메뉴 건너뛰기




Volumn , Issue , 2012, Pages 3001-3004

A precise charge balancing and compliance voltage monitoring stimulator front-end for 1024-electrodes retinal prosthesis

Author keywords

[No Author keywords available]

Indexed keywords

ALARM SIGNALS; CHARGE BALANCING; CMOS PROCESSS; CURRENT PULSE; DYNAMIC CURRENT; ELECTRODE-TISSUE INTERFACE; LOW-VOLTAGE; ON CURRENTS; RETINAL PROSTHESIS; TISSUE IMPEDANCES; VOLTAGE COMPLIANCE; VOLTAGE MONITORING;

EID: 84882944289     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2012.6346595     Document Type: Conference Paper
Times cited : (7)

References (9)
  • 1
    • 29344473089 scopus 로고    scopus 로고
    • Architecture tradeoffs in high-density microstimulators for retinal prosthesis
    • IEEE Transactions on
    • M. Sivaprakasam, W. Liu, G. Wang, J. Weiland, and M. Humayun, "Architecture tradeoffs in high-density microstimulators for retinal prosthesis," Circuits and Systems I: Regular Papers, IEEE Transactions on, vol. 52, no. 12, pp. 2629-2641, 2005.
    • (2005) Circuits and Systems I: Regular Papers , vol.52 , Issue.12 , pp. 2629-2641
    • Sivaprakasam, M.1    Liu, W.2    Wang, G.3    Weiland, J.4    Humayun, M.5
  • 4
    • 0026637520 scopus 로고
    • Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
    • K. Cha, K. Horch, and R. Normann, "Simulation of a phosphene-based visual field: visual acuity in a pixelized vision system," Annals of biomedical engineering, vol. 20, no. 4, pp. 439-449, 1992.
    • (1992) Annals of Biomedical Engineering , vol.20 , Issue.4 , pp. 439-449
    • Cha, K.1    Horch, K.2    Normann, R.3
  • 5
    • 67649964988 scopus 로고    scopus 로고
    • First results of a study on a completely implanted retinal prosthesis in blind humans
    • IEEE
    • C. Koch, W. Mokwa, M. Goertz, and P. Walter, "First results of a study on a completely implanted retinal prosthesis in blind humans," in Sensors, 2008 IEEE. IEEE, 2008, pp. 1237-1240.
    • (2008) Sensors, 2008 IEEE , pp. 1237-1240
    • Koch, C.1    Mokwa, W.2    Goertz, M.3    Walter, P.4
  • 7
    • 77954402649 scopus 로고    scopus 로고
    • A flexible electrode Driver using 65 nm cmos process for 1024-electrode epi-retinal prosthesis
    • 2010 5th International Conference on. IEEE
    • N. Tran, J. Yang, S. Bai, E. Skafidas, I. Mareels, D. Ng, and M. Halpern, "A flexible electrode driver using 65 nm cmos process for 1024-electrode epi-retinal prosthesis," in Future Information Technology (FutureTech), 2010 5th International Conference on. IEEE, 2010, pp. 1-5.
    • (2010) Future Information Technology (FutureTech) , pp. 1-5
    • Tran, N.1    Yang, J.2    Bai, S.3    Skafidas, E.4    Mareels, I.5    Ng, D.6    Halpern, M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.