메뉴 건너뛰기




Volumn 75, Issue 5, 2011, Pages 1147-1155

Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device

Author keywords

Aortic insufficiency; Heart failure; Left ventricular assist device; Transplantation

Indexed keywords

BRAIN NATRIURETIC PEPTIDE;

EID: 79955681801     PISSN: 13469843     EISSN: 13474820     Source Type: Journal    
DOI: 10.1253/circj.CJ-10-1106     Document Type: Article
Times cited : (94)

References (28)
  • 1
    • 77956010738 scopus 로고    scopus 로고
    • Improved long-term performance of pulsatile extracorporeal left ventricular assist device
    • Sasaoka T, Kato TS, Komamura K, Takahashi A, Nakajima I, Oda N, et al. Improved long-term performance of pulsatile extracorporeal left ventricular assist device. J Cardiol 2010; 56: 220-228.
    • (2010) J Cardiol , vol.56 , pp. 220-228
    • Sasaoka, T.1    Kato, T.S.2    Komamura, K.3    Takahashi, A.4    Nakajima, I.5    Oda, N.6
  • 2
    • 78651262544 scopus 로고    scopus 로고
    • Age and preoperative total bilirubin level can stratify prognosis after toyobo left ventricular assist device implantation
    • Shiga T, Kinugawa K, Hatano M, Yao A, Nishimura T, Endo M, et al. Age and preoperative total bilirubin level can stratify prognosis after toyobo left ventricular assist device implantation. Circ J 2011; 75: 121-128.
    • (2011) Circ J , vol.75 , pp. 121-128
    • Shiga, T.1    Kinugawa, K.2    Hatano, M.3    Yao, A.4    Nishimura, T.5    Endo, M.6
  • 4
    • 33845415719 scopus 로고    scopus 로고
    • Management of aortic insufficiency with continuous flow left ventricular assist devices: Bioprosthetic valve replacement
    • Feldman CM, Silver MA, Sobieski MA, Slaughter MS. Management of aortic insufficiency with continuous flow left ventricular assist devices: Bioprosthetic valve replacement. J Heart Lung Transplant 2006; 25: 1410-1412.
    • (2006) J Heart Lung Transplant , vol.25 , pp. 1410-1412
    • Feldman, C.M.1    Silver, M.A.2    Sobieski, M.A.3    Slaughter, M.S.4
  • 6
    • 0742288435 scopus 로고    scopus 로고
    • Management of aortic insufficiency in patients with left ventricular assist devices: A simple coaptation stitch method (Park's stitch)
    • Park SJ, Liao KK, Segurola R, Madhu KP, Miller LW. Management of aortic insufficiency in patients with left ventricular assist devices: A simple coaptation stitch method (Park's stitch). J Thorac Cardiovasc Surg 2004; 127: 264-266.
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 264-266
    • Park, S.J.1    Liao, K.K.2    Segurola, R.3    Madhu, K.P.4    Miller, L.W.5
  • 7
    • 0035437458 scopus 로고    scopus 로고
    • Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: Signs, symptoms, and concerns
    • Samuels LE, Thomas MP, Holmes EC, Narula J, Fitzpatrick J, Wood D, et al. Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: Signs, symptoms, and concerns. J Thorac Cardiovasc Surg 2001; 122: 380-381.
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 380-381
    • Samuels, L.E.1    Thomas, M.P.2    Holmes, E.C.3    Narula, J.4    Fitzpatrick, J.5    Wood, D.6
  • 8
    • 77957234680 scopus 로고    scopus 로고
    • Prevalence of de novo aortic insufficiency during longterm support with left ventricular assist devices
    • Pak SW, Uriel N, Takayama H, Cappleman S, Song R, Colombo PC, et al. Prevalence of de novo aortic insufficiency during longterm support with left ventricular assist devices. J Heart Lung Transplant 2010; 29: 1172-1176.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 1172-1176
    • Pak, S.W.1    Uriel, N.2    Takayama, H.3    Cappleman, S.4    Song, R.5    Colombo, P.C.6
  • 9
    • 33645058692 scopus 로고    scopus 로고
    • Is native aortic valve commissural fusion in patients with long-term left ventricular assist devices associated with clinically important aortic insufficiency?
    • Letsou GV, Connelly JH, Delgado RM 3rd, Myers TJ, Gregoric ID, Smart FW, et al. Is native aortic valve commissural fusion in patients with long-term left ventricular assist devices associated with clinically important aortic insufficiency? J Heart Lung Transplant 2006; 25: 395-399.
    • (2006) J Heart Lung Transplant , vol.25 , pp. 395-399
    • Letsou, G.V.1    Connelly, J.H.2    Delgado, R.M.3    Myers, T.J.4    Gregoric, I.D.5    Smart, F.W.6
  • 10
    • 22544479705 scopus 로고    scopus 로고
    • Images in cardiovascular medicine: High left ventricular assist device flows resulting from combined native aortic valve and outflow valve regurgitation
    • Amir O, Kar B, Delgado RM 3rd, Younis AG, Gregoric ID, Smart FW, et al. Images in cardiovascular medicine: High left ventricular assist device flows resulting from combined native aortic valve and outflow valve regurgitation. Circulation 2005; 111: e34.
    • (2005) Circulation , vol.111
    • Amir, O.1    Kar, B.2    Delgado, R.M.3    Younis, A.G.4    Gregoric, I.D.5    Smart, F.W.6
  • 12
    • 57049163522 scopus 로고    scopus 로고
    • Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device
    • Mudd JO, Cuda JD, Halushka M, Soderlund KA, Conte JV, Russell SD. Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device. J Heart Lung Transplant 2008; 27: 1269-1274.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1269-1274
    • Mudd, J.O.1    Cuda, J.D.2    Halushka, M.3    Soderlund, K.A.4    Conte, J.V.5    Russell, S.D.6
  • 16
    • 33750566081 scopus 로고    scopus 로고
    • The Duraheart VAD, a magnetically levitated centrifugal pump: The University of Vienna bridge-to-transplant experience
    • Nishinaka T, Schima H, Roethy W, Rajek A, Nojiri C, Wolner E, et al. The Duraheart VAD, a magnetically levitated centrifugal pump: The University of Vienna bridge-to-transplant experience. Circ J 2006; 70: 1421-1425.
    • (2006) Circ J , vol.70 , pp. 1421-1425
    • Nishinaka, T.1    Schima, H.2    Roethy, W.3    Rajek, A.4    Nojiri, C.5    Wolner, E.6
  • 17
    • 85047689580 scopus 로고    scopus 로고
    • Use of the jarvik 2000 left ventricular assist system as a bridge to heart transplantation or as destination therapy for patients with chronic heart failure
    • Frazier OH, Myers TJ, Westaby S, Gregoric ID. Use of the jarvik 2000 left ventricular assist system as a bridge to heart transplantation or as destination therapy for patients with chronic heart failure. Ann Surg 2003; 237: 631-636.
    • (2003) Ann Surg , vol.237 , pp. 631-636
    • Frazier, O.H.1    Myers, T.J.2    Westaby, S.3    Gregoric, I.D.4
  • 19
    • 0036657899 scopus 로고    scopus 로고
    • Severe aortic valve fusion after nearly three years of support with the novacor left ventricular assist system
    • Nishimura M, Ohtake S, Sawa Y, Fukushima N, Matsumiya G, Matsuda H. Severe aortic valve fusion after nearly three years of support with the novacor left ventricular assist system. J Thorac Cardiovasc Surg 2002; 124: 179-180.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 179-180
    • Nishimura, M.1    Ohtake, S.2    Sawa, Y.3    Fukushima, N.4    Matsumiya, G.5    Matsuda, H.6
  • 20
    • 0036840916 scopus 로고    scopus 로고
    • Left ventricular outflow tract obstruction associated with chronic ventricular assist device support
    • Baradarian S, Dembitsky WP, Jaski B, Abolhoda A, Adamson R, Chillcot S, et al. Left ventricular outflow tract obstruction associated with chronic ventricular assist device support. ASAIO J 2002; 48: 665-667.
    • (2002) ASAIO J , vol.48 , pp. 665-667
    • Baradarian, S.1    Dembitsky, W.P.2    Jaski, B.3    Abolhoda, A.4    Adamson, R.5    Chillcot, S.6
  • 21
    • 33744991763 scopus 로고    scopus 로고
    • Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta
    • May-Newman K, Hillen B, Dembitsky W. Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta. ASAIO J 2006; 52: 132-139.
    • (2006) ASAIO J , vol.52 , pp. 132-139
    • May-Newman, K.1    Hillen, B.2    Dembitsky, W.3
  • 22
    • 46249083627 scopus 로고    scopus 로고
    • Preload sensitivity of the Jarvik 2000 and Heartmate II left ventricular assist devices
    • Khalil HA, Cohn WE, Metcalfe RW, Frazier OH. Preload sensitivity of the Jarvik 2000 and Heartmate II left ventricular assist devices. ASAIO J 2008; 54: 245-248.
    • (2008) ASAIO J , vol.54 , pp. 245-248
    • Khalil, H.A.1    Cohn, W.E.2    Metcalfe, R.W.3    Frazier, O.H.4
  • 23
    • 77956623472 scopus 로고    scopus 로고
    • Hemodynamic stress echocardiography in patients supported with a continuous-flow left ventricular assist device
    • Andersen M, Gustafsson F, Madsen PL, Brassard P, Jensen AS, Secher N, et al. Hemodynamic stress echocardiography in patients supported with a continuous-flow left ventricular assist device. JACC Cardiovasc Imaging 2010; 3: 854-859.
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 854-859
    • Andersen, M.1    Gustafsson, F.2    Madsen, P.L.3    Brassard, P.4    Jensen, A.S.5    Secher, N.6
  • 24
    • 14444268039 scopus 로고    scopus 로고
    • Prolonged nonpulsatile left heart bypass with reduced systemic pulse pressure causes morphological changes in the aortic wall
    • Nishimura T, Tatsumi E, Takaichi S, Taenaka Y, Wakisaka Y, Nakatani T, et al. Prolonged nonpulsatile left heart bypass with reduced systemic pulse pressure causes morphological changes in the aortic wall. Artif Organs 1998; 22: 405-410.
    • (1998) Artif Organs , vol.22 , pp. 405-410
    • Nishimura, T.1    Tatsumi, E.2    Takaichi, S.3    Taenaka, Y.4    Wakisaka, Y.5    Nakatani, T.6
  • 26
    • 40749128111 scopus 로고    scopus 로고
    • Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading
    • Garcia S, Kandar F, Boyle A, Colvin-Adams M, Lliao K, Joyce L, et al. Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading. J Heart Lung Transplant 2008; 27: 261-267.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 261-267
    • Garcia, S.1    Kandar, F.2    Boyle, A.3    Colvin-Adams, M.4    Lliao, K.5    Joyce, L.6
  • 27
    • 34748926436 scopus 로고    scopus 로고
    • Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices
    • Haft J, Armstrong W, Dyke DB, Aaronson KD, Koelling TM, Farrar DJ, et al. Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation 2007; 116: I8-I15.
    • (2007) Circulation , vol.116
    • Haft, J.1    Armstrong, W.2    Dyke, D.B.3    Aaronson, K.D.4    Koelling, T.M.5    Farrar, D.J.6
  • 28
    • 77957755990 scopus 로고    scopus 로고
    • Aortic valve pathophysiology during left ventricular assist device support
    • John R, Mantz K, Eckman P, Rose A, May-Newman K. Aortic valve pathophysiology during left ventricular assist device support. J Heart Lung Transplant 2010; 29: 1321-1329.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 1321-1329
    • John, R.1    Mantz, K.2    Eckman, P.3    Rose, A.4    May-Newman, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.