메뉴 건너뛰기




Volumn 7894, Issue , 2011, Pages

Smart pillow for heart-rate monitoring using a fiber optic sensor

Author keywords

ballistocardiography; fiber optic sensor; heart rate; non intrusive monitoring

Indexed keywords

BALLISTOCARDIOGRAPHY; FIELD TRIAL; HEART RATES; HEART-RATE MONITORING; MICRO-BENDING; NATIONAL INSTRUMENTS; NON-INTRUSIVE; SENSING SYSTEMS;

EID: 79954545687     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.871208     Document Type: Conference Paper
Times cited : (11)

References (9)
  • 2
    • 0345435955 scopus 로고    scopus 로고
    • Two electrode telemetric instrument for infant heart rate and apnea monitoring
    • D Dobrev, I Daskalov, "Two electrode telemetric instrument for infant heart rate and apnea monitoring", Med. Eng. Phys., 20(10), 729-734 (1998).
    • (1998) Med. Eng. Phys. , vol.20 , Issue.10 , pp. 729-734
    • Dobrev, D.1    Daskalov, I.2
  • 3
    • 57649228936 scopus 로고    scopus 로고
    • FFT averaging of multi channel BCG signals from bed mattress sensor to improve estimation of heart beat interval
    • J M Kortelainen and J Virkkala, "FFT averaging of multi channel BCG signals from bed mattress sensor to improve estimation of heart beat interval", IEEE Proc EMBC'07, 23-26 (2007).
    • (2007) IEEE Proc EMBC'07 , pp. 23-26
    • Kortelainen, J.M.1    Virkkala, J.2
  • 5
    • 61849174134 scopus 로고    scopus 로고
    • Unconstrained respiration and heart rate monitoring system based on a PPG pillow during sleep
    • J Y Cha, H S Choi, J Y Shin, and K J Lee, "Unconstrained respiration and heart rate monitoring system based on a PPG pillow during sleep", IEEE Proc EMBC'08, 20-24 (2008).
    • (2008) IEEE Proc EMBC'08 , pp. 20-24
    • Cha, J.Y.1    Choi, H.S.2    Shin, J.Y.3    Lee, K.J.4
  • 8
    • 63449138477 scopus 로고    scopus 로고
    • Development and preliminary validation of heart rate and breathing rate detection using a passive, Ballistocardiography-based sleep monitoring system
    • D C Mack, J T Patrie, P M Suratt, R A Felder, and M Alwan, "Development and preliminary validation of heart rate and breathing rate detection using a passive, Ballistocardiography-based sleep monitoring system", IEEE Trans., Inf. Technol. Biomed., 13(1): 111-120 (2009).
    • (2009) IEEE Trans., Inf. Technol. Biomed. , vol.13 , Issue.1 , pp. 111-120
    • Mack, D.C.1    Patrie, J.T.2    Suratt, P.M.3    Felder, R.A.4    Alwan, M.5
  • 9
    • 0029343975 scopus 로고
    • Historical review of microbend fibre-optic senosrs
    • J W Berthold, "Historical review of microbend fibre-optic senosrs", J LIGHTWAVE TECHNOL, 13(7), pp. 1193-1199 (1995).
    • (1995) J Lightwave Technol , vol.13 , Issue.7 , pp. 1193-1199
    • Berthold, J.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.