Volumn 44, Issue 3, 2013, Pages 551-558

Effect of cannula position in the thoracic aorta with continuous left ventricular support: Four-dimensional flow-sensitive magnetic resonance imaging in an in vitro model

Author keywords

Aortic flow dynamics; LVAD; LVAD outflow graft; Three dimensional flow characteristics

Indexed keywords

ADULT; ANASTOMOSIS; ARTICLE; ASCENDING AORTA; CANNULA; DESCENDING AORTA; FEMALE; FLOW KINETICS; HEART OUTPUT; HUMAN; IN VITRO STUDY; LEFT VENTRICULAR ASSIST DEVICE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; THORACIC AORTA;

EID: 84882669337     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1093/ejcts/ezt095     Document Type: Article
Times cited : (21)

References (25)
  • 1
    • 73349087519 scopus 로고    scopus 로고
    • Rise of the machines-left ventricular assist devices as permanent therapy for advanced heart failure
    • Fang JC. Rise of the machines-left ventricular assist devices as permanent therapy for advanced heart failure. N Eng J Med. 2009;361:2282-5.
    • (2009) N Eng J Med. , vol.361 , pp. 2282-5
    • Fang, J.C.1
  • 3
    • 4544247955 scopus 로고    scopus 로고
    • Effects of left ventricular assist device support and outflow graft location upon aortic blood flow
    • Litwak KN, Koenig SC, Tsukui H, Kihara S, Wu Z, Pantalos GM. Effects of left ventricular assist device support and outflow graft location upon aortic blood flow. ASAIO J. 2004;50:432-7.
    • (2004) ASAIO J. , vol.50 , pp. 432-7
    • Litwak, K.N.1    Koenig, S.C.2    Tsukui, H.3    Kihara, S.4    Wu, Z.5    Pantalos, G.M.6
  • 5
    • 80052807726 scopus 로고    scopus 로고
    • Late aortic insufficiency related to poor prognosis during left ventricular assist device support
    • Toda K, Fujita T, Domae K, Shimahara Y, Kobayashi J, Nakatani T. Late aortic insufficiency related to poor prognosis during left ventricular assist device support. Ann Thorac Surg. 2011;92:929-34.
    • (2011) Ann Thorac Surg. , vol.92 , pp. 929-34
    • Toda, K.1    Fujita, T.2    Domae, K.3    Shimahara, Y.4    Kobayashi, J.5    Nakatani, T.6
  • 6
    • 79955681801 scopus 로고    scopus 로고
    • Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device
    • Hatano M, Kinugawa K, Shiga T, Kato N, Endo M, Hisagi M et al. Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device. Circ J. 2011;75:1147-55.
    • (2011) Circ J. , vol.75 , pp. 1147-55
    • Hatano, M.1    Kinugawa, K.2    Shiga, T.3    Kato, N.4    Endo, M.5    Hisagi, M.6
  • 7
    • 77957234680 scopus 로고    scopus 로고
    • Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices
    • Pak SW, Uriel N, Takayama H, Cappleman S, Song R, Colombo PC et al. Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices. J Heart Lung Transplant. 2010;29: 1172-6.
    • (2010) J Heart Lung Transplant. , vol.29 , pp. 1172-6
    • Pak, S.W.1    Uriel, N.2    Takayama, H.3    Cappleman, S.4    Song, R.5    Colombo, P.C.6
  • 9
    • 79955417667 scopus 로고    scopus 로고
    • Aortic root and valve thrombosis after implantation of a left ventricular assist device
    • Freed BH, Jeevanandam V, Jolly N. Aortic root and valve thrombosis after implantation of a left ventricular assist device. J Invasive Cardiol. 2011;23:63-5.
    • (2011) J Invasive Cardiol. , vol.23 , pp. 63-5
    • Freed, B.H.1    Jeevanandam, V.2    Jolly, N.3
  • 10
    • 78650963252 scopus 로고    scopus 로고
    • Thrombotic occlusion of the ascending aorta after Toyobo LVAD implantation with descending aortic perfusion in a post-Benhuge patient
    • Nawata K, Nishimura T, Kyo S, Hisagi M, Kinoshita O, Saito A et al. Thrombotic occlusion of the ascending aorta after Toyobo LVAD implantation with descending aortic perfusion in a post-Benhuge patient. J Artif Organs. 2010;13:228-31.
    • (2010) J Artif Organs. , vol.13 , pp. 228-31
    • Nawata, K.1    Nishimura, T.2    Kyo, S.3    Hisagi, M.4    Kinoshita, O.5    Saito, A.6
  • 11
    • 79955026597 scopus 로고    scopus 로고
    • Numerical simulation of the flow field within the aortic arch during cardiac assist
    • Filipovic N, Schima H. Numerical simulation of the flow field within the aortic arch during cardiac assist. Artif Organs. 2011;35:73-83.
    • (2011) Artif Organs. , vol.35 , pp. 73-83
    • Filipovic, N.1    Schima, H.2
  • 12
    • 24944570259 scopus 로고    scopus 로고
    • The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling
    • Kar B, Delgado RM 3rd, Frazier OH, Gregoric ID, Harting MT, Wadia Y et al. The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling. Tex Heart Inst J. 2005;32:294-8.
    • (2005) Tex Heart Inst J. , vol.32 , pp. 294-8
    • Kar, B.1    Delgado, R.M.2    Frazier, O.H.3    Gregoric, I.D.4    Harting, M.T.5    Wadia, Y.6
  • 14
    • 33744991763 scopus 로고    scopus 로고
    • Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta
    • May-Newman K, Hillen B, Dembitsky W. Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta. ASAIO J. 2006;52:132-9.
    • (2006) ASAIO J. , vol.52 , pp. 132-9
    • May-Newman, K.1    Hillen, B.2    Dembitsky, W.3
  • 15
    • 70450260492 scopus 로고    scopus 로고
    • Flow distribution during cardiopulmonary bypass in dependency on the outflow cannula positioning
    • Kaufmann TA, Hormes M, Laumen M, Timms DL, Schmit-Rode T, Moritz A et al. Flow distribution during cardiopulmonary bypass in dependency on the outflow cannula positioning. Artif Organs. 2009;33: 988-92.
    • (2009) Artif Organs. , vol.33 , pp. 988-92
    • Kaufmann, T.A.1    Hormes, M.2    Laumen, M.3    Timms, D.L.4    Schmitz-Rode, T.5    Moritz, A.6
  • 16
    • 77958567429 scopus 로고    scopus 로고
    • Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch
    • Laumen M, Kaufmann T, Timms D, Schlanstein P, Jansen S, Gregory S et al. Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch. Artif Organs. 2010;34:798-806.
    • (2010) Artif Organs. , vol.34 , pp. 798-806
    • Laumen, M.1    Kaufmann, T.2    Timms, D.3    Schlanstein, P.4    Jansen, S.5    Gregory, S.6
  • 17
    • 79953304124 scopus 로고    scopus 로고
    • Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
    • Markl M, Kilner PJ, Ebbers T. Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2011;13:7.
    • (2011) J Cardiovasc Magn Reson. , vol.13 , pp. 7
    • Markl, M.1    Kilner, P.J.2    Ebbers, T.3
  • 18
    • 84355162276 scopus 로고    scopus 로고
    • Closed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit
    • Lorenz R, Benk C, Bock J, Stalder AF, Korvink JG, Hennig J et al. Closed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit. Magn Reson Med. 2012;67:258-68.
    • (2012) Magn Reson Med. , vol.67 , pp. 258-68
    • Lorenz, R.1    Benk, C.2    Bock, J.3    Stalder, A.F.4    Korvink, J.G.5    Hennig, J.6
  • 19
    • 80054994254 scopus 로고    scopus 로고
    • Three-dimensional flow characteristics in ventricular assist devices: impact of valve design and operating conditions
    • Benk C, Lorenz R, Beyersdorf F, Bock J, Klemm R, Korvink JG et al. Three-dimensional flow characteristics in ventricular assist devices: impact of valve design and operating conditions. J Thorac Cardiovasc Surg. 2011;142:1019-26.
    • (2011) J Thorac Cardiovasc Surg. , vol.142 , pp. 1019-26
    • Benk, C.1    Lorenz, R.2    Beyersdorf, F.3    Bock, J.4    Klemm, R.5    Korvink, J.G.6
  • 20
    • 77957564604 scopus 로고    scopus 로고
    • Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics
    • Isoda H, Ohkura Y, Kosugi T, Hirano M, Alley MT, Bammer R et al. Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics. Neuroradiology. 2010;52:913-20.
    • (2010) Neuroradiology. , vol.52 , pp. 913-20
    • Isoda, H.1    Ohkura, Y.2    Kosugi, T.3    Hirano, M.4    Alley, M.T.5    Bammer, R.6
  • 21
    • 40449115994 scopus 로고    scopus 로고
    • 3D MR flow analysis in realistic rapid-prototyping model systems of the thoracic aorta: comparison with in vivo data and computational fluid dynamics in identical vessel geometries
    • Canstein C, Cachot P, Faust A, Stalder AF, Bock J, Frydrychowicz A et al. 3D MR flow analysis in realistic rapid-prototyping model systems of the thoracic aorta: comparison with in vivo data and computational fluid dynamics in identical vessel geometries. Magn Reson Med. 2008;59: 535-46.
    • (2008) Magn Reson Med. , vol.59 , pp. 535-46
    • Canstein, C.1    Cachot, P.2    Faust, A.3    Stalder, A.F.4    Bock, J.5    Frydrychowicz, A.6
  • 22
    • 77249132505 scopus 로고    scopus 로고
    • Investigation of pulsatile flowfield in healthy thoracic aorta models
    • Wen CY, Yang AS, Tseng LY, Chai JW. Investigation of pulsatile flowfield in healthy thoracic aorta models. Ann Biomed Eng. 2010;38:391-402.
    • (2010) Ann Biomed Eng. , vol.38 , pp. 391-402
    • Wen, C.Y.1    Yang, A.S.2    Tseng, L.Y.3    Chai, J.W.4
  • 24
    • 55749085612 scopus 로고    scopus 로고
    • Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters
    • Stalder AF, Russe MF, Frydrychowicz A, Bock J, Hennig J, Markl M. Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Magn Reson Med. 2008;60: 1218-31.
    • (2008) Magn Reson Med. , vol.60 , pp. 1218-31
    • Stalder, A.F.1    Russe, M.F.2    Frydrychowicz, A.3    Bock, J.4    Hennig, J.5    Markl, M.6
  • 25
    • 0842286457 scopus 로고    scopus 로고
    • In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices
    • DiGiorgi PL, Smith DL, Naka Y, Oz MC. In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices. J Heart Lung Transplant. 2004;23:186-92.
    • (2004) J Heart Lung Transplant. , vol.23 , pp. 186-92
    • DiGiorgi, P.L.1    Smith, D.L.2    Naka, Y.3    Oz, M.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.