-
2
-
-
0022773329
-
Monitoring during MRI. An evaluation of the effect of high-field MRI on various patientmonitors
-
F. G. Shellock, "Monitoring during MRI. An evaluation of the effect of high-field MRI on various patientmonitors," Med. Electron., vol. 17, no. 4, pp. 93-97, 1986.
-
(1986)
Med. Electron
, vol.17
, Issue.4
, pp. 93-97
-
-
Shellock, F.G.1
-
3
-
-
0027603223
-
Sedation, anesthesia and physiologic monitoring during MR imaging: Evaluation of procedures and equipment
-
B. A. Holshouser, D. B. Hinshaw, and F. G. Shellock, "Sedation, anesthesia and physiologic monitoring during MR imaging: Evaluation of procedures and equipment," J. Magn. Reson. Imag., vol. 3, pp. 553-558, 1993.
-
(1993)
J. Magn. Reson. Imag
, vol.3
, pp. 553-558
-
-
Holshouser, B.A.1
Hinshaw, D.B.2
Shellock, F.G.3
-
4
-
-
0033228531
-
The AAPM/RSNA physics tutorial for residents. MR imaging safety considerations
-
R. R. Price, "The AAPM/RSNA physics tutorial for residents. MR imaging safety considerations," Radiographics, vol. 19, no. 6, pp. 1641-1651, 1999.
-
(1999)
Radiographics
, vol.19
, Issue.6
, pp. 1641-1651
-
-
Price, R.R.1
-
5
-
-
0038419585
-
Hazardous situation in the MR bore: Induction in ECG leads causes fire
-
H. Kugel, C. Bremer, M. P̈uschel, R. Fischbach, H. Lenzen, B. Tombach, H. van Aken, and W. Heindel, "Hazardous situation in the MR bore: Induction in ECG leads causes fire," Eur. Radiol., vol. 13, no. 4, pp. 690-694, 2003. (Pubitemid 36790548)
-
(2003)
European Radiology
, vol.13
, Issue.4
, pp. 690-694
-
-
Kugel, H.1
Bremer, C.2
Puschel, M.3
Fischbach, R.4
Lenzen, H.5
Tombach, B.6
Van Aken, H.7
Heindel, W.8
-
6
-
-
84856918214
-
Non-invasive human breath sensor
-
G. Roopa, K. Rajanna, and M. M. Nayak, "Non-invasive human breath sensor," in Proc. IEEE Sensors, 2011, pp. 1788-1791.
-
(2011)
Proc IEEE Sensors
, pp. 1788-1791
-
-
Roopa, G.1
Rajanna, K.2
Nayak, M.M.3
-
7
-
-
33750841716
-
Sensors on textile substrates for home-based healthcare monitoring
-
DOI 10.1109/DDHH.2006.1624783, 1624783, Conference Proceedings - 1st Transdisciplinary Conference on Distributed Diagnosis and Home Healthcare, D2H2 2006
-
T. H. Kang, C. Merritt, B. Karaguzel, J. Wilson, P. Franzon, B. Pourdeyhimi, E. Grant, and T. Nagle, "Sensors on textile substrates for home-based healthcare monitoring," in Proc. 1st Transdisciplinary Conf. Distrib. Diagnosis Home Heathcare, 2006, pp. 5-7. (Pubitemid 44711424)
-
(2006)
Conference Proceedings - 1st Transdisciplinary Conference on Distributed Diagnosis and Home Healthcare, D2H2 2006
, vol.2006
, pp. 5-7
-
-
Kang, T.-H.1
Merritt, C.2
Karaguzel, B.3
Wilson, J.4
Franzon, P.5
Pourdeyhimi, B.6
Grant, E.7
Nagle, T.8
-
8
-
-
84856913581
-
Film-type sensor materials PVDF and EMFi in measurement of cardiorespiratory signals-A review
-
Mar.
-
S. Rajala and J. Lekkala, "Film-type sensor materials PVDF and EMFi in measurement of cardiorespiratory signals-A review," IEEE Sensors J., vol. 12, no. 3, pp. 439-446, Mar. 2012.
-
(2012)
IEEE Sensors J
, vol.12
, Issue.3
, pp. 439-446
-
-
Rajala, S.1
Lekkala, J.2
-
9
-
-
39849108936
-
Mobile noncontact monitoring of heart and lung activity
-
DOI 10.1109/TBCAS.2008.915633
-
M. Steffen, A. Aleksandrowicz, and S. Leonhardt, "Mobile noncontact monitoring of heart and lung activity," IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 4, pp. 250-257, Dec. 2007. (Pubitemid 351314690)
-
(2007)
IEEE Transactions on Biomedical Circuits and Systems
, vol.1
, Issue.4
, pp. 250-257
-
-
Steffen, M.1
Aleksandrowicz, A.2
Leonhardt, S.3
-
10
-
-
0030986596
-
Fibre-optic sensors in health care
-
DOI 10.1088/0031-9155/42/5/015, PII S003191559780694X
-
A. G. Mignani and F. Baldini, "Fibre-optic sensors in health care," Phys. Med. Biol., vol. 42, pp. 967-979, 1997. (Pubitemid 27263511)
-
(1997)
Physics in Medicine and Biology
, vol.42
, Issue.5
, pp. 967-979
-
-
Mignani, A.G.1
Baldini, F.2
-
11
-
-
43649098066
-
Optical fibre sensors embedded intomedical textiles for healthcaremonitoring
-
Jul
-
A. Grillet, D. Kinet, J. Witt, M. Schukar, K. Krebber, F. Pirotte, and A. Depre, "Optical fibre sensors embedded intomedical textiles for healthcaremonitoring," IEEE Sensors J., vol. 8, no. 7, pp. 1215-1222, Jul. 2008.
-
(2008)
IEEE Sensors J
, vol.8
, Issue.7
, pp. 1215-1222
-
-
Grillet, A.1
Kinet, D.2
Witt, J.3
Schukar, M.4
Krebber, K.5
Pirotte, F.6
Depre, A.7
-
12
-
-
84862743716
-
Monitoring respiration and cardiac activity using fiber Bragg grating-based sensor
-
Jul.
-
L. Dzuida, F. W. Skibniewski, M. Krej, and J. Lewandowski, "Monitoring respiration and cardiac activity using fiber Bragg grating-based sensor," IEEE Trans. Biomed. Eng., vol. 59, no. 7, pp. 1934-1942, Jul. 2012.
-
(2012)
IEEE Trans. Biomed. Eng
, vol.59
, Issue.7
, pp. 1934-1942
-
-
Dzuida, L.1
Skibniewski, F.W.2
Krej, M.3
Lewandowski, J.4
-
13
-
-
4043158551
-
A 'smart' bed for non-intrusive monitoring of patient physiological factors
-
DOI 10.1088/0957-0233/15/8/032, PII S0957023304744306, Optical Fibre Sensors 16
-
W. B. Spillman, M. Mayer, J. Bennett, J. Gong, K. E. Meissner, B. Davis, R. O. Claus, A. A. Muelenaer, and X. Xu, "A smart bed for non-intrusive monitoring of patient physiological factors," Meas. Sci. Technol., vol. 15, pp. 1614-1620, 2004. (Pubitemid 39081054)
-
(2004)
Measurement Science and Technology
, vol.15
, Issue.8
, pp. 1614-1620
-
-
Spillman Jr., W.B.1
Mayer, M.2
Bennett, J.3
Gong, J.4
Meissner, K.E.5
Davis, B.6
Claus, R.O.7
Muelenaer Jr., A.A.8
Xu, X.9
-
14
-
-
0026674358
-
Monitoring of respiratory and heart rates using a fibre-optic sensor
-
L. G. Lindberg,H.Ugnell, and P. A.Oberg, "Monitoring of respiratory and heart rates using a fibre-optic sensor," Med. Biol. Eng. Comput., vol. 30, pp. 533-537, 1992.
-
(1992)
Med. Biol. Eng. Comput
, vol.30
, pp. 533-537
-
-
Lindberg, L.G.1
Ugnell, H.2
Oberg, P.A.3
-
15
-
-
0029343975
-
Historical review of microbend fibre-optic sensors
-
J. W. Berthold, "Historical review of microbend fibre-optic sensors," J. Lightw. Technol., vol. 13, pp. 1193-1199, 1995.
-
(1995)
J. Lightw. Technol
, vol.13
, pp. 1193-1199
-
-
Berthold, J.W.1
-
16
-
-
0036570994
-
A microbend fibre optic pH sensor
-
S. T. Lee, B. Aneeshkumar, P. Radhakrishnan, C. P. G. Vallabhan, and V. P. N. Nampoori, "A microbend fibre optic pH sensor," Opt. Commun., vol. 205, pp. 253-256, 2002.
-
(2002)
Opt. Commun
, vol.205
, pp. 253-256
-
-
Lee, S.T.1
Aneeshkumar, B.2
Radhakrishnan, P.3
Vallabhan, C.P.G.4
Nampoori, V.P.N.5
-
17
-
-
34547402443
-
A plastic optical fiber microbend sensor used as a low-cost anti-squeeze detector
-
DOI 10.1109/JSEN.2007.901252
-
M. Linec and D. Donlagic, "A plastic optical fiber microbend sensor used as low cost anti-squeeze detector," IEEE Sensors J., vol. 7, no. 9, pp. 1262-1267, Sep. 2007. (Pubitemid 47171269)
-
(2007)
IEEE Sensors Journal
, vol.7
, Issue.9
, pp. 1262-1267
-
-
Linec, M.1
Donlagic, D.2
-
18
-
-
65349136413
-
In-bed fibre optic breathing and movement sensor for non-intrusive monitoring
-
I. Gannot ed., Proc. SPIE
-
Z. H. Chen, J. T. Teo, and X. F. Yang, "In-bed fibre optic breathing and movement sensor for non-intrusive monitoring," in Optical Fibers and Sensors for MedicalDiagnostics and Treatment Applications IX, I. Gannot ed., Proc. SPIE, 2009, vol. 7173, pp. 71730P-1-71730P-6.
-
(2009)
Optical Fibers and Sensors for MedicalDiagnostics and Treatment Applications IX
, vol.7173
-
-
Chen, Z.H.1
Teo, J.T.2
Yang, X.F.3
-
19
-
-
79954545687
-
Smart pillow for heart rate monitoring using a fiber optic sensor
-
I. Gannot ed., Proc. SPIE
-
Z. H. Chen, J. T. Teo, S. H. Ng, and H. Q. Yim, "Smart pillow for heart rate monitoring using a fiber optic sensor," in Optical Fibers, Sensors, and Devices for Biomedical Diagnostics and Treatment XI, I. Gannot ed., Proc. SPIE, 2011, vol. 7894, pp. 789402-1-789402-7.
-
(2011)
Optical Fibers, Sensors, and Devices for Biomedical Diagnostics and Treatment XI
, vol.7894
, pp. 7894021-7894027
-
-
Chen, Z.H.1
Teo, J.T.2
Ng, S.H.3
Yim, H.Q.4
-
20
-
-
84861982828
-
Portable fiber optic ballistocardiogram sensor for home use
-
I. Gannot ed., Proc. SPIE
-
Z. H. Chen, J. T. Teo, S. H. Ng, and X. F. Yang, "Portable fiber optic ballistocardiogram sensor for home use," in Optical Fibers and Sensors for Medical Diagnostics and Treatment Applications XII, I. Gannot ed., Proc. SPIE, 2012, vol. 8218, pp. 82180X-1-82180X-7.
-
(2012)
Optical Fibers and Sensors for Medical Diagnostics and Treatment Applications XII
, vol.8218
-
-
Chen, Z.H.1
Teo, J.T.2
Ng, S.H.3
Yang, X.F.4
-
21
-
-
0023245616
-
Microbend fiber-optic sensor
-
N. Lagakos, J. H. Cole, and J. A. Bucaro, "Microbend fiber-optic sensor," Appl. Opt., vol. 26, no. 11, pp. 2181-2180, 1987.
-
(1987)
Appl. Opt
, vol.26
, Issue.11
, pp. 2181-2180
-
-
Lagakos, N.1
Cole, J.H.2
Bucaro, J.A.3
-
22
-
-
84883009450
-
Evaluation report: Comparing the use of I2R's SleepMonitor i with conventional thoracic belts in the assessment of respiratory effort, during polysomnography (PSG)
-
Nov
-
M. Tong, T. B. Choo, and A. P. Chua, "Evaluation report: Comparing the use of I2R's SleepMonitor I with conventional thoracic belts in the assessment of respiratory effort, during polysomnography (PSG)," National University Hospital Clinical Report, pp. 1-6, Nov. 5, 2012.
-
(2012)
National University Hospital Clinical Report
, vol.5
, pp. 1-6
-
-
Tong, M.1
Choo, T.B.2
Chua, A.P.3
-
23
-
-
33751223892
-
Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: Feasibility study
-
DOI 10.2214/AJR.05.1032
-
J. Zhang, G. M. Israel, E. M. Hecht, G. A. Krinsky, J. S. Babb, and V. S. Lee, "Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: Feasibility study," Amer. J. Roentgenol., vol. 187, pp. 1564-1570, 2006. (Pubitemid 44788688)
-
(2006)
American Journal of Roentgenology
, vol.187
, Issue.6
, pp. 1564-1570
-
-
Zhang, J.1
Israel, G.M.2
Hecht, E.M.3
Krinsky, G.A.4
Babb, J.S.5
Lee, V.S.6
-
24
-
-
0031412991
-
MR navigator-echo monitoring of temporal changes in diaphragm position: Implications for MR coronary angiography
-
DOI 10.1002/jmri.1880070404
-
A. M. Taylor, P. Jhooti, F. Wiesmann, J. Keegan, D. N. Firmin, and D. J. Pennell, "MR navigator-echo monitoring of temporal changes in diaphragm position: Implications for MR coronary angiography," J. Magn. Reson. Imag., vol. 7, no. 4, pp. 629-636, 1997. (Pubitemid 28365609)
-
(1997)
Journal of Magnetic Resonance Imaging
, vol.7
, Issue.4
, pp. 629-636
-
-
Taylor, A.M.1
Jhooti, P.2
Wiesmann, F.3
Keegan, J.4
Firmin, D.N.5
Pennell, D.J.6
-
25
-
-
0036184676
-
Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: Implications for slice-followed coronary artery imaging
-
DOI 10.1002/mrm.10069
-
J. Keegan, P. Gatehouse, G. Yang, and D. Firmin, "Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: Implications for slice-followed coronary artery imaging," Magn. Reson. Med., vol. 47, no. 3, pp. 476-481, 2002. (Pubitemid 34194002)
-
(2002)
Magnetic Resonance in Medicine
, vol.47
, Issue.3
, pp. 476-481
-
-
Keegan, J.1
Gatehouse, P.2
Yang, G.-Z.3
Firmin, D.4
-
26
-
-
40249108457
-
Medical applications: Saving lives
-
̀ E. Pinet, "Medical applications: Saving lives," Nature Photon., vol. 2, pp. 150-152, 2008.
-
(2008)
Nature Photon
, vol.2
, pp. 150-152
-
-
Pinet, E.1
|