메뉴 건너뛰기




Volumn 95 B, Issue 8, 2013, Pages 1101-1105

A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures: The dorsal horizon view

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; BONE SCREW; CADAVER; CONTROLLED STUDY; ELBOW RADIOGRAPHY; FEMALE; HUMAN; HUMAN TISSUE; MALE; PRIORITY JOURNAL; RADIUS FRACTURE; VOLAR PLATE FIXATION; WRIST RADIOGRAPHY;

EID: 84882631008     PISSN: None     EISSN: 20494408     Source Type: Journal    
DOI: 10.1302/0301-620X.95B8.31301     Document Type: Article
Times cited : (40)

References (12)
  • 1
    • 22544439956 scopus 로고    scopus 로고
    • Palmar plating system for colles' fractures: A preliminary report
    • Kamano M, Koshimune M, Toyama M, Kazuki K. Palmar plating system for Colles' fractures: a preliminary report. J Hand Surg Am 2005;30:750-755.
    • (2005) J Hand Surg Am , vol.30 , pp. 750-755
    • Kamano, M.1    Koshimune, M.2    Toyama, M.3    Kazuki, K.4
  • 2
    • 33644637372 scopus 로고    scopus 로고
    • Treatment of distal radius fractures with a low-profile dorsal plating system: An outcomes assessment
    • Simic PM, Robison J, Gardner MJ, et al. Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment. J Hand Surg Am 2006;31:382-386.
    • (2006) J Hand Surg Am , vol.31 , pp. 382-386
    • Simic, P.M.1    Robison, J.2    Gardner, M.J.3
  • 3
    • 0032460038 scopus 로고    scopus 로고
    • Complications of the ao/asif titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report
    • Kambouroglou GK, Axelrod TS. Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg Am 1998;23:737-741.
    • (1998) J Hand Surg Am , vol.23 , pp. 737-741
    • Kambouroglou, G.K.1    Axelrod, T.S.2
  • 4
    • 31544472058 scopus 로고    scopus 로고
    • Volar versus dorsal plating in the management of intra-Articular distal radius fractures
    • Ruch DS, Papadonikolakis A. Volar versus dorsal plating in the management of intra-Articular distal radius fractures. J Hand Surg Am 2006;31:9-16.
    • (2006) J Hand Surg Am , vol.31 , pp. 9-16
    • Ruch, D.S.1    Papadonikolakis, A.2
  • 5
    • 34248229716 scopus 로고    scopus 로고
    • Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    • Arora R, Lutz M, Hennerbichler A, et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007;21:316-322.
    • (2007) J Orthop Trauma , vol.21 , pp. 316-322
    • Arora, R.1    Lutz, M.2    Hennerbichler, A.3
  • 6
    • 0034837212 scopus 로고    scopus 로고
    • Assessment of complications of distal radius fractures and development of a complication checklist
    • McKay SD, MacDermid JC, Roth JH, Richards RS. Assessment of complications of distal radius fractures and development of a complication checklist. J Hand Surg Am 2001;26:916-922.
    • (2001) J Hand Surg Am , vol.26 , pp. 916-922
    • McKay, S.D.1    MacDermid, J.C.2    Roth, J.H.3    Richards, R.S.4
  • 7
    • 33644649770 scopus 로고    scopus 로고
    • Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius
    • Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 2006;31:359-365.
    • (2006) J Hand Surg Am , vol.31 , pp. 359-365
    • Rozental, T.D.1    Blazar, P.E.2
  • 8
    • 34547581677 scopus 로고    scopus 로고
    • Radiographic evaluation of dorsal screw penetration after volar fixed-Angle plating of the distal radius: A cadaveric study
    • Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN. Radiographic evaluation of dorsal screw penetration after volar fixed-Angle plating of the distal radius: a cadaveric study. Hand (N Y) 2007;2:144-150.
    • (2007) Hand (N Y , vol.2 , pp. 144-150
    • Maschke, S.D.1    Evans, P.J.2    Schub, D.3    Drake, R.4    Lawton, J.N.5
  • 9
    • 80053562284 scopus 로고    scopus 로고
    • The dorsal horizon view: Detecting screw protrusion at the distal radius
    • Joseph SJ, Harvey JN. The dorsal horizon view: detecting screw protrusion at the distal radius. J Hand Surg Am 2011;36:1691-1693.
    • (2011) J Hand Surg Am , vol.36 , pp. 1691-1693
    • Joseph, S.J.1    Harvey, J.N.2
  • 10
    • 79955874759 scopus 로고    scopus 로고
    • Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-Angle plating
    • Ozer K, Toker S. Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-Angle plating. Hand (N Y) 2011;6:190-193.
    • (2011) Hand (N Y , vol.6 , pp. 190-193
    • Ozer, K.1    Toker, S.2
  • 11
    • 53749085374 scopus 로고    scopus 로고
    • Calcified plaque: Measurement of area at thin-section flat-panel ct and 64-section multidetector ct and comparison with histopathologic findings
    • Sarwar A, Rieber J, Mooyaart EA, et al. Calcified plaque: measurement of area at thin-section flat-panel CT and 64-section multidetector CT and comparison with histopathologic findings. Radiology 2008;249:301-306.
    • (2008) Radiology , vol.249 , pp. 301-306
    • Sarwar, A.1    Rieber, J.2    Mooyaart, E.A.3
  • 12
    • 84876228802 scopus 로고    scopus 로고
    • Ct imaging of coronary stents: Past, present, and future
    • Mahnken AH. CT imaging of coronary stents: past, present, and future. ISRN Cardiol 2012;2012:139823.
    • (2012) ISRN Cardiol , vol.2012 , pp. 139823
    • Mahnken, A.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.