메뉴 건너뛰기




Volumn 46, Issue 13-14, 2013, Pages 1197-1219

CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: Direct validation using reference samples from the CALIPER cohort

Author keywords

Abbott; Beckman; Biochemical markers; CALIPER; Ortho; Pediatric; Reference intervals; Roche; Siemens; Transference

Indexed keywords

ARTICLE; ASSAY; CLINICAL CHEMISTRY; COHORT ANALYSIS; DATA BASE; PRACTICE GUIDELINE; PRIORITY JOURNAL; QUALITY CONTROL; REFERENCE VALUE; VALIDATION PROCESS; DRUG INDUSTRY; FACTUAL DATABASE; HUMAN; PEDIATRICS; STANDARD;

EID: 84882889981     PISSN: 00099120     EISSN: 18732933     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2013.04.001     Document Type: Article
Times cited : (84)

References (25)
  • 1
    • 84895779668 scopus 로고    scopus 로고
    • CLSI Defining, establishing, and verifying reference intervals in the clinical laboratory; approved guideline
    • [Wayne (PA)]
    • CLSI Defining, establishing, and verifying reference intervals in the clinical laboratory; approved guideline. CLSI document C28-A3 2008, [Wayne (PA)]. 3rd ed.
    • (2008) CLSI document C28-A3
  • 2
    • 4344578953 scopus 로고    scopus 로고
    • Selecting clinically relevant populations for reference intervals
    • Ritchie R.F., Palomaki G. Selecting clinically relevant populations for reference intervals. Clin Chem Lab Med 2004, 42(7):702-709.
    • (2004) Clin Chem Lab Med , vol.42 , Issue.7 , pp. 702-709
    • Ritchie, R.F.1    Palomaki, G.2
  • 3
    • 84860653919 scopus 로고    scopus 로고
    • Closing the gaps in pediatric laboratory reference intervals: a CALIPER database of 40 biochemical markers in a healthy and multiethnic population of children
    • Colantonio D.A., Kyriakopoulou L., Chan M.K., Daly C.H., Brinc D., Venner A.A., et al. Closing the gaps in pediatric laboratory reference intervals: a CALIPER database of 40 biochemical markers in a healthy and multiethnic population of children. Clin Chem 2012, 58(5):854-868.
    • (2012) Clin Chem , vol.58 , Issue.5 , pp. 854-868
    • Colantonio, D.A.1    Kyriakopoulou, L.2    Chan, M.K.3    Daly, C.H.4    Brinc, D.5    Venner, A.A.6
  • 4
    • 33745189134 scopus 로고    scopus 로고
    • Gap analysis of pediatric reference intervals for risk biomarkers of cardiovascular disease and the metabolic syndrome
    • Mansoub S., Chan M.K., Adeli K. Gap analysis of pediatric reference intervals for risk biomarkers of cardiovascular disease and the metabolic syndrome. Clin Biochem 2006, 39(6):569-587.
    • (2006) Clin Biochem , vol.39 , Issue.6 , pp. 569-587
    • Mansoub, S.1    Chan, M.K.2    Adeli, K.3
  • 5
    • 33745205625 scopus 로고    scopus 로고
    • Gap analysis of pediatric reference intervals related to thyroid hormones and the growth hormone-insulin growth factor axis
    • Delvin E.E., Laxmi Grey V., Vergee Z. Gap analysis of pediatric reference intervals related to thyroid hormones and the growth hormone-insulin growth factor axis. Clin Biochem 2006, 39(6):588-594.
    • (2006) Clin Biochem , vol.39 , Issue.6 , pp. 588-594
    • Delvin, E.E.1    Laxmi Grey, V.2    Vergee, Z.3
  • 6
    • 33745211222 scopus 로고    scopus 로고
    • Incomplete pediatric reference intervals for the management of patients with inborn errors of metabolism
    • Lepage N., Li D., Kavsak P.A., Bamforth F., Callahan J., Dooley K., et al. Incomplete pediatric reference intervals for the management of patients with inborn errors of metabolism. Clin Biochem 2006, 39(6):595-599.
    • (2006) Clin Biochem , vol.39 , Issue.6 , pp. 595-599
    • Lepage, N.1    Li, D.2    Kavsak, P.A.3    Bamforth, F.4    Callahan, J.5    Dooley, K.6
  • 7
    • 33745203732 scopus 로고    scopus 로고
    • Pediatric reference intervals for bone markers
    • Yang L., Grey V. Pediatric reference intervals for bone markers. Clin Biochem 2006, 39(6):561-568.
    • (2006) Clin Biochem , vol.39 , Issue.6 , pp. 561-568
    • Yang, L.1    Grey, V.2
  • 8
    • 0027618636 scopus 로고
    • American Academy of Pediatrics AAP Section on Endocrinology and Committee on Genetics, American Thyroid Association Committee on Public Health
    • American Academy of Pediatrics AAP Section on Endocrinology and Committee on Genetics, American Thyroid Association Committee on Public Health Newborn screening for congenital hypothyroidism: recommended guidelines. Pediatrics 1993, 91(6):1203-1209.
    • (1993) Newborn screening for congenital hypothyroidism: recommended guidelines, Pediatrics , vol.91 , Issue.6 , pp. 1203-1209
  • 9
    • 31644449677 scopus 로고    scopus 로고
    • False-positive results in neonatal screening for cystic fibrosis based on a three-stage protocol (IRT/DNA/IRT): Should we adjust IRT cut-off to ethnic origin?
    • Cheillan D., Vercherat M., Chevalier-Porst F., Charcosset M., Rolland M.O., Dorche C. False-positive results in neonatal screening for cystic fibrosis based on a three-stage protocol (IRT/DNA/IRT): Should we adjust IRT cut-off to ethnic origin?. J Inherit Metab Dis 2005, 28(6):813-818.
    • (2005) J Inherit Metab Dis , vol.28 , Issue.6 , pp. 813-818
    • Cheillan, D.1    Vercherat, M.2    Chevalier-Porst, F.3    Charcosset, M.4    Rolland, M.O.5    Dorche, C.6
  • 10
    • 33745535877 scopus 로고    scopus 로고
    • Plasma concentrations of N-terminal brain natriuretic peptide in healthy children, adolescents, and young adults: effect of age and gender
    • Mir T.S., Flato M., Falkenberg J., Haddad M., Budden R., Weil J., et al. Plasma concentrations of N-terminal brain natriuretic peptide in healthy children, adolescents, and young adults: effect of age and gender. Pediatr Cardiol 2006, 27(1):73-77.
    • (2006) Pediatr Cardiol , vol.27 , Issue.1 , pp. 73-77
    • Mir, T.S.1    Flato, M.2    Falkenberg, J.3    Haddad, M.4    Budden, R.5    Weil, J.6
  • 11
    • 39049120439 scopus 로고    scopus 로고
    • Resetting the detection level of cord blood thyroid stimulating hormone (TSH) for the diagnosis of congenital hypothyroidism
    • Ogunkeye O.O., Roluga A.I., Khan F.A. Resetting the detection level of cord blood thyroid stimulating hormone (TSH) for the diagnosis of congenital hypothyroidism. J Trop Pediatr 2008, 54(1):74-77.
    • (2008) J Trop Pediatr , vol.54 , Issue.1 , pp. 74-77
    • Ogunkeye, O.O.1    Roluga, A.I.2    Khan, F.A.3
  • 12
    • 84860688864 scopus 로고    scopus 로고
    • Establishing pediatric reference intervals: a challenging task
    • Ceriotti F. Establishing pediatric reference intervals: a challenging task. Clin Chem 2012, 58(5):808-810.
    • (2012) Clin Chem , vol.58 , Issue.5 , pp. 808-810
    • Ceriotti, F.1
  • 13
    • 33745220967 scopus 로고    scopus 로고
    • Pediatric reference intervals: critical gap analysis and establishment of a national initiative
    • Pediatric reference intervals: critical gap analysis and establishment of a national initiative. Clin Biochem 2006, 39(6):559-560.
    • (2006) Clin Biochem , vol.39 , Issue.6 , pp. 559-560
  • 14
    • 79955141332 scopus 로고    scopus 로고
    • Closing the gaps in pediatric reference intervals: the CALIPER initiative
    • Adeli K. Closing the gaps in pediatric reference intervals: the CALIPER initiative. Clin Biochem 2011, 44(7):480-482.
    • (2011) Clin Biochem , vol.44 , Issue.7 , pp. 480-482
    • Adeli, K.1
  • 15
    • 84882851704 scopus 로고    scopus 로고
    • CLSI Method Comparison and Bias Estimation Using Patient Samples; Approved Guideline
    • [Wayne (PA)]
    • CLSI Method Comparison and Bias Estimation Using Patient Samples; Approved Guideline. CLSI document EP9-A2 2002, [Wayne (PA)]. 2nd ed.
    • (2002) CLSI document EP9-A2
  • 16
    • 0037402916 scopus 로고    scopus 로고
    • Evaluation of the Dade Behring Dimension RxL: integrated chemistry system-pediatric reference ranges
    • Ghoshal A.K., Soldin S.J. Evaluation of the Dade Behring Dimension RxL: integrated chemistry system-pediatric reference ranges. Clin Chim Acta 2003, 331(1-2):135-146.
    • (2003) Clin Chim Acta , vol.331 , Issue.1-2 , pp. 135-146
    • Ghoshal, A.K.1    Soldin, S.J.2
  • 17
    • 0031751341 scopus 로고    scopus 로고
    • Transference of reference intervals in the validation of automated chemiluminescent immunoassays on a new platform
    • Lynch M., Thompson A., Gaumond B., Kilroy J., Leonard H., Jacob A., et al. Transference of reference intervals in the validation of automated chemiluminescent immunoassays on a new platform. Clin Chem 1998, 44(9):2061-2063.
    • (1998) Clin Chem , vol.44 , Issue.9 , pp. 2061-2063
    • Lynch, M.1    Thompson, A.2    Gaumond, B.3    Kilroy, J.4    Leonard, H.5    Jacob, A.6
  • 19
    • 0002339335 scopus 로고
    • Graphs in Statistical Analysis
    • Anscombe F.J. Graphs in Statistical Analysis. Am Stat 1973, 27(1):17-21.
    • (1973) Am Stat , vol.27 , Issue.1 , pp. 17-21
    • Anscombe, F.J.1
  • 20
    • 0027405311 scopus 로고
    • Clinical and analytical evaluation of a continuous enzymatic method for measuring pancreatic lipase activity
    • Panteghini M., Pagani F., Bonora R. Clinical and analytical evaluation of a continuous enzymatic method for measuring pancreatic lipase activity. Clin Chem 1993, 39(2):304-308.
    • (1993) Clin Chem , vol.39 , Issue.2 , pp. 304-308
    • Panteghini, M.1    Pagani, F.2    Bonora, R.3
  • 21
    • 0027238611 scopus 로고
    • Lipase in serum-the elusive enzyme: an overview
    • Tietz N.W., Shuey D.F. Lipase in serum-the elusive enzyme: an overview. Clin Chem 1993, 39(5):746-756.
    • (1993) Clin Chem , vol.39 , Issue.5 , pp. 746-756
    • Tietz, N.W.1    Shuey, D.F.2
  • 22
    • 0034941347 scopus 로고    scopus 로고
    • Measurement of pancreatic lipase activity in serum by a kinetic colorimetric assay using a new chromogenic substrate
    • Panteghini M., Bonora R., Pagani F. Measurement of pancreatic lipase activity in serum by a kinetic colorimetric assay using a new chromogenic substrate. Ann Clin Biochem 2001, 38(Pt 4):365-370.
    • (2001) Ann Clin Biochem , vol.38 , Issue.PART 4 , pp. 365-370
    • Panteghini, M.1    Bonora, R.2    Pagani, F.3
  • 23
    • 0028179990 scopus 로고
    • International Federation of Clinical Chemistry standardization project for measurements of apolipoproteins A-I and B. IV. Comparability of apolipoprotein B values by use of International Reference Material
    • Marcovina S.M., Albers J.J., Kennedy H., Mei J.V., Henderson L.O., Hannon W.H. International Federation of Clinical Chemistry standardization project for measurements of apolipoproteins A-I and B. IV. Comparability of apolipoprotein B values by use of International Reference Material. Clin Chem 1994, 40(4):586-592.
    • (1994) Clin Chem , vol.40 , Issue.4 , pp. 586-592
    • Marcovina, S.M.1    Albers, J.J.2    Kennedy, H.3    Mei, J.V.4    Henderson, L.O.5    Hannon, W.H.6
  • 24
    • 70350360003 scopus 로고    scopus 로고
    • 2009 Canadian Cardiovascular Society/Canadian guidelines for the diagnosis and treatment of dyslipidemia and prevention of cardiovascular disease in the adult - 2009 recommendations
    • Genest J., McPherson R., Frohlich J., Anderson T., Campbell N., Carpentier A., et al. 2009 Canadian Cardiovascular Society/Canadian guidelines for the diagnosis and treatment of dyslipidemia and prevention of cardiovascular disease in the adult - 2009 recommendations. Can J Cardiol 2009, 25(10):567-579.
    • (2009) Can J Cardiol , vol.25 , Issue.10 , pp. 567-579
    • Genest, J.1    McPherson, R.2    Frohlich, J.3    Anderson, T.4    Campbell, N.5    Carpentier, A.6
  • 25
    • 0019418849 scopus 로고
    • Estimation, prevention, and quality control of carbon dioxide loss during aerobic sample processing
    • Bandi Z.L. Estimation, prevention, and quality control of carbon dioxide loss during aerobic sample processing. Clin Chem 1981, 27(10):1676-1681.
    • (1981) Clin Chem , vol.27 , Issue.10 , pp. 1676-1681
    • Bandi, Z.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.