메뉴 건너뛰기




Volumn 7, Issue 1, 2013, Pages 62-71

Fluorescence intensity- and lifetime-based glucose sensing using glucose/galactose-binding protein

Author keywords

Continuous glucose monitoring; Diabetes; Fluorescence; Glucose sensor; Glucose galactose binding protein

Indexed keywords

BADAN; FLUORESCENT DYE; GALAPTIN; UNCLASSIFIED DRUG; CALCIUM BINDING PROTEIN; GALACTOSE-BINDING PROTEIN; GLUCOSE; GLUCOSE TRANSPORTER; PERIPLASMIC BINDING PROTEIN;

EID: 84882811975     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229681300700108     Document Type: Conference Paper
Times cited : (26)

References (41)
  • 4
    • 79960319709 scopus 로고    scopus 로고
    • Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: Meta-analysis of randomised controlled trials using individual patient data
    • Pickup JC, Freeman SC, Sutton AJ. Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data. BMJ. 2011;343:d3805.
    • (2011) BMJ , vol.343
    • Pickup, J.C.1    Freeman, S.C.2    Sutton, A.J.3
  • 5
    • 79959616082 scopus 로고    scopus 로고
    • Closed-loop insulin delivery: From bench to clinical practice
    • Hovorka R. Closed-loop insulin delivery: from bench to clinical practice. Nat Rev Endocrinol. 2011;7(7):385-95.
    • (2011) Nat Rev Endocrinol , vol.7 , Issue.7 , pp. 385-395
    • Hovorka, R.1
  • 6
    • 84855888268 scopus 로고    scopus 로고
    • Non-invasive methods of glucose measurement: Current status and future perspectives
    • Ciudin A, Hernandez C, Simo R. Non-invasive methods of glucose measurement: current status and future perspectives. Curr Diabetes Rev. 2012;8(1):48-54.
    • (2012) Curr Diabetes Rev , vol.8 , Issue.1 , pp. 48-54
    • Ciudin, A.1    Hernandez, C.2    Simo, R.3
  • 9
    • 0035872921 scopus 로고    scopus 로고
    • Near-infrared fluorescence lifetime assay for serum glucose based on allophycocyanin-labeled concanavalin A
    • DOI 10.1006/abio.2001.5060
    • McCartney LJ, Pickup JC, Rolinski OJ, Birch DJS. Near-infrared fluorescence lifetime assay for serum glucose based on allophycocyanin-labeled concanavalin A. Anal Biochem. 2001;292(2):216-21. (Pubitemid 32458087)
    • (2001) Analytical Biochemistry , vol.292 , Issue.2 , pp. 216-221
    • McCartney, L.J.1    Pickup, J.C.2    Rolinski, O.J.3    Birch, D.J.S.4
  • 10
    • 0000407406 scopus 로고
    • Fiber optic biosensors based on fluorescence resonance energy transfer
    • Meadows D, Schulz JS. Fiber optic biosensors based on fluorescence resonance energy transfer. Talanta. 1988;35(2):145-50.
    • (1988) Talanta , vol.35 , Issue.2 , pp. 145-150
    • Meadows, D.1    Schulz, J.S.2
  • 11
    • 0033600715 scopus 로고    scopus 로고
    • The fluorescence emission of the apo-glucose oxidase from Aspergillus niger as probe to estimate glucose concentrations
    • DOI 10.1006/bbrc.1999.1330
    • D'Auria S, Herman P, Rossi M, Lakowicz JR. The fluorescence emission of the apo-glucose oxidase from Aspergillus niger as probe to estimate glucose concentrations. Biochem Biophys Res Commun. 1999;263(2):550-3. (Pubitemid 29467232)
    • (1999) Biochemical and Biophysical Research Communications , vol.263 , Issue.2 , pp. 550-553
    • D'Auria, S.1    Herman, P.2    Rossi, M.3    Lakowicz, J.R.4
  • 12
    • 14844314461 scopus 로고    scopus 로고
    • Glucose sensing based on the intrinsic fluorescence of sol-gel immobilized yeast hexokinase
    • DOI 10.1016/j.ab.2005.01.016
    • Hussain F, Birch DJ, Pickup JC. Glucose sensing based on the intrinsic fluorescence of sol-gel immobilized yeast hexokinase. Anal Biochem. 2005;339(1):137-43. (Pubitemid 40342688)
    • (2005) Analytical Biochemistry , vol.339 , Issue.1 , pp. 137-143
    • Hussain, F.1    Birch, D.J.S.2    Pickup, J.C.3
  • 13
    • 0029902912 scopus 로고    scopus 로고
    • Saccharide sensing with molecular receptors based on boronic acid
    • James TD, Sandanayake KR, Shinkai S. Saccharide sensing with molecular receptors based on boronic acid. Angew Chem Intl Ed Engl. 1996;35:1910-22.
    • (1996) Angew Chem Intl Ed Engl , vol.35 , pp. 1910-1922
    • James, T.D.1    Sandanayake, K.R.2    Shinkai, S.3
  • 14
    • 0035879464 scopus 로고    scopus 로고
    • Evaluation of two synthetic glucose probes for fluorescence-lifetime- based sensing
    • DOI 10.1006/abio.2001.5170
    • DiCesare N, Lakowicz JR. Evaluation of two synthetic glucose probes for fluorescence-lifetime-based sensing. Anal Biochem. 2001;294(2):154-60. (Pubitemid 32641761)
    • (2001) Analytical Biochemistry , vol.294 , Issue.2 , pp. 154-160
    • DiCesare, N.1    Lakowicz, J.R.2
  • 15
    • 36049012688 scopus 로고    scopus 로고
    • Fluorescence-based sensing of glucose using engineered glucose/galactose-binding protein: A comparison of fluorescence resonance energy transfer and environmentally sensitive dye labelling strategies
    • DOI 10.1016/j.bbrc.2007.10.129, PII S0006291X07023091
    • Khan F, Gnudi L, Pickup JC. Fluorescence-based sensing of glucose using engineered glucose/galactose-binding protein: a comparison of fluorescence resonance energy transfer and environmentally sensitive dye labelling strategies. Biochem Biophys Res Commun. 2008;365(1):102-6. (Pubitemid 350102458)
    • (2008) Biochemical and Biophysical Research Communications , vol.365 , Issue.1 , pp. 102-106
    • Khan, F.1    Gnudi, L.2    Pickup, J.C.3
  • 16
    • 67349210316 scopus 로고    scopus 로고
    • Fluorescence lifetime spectroscopy and imaging of nano-engineered glucose sensor microcapsules based on glucose/galactose-binding protein
    • Saxl T, Khan F, Matthews DR, Zhi ZL, Rolinski O, Ameer-Beg S, Pickup J. Fluorescence lifetime spectroscopy and imaging of nano-engineered glucose sensor microcapsules based on glucose/galactose-binding protein. Biosens Bioelectron. 2009;24(11):3229-34.
    • (2009) Biosens Bioelectron , vol.24 , Issue.11 , pp. 3229-3234
    • Saxl, T.1    Khan, F.2    Matthews, D.R.3    Zhi, Z.L.4    Rolinski, O.5    Ameer-Beg, S.6    Pickup, J.7
  • 17
    • 77649183950 scopus 로고    scopus 로고
    • Fluorescence intensity- and lifetime-based glucose sensing using an engineered high-Kd mutant of glucose/galactose-binding protein
    • Khan F, Saxl TE, Pickup JC. Fluorescence intensity- and lifetime-based glucose sensing using an engineered high-Kd mutant of glucose/galactose-binding protein. Anal Biochem. 2010;399(1):39-43.
    • (2010) Anal Biochem , vol.399 , Issue.1 , pp. 39-43
    • Khan, F.1    Saxl, T.E.2    Pickup, J.C.3
  • 18
    • 79951642763 scopus 로고    scopus 로고
    • A fluorescence lifetime-based fibre-optic glucose sensor using glucose/galactose-binding protein
    • Saxl T, Khan F, Ferla M, Birch D, Pickup J. A fluorescence lifetime-based fibre-optic glucose sensor using glucose/galactose-binding protein. Analyst. 2011;136(5):968-72.
    • (2011) Analyst , vol.136 , Issue.5 , pp. 968-972
    • Saxl, T.1    Khan, F.2    Ferla, M.3    Birch, D.4    Pickup, J.5
  • 19
    • 4143115810 scopus 로고    scopus 로고
    • Periplasmic binding proteins: A versatile superfamily for protein engineering
    • DOI 10.1016/j.sbi.2004.07.004, PII S0959440X04001113
    • Dwyer MA, Hellinga HW. Periplasmic binding proteins: a versatile superfamily for protein engineering. Curr Opin Struct Biol. 2004;14(4):495-504. (Pubitemid 39094355)
    • (2004) Current Opinion in Structural Biology , vol.14 , Issue.4 , pp. 495-504
    • Dwyer, M.A.1    Hellinga, H.W.2
  • 20
    • 34249781722 scopus 로고    scopus 로고
    • Conformational changes of glucose/galactose-binding protein illuminated by open, unliganded, and ultra-high-resolution ligand-bound structures
    • DOI 10.1110/ps.062707807
    • Borrok MJ, Kiessling LL, Forest KT. Conformational changes of glucose/galactose-binding protein illuminated by open, unliganded, and ultra-high-resolution ligand-bound structures. Protein Sci. 2007;16(6):1032-41. (Pubitemid 46849213)
    • (2007) Protein Science , vol.16 , Issue.6 , pp. 1032-1041
    • Borrok, M.J.1    Kiessling, L.L.2    Forest, K.T.3
  • 21
    • 84900526644 scopus 로고    scopus 로고
    • Engineering periplasmic ligand binding proteins as glucose nanosensors
    • Jeffrey CJ. Engineering periplasmic ligand binding proteins as glucose nanosensors. Nano Rev. 2011;2.
    • (2011) Nano Rev , vol.2
    • Jeffrey, C.J.1
  • 22
    • 84858698113 scopus 로고    scopus 로고
    • Reagentless fluorescent biosensors based on proteins for continuous monitoring systems
    • Galbán J, Sanz-Vicente I, Ortega E, del Barrio M, de Marcos S. Reagentless fluorescent biosensors based on proteins for continuous monitoring systems. Anal Bioanal Chem. 2012;402(10):3039-54.
    • (2012) Anal Bioanal Chem , vol.402 , Issue.10 , pp. 3039-3054
    • Galbán, J.1    Sanz-Vicente, I.2    Ortega, E.3    Del Barrio, M.4    De Marcos, S.5
  • 23
    • 0242501562 scopus 로고    scopus 로고
    • Genetic engineering of an allosterically based glucose indicator protein for continuous glucose monitoring by fluorescence resonance energy transfer
    • DOI 10.1021/ac034022q
    • Ye K, Schultz JS. Genetic engineering of an allosterically based glucose indicator protein for continuous glucose monitoring by fluorescence resonance energy transfer. Anal Chem. 2003;75(14):3451-9. (Pubitemid 36871235)
    • (2003) Analytical Chemistry , vol.75 , Issue.14 , pp. 3451-3459
    • Ye, K.1    Schultz, J.S.2
  • 24
    • 0038819942 scopus 로고    scopus 로고
    • In vivo imaging of the dynamics of glucose uptake in the cytosol of COS-7 cells by fluorescent nanosensors
    • DOI 10.1074/jbc.M301333200
    • Fehr M, Lalonde S, Lager I, Wolff MW, Frommer WB. In vivo imaging of the dynamics of glucose uptake in the cytosol of COS-7 cells by fluorescent nanosensors. J Biol Chem. 2003;278(21):19127-33. (Pubitemid 36799301)
    • (2003) Journal of Biological Chemistry , vol.278 , Issue.21 , pp. 19127-19133
    • Fehr, M.1    Lalonde, S.2    Lager, I.3    Wolff, M.W.4    Frommer, W.B.5
  • 25
    • 78649742270 scopus 로고    scopus 로고
    • A glucose sensor protein for continuous glucose monitoring
    • Veetil JV, Jin S, Ye K. A glucose sensor protein for continuous glucose monitoring. Biosens Bioelectron. 2010;26(4):1650-5.
    • (2010) Biosens Bioelectron , vol.26 , Issue.4 , pp. 1650-1655
    • Veetil, J.V.1    Jin, S.2    Ye, K.3
  • 26
    • 0032515425 scopus 로고    scopus 로고
    • Engineering biosensors by introducing fluorescent allosteric signal transducers: Construction of a novel glucose sensor
    • DOI 10.1021/ja972993f
    • Marvin JS, Hellinga HW. Engineering biosensors by introducing fluorescence allosteric signal transduction: construction of a novel glucose sensor. J Am Chem Soc. 1998;120:7-11. (Pubitemid 28046421)
    • (1998) Journal of the American Chemical Society , vol.120 , Issue.1 , pp. 7-11
    • Marvin, J.S.1    Hellinga, H.W.2
  • 28
    • 33748419826 scopus 로고    scopus 로고
    • A long-wavelength fluorescent glucose biosensor based on bioconjugates of galactose/glucose binding protein and Nile Red derivatives
    • DOI 10.1089/dia.2006.8.261
    • Thomas KJ, Sherman DB, Amiss TJ, Andaluz SA, Pitner JB. A long-wavelength fluorescent glucose biosensor based on bioconjugates of galactose/glucose binding protein and Nile Red derivatives. Diabetes Technol Ther. 2006;8(3):261-8. (Pubitemid 46100520)
    • (2006) Diabetes Technology and Therapeutics , vol.8 , Issue.3 , pp. 261-268
    • Thomas, K.J.1    Sherman, D.B.2    Amiss, T.J.3    Andaluz, S.A.4    Pitner, J.B.5
  • 29
    • 0035399396 scopus 로고    scopus 로고
    • A novel reagentless sensing system for measuring glucose based on the galactose/glucose-binding protein
    • DOI 10.1006/abio.2001.5131
    • Salins LL, Ware RA, Ensor CM, Daunert S. A novel reagentless sensing system for measuring glucose based on the galactose/glucose-binding protein. Anal Biochem. 2001;294(1):19-26. (Pubitemid 32612545)
    • (2001) Analytical Biochemistry , vol.294 , Issue.1 , pp. 19-26
    • Salins, L.L.E.1    Ware, R.A.2    Ensor, C.M.3    Daunert, S.4
  • 30
    • 1442348872 scopus 로고    scopus 로고
    • Dual-Labeled Glucose Binding Protein for Ratiometric Measurements of Glucose
    • DOI 10.1021/ac035063p
    • Ge X, Tolosa L, Rao G. Dual-labeled glucose binding protein for ratiometric measurements of glucose. Anal Chem. 2004;76(5):1403-10. (Pubitemid 38280488)
    • (2004) Analytical Chemistry , vol.76 , Issue.5 , pp. 1403-1410
    • Ge, X.1    Tolosa, L.2    Rao, G.3
  • 32
    • 77957079561 scopus 로고    scopus 로고
    • Microcapsules as optical biosensors
    • Ritter D, McShane M. Microcapsules as optical biosensors. J Mater Chem. 2010;20:8189-93.
    • (2010) J Mater Chem , vol.20 , pp. 8189-8193
    • Ritter, D.1    McShane, M.2
  • 33
    • 78649636755 scopus 로고    scopus 로고
    • Nanosensors and nanomaterials for monitoring glucose in diabetes
    • Cash KJ, Clark HA. Nanosensors and nanomaterials for monitoring glucose in diabetes. Trends Mol Med. 2010;16(12):584-93.
    • (2010) Trends Mol Med , vol.16 , Issue.12 , pp. 584-593
    • Cash, K.J.1    Clark, H.A.2
  • 34
    • 79954596633 scopus 로고    scopus 로고
    • Fluorescence detections and directions
    • Birch DJ. Fluorescence detections and directions. Meas Sci Technol. 2011;23:052002.
    • (2011) Meas Sci Technol , vol.23 , pp. 052002
    • Birch, D.J.1
  • 36
    • 0023476453 scopus 로고
    • Nile red as a polarity-sensitive fluorescent probe of hydrophobic protein surfaces
    • Sackett DL, Wolff J. Nile red as a polarity-sensitive fluorescent probe of hydrophobic protein surfaces. Anal Biochem. 1987;167(2):228-34.
    • (1987) Anal Biochem , vol.167 , Issue.2 , pp. 228-234
    • Sackett, D.L.1    Wolff, J.2
  • 37
    • 0025143896 scopus 로고
    • Hydrophobic surfaces of tubulin probed by time-resolved and steady-state fluorescence of Nile red
    • Sackett DL, Knutson JR, Wolff J. Hydrophobic surfaces of tubulin probed by time-resolved and steady-state fluorescence of Nile red. J Biol Chem. 1990;265(25):14899-906.
    • (1990) J Biol Chem , vol.265 , Issue.25 , pp. 14899-14906
    • Sackett, D.L.1    Knutson, J.R.2    Wolff, J.3
  • 38
    • 79951782758 scopus 로고    scopus 로고
    • Periplasmic binding proteins as optical modulators of single-walled carbon nanotube fluorescence: Amplifying a nanoscale actuator
    • Yoon H, Ahn JH, Barone PW, Yum K, Sharma R, Boghossian AA, Han JH, Strano MS. Periplasmic binding proteins as optical modulators of single-walled carbon nanotube fluorescence: amplifying a nanoscale actuator. Angew Chem Int Ed Engl. 2011;50(8):1828-31.
    • (2011) Angew Chem Int Ed Engl , vol.50 , Issue.8 , pp. 1828-1831
    • Yoon, H.1    Ahn, J.H.2    Barone, P.W.3    Yum, K.4    Sharma, R.5    Boghossian, A.A.6    Han, J.H.7    Strano, M.S.8
  • 39
    • 0037427330 scopus 로고    scopus 로고
    • Solvent-sensitive dyes to report protein conformational changes in living cells
    • DOI 10.1021/ja0290882
    • Toutchkine A, Kraynov V, Hahn K. Solvent-sensitive dyes to report protein conformational changes in living cells. J Am Chem Soc. 2003;125(14):4132-45. (Pubitemid 36512308)
    • (2003) Journal of the American Chemical Society , vol.125 , Issue.14 , pp. 4132-4145
    • Toutchkine, A.1    Kraynov, V.2    Hahn, K.3
  • 41
    • 77955473756 scopus 로고    scopus 로고
    • Continuous glucose sensor using novel genetically engineered binding polypeptides towards in vivo applications
    • Siegrist J, Kazarian T, Ensor C, Joel S, Madou M, Wang P, Daunert S. Continuous glucose sensor using novel genetically engineered binding polypeptides towards in vivo applications. Sens Actu B Chem. 2010;149(1):51-8.
    • (2010) Sens Actu B Chem , vol.149 , Issue.1 , pp. 51-58
    • Siegrist, J.1    Kazarian, T.2    Ensor, C.3    Joel, S.4    Madou, M.5    Wang, P.6    Daunert, S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.