 17091268)
-
(1987)
Klinische Monatsblatter fur Augenheilkunde
, vol.190
, Issue.6
, pp. 542-545
-
-
Neuhann, T..1
-
2
-
-
0025021178
-
Development, advantages, and methods of the continuous circular capsulorhexis technique
-
Gimbel HV, Neuhann T. Development, advantages, and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1990;16(1):31-37. (Pubitemid 20082708)
-
(1990)
Journal of Cataract and Refractive Surgery
, vol.16
, Issue.1
, pp. 31-37
-
-
Gimbel, H.V.1
Neuhann, T.2
-
3
-
-
0025967247
-
Continuous curvilinear capsulorhexis
-
Gimbel HV, Neuhann T. Continuous curvilinear capsulorhexis. J Cataract Refract Surg. 1991;17(1):110-111.
-
(1991)
J Cataract Refract Surg
, vol.17
, Issue.1
, pp. 110-111
-
-
Gimbel, H.V.1
Neuhann, T.2
-
4
-
-
0030040687
-
Capsulorhexis size and posterior capsule opacification
-
Ravalico G, Tognetto D, Palomba M, Busatto P, Baccara F. Capsulorhexis size and posterior capsule opacification. J Cataract Refract Surg. 1996;22(1):98-103. (Pubitemid 26044081)
-
(1996)
Journal of Cataract and Refractive Surgery
, vol.22
, Issue.1
, pp. 98-103
-
-
Ravalico, G.1
Tognetto, D.2
Palomba, M.3
Busatto, P.4
Baccara, F.5
-
5
-
-
0642281869
-
The effect of capsulorhexis size on development of posterior capsule opacification: Small (4.5 to 5.0 mm) versus large (6.0 to 7.0 mm)
-
Aykan U, Bilge AH, Karadayi K. The effect of capsulorhexis size on development of posterior capsule opacification: small (4.5 to 5.0mm) versus large (6.0 to 7.0mm). Eur J Ophthalmol. 2003;13(6):541-545. (Pubitemid 38208837)
-
(2003)
European Journal of Ophthalmology
, vol.13
, Issue.6
, pp. 541-545
-
-
Aykan, U.1
Bilge, A.H.2
Karadayi, K.3
Akin, T.4
-
6
-
-
0032827818
-
The effect of capsulorhexis size on posterior capsular opacification: One-year results of a randomized prospective trial
-
DOI 10.1016/S0002-9394(99)00157-9, PII S0002939499001579
-
Hollick EJ, Spalton DJ, Meacock WR. The effect of capsulorhexis size on posterior capsular opacification: one-year results of a randomized prospective trial. Am J Ophthalmol. 1999;128(3):271-279. (Pubitemid 29413221)
-
(1999)
American Journal of Ophthalmology
, vol.128
, Issue.3
, pp. 271-279
-
-
Hollick, E.J.1
Spalton, D.J.2
Meacock, W.R.3
-
7
-
-
0034905521
-
Effect of in-the-bag intraocular lens fixation on the prevention of posterior capsule opacification
-
Ram J, Pandey SK, Apple DJ, et al. Effect of in-the-bag intraocular lens fixation on the prevention of posterior capsule opacification. J Cataract Refract Surg. 2001;27(7):367-370.
-
(2001)
J Cataract Refract Surg
, vol.27
, Issue.7
, pp. 367-370
-
-
Ram, J.1
Pandey, S.K.2
Apple, D.J.3
-
8
-
-
80052248356
-
Pearls for sizing the capsulorrhexis
-
Chang DF, Dewey S, Tipperman R, Wallace RB. Pearls for sizing the capsulorrhexis. Cataract & Refractive Surgery Today Europe. 2008;3(9):40-44.
-
(2008)
Cataract & Refractive Surgery Today Europe
, vol.3
, Issue.9
, pp. 40-44
-
-
Chang, D.F.1
Dewey, S.2
Tipperman, R.3
Wallace, R.B.4
-
9
-
-
0034750468
-
Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation
-
DOI 10.1136/bjo.85.11.1294
-
Hayashi K, Hayashi H, Nakao F, Hayashi F. Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation. Br J Ophthalmol. 2001;85(11):1294-1297. (Pubitemid 33016105)
-
(2001)
British Journal of Ophthalmology
, vol.85
, Issue.11
, pp. 1294-1297
-
-
Hayashi, K.1
Hayashi, H.2
Nakao, F.3
Hayashi, F.4
-
10
-
-
0031762312
-
Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome
-
Hayashi H, Hayashi K, Nakao F, Hayashi F. Anterior capsule contraction and intraocular lens dislocation in eyes with pseudo-exfoliation syndrome. Br J Ophthalmol. 1998;82(12):1429-1432. (Pubitemid 28556531)
-
(1998)
British Journal of Ophthalmology
, vol.82
, Issue.12
, pp. 1429-1432
-
-
Hayashi, H.1
Hayashi, K.2
Nakao, F.3
Hayashi, F.4
-
11
-
-
74049134979
-
Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery
-
Nagy Z, Takacs A, Filkorn T, Sarayba M. Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery. J Refract Surg. 2009;25(12):1053-1060.
-
(2009)
J Refract Surg
, vol.25
, Issue.12
, pp. 1053-1060
-
-
Nagy, Z.1
Takacs, A.2
Filkorn, T.3
Sarayba, M.4
-
12
-
-
0037345992
-
First clinical results with the femtosecond neodynium-glass laser in refractive surgery
-
Ratkay-Traub I, Ferincz IE, Juhasz T, Kurtz RM, Krueger RR. First clinical results with the femtosecond neodymium-glass laser in refractive surgery. J Refract Surg. 2003;19(2):94-103. (Pubitemid 36350875)
-
(2003)
Journal of Refractive Surgery
, vol.19
, Issue.2
, pp. 94-103
-
-
Ratkay-Traub, I.1
Ferincz, I.E.2
Juhasz, T.3
Kurtz, R.M.4
Krueger, R.R.5
-
13
-
-
0037239362
-
Femtosecond laser flap creation for laser in situ keratomileusis: Six-month follow-up of initial U.S. clinical series
-
Nordan LT, Slade SG, Baker RN, Suarez C, Juhasz T, Kurtz R. Femtosecond laser flap creation for laser in situ keratomileusis: six month follow-up of initial U.S. clinical series. J Refract Surg. 2003;19(1):8-14. (Pubitemid 36126019)
-
(2003)
Journal of Refractive Surgery
, vol.19
, Issue.1
, pp. 8-14
-
-
Nordan, L.T.1
Slade, S.G.2
Baker, R.N.3
Suarez, C.4
Juhasz, T.5
Kurtz, R.6
-
14
-
-
13844305846
-
Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes: Potential impact on wavefront-guided laser in situ keratomileusis
-
DOI 10.1016/j.jcrs.2004.10.037
-
Tran DB, Sarayba MA, Bor Z, et al. Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes: potential impact on wavefront-guided laser in situ keratomileusis. J Cataract Refract Surg. 2005;31(1):97-105. (Pubitemid 40260696)
-
(2005)
Journal of Cataract and Refractive Surgery
, vol.31
, Issue.1
, pp. 97-105
-
-
Tran, D.B.1
Sarayba, M.A.2
Bor, Z.3
Garufis, C.4
Duh, Y.-J.5
Soltes, C.R.6
Juhasz, T.7
Kurtz, R.M.8
-
15
-
-
3042645534
-
Messmethode zur bestimmung der rotation und der dezentrierung von intraokularlinsen
-
Becker KA, Auffarth GU, Völcker HE. Measurement method for the determination of rotation and decentration of intraocular lenses [German]. Ophthalmologe. 2004;101(6):600-603. (Pubitemid 38843105)
-
(2004)
Ophthalmologe
, vol.101
, Issue.6
, pp. 600-603
-
-
Becker, K.A.1
Auffarth, G.U.2
Volcker, H.E.3
-
16
-
-
0036293815
-
Pupil location under mesopic, photopic, and pharmacologically dilated conditions
-
Yang Y, Thompson K, Burns SA. Pupil location under mesopic, photopic, and pharmacologically dilated conditions. Invest Ophthalmol Vis Sci. 2002;43(7):2508-2512. (Pubitemid 34700688)
-
(2002)
Investigative Ophthalmology and Visual Science
, vol.43
, Issue.7
, pp. 2508-2512
-
-
Yang, Y.1
Thompson, K.2
Burns, S.A.3
-
17
-
-
0036859744
-
A new intraocular lens design to reduce spherical aberration of pseudophakic eyes
-
Holladay JT, Piers PA, Koranyi G, van der Mooren M, Norrby NE. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. J Refract Surg. 2002;18(6):683-691. (Pubitemid 35429194)
-
(2002)
Journal of Refractive Surgery
, vol.18
, Issue.6
, pp. 683-691
-
-
Holladay, J.T.1
Piers, P.A.2
Koranyi, G.3
Van Der, M.M.4
Norrby, N.E.S.5
-
18
-
-
80052216505
-
Comparison of IOL decentration parameters after femtosecond and manual capsulotomies
-
Nagy ZZ, Kránitz K, Takacs AI, Miháltz K, Kovacs I, Knorz MC. Comparison of IOL decentration parameters after femtosecond and manual capsulotomies. J Refract Surg. 2011;27(8):564-569.
-
(2011)
J Refract Surg
, vol.27
, Issue.8
, pp. 564-569
-
-
Nagy, Z.Z.1
Kránitz, K.2
Takacs, A.I.3
Miháltz, K.4
Kovacs, I.5
Knorz, M.C.6
-
19
-
-
0033008477
-
The relationship between capsulorhexis size and anterior chamber depth relation
-
Erratum in Ophthalmic Surg Lasers. 1999;30(9):714
-
Cekiç O, Batman C. The relationship between capsulorhexis size and anterior chamber depth relation. Ophthalmic Surg Lasers. 1999;30(3):185-190. Erratum in Ophthalmic Surg Lasers. 1999;30(9):714.
-
(1999)
Ophthalmic Surg Lasers
, vol.30
, Issue.3
, pp. 185-190
-
-
Cekiç, O.1
Batman, C.2
|