1
-
-
0034986810
-
Extracting arterial flow waveforms from pulse oximeter waveforms apparatus
-
Cook LB. Extracting arterial flow waveforms from pulse oximeter waveforms apparatus. Anaesthesia 2001;56(6):551-555.
-
(2001)
Anaesthesia
, vol.56
, Issue.6
, pp. 551-555
-
-
Cook, L.B.1
-
2
-
-
0034987645
-
Arterial flow waveforms from pulse oximetry compared with measured Doppler flow waveforms apparatus
-
Wisely NA, Cook LB. Arterial flow waveforms from pulse oximetry compared with measured Doppler flow waveforms apparatus. Anaesthesia 2001;56(6):556-561.
-
(2001)
Anaesthesia
, vol.56
, Issue.6
, pp. 556-561
-
-
Wisely, N.A.1
Cook, L.B.2
-
3
-
-
0030249948
-
The peripheral pulse wave: Information overlooked
-
Murray WB, Foster PA. The peripheral pulse wave: Information overlooked. J Clin Monit 1996;12:365-377.
-
(1996)
J Clin Monit
, vol.12
, pp. 365-377
-
-
Murray, W.B.1
Foster, P.A.2
-
4
-
-
0030032649
-
Signal processing methods for pulse oximetry
-
Rusch TL, Sankar R, Scharf JE. Signal processing methods for pulse oximetry. Comput. Bol. Med. 1996;26(2):143-159.
-
(1996)
Comput. Bol. Med.
, vol.26
, Issue.2
, pp. 143-159
-
-
Rusch, T.L.1
Sankar, R.2
Scharf, J.E.3
-
5
-
-
1542283518
-
Pulse Oximeter Waveform: Photoelectric Plethysmography
-
Carol Lake, Hines R, Blitt C (eds.)
-
Shelley K, Shelley S. Pulse Oximeter Waveform: Photoelectric Plethysmography. In: Carol Lake, Hines R, Blitt C (eds.), Clinical Monitoring: W.B. Saunders Company 2001:420-428.
-
(2001)
Clinical Monitoring: W.B. Saunders Company
, pp. 420-428
-
-
Shelley, K.1
Shelley, S.2
-
6
-
-
11144318651
-
Extracting Breathing Rate Information from a Wearable Reflectance Pulse Oximeter
-
Paper presented at: International Conference of the IEEE EMBS, San Francisco, CA, USA
-
Johnston WS, Mendelson Y. Extracting Breathing Rate Information from a Wearable Reflectance Pulse Oximeter. Paper presented at: International Conference of the IEEE EMBS, 2004; San Francisco, CA, USA.
-
(2004)
-
-
Johnston, W.S.1
Mendelson, Y.2
-
7
-
-
0041863311
-
Biomonitoring with wireless communications
-
Budinger TF. Biomonitoring with wireless communications. Annu Rev Biomed Eng 2003;5:383-412.
-
(2003)
Annu Rev Biomed Eng
, vol.5
, pp. 383-412
-
-
Budinger, T.F.1
-
8
-
-
19944375078
-
Lifeguard - A Personal Physiological Monitor For Extreme Environments
-
Paper presented at: International Conference of the IEEE EMBS, San Francisco, CA, USA
-
Montgomery K, Mundt C, Thonier G, Tellier A, Udoh U, Barker V, et al. Lifeguard - A Personal Physiological Monitor For Extreme Environments. Paper presented at: International Conference of the IEEE EMBS, 2004; San Francisco, CA, USA.
-
(2004)
-
-
Montgomery, K.1
Mundt, C.2
Thonier, G.3
Tellier, A.4
Udoh, U.5
Barker, V.6
-
9
-
-
10644263638
-
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
-
Anliker U, Ward JA, Lukowicz P, Tröster G, Dolveck F, Baer M, et al. AMON: A Wearable Multiparameter Medical Monitoring and Alert System. IEEE Trans Inf Technol Biomed 2004;8(4):415-427.
-
(2004)
IEEE Trans Inf Technol Biomed
, vol.8
, Issue.4
, pp. 415-427
-
-
Anliker, U.1
Ward, J.A.2
Lukowicz, P.3
Tröster, G.4
Dolveck, F.5
Baer, M.6
-
10
-
-
1642293151
-
Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans
-
Cooke WH, Ryan KL. Convertino VA. Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans. J Appl Physiol 2004;98:1249-1261.
-
(2004)
J Appl Physiol
, vol.98
, pp. 1249-1261
-
-
Cooke, W.H.1
Ryan, K.L.2
Convertino, V.A.3
-
11
-
-
0033963925
-
Cardiovascular response to acute hypovolemia in relation to age. Implications for orthostasis and hemorrhage
-
Olsen H, Vernersson E, Länne T. Cardiovascular response to acute hypovolemia in relation to age. Implications for orthostasis and hemorrhage. AJP- Heart and Circulatory Physiology 2000;278:H222-H232.
-
(2000)
AJP- Heart and Circulatory Physiology
, vol.278
-
-
Olsen, H.1
Vernersson, E.2
Länne, T.3
-
12
-
-
0032953278
-
Pulse oximetry plethysmographic waveform during changes in blood volume
-
Shamir M, Eidelman LA, Floman Y, Kaplan L, Pizov R. Pulse oximetry plethysmographic waveform during changes in blood volume. Br J Anaesth 1999;82(2):178-181.
-
(1999)
Br J Anaesth
, vol.82
, Issue.2
, pp. 178-181
-
-
Shamir, M.1
Eidelman, L.A.2
Floman, Y.3
Kaplan, L.4
Pizov, R.5
-
15
-
-
1242284327
-
Respiratory sinus arrhythmia: Why does the heartbeat synchronize with respiratory rhythm?
-
Yasuma F, Hayano J-I. Respiratory sinus arrhythmia: Why does the heartbeat synchronize with respiratory rhythm? Chest 2004;125(2):683-690.
-
(2004)
Chest
, vol.125
, Issue.2
, pp. 683-690
-
-
Yasuma, F.1
Hayano, J.-I.2
-
16
-
-
0034448449
-
Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique
-
Nilsson L, Johansson A, Kalman S. Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique. J Clin Monit Comput 2000;16:309-315.
-
(2000)
J Clin Monit Comput
, vol.16
, pp. 309-315
-
-
Nilsson, L.1
Johansson, A.2
Kalman, S.3
-
17
-
-
0344119620
-
Macrocirculation is not the sole determinant of respiratory induced variations in the reflection mode photoplethysmographic signal
-
Nilsson L, Johansson A, Kalman S. Macrocirculation is not the sole determinant of respiratory induced variations in the reflection mode photoplethysmographic signal. Physiol Meas 2003;24(4):925-937.
-
(2003)
Physiol Meas
, vol.24
, Issue.4
, pp. 925-937
-
-
Nilsson, L.1
Johansson, A.2
Kalman, S.3
-
18
-
-
75949137005
-
NAC. Respiratory sinus arrhythmia: A frequency dependent phenomenon
-
Angelone A, Jr. NAC. Respiratory sinus arrhythmia: A frequency dependent phenomenon. J Appl Physiol 1964;19:479-482.
-
(1964)
J Appl Physiol
, vol.19
, pp. 479-482
-
-
Angelone Jr., A.1
-
19
-
-
0029814135
-
Heart rate variability during repeated incremental head-up tilt discloses time dependence of individual autonomic dynamics
-
Bootsma M, Swenne CA, Bruschke AV. Heart rate variability during repeated incremental head-up tilt discloses time dependence of individual autonomic dynamics. Clin Cardiol 1996;19(1):62-68.
-
(1996)
Clin Cardiol
, vol.19
, Issue.1
, pp. 62-68
-
-
Bootsma, M.1
Swenne, C.A.2
Bruschke, A.V.3
-
20
-
-
0344765505
-
A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function
-
Gratze G, Fortin J, Holler A, Grasenick K, Pfurtscheller G, Wach P, et al. A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function. Computers in Biology & Medicine 1998;28(2):121-142.
-
(1998)
Computers in Biology & Medicine
, vol.28
, Issue.2
, pp. 121-142
-
-
Gratze, G.1
Fortin, J.2
Holler, A.3
Grasenick, K.4
Pfurtscheller, G.5
Wach, P.6
-
21
-
-
0029928495
-
Heart rate variability: Standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology
-
anonymous
-
anonymous. Heart rate variability: Standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Circulation 1996;93(5):1043-1065.
-
(1996)
Circulation
, vol.93
, Issue.5
, pp. 1043-1065
-
-
-
22
-
-
0037842965
-
Neural network for photoplethysmographic respiratory rate monitoring
-
Johansson A. Neural network for photoplethysmographic respiratory rate monitoring. Medical & Biomedical Engineering & Computing 2003;41:242-248.
-
(2003)
Medical & Biomedical Engineering & Computing
, vol.41
, pp. 242-248
-
-
Johansson, A.1
-
23
-
-
14544301424
-
The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in Spo2 calculation
-
Shelley KH, Tamai D, Jablonka D, Gesquiere M, Stout RG, Silverman DG. The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in Spo2 calculation. Anesth Analg 2005;10:743-747.
-
(2005)
Anesth Analg
, vol.10
, pp. 743-747
-
-
Shelley, K.H.1
Tamai, D.2
Jablonka, D.3
Gesquiere, M.4
Stout, R.G.5
Silverman, D.G.6
-
24
-
-
0023428633
-
Use of pulse oximetry as a noninvasive indicator of intravascular volume status
-
Partridge BL. Use of pulse oximetry as a noninvasive indicator of intravascular volume status. J Clin Monit 1987;3(4): 263-268.
-
(1987)
J Clin Monit
, vol.3
, Issue.4
, pp. 263-268
-
-
Partridge, B.L.1
-
25
-
-
21244482589
-
Tracking highly maneuverable targets with unknown behavior
-
Schell C, Linder SP, Zeider JR. Tracking highly maneuverable targets with unknown behavior. Proceedings of the IEEE 2004;92(3):558-574.
-
(2004)
Proceedings of the IEEE
, vol.92
, Issue.3
, pp. 558-574
-
-
Schell, C.1
Linder, S.P.2
Zeider, J.R.3
-
26
-
-
0035024813
-
Different responses of ear and finger pulse oximeter wave form to cold pressor test
-
Awad AA, Ghobashy MA, Ouda W, Stout RG, Silverman DG, Shelley KH. Different responses of ear and finger pulse oximeter wave form to cold pressor test. Anesth Analg 2001;92(6):1483-1486.
-
(2001)
Anesth Analg
, vol.92
, Issue.6
, pp. 1483-1486
-
-
Awad, A.A.1
Ghobashy, M.A.2
Ouda, W.3
Stout, R.G.4
Silverman, D.G.5
Shelley, K.H.6
-
27
-
-
33745965201
-
The effect of Vasopressin on ear pulse plethysmography and its implications on cerebral blood flow regulation
-
Paper presented at: ASA Annual Meeting, Las Vegas, Nevada
-
Jablonka DH, Awad AA, Tamai DN, Stout RG, Silverman DG, Shelley KH. The effect of Vasopressin on ear pulse plethysmography and its implications on cerebral blood flow regulation. Paper presented at: ASA Annual Meeting, Las Vegas, Nevada 2004.
-
(2004)
-
-
Jablonka, D.H.1
Awad, A.A.2
Tamai, D.N.3
Stout, R.G.4
Silverman, D.G.5
Shelley, K.H.6
|