메뉴 건너뛰기




Volumn 34, Issue 9, 2013, Pages

A fibre-optic oxygen sensor for monitoring human breathing

Author keywords

breath by breath monitoring; breathing rate; fibre optic oxygen sensor; fluorescence quenching

Indexed keywords

COST EFFECTIVENESS; FLUORESCENCE QUENCHING; OXYGEN; OXYGEN SENSORS; PARTIAL PRESSURE;

EID: 84883185979     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/34/9/N71     Document Type: Article
Times cited : (19)

References (17)
  • 1
    • 82555197034 scopus 로고    scopus 로고
    • A cylindrical-core fibre optic oxygen sensor based on fluorescence quenching of a platinum complex immobilized in a polymer matrix
    • 10.1109/JSEN.2011.2132758 1530-437X
    • Chen R, Farmery A D, Obeid A and Hahn C E W 2012 A cylindrical-core fibre optic oxygen sensor based on fluorescence quenching of a platinum complex immobilized in a polymer matrix IEEE Sensors J. 12 71-75
    • (2012) IEEE Sensors J. , vol.12 , Issue.1 , pp. 71-75
    • Chen, R.1    Farmery, A.D.2    Obeid, A.3    Hahn, C.E.W.4
  • 2
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring in cardiovascular surgery
    • 10.1111/j.1749-6632.1962.tb13623.x 0077-8923
    • Clark L C Jr and Lyons C 1962 Electrode systems for continuous monitoring in cardiovascular surgery Ann New York Acad. Sci. 102 29-45
    • (1962) Ann New York Acad. Sci. , vol.102 , Issue.1 , pp. 29-45
    • Clark, L.C.1    Lyons, C.2
  • 3
    • 0033485583 scopus 로고    scopus 로고
    • Oxygen sensors based on luminescence quenching
    • 10.1021/ac9908546 0003-2700
    • Demas J N, Degraff B A and Coleman P B 1999 Oxygen sensors based on luminescence quenching Anal. Chem. 71 793A-800A
    • (1999) Anal. Chem. , vol.71 , Issue.23
    • Demas, J.N.1    Degraff, B.A.2    Coleman, P.B.3
  • 5
    • 0031812831 scopus 로고    scopus 로고
    • Electrochemical analysis of blood-gases, gases and vapours
    • Hahn C E W 1996 Electrochemical analysis of blood-gases, gases and vapours Analyst 123 57R-86R
    • (1996) Analyst , vol.123
    • Hahn, C.E.W.1
  • 9
    • 33646204624 scopus 로고    scopus 로고
    • Nanostructured optical fibre sensors for breathing airflow monitoring
    • 10.1088/0957-0233/17/5/S44 0957-0233
    • Kang Y, Ruan H, Wang Y, Arregui F J, Matias I R and Claus R O 2006 Nanostructured optical fibre sensors for breathing airflow monitoring Meas. Sci. Technol. 17 1207-10
    • (2006) Meas. Sci. Technol. , vol.17 , Issue.5 , pp. 1207-1210
    • Kang, Y.1    Ruan, H.2    Wang, Y.3    Arregui, F.J.4    Matias, I.R.5    Claus, R.O.6
  • 10
    • 84883156455 scopus 로고    scopus 로고
    • On line measurement of oxygen: Review and new developments
    • Langridge S 2010 On line measurement of oxygen: review and new developments ISA 55th Analysis Division Symp. (New Orleans, LA, USA,) pp 1-15 (session 5.1)
    • (2010) ISA 55th Analysis Division Symp. , pp. 1-15
    • Langridge, S.1
  • 11
    • 11144238311 scopus 로고    scopus 로고
    • The vexatious vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage
    • DOI 10.1016/j.annemergmed.2004.06.016, PII S0196064404006493
    • Lovett P B, Buchwald J M, Sturmann K and Bijur P 2005 The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage Ann. Emerg. Med. 45 68-76 (Pubitemid 40051170)
    • (2005) Annals of Emergency Medicine , vol.45 , Issue.1 , pp. 68-76
    • Lovett, P.B.1    Buchwald, J.M.2    Sturmann, K.3    Bijur, P.4
  • 12
    • 77957825442 scopus 로고    scopus 로고
    • A new system for continuous monitoring of breathing and kinetic activity
    • 10.1155/2010/434863 1687-725X 434863
    • Marani R, Gelao G and Perri A G 2010 A new system for continuous monitoring of breathing and kinetic activity J. Sensors 2010 434863
    • (2010) J. Sensors , vol.2010
    • Marani, R.1    Gelao, G.2    Perri, A.G.3
  • 13
    • 77956013454 scopus 로고    scopus 로고
    • A breathing rate sensor with plastic optical fiber
    • 10.1063/1.3480601 0003-6951 073703
    • Mohanty L and Kuang K S C 2010 A breathing rate sensor with plastic optical fiber Appl. Phys. Lett. 97 073703
    • (2010) Appl. Phys. Lett. , vol.97 , Issue.7
    • Mohanty, L.1    Kuang, K.S.C.2
  • 14
    • 0742333438 scopus 로고
    • Development of a highly sensitive galvanic cell oxygen sensor
    • 10.1016/0039-9140(94)00248-Q 0039-9140
    • Oqino H and Asakura K 1995 Development of a highly sensitive galvanic cell oxygen sensor Talanta 42 305-10
    • (1995) Talanta , vol.42 , Issue.2 , pp. 305-310
    • Oqino, H.1    Asakura, K.2
  • 15
    • 34547604102 scopus 로고    scopus 로고
    • Continuous oximetry/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia
    • DOI 10.1213/01.ane.0000269489.26048.63, PII 0000053920070800000023
    • Overdyk F J, Carter R, Maddox R R, Callura J, Herrin A E and Henriquez C 2007 Continuous oximetry/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia Anesth. Analg. 105 412-8 (Pubitemid 47196421)
    • (2007) Anesthesia and Analgesia , vol.105 , Issue.2 , pp. 412-418
    • Overdyk, F.J.1    Carter, R.2    Maddox, R.R.3    Callura, J.4    Herrin, A.E.5    Henriquez, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.