1
-
-
33845521334
-
Feasibility of automating insulin delivery for the treatment of type 1 diabetes
-
Steil GM, Rebrin K, Darwin C, Hariri F, Saad MF: Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes 2005;55:3344-3350
-
(2005)
Diabetes
, vol.55
, pp. 3344-3350
-
-
Steil, G.M.1
Rebrin, K.2
Darwin, C.3
Hariri, F.4
Saad, M.F.5
-
2
-
-
84868087308
-
The use of an automated, portable glucose control system for overnight glucose control in adolescents and young adults with type 1 diabetes
-
O'Grady MJ, Retterath AJ, Keenan DB, Kurtz N, Cantwell M, Spital G, Kremliovsky MN, Roy A, Davis EA, Jones TW, Ly TT: The use of an automated, portable glucose control system for overnight glucose control in adolescents and young adults with type 1 diabetes. Diabetes Care 2012;35:2182-2187
-
(2012)
Diabetes Care
, vol.35
, pp. 2182-2187
-
-
O'Grady, M.J.1
Retterath, A.J.2
Keenan, D.B.3
Kurtz, N.4
Cantwell, M.5
Spital, G.6
Kremliovsky, M.N.7
Roy, A.8
Davis, E.A.9
Jones, T.W.10
Ly, T.T.11
-
3
-
-
80655141686
-
Closed-loop insulin delivery for treatment of type 1 diabetes
-
Elleri D, Bunger DB, Horvorka R: Closed-loop insulin delivery for treatment of type 1 diabetes. BMC Med 2011;9:120
-
(2011)
BMC Med
, vol.9
, pp. 120
-
-
Elleri, D.1
Bunger, D.B.2
Horvorka, R.3
-
4
-
-
79953186640
-
Automated overnight closed-loop glucose control in young children with type 1 diabetes
-
Elleri D, Allen JM, NodaleM, WilinskaME,Mangat JS, Larsen AM, Acerini CL, Dunget DB, Hovorka R: Automated overnight closed-loop glucose control in young children with type 1 diabetes. Diabetes Technol Ther 2011;13:419-424
-
(2011)
Diabetes Technol Ther
, vol.13
, pp. 419-424
-
-
Elleri, D.1
Allen, J.M.2
Nodale, M.3
Wilinska, M.E.4
Mangat, J.S.5
Larsen, A.M.6
Acerini, C.L.7
Dunget, D.B.8
Hovorka, R.9
-
5
-
-
79954457764
-
Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: Crossover randomised controlled studies
-
Hovorka R, Kumareswaran K, Harris J, Allen JM, Elleri D, Xing D, Kollman C, Nodale M, Murphy HR, Dunger DB, Amiel SA, Heller SR, Wilinska ME, Evans ML: Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: Crossover randomised controlled studies. BMJ 2011;342:d1855
-
(2011)
BMJ
-
-
Hovorka, R.1
Kumareswaran, K.2
Harris, J.3
Allen, J.M.4
Elleri, D.5
Xing, D.6
Kollman, C.7
Nodale, M.8
Murphy, H.R.9
Dunger, D.B.10
Amiel, S.A.11
Heller, S.R.12
Wilinska, M.E.13
Evans, M.L.14
-
6
-
-
79953021776
-
Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: Summary of the results
-
Kovatchev B, Cobelli C, Renard E, Anderson S, Breton M, Patek S, Clarke W, Bruttomesso D, Maran A, Costa S, Avogaro A, Dalla Man C, Facchinetti A, Magni L, De Nicolao G, Place J, Farret A: Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: Summary of the results. J Diabetes Sci Technol 2010;4:1374-1381
-
(2010)
J Diabetes Sci Technol
, vol.4
, pp. 1374-1381
-
-
Kovatchev, B.1
Cobelli, C.2
Renard, E.3
Anderson, S.4
Breton, M.5
Patek, S.6
Clarke, W.7
Bruttomesso, D.8
Maran, A.9
Costa, S.10
Avogaro, A.11
Dalla Man, C.12
Facchinetti, A.13
Magni, L.14
De Nicolao, G.15
Place, J.16
Farret, A.17
-
7
-
-
39749162930
-
An improved PID switching control strategy for type 1 diabetes
-
IEEE
-
Marchetti G, Barolo M, Jovanovi-c L, Zisser H, Seborg DE: An improved PID switching control strategy for type 1 diabetes. IEEE Trans Biomed Eng 2008;55:857-865
-
(2008)
Trans Biomed Eng
, vol.55
, pp. 857-865
-
-
Marchetti, G.1
Barolo, M.2
Jovanovi-c, L.3
Zisser, H.4
Seborg, D.E.5
-
8
-
-
48649083317
-
Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
-
Weinzimer SA, Steil GM, Swan KL, Dziura J, Kurtz N, Tamborlane WV: Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care 2008;31:934-939
-
(2008)
Diabetes Care
, vol.31
, pp. 934-939
-
-
Weinzimer, S.A.1
Steil, G.M.2
Swan, K.L.3
Dziura, J.4
Kurtz, N.5
Tamborlane, W.V.6
-
9
-
-
58549088981
-
Intensive insulin therapy: Enhanced model predictive control algorithm versus standard care
-
Cordingley J, Vlasselaers D, Dormand NC, Wouters PJ, Squire SD, Chassin LJ, Wilinska ME, Morgan CJ, Hovorka R, Van den Berghe G: Intensive insulin therapy: Enhanced model predictive control algorithm versus standard care. Intensive Care Med 2009;35:123-128
-
(2009)
Intensive Care Med
, vol.35
, pp. 123-128
-
-
Cordingley, J.1
Vlasselaers, D.2
Dormand, N.C.3
Wouters, P.J.4
Squire, S.D.5
Chassin, L.J.6
Wilinska, M.E.7
Morgan, C.J.8
Hovorka, R.9
Van Den Berghe, G.10
-
10
-
-
70349769396
-
Model predictive control of glucose concentration in type 1 diabetic patients: An in silico trial
-
Magni L, Raimondo DM, Dalla Man C, De Nicolao G, Kovatchev B, Cobelli C: Model predictive control of glucose concentration in type 1 diabetic patients: An in silico trial. Biomed Signal Processing Control 2009;4:338-346
-
(2009)
Biomed Signal Processing Control
, vol.4
, pp. 338-346
-
-
Magni, L.1
Raimondo, D.M.2
Dalla Man, C.3
De Nicolao, G.4
Kovatchev, B.5
Cobelli, C.6
-
11
-
-
84882280877
-
Proposed closed-loop control using fuzzy logic controller and adaptation [abstract A109]
-
Bethesda, MD, November
-
Matheson D, Kircher R, Mauseth R: Proposed closed-loop control using fuzzy logic controller and adaptation [abstract A109]. Poster presentation at the Diabetes Technology Society Meeting, Bethesda, MD, November 13-15, 2008
-
(2008)
Poster Presentation At The Diabetes Technology Society Meeting
, pp. 13-115
-
-
Matheson, D.1
Kircher, R.2
Mauseth, R.3
-
12
-
-
78049505191
-
Proposed clinical application for tuning fuzzy logic controller of artificial pancreas utilizing a personalization factor
-
Mauseth R,Wang Y, Dassau E, Kircher R, Matheson D, Zisser H, Jovanovic L, Doyle F: Proposed clinical application for tuning fuzzy logic controller of artificial pancreas utilizing a personalization factor. J Diabetes Sci Technol 2010;4:913-922
-
(2010)
J Diabetes Sci Technol
, vol.4
, pp. 913-922
-
-
Mauseth, R.1
Wang, Y.2
Dassau, E.3
Kircher, R.4
Matheson, D.5
Zisser, H.6
Jovanovic, L.7
Doyle, F.8
-
13
-
-
0031578033
-
Recommendations guiding physicians in biomedical research involving human subjects
-
World Medical Association Declaration of Helsinki
-
World Medical Association Declaration of Helsinki. Recommendations guiding physicians in biomedical research involving human subjects. JAMA 1997;277:925-926
-
(1997)
JAMA
, vol.277
, pp. 925-926
-
-
-
14
-
-
0016368711
-
Application of fuzzy algorithms for control of simple dynamic plant
-
Mamdani EH: Application of fuzzy algorithms for control of simple dynamic plant. Proc IEE 1974;121:1585-1588
-
(1974)
Proc IEE
, vol.121
, pp. 1585-1588
-
-
Mamdani, E.H.1
-
15
-
-
79952294031
-
In silico model and computer simulation environment approximating the human glucose/insulin utilization
-
Rockville, MD: Food and Drug Administration
-
Kovatchev B, Breton M, Dalla Man C, Cobelli C: In silico model and computer simulation environment approximating the human glucose/insulin utilization. Food and Drug Administration Master File MAF 1521. Rockville, MD: Food and Drug Administration, 2008
-
(2008)
Food and Drug Administration Master File MAF 1521
-
-
Kovatchev, B.1
Breton, M.2
Dalla Man, C.3
Cobelli, C.4
-
16
-
-
61849127306
-
Effect of age of infusion site and type of rapid-acting analog on pharmacodynamic parameters of insulin boluses in youth with type 1 diabetes receiving insulin pump therapy
-
Swan KL, Dziura JD, Steil GM, Voskanyan GR, Sikes KA, Steffen AT, Martin ML, Tamborlane WV, Weinzimer SA: Effect of age of infusion site and type of rapid-acting analog on pharmacodynamic parameters of insulin boluses in youth with type 1 diabetes receiving insulin pump therapy. Diabetes Care 2009;32:240-244
-
(2009)
Diabetes Care
, vol.32
, pp. 240-244
-
-
Swan, K.L.1
Dziura, J.D.2
Steil, G.M.3
Voskanyan, G.R.4
Sikes, K.A.5
Steffen, A.T.6
Martin, M.L.7
Tamborlane, W.V.8
Weinzimer, S.A.9
-
17
-
-
77954901769
-
MDLogic artificial pancreas system: A pilot study in adults with type 1 diabetes
-
Atlas E, Nimri R, Miller S, Grunberg EA, Phillip M: MDLogic artificial pancreas system: A pilot study in adults with type 1 diabetes. Diabetes Care 2010;33:1072-1076
-
(2010)
Diabetes Care
, vol.33
, pp. 1072-1076
-
-
Atlas, E.1
Nimri, R.2
Miller, S.3
Grunberg, E.A.4
Phillip, M.5
-
18
-
-
84874368884
-
Nocturnal glucose control with an artificial pancreas at a diabetes camp
-
Phillip M, Battelino T, Atlas E, Kordonouri O, Bratina N, Miller S, Biester T, Stefanija MA, Muller I, Nimri R, Danne T: Nocturnal glucose control with an artificial pancreas at a diabetes camp. N Engl J Med 2013;368:824-833
-
(2013)
N Engl J Med
, vol.368
, pp. 824-833
-
-
Phillip, M.1
Battelino, T.2
Atlas, E.3
Kordonouri, O.4
Bratina, N.5
Miller, S.6
Biester, T.7
Stefanija, M.A.8
Muller, I.9
Nimri, R.10
Danne, T.11
|