메뉴 건너뛰기




Volumn 39, Issue 9, 2013, Pages 1580-1595

Experimental methods for improved spatial control of thermal lesions in magnetic resonance-guided focused ultrasound ablation

Author keywords

Boiling core; Cavitation; Magnetic resonance guided high intensity focused ultrasound; Pre clinical quality assurance; Safety profile; Targeting

Indexed keywords

ABLATION; APPLICATORS; CAVITATION; PHASE TRANSITIONS; QUALITY ASSURANCE; TISSUE; TRANSDUCERS; ULTRASONIC APPLICATIONS; ULTRASONICS;

EID: 84881663247     PISSN: 03015629     EISSN: 1879291X     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2013.03.018     Document Type: Article
Times cited : (11)

References (49)
  • 1
    • 79958096340 scopus 로고    scopus 로고
    • An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy
    • Auboiroux V., Dumont E., Petrusca L., Viallon M., Salomir R. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy. Phys Med Biol 2011, 56:3563-3582.
    • (2011) Phys Med Biol , vol.56 , pp. 3563-3582
    • Auboiroux, V.1    Dumont, E.2    Petrusca, L.3    Viallon, M.4    Salomir, R.5
  • 4
    • 84863191313 scopus 로고    scopus 로고
    • Shock wave emission from a cloud of bubbles
    • Brujan E.A., Ikeda T., Matsumoto Y. Shock wave emission from a cloud of bubbles. Soft Matter 2012, 8:5777.
    • (2012) Soft Matter , vol.8 , pp. 5777
    • Brujan, E.A.1    Ikeda, T.2    Matsumoto, Y.3
  • 5
    • 53949122484 scopus 로고    scopus 로고
    • Acoustic characterization of high intensity focused ultrasound fields: A combined measurement and modeling approach
    • Canney M.S., Bailey M.R., Crum L.A., Khokhlova V.A., Sapozhnikov O.A. Acoustic characterization of high intensity focused ultrasound fields: A combined measurement and modeling approach. JAcoust Soc Am 2008, 124:2406-2420.
    • (2008) JAcoust Soc Am , vol.124 , pp. 2406-2420
    • Canney, M.S.1    Bailey, M.R.2    Crum, L.A.3    Khokhlova, V.A.4    Sapozhnikov, O.A.5
  • 6
    • 74849103216 scopus 로고    scopus 로고
    • Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound
    • Canney M.S., Khokhlova V.A., Bessonova O.V., Bailey M.R., Crum L.A. Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound. Ultrasound Med Biol 2010, 36:250-267.
    • (2010) Ultrasound Med Biol , vol.36 , pp. 250-267
    • Canney, M.S.1    Khokhlova, V.A.2    Bessonova, O.V.3    Bailey, M.R.4    Crum, L.A.5
  • 7
    • 33750841780 scopus 로고    scopus 로고
    • The use of a segmented transducer for rib sparing in HIFU treatments
    • Civale J., Clarke R., Rivens I., ter Haar G. The use of a segmented transducer for rib sparing in HIFU treatments. Ultrasound Med Biol 2006, 32:1753-1761.
    • (2006) Ultrasound Med Biol , vol.32 , pp. 1753-1761
    • Civale, J.1    Clarke, R.2    Rivens, I.3    ter Haar, G.4
  • 10
    • 0000872778 scopus 로고
    • Production of focal destructive lesions in the central nervous system with ultrasound
    • Fry W.J., Mosberg W.H., Barnard J.W., Fry F.J. Production of focal destructive lesions in the central nervous system with ultrasound. JNeurosurg 1954, 11:471-478.
    • (1954) JNeurosurg , vol.11 , pp. 471-478
    • Fry, W.J.1    Mosberg, W.H.2    Barnard, J.W.3    Fry, F.J.4
  • 12
    • 53749095088 scopus 로고    scopus 로고
    • Palliative treatment of painful bone metastases with MR imaging-guided focused ultrasound
    • Gianfelice D., Gupta C., Kucharczyk W., Bret P., Havill D., Clemons M. Palliative treatment of painful bone metastases with MR imaging-guided focused ultrasound. Radiology 2008, 249:355-363.
    • (2008) Radiology , vol.249 , pp. 355-363
    • Gianfelice, D.1    Gupta, C.2    Kucharczyk, W.3    Bret, P.4    Havill, D.5    Clemons, M.6
  • 13
    • 0345688804 scopus 로고    scopus 로고
    • MR imaging-guided focused ultrasound surgery of breast cancer: Correlation of dynamic contrast-enhanced MRI with histopathologic findings
    • Gianfelice D., Khiat A., Amara M., Belblidia A., Boulanger Y. MR imaging-guided focused ultrasound surgery of breast cancer: Correlation of dynamic contrast-enhanced MRI with histopathologic findings. Breast Cancer Res Treat 2003, 82:93-101.
    • (2003) Breast Cancer Res Treat , vol.82 , pp. 93-101
    • Gianfelice, D.1    Khiat, A.2    Amara, M.3    Belblidia, A.4    Boulanger, Y.5
  • 14
    • 0037612192 scopus 로고    scopus 로고
    • MR imaging-guided focused US ablation of breast cancer: Histopathologic assessment of effectiveness-Initial experience
    • Gianfelice D., Khiat A., Amara M., Belblidia A., Boulanger Y. MR imaging-guided focused US ablation of breast cancer: Histopathologic assessment of effectiveness-Initial experience. Radiology 2003, 227:849-855.
    • (2003) Radiology , vol.227 , pp. 849-855
    • Gianfelice, D.1    Khiat, A.2    Amara, M.3    Belblidia, A.4    Boulanger, Y.5
  • 15
    • 0142026382 scopus 로고    scopus 로고
    • Feasibility of magnetic resonance imaging-guided focused ultrasound surgery as an adjunct to tamoxifen therapy in high-risk surgical patients with breast carcinoma
    • Gianfelice D., Khiat A., Boulanger Y., Amara M., Belblidia A. Feasibility of magnetic resonance imaging-guided focused ultrasound surgery as an adjunct to tamoxifen therapy in high-risk surgical patients with breast carcinoma. JVasc Interv Radiol 2003, 14:1275-1282.
    • (2003) JVasc Interv Radiol , vol.14 , pp. 1275-1282
    • Gianfelice, D.1    Khiat, A.2    Boulanger, Y.3    Amara, M.4    Belblidia, A.5
  • 18
    • 84881665706 scopus 로고    scopus 로고
    • MRI monitoring of skull-base heating in transcranial focused ultrasound ablation
    • Huang Y., Song J., Hynynen K. MRI monitoring of skull-base heating in transcranial focused ultrasound ablation. Proc. Int. Soc. Mag. Reson. Med 2010, 18:249.
    • (2010) Proc. Int. Soc. Mag. Reson. Med , vol.18 , pp. 249
    • Huang, Y.1    Song, J.2    Hynynen, K.3
  • 21
    • 0029298735 scopus 로고
    • MR monitoring of focused ultrasonic surgery of renal cortex: Experimental and simulation studies
    • Hynynen K., Damianou C.A., Colucci V., Unger E., Cline H.H., Jolesz F.A. MR monitoring of focused ultrasonic surgery of renal cortex: Experimental and simulation studies. JMagn Reson Imaging 1995, 5:259-266.
    • (1995) JMagn Reson Imaging , vol.5 , pp. 259-266
    • Hynynen, K.1    Damianou, C.A.2    Colucci, V.3    Unger, E.4    Cline, H.H.5    Jolesz, F.A.6
  • 22
    • 33746242230 scopus 로고    scopus 로고
    • Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain: a primate study
    • Hynynen K., McDannold N., Clement G., Jolesz F.A., Zadicario E., Killiany R., Moore T., Rosen D. Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain: a primate study. Eur J Radiol 2006, 59:149-156.
    • (2006) Eur J Radiol , vol.59 , pp. 149-156
    • Hynynen, K.1    McDannold, N.2    Clement, G.3    Jolesz, F.A.4    Zadicario, E.5    Killiany, R.6    Moore, T.7    Rosen, D.8
  • 23
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen K., McDannold N., Vykhodtseva N., Jolesz F.A. Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 2001, 220:640-646.
    • (2001) Radiology , vol.220 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 26
    • 67650753865 scopus 로고    scopus 로고
    • MRI-guided focused ultrasound surgery
    • Jolesz F.A. MRI-guided focused ultrasound surgery. Annu Rev Med 2009, 60:417-430.
    • (2009) Annu Rev Med , vol.60 , pp. 417-430
    • Jolesz, F.A.1
  • 28
    • 33644661412 scopus 로고    scopus 로고
    • Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phant
    • Khokhlova V.A., Bailey M.R., Reed J.A., Cunitz B.W., Kaczkowski P.J., Crum L.A. Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phant. JAcoust Soc Am 2006, 119:1834-1848.
    • (2006) JAcoust Soc Am , vol.119 , pp. 1834-1848
    • Khokhlova, V.A.1    Bailey, M.R.2    Reed, J.A.3    Cunitz, B.W.4    Kaczkowski, P.J.5    Crum, L.A.6
  • 30
    • 73849158393 scopus 로고
    • Asimple method for production of trackless focal lesions with focused ultrasound: Physical factors
    • Lele P.P. Asimple method for production of trackless focal lesions with focused ultrasound: Physical factors. JPhysiol 1962, 160:494-512.
    • (1962) JPhysiol , vol.160 , pp. 494-512
    • Lele, P.P.1
  • 31
    • 37049195387 scopus 로고
    • The biological application of focused ultrasonic waves
    • Lynn J.G., Zwemer R.L., Chick A.J. The biological application of focused ultrasonic waves. Science 1942, 96:119-120.
    • (1942) Science , vol.96 , pp. 119-120
    • Lynn, J.G.1    Zwemer, R.L.2    Chick, A.J.3
  • 32
    • 48349094599 scopus 로고    scopus 로고
    • Magnetic resonance acoustic radiation force imaging
    • McDannold N., Maier S.E. Magnetic resonance acoustic radiation force imaging. Med Phys 2008, 35:3748-3758.
    • (2008) Med Phys , vol.35 , pp. 3748-3758
    • McDannold, N.1    Maier, S.E.2
  • 33
    • 0037225633 scopus 로고    scopus 로고
    • Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh
    • Palussiere J., Salomir R., Le Bail B., Fawaz R., Quesson B., Grenier N., Moonen C.T. Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh. Magn Reson Med 2003, 49:89-98.
    • (2003) Magn Reson Med , vol.49 , pp. 89-98
    • Palussiere, J.1    Salomir, R.2    Le Bail, B.3    Fawaz, R.4    Quesson, B.5    Grenier, N.6    Moonen, C.T.7
  • 34
    • 0032924339 scopus 로고    scopus 로고
    • Heat-source orientation and geometry dependence in proton-resonance frequency shift magnetic resonance thermometry
    • Peters R.D., Hinks R.S., Henkelman R.M. Heat-source orientation and geometry dependence in proton-resonance frequency shift magnetic resonance thermometry. Magn Reson Med 1999, 41:909-918.
    • (1999) Magn Reson Med , vol.41 , pp. 909-918
    • Peters, R.D.1    Hinks, R.S.2    Henkelman, R.M.3
  • 37
    • 2542450088 scopus 로고    scopus 로고
    • Microbubble contrast agents for echocardiography: Rationale, composition, ultrasound interactions, and safety
    • Raisinghani A., Rafter P., Phillips P., Vannan M.A., DeMaria A.N. Microbubble contrast agents for echocardiography: Rationale, composition, ultrasound interactions, and safety. Cardiol Clin 2004, 22:171-180.
    • (2004) Cardiol Clin , vol.22 , pp. 171-180
    • Raisinghani, A.1    Rafter, P.2    Phillips, P.3    Vannan, M.A.4    DeMaria, A.N.5
  • 38
    • 58149267910 scopus 로고    scopus 로고
    • Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy
    • Rata M., Salomir R., Umathum R., Jenne J., Lafon C., Cotton F., Bock M. Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy. Phys Med Biol 2008, 53:6549-6567.
    • (2008) Phys Med Biol , vol.53 , pp. 6549-6567
    • Rata, M.1    Salomir, R.2    Umathum, R.3    Jenne, J.4    Lafon, C.5    Cotton, F.6    Bock, M.7
  • 39
    • 0031778811 scopus 로고    scopus 로고
    • Observations of shock waves in cloud cavitation
    • Reisman G.E., Wang Y.C., Brennen C.E. Observations of shock waves in cloud cavitation. J. Fluid Mech 1998, 355:255-283.
    • (1998) J. Fluid Mech , vol.355 , pp. 255-283
    • Reisman, G.E.1    Wang, Y.C.2    Brennen, C.E.3
  • 40
    • 51849088469 scopus 로고    scopus 로고
    • MR temperature monitoring applying the proton resonance frequency method in liver and kidney at 0.2 and 1.5 T: Segment-specific attainable precision and breathing influence
    • Rempp H., Martirosian P., Boss A., Clasen S., Kickhefel A., Kraiger M., Schraml C., Claussen C., Pereira P., Schick F. MR temperature monitoring applying the proton resonance frequency method in liver and kidney at 0.2 and 1.5 T: Segment-specific attainable precision and breathing influence. MAGMA 2008, 21:333-343.
    • (2008) MAGMA , vol.21 , pp. 333-343
    • Rempp, H.1    Martirosian, P.2    Boss, A.3    Clasen, S.4    Kickhefel, A.5    Kraiger, M.6    Schraml, C.7    Claussen, C.8    Pereira, P.9    Schick, F.10
  • 44
    • 84877585134 scopus 로고    scopus 로고
    • Magnetic resonance-guided shielding of prefocal acoustic obstacles in focused ultrasound therapy: Application to intercostal ablation in liver
    • EPub ahead of print, J 22
    • Salomir R., Petrusca L., Auboiroux V., Muller A., Vargas M.I., Morel D.R., Breguet R., Terraz S., Becker C.D., Viallon M. Magnetic resonance-guided shielding of prefocal acoustic obstacles in focused ultrasound therapy: Application to intercostal ablation in liver. Invest Radiol 2013 January 22, EPub ahead of print.
    • (2013) Invest Radiol
    • Salomir, R.1    Petrusca, L.2    Auboiroux, V.3    Muller, A.4    Vargas, M.I.5    Morel, D.R.6    Breguet, R.7    Terraz, S.8    Becker, C.D.9    Viallon, M.10
  • 45
    • 0034087586 scopus 로고    scopus 로고
    • Hyperthermia by MR-guided focused ultrasound: accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction
    • Salomir R., Vimeux F.C., de Zwart J.A., Grenier N., Moonen C.T. Hyperthermia by MR-guided focused ultrasound: accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction. Magn Reson Med 2000, 43:342-347.
    • (2000) Magn Reson Med , vol.43 , pp. 342-347
    • Salomir, R.1    Vimeux, F.C.2    de Zwart, J.A.3    Grenier, N.4    Moonen, C.T.5
  • 47
    • 0037458224 scopus 로고    scopus 로고
    • MRI-guided gas bubble enhanced ultrasound heating in invivo rabbit thigh
    • Sokka S.D., King R., Hynynen K. MRI-guided gas bubble enhanced ultrasound heating in invivo rabbit thigh. Phys Med Biol 2003, 48:223-241.
    • (2003) Phys Med Biol , vol.48 , pp. 223-241
    • Sokka, S.D.1    King, R.2    Hynynen, K.3
  • 48
    • 53549096544 scopus 로고    scopus 로고
    • Transient MR elastography (t-MRE) using ultrasound radiation force: Theory, safety, and initial experiments invitro
    • Souchon R., Salomir R., Beuf O., Milot L., Grenier D., Lyonnet D., Chapelon J.Y., Rouvière O. Transient MR elastography (t-MRE) using ultrasound radiation force: Theory, safety, and initial experiments invitro. Magn Reson Med 2008, 60:871-881.
    • (2008) Magn Reson Med , vol.60 , pp. 871-881
    • Souchon, R.1    Salomir, R.2    Beuf, O.3    Milot, L.4    Grenier, D.5    Lyonnet, D.6    Chapelon, J.Y.7    Rouvière, O.8
  • 49
    • 77950566822 scopus 로고    scopus 로고
    • Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging
    • Viallon M., Terraz S., Roland J., Dumont E., Becker C.D., Salomir R. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging. Med Phys 2010, 37:1491-1506.
    • (2010) Med Phys , vol.37 , pp. 1491-1506
    • Viallon, M.1    Terraz, S.2    Roland, J.3    Dumont, E.4    Becker, C.D.5    Salomir, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.