Design of a test system for fast time response fibre optic oxygen sensors

Author keywords

Dynamic gas sensor calibration; Fibre optic oxygen sensor; Sensor time response

Indexed keywords

CALIBRATION; FIBER OPTICS; TEMPERATURE SENSORS;

EID: 77949834032     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/31/4/N02     Document Type: Article
Times cited : (12)

References (11)
  • 2
    • 0033903446 scopus 로고    scopus 로고
    • Response-time enhancement of a clinical gas analyzer facilitates measurement of breath-by-breath gas exchange
    • Farmery A D and Hahn C E W 2000 Response-time enhancement of a clinical gas analyzer facilitates measurement of breath-by-breath gas exchange J. Appl. Physiol. 89 581-9
    • (2000) J. Appl. Physiol , vol.89 , pp. 581-589
    • Farmery, A.D.1    Hahn, C.E.W.2
  • 3
    • 0027463129 scopus 로고
    • Optical sensor based on phosphorescence life time quenching and employing a polymer immobilised metalloporphyrin probe
    • Gewehr P M and Delpy D T 1993 Optical sensor based on phosphorescence life time quenching and employing a polymer immobilised metalloporphyrin probe Med. Biol. Eng. Comput. 31 2-10
    • (1993) Med. Biol. Eng. Comput , vol.31 , pp. 2-10
    • Gewehr, P.M.1    Delpy, D.T.2
  • 4
    • 0031812831 scopus 로고    scopus 로고
    • Electrochemical analysis of clinical blood-gases, gases and vapours
    • Hahn C E W 1998 Electrochemical analysis of clinical blood-gases, gases and vapours Analyst 123 57R-86R
    • (1998) Analyst , vol.123
    • Hahn, C.E.W.1
  • 5
    • 0038104352 scopus 로고    scopus 로고
    • Gas exchange modelling: No more gills, please
    • Hahn C E W and Farmery A D 2003 Gas exchange modelling: no more gills, please Br. J. Anaesth. 91 2-15
    • (2003) Br. J. Anaesth , vol.91 , pp. 2-15
    • Hahn, C.E.W.1    Farmery, A.D.2
  • 6
    • 0037706522 scopus 로고
    • Continuous monitoring of PaO2 of intensive care patients in view of its application during prolonged extracorporeal perfusion
    • ed S G Dawids and H C Engell (Amsterdam: Elsevier) pp
    • Kimmich H P and Kreuzer F 1976 Continuous monitoring of PaO2 of intensive care patients in view of its application during prolonged extracorporeal perfusion Physiological and Clinical Aspects of Oxygenator Design ed S G Dawids and H C Engell (Amsterdam: Elsevier) pp 259-68
    • (1976) Physiological and Clinical Aspects of Oxygenator Design , pp. 259-268
    • Kimmich, H.P.1    Kreuzer, F.2
  • 8
    • 0013993463 scopus 로고
    • Fluctuations of arterial oxygen tension which have the same period as respiration
    • Purves M J 1966 Fluctuations of arterial oxygen tension which have the same period as respiration Respir. Physiol. 1 281-96
    • (1966) Respir. Physiol , vol.1 , pp. 281-296
    • Purves, M.J.1
  • 9
    • 2342632481 scopus 로고    scopus 로고
    • Millisecond-order response measurement for fast oxygen gas sensors
    • Shin W, Izu N, Matsubara I and Murayama N 2004 Millisecond-order response measurement for fast oxygen gas sensors Sensors Actuators B 100 395-400
    • (2004) Sensors Actuators B , vol.100 , pp. 395-400
    • Shin, W.1    Izu, N.2    Matsubara, I.3    Murayama, N.4
  • 10
    • 0041519235 scopus 로고    scopus 로고
    • Development of catheter-type optical oxygen sensor and applications to bioinstrumentation
    • Tsukada K, Sakai S, Hase K and Minamitiani H 2003 Development of catheter-type optical oxygen sensor and applications to bioinstrumentation Biosens. Bioelectron. 18 1439-45
    • (2003) Biosens. Bioelectron , vol.18 , pp. 1439-1445
    • Tsukada, K.1    Sakai, S.2    Hase, K.3    Minamitiani, H.4
  • 11
    • 0033623610 scopus 로고    scopus 로고
    • Within-breath arterial PO2 oscillations in an experimental model of acute respiratory distress syndrome
    • Williams E M, Viale J P, Hamilton R M, McPeak H, Sutton L and Hahn C E W 2000 Within-breath arterial PO2 oscillations in an experimental model of acute respiratory distress syndrome Br. J. Anaesth. 85 456-9
    • (2000) Br. J. Anaesth , vol.85 , pp. 456-459
    • Williams, E.M.1    Viale, J.P.2    Hamilton, R.M.3    McPeak, H.4    Sutton, L.5    Hahn, C.E.W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.