메뉴 건너뛰기




Volumn , Issue , 2013, Pages 280-283

A Neural Network-based method for continuous blood pressure estimation from a PPG signal

Author keywords

blood pressure; hypertension; neural networks; photoplethysmography

Indexed keywords

BLOOD PRESSURE ESTIMATION; HYPERTENSION; INTELLIGENT MONITORING; LINEAR REGRESSION METHODS; MEDICAL INSTRUMENTATION; NATIONAL STANDARD; PHOTOPLETHYSMOGRAPHY (PPG); PRESSURE VARIATIONS;

EID: 84882238014     PISSN: 10915281     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/I2MTC.2013.6555424     Document Type: Conference Paper
Times cited : (272)

References (17)
  • 1
    • 0041382618 scopus 로고    scopus 로고
    • Ambulatory blood pressure monitoring
    • DOI 10.1097/01.SMJ.0000056656.61959.95
    • M. E. Ernst, G. R. Bergus, "Ambulatory blood pressure monitoring," Southern Medical Journal, vol. 96(6), pp. 563-568, June 2003. (Pubitemid 38281715)
    • (2003) Southern Medical Journal , vol.96 , Issue.6 , pp. 563-568
    • Ernst, M.E.1    Bergus, G.R.2
  • 2
    • 33846934749 scopus 로고    scopus 로고
    • Noninvasive estimation of blood pressure using photoplethysmographic signals in the period domain
    • 1617255, Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
    • Y.S. Yan, Y.T. Zhang, "Noninvasive estimation of blood pressure using photoplethysmographic signals in the period domain," Proc. of 27th Annual International Conference of the Engineering in Medicine and Biology Society (IEEE-EMBS 2005), 2005, pp.3583-3584. (Pubitemid 46229704)
    • (2005) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , pp. 3583-3584
    • Yan, Y.S.1    Zhang, Y.T.2
  • 3
    • 84855447017 scopus 로고    scopus 로고
    • Analyzing the windkessel model as a potential candidate for correcting oscillometric blood-pressure measurements
    • Feb
    • K. Barbé, W. Van Moer, D. Schoors, "Analyzing the windkessel model as a potential candidate for correcting oscillometric blood-pressure measurements," IEEE Trans. on Instrum. and Measur., vol.61, no.2, pp.411-418, Feb. 2012.
    • (2012) IEEE Trans. on Instrum. and Measur. , vol.61 , Issue.2 , pp. 411-418
    • Barbé, K.1    Van Moer, W.2    Schoors, D.3
  • 4
    • 51949092648 scopus 로고    scopus 로고
    • A novel parameter from PPG dicrotic notch for estimation of systolic blood pressure using pulse transit time
    • W. B. Gu, C. C. Y. Poon, Y. T. Zhang, "A novel parameter from PPG dicrotic notch for estimation of systolic blood pressure using pulse transit time," Medical Devices and Biosensors (ISSS-MDBS 2008), 2008, pp.86-88.
    • (2008) Medical Devices and Biosensors (ISSS-MDBS 2008) , pp. 86-88
    • Gu, W.B.1    Poon, C.C.Y.2    Zhang, Y.T.3
  • 9
    • 34047169894 scopus 로고    scopus 로고
    • Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics
    • DOI 10.1109/IEMBS.2006.260590, 4029652, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
    • D.B. McCombie, A.T. Reisner, H. Harry Asada, "Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics," Proc. of 28th Annual International Conference of the IEEE Eng. in Medicine and Biology Society (EMBS '06), 2006, pp. 3521-3524. (Pubitemid 46520668)
    • (2006) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , pp. 3521-3524
    • McCombie, D.B.1    Reisner, A.T.2    Asada, H.H.3
  • 11
    • 84879844480 scopus 로고    scopus 로고
    • Nonconstrained blood pressure measurement by photoplethysmography
    • June
    • Y. Yoon, G. Yoon, "Nonconstrained blood pressure measurement by photoplethysmography," Journal of the Optical Society of Korea, vol.10, no.2, pp. 91-95, June 2006.
    • (2006) Journal of the Optical Society of Korea , vol.10 , Issue.2 , pp. 91-95
    • Yoon, Y.1    Yoon, G.2
  • 12
    • 77954403717 scopus 로고    scopus 로고
    • PPG-based methods for non invasive and continuous BP measurement: An overview and development issues in body sensor networks
    • Ottawa, ON
    • G. Fortino, V. Giampà, "PPG-based methods for non invasive and continuous BP measurement: an overview and development issues in body sensor networks," Proc. of IEEE Int. Workshop on Medical Measur. and Applications (MeMeA'2010), Ottawa, ON, 2010, pp.10-13.
    • (2010) Proc. of IEEE Int. Workshop on Medical Measur. and Applications (MeMeA'2010) , pp. 10-13
    • Fortino, G.1    Giampà, V.2
  • 14
    • 84880566152 scopus 로고    scopus 로고
    • Smartphone-based photoplethysmogram measurement
    • R.J. Duro and F. López-Peña Ed. Aalborg, Denmark: River Publishers
    • Yu. Kurylyak, F. Lamonaca, D. Grimaldi, "Smartphone-Based Photoplethysmogram Measurement," in Digital Image, Signal and Data Processing, R.J. Duro and F. López-Peña Ed. Aalborg, Denmark: River Publishers, 2012, pp. 135-164.
    • (2012) Digital Image, Signal and Data Processing , pp. 135-164
    • Kurylyak, Yu.1    Lamonaca, F.2    Grimaldi, D.3
  • 16
    • 33745958996 scopus 로고    scopus 로고
    • Using the morphology of photoplethysmogram peaks to detect changes in posture
    • DOI 10.1007/s10877-006-9015-2
    • S. Linder, S. Wendelken, E. Wei, and S. McGrath, "Using the morphology of photoplethysmogram peaks to detect changes in posture," Journal of Clinical Monitoring and Computing, vol.20(3), pp.151-158, June 2006. (Pubitemid 44056929)
    • (2006) Journal of Clinical Monitoring and Computing , vol.20 , Issue.3 , pp. 151-158
    • Linder, S.P.1    Wendelken, S.M.2    Wei, E.3    McGrath, S.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.