-
1
-
-
73349087519
-
Rise of the machines-left ventricular assist devices as permanent therapy for advanced heart failure
-
Fang JC. Rise of the machines-left ventricular assist devices as permanent therapy for advanced heart failure. N Eng J Med. 2009;361:2282-5.
-
(2009)
N Eng J Med.
, vol.361
, pp. 2282-5
-
-
Fang, J.C.1
-
2
-
-
84871673891
-
Low stroke rate and few thrombo-embolic events after HeartMate II implantation under mild anticoagulation
-
Menon AK, Götzenich A, Sassmannshausen H, Haushofer M, Autschbach R, Spillner JW. Low stroke rate and few thrombo-embolic events after HeartMate II implantation under mild anticoagulation. Eur J Cardiothorac Surg. 2012;42:319-23.
-
(2012)
Eur J Cardiothorac Surg.
, vol.42
, pp. 319-23
-
-
Menon, A.K.1
Götzenich, A.2
Sassmannshausen, H.3
Haushofer, M.4
Autschbach, R.5
Spillner, J.W.6
-
3
-
-
4544247955
-
Effects of left ventricular assist device support and outflow graft location upon aortic blood flow
-
Litwak KN, Koenig SC, Tsukui H, Kihara S, Wu Z, Pantalos GM. Effects of left ventricular assist device support and outflow graft location upon aortic blood flow. ASAIO J. 2004;50:432-7.
-
(2004)
ASAIO J.
, vol.50
, pp. 432-7
-
-
Litwak, K.N.1
Koenig, S.C.2
Tsukui, H.3
Kihara, S.4
Wu, Z.5
Pantalos, G.M.6
-
4
-
-
78650096247
-
The development of aortic insufficiency in left ventricular assist devicesupported patients
-
Cowger J, Pagani FD, Haft JW, Romano MA, Aaronson KD, Kolias TJ. The development of aortic insufficiency in left ventricular assist devicesupported patients. Circ Heart Fail. 2010;3:668-74.
-
(2010)
Circ Heart Fail.
, vol.3
, pp. 668-74
-
-
Cowger, J.1
Pagani, F.D.2
Haft, J.W.3
Romano, M.A.4
Aaronson, K.D.5
Kolias, T.J.6
-
5
-
-
80052807726
-
Late aortic insufficiency related to poor prognosis during left ventricular assist device support
-
Toda K, Fujita T, Domae K, Shimahara Y, Kobayashi J, Nakatani T. Late aortic insufficiency related to poor prognosis during left ventricular assist device support. Ann Thorac Surg. 2011;92:929-34.
-
(2011)
Ann Thorac Surg.
, vol.92
, pp. 929-34
-
-
Toda, K.1
Fujita, T.2
Domae, K.3
Shimahara, Y.4
Kobayashi, J.5
Nakatani, T.6
-
6
-
-
79955681801
-
Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device
-
Hatano M, Kinugawa K, Shiga T, Kato N, Endo M, Hisagi M et al. Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device. Circ J. 2011;75:1147-55.
-
(2011)
Circ J.
, vol.75
, pp. 1147-55
-
-
Hatano, M.1
Kinugawa, K.2
Shiga, T.3
Kato, N.4
Endo, M.5
Hisagi, M.6
-
7
-
-
77957234680
-
Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices
-
Pak SW, Uriel N, Takayama H, Cappleman S, Song R, Colombo PC et al. Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices. J Heart Lung Transplant. 2010;29: 1172-6.
-
(2010)
J Heart Lung Transplant.
, vol.29
, pp. 1172-6
-
-
Pak, S.W.1
Uriel, N.2
Takayama, H.3
Cappleman, S.4
Song, R.5
Colombo, P.C.6
-
8
-
-
77957755990
-
Aortic valve pathophysiology during left ventricular assist device support
-
John R, Mantz K, Eckman P, Rose A, May-Newman K. Aortic valve pathophysiology during left ventricular assist device support. J Heart Lung Transplant. 2010;29:1321-9.
-
(2010)
J Heart Lung Transplant.
, vol.29
, pp. 1321-9
-
-
John, R.1
Mantz, K.2
Eckman, P.3
Rose, A.4
May-Newman, K.5
-
9
-
-
79955417667
-
Aortic root and valve thrombosis after implantation of a left ventricular assist device
-
Freed BH, Jeevanandam V, Jolly N. Aortic root and valve thrombosis after implantation of a left ventricular assist device. J Invasive Cardiol. 2011;23:63-5.
-
(2011)
J Invasive Cardiol.
, vol.23
, pp. 63-5
-
-
Freed, B.H.1
Jeevanandam, V.2
Jolly, N.3
-
10
-
-
78650963252
-
Thrombotic occlusion of the ascending aorta after Toyobo LVAD implantation with descending aortic perfusion in a post-Benhuge patient
-
Nawata K, Nishimura T, Kyo S, Hisagi M, Kinoshita O, Saito A et al. Thrombotic occlusion of the ascending aorta after Toyobo LVAD implantation with descending aortic perfusion in a post-Benhuge patient. J Artif Organs. 2010;13:228-31.
-
(2010)
J Artif Organs.
, vol.13
, pp. 228-31
-
-
Nawata, K.1
Nishimura, T.2
Kyo, S.3
Hisagi, M.4
Kinoshita, O.5
Saito, A.6
-
11
-
-
79955026597
-
Numerical simulation of the flow field within the aortic arch during cardiac assist
-
Filipovic N, Schima H. Numerical simulation of the flow field within the aortic arch during cardiac assist. Artif Organs. 2011;35:73-83.
-
(2011)
Artif Organs.
, vol.35
, pp. 73-83
-
-
Filipovic, N.1
Schima, H.2
-
12
-
-
24944570259
-
The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling
-
Kar B, Delgado RM 3rd, Frazier OH, Gregoric ID, Harting MT, Wadia Y et al. The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling. Tex Heart Inst J. 2005;32:294-8.
-
(2005)
Tex Heart Inst J.
, vol.32
, pp. 294-8
-
-
Kar, B.1
Delgado, R.M.2
Frazier, O.H.3
Gregoric, I.D.4
Harting, M.T.5
Wadia, Y.6
-
13
-
-
77957751612
-
Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop
-
Tuzun E, Rutten M, Dat M, van de Vosse F, Kadipasaoglu C, de Mol B. Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop. J Surg Res. 2011;171:443-7.
-
(2011)
J Surg Res.
, vol.171
, pp. 443-7
-
-
Tuzun, E.1
Rutten, M.2
Dat, M.3
van de Vosse, F.4
Kadipasaoglu, C.5
de Mol, B.6
-
14
-
-
33744991763
-
Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta
-
May-Newman K, Hillen B, Dembitsky W. Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta. ASAIO J. 2006;52:132-9.
-
(2006)
ASAIO J.
, vol.52
, pp. 132-9
-
-
May-Newman, K.1
Hillen, B.2
Dembitsky, W.3
-
15
-
-
70450260492
-
Flow distribution during cardiopulmonary bypass in dependency on the outflow cannula positioning
-
Kaufmann TA, Hormes M, Laumen M, Timms DL, Schmit-Rode T, Moritz A et al. Flow distribution during cardiopulmonary bypass in dependency on the outflow cannula positioning. Artif Organs. 2009;33: 988-92.
-
(2009)
Artif Organs.
, vol.33
, pp. 988-92
-
-
Kaufmann, T.A.1
Hormes, M.2
Laumen, M.3
Timms, D.L.4
Schmitz-Rode, T.5
Moritz, A.6
-
16
-
-
77958567429
-
Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch
-
Laumen M, Kaufmann T, Timms D, Schlanstein P, Jansen S, Gregory S et al. Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch. Artif Organs. 2010;34:798-806.
-
(2010)
Artif Organs.
, vol.34
, pp. 798-806
-
-
Laumen, M.1
Kaufmann, T.2
Timms, D.3
Schlanstein, P.4
Jansen, S.5
Gregory, S.6
-
17
-
-
79953304124
-
Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
-
Markl M, Kilner PJ, Ebbers T. Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2011;13:7.
-
(2011)
J Cardiovasc Magn Reson.
, vol.13
, pp. 7
-
-
Markl, M.1
Kilner, P.J.2
Ebbers, T.3
-
18
-
-
84355162276
-
Closed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit
-
Lorenz R, Benk C, Bock J, Stalder AF, Korvink JG, Hennig J et al. Closed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit. Magn Reson Med. 2012;67:258-68.
-
(2012)
Magn Reson Med.
, vol.67
, pp. 258-68
-
-
Lorenz, R.1
Benk, C.2
Bock, J.3
Stalder, A.F.4
Korvink, J.G.5
Hennig, J.6
-
19
-
-
80054994254
-
Three-dimensional flow characteristics in ventricular assist devices: impact of valve design and operating conditions
-
Benk C, Lorenz R, Beyersdorf F, Bock J, Klemm R, Korvink JG et al. Three-dimensional flow characteristics in ventricular assist devices: impact of valve design and operating conditions. J Thorac Cardiovasc Surg. 2011;142:1019-26.
-
(2011)
J Thorac Cardiovasc Surg.
, vol.142
, pp. 1019-26
-
-
Benk, C.1
Lorenz, R.2
Beyersdorf, F.3
Bock, J.4
Klemm, R.5
Korvink, J.G.6
-
20
-
-
77957564604
-
Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics
-
Isoda H, Ohkura Y, Kosugi T, Hirano M, Alley MT, Bammer R et al. Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics. Neuroradiology. 2010;52:913-20.
-
(2010)
Neuroradiology.
, vol.52
, pp. 913-20
-
-
Isoda, H.1
Ohkura, Y.2
Kosugi, T.3
Hirano, M.4
Alley, M.T.5
Bammer, R.6
-
21
-
-
40449115994
-
3D MR flow analysis in realistic rapid-prototyping model systems of the thoracic aorta: comparison with in vivo data and computational fluid dynamics in identical vessel geometries
-
Canstein C, Cachot P, Faust A, Stalder AF, Bock J, Frydrychowicz A et al. 3D MR flow analysis in realistic rapid-prototyping model systems of the thoracic aorta: comparison with in vivo data and computational fluid dynamics in identical vessel geometries. Magn Reson Med. 2008;59: 535-46.
-
(2008)
Magn Reson Med.
, vol.59
, pp. 535-46
-
-
Canstein, C.1
Cachot, P.2
Faust, A.3
Stalder, A.F.4
Bock, J.5
Frydrychowicz, A.6
-
22
-
-
77249132505
-
Investigation of pulsatile flowfield in healthy thoracic aorta models
-
Wen CY, Yang AS, Tseng LY, Chai JW. Investigation of pulsatile flowfield in healthy thoracic aorta models. Ann Biomed Eng. 2010;38:391-402.
-
(2010)
Ann Biomed Eng.
, vol.38
, pp. 391-402
-
-
Wen, C.Y.1
Yang, A.S.2
Tseng, L.Y.3
Chai, J.W.4
-
23
-
-
79954910199
-
Optimized Pre-processing of Time-resolved 2D and 3D Phase Contrast MRI Data
-
Berlin, Germany
-
Bock J, Kreher BW, Hennig J, Markl M. Optimized Pre-processing of Time-resolved 2D and 3D Phase Contrast MRI Data. In: Proceedings of 15th Scientific Meeting International Society for Magnetic Resonance in Medicine, p. 3138. Berlin, Germany, 2007.
-
(2007)
In: Proceedings of 15th Scientific Meeting International Society for Magnetic Resonance in Medicine
, pp. 3138
-
-
Bock, J.1
Kreher, B.W.2
Hennig, J.3
Markl, M.4
-
24
-
-
55749085612
-
Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters
-
Stalder AF, Russe MF, Frydrychowicz A, Bock J, Hennig J, Markl M. Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Magn Reson Med. 2008;60: 1218-31.
-
(2008)
Magn Reson Med.
, vol.60
, pp. 1218-31
-
-
Stalder, A.F.1
Russe, M.F.2
Frydrychowicz, A.3
Bock, J.4
Hennig, J.5
Markl, M.6
-
25
-
-
0842286457
-
In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices
-
DiGiorgi PL, Smith DL, Naka Y, Oz MC. In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices. J Heart Lung Transplant. 2004;23:186-92.
-
(2004)
J Heart Lung Transplant.
, vol.23
, pp. 186-92
-
-
DiGiorgi, P.L.1
Smith, D.L.2
Naka, Y.3
Oz, M.C.4
|