Volumn , Issue , 2013, Pages

Multi-criteria based staging of Optimal PMU Placement using Fuzzy Weighted Average

Author keywords

Fuzzy Sets; Fuzzy Weighted Average; Genetic Algorithm; Optimal PMU Placement; Phasor Measurement Units; Power Grid; Staging

Indexed keywords

FUZZY WEIGHTED AVERAGE; INSTALLATION SITE; MEASUREMENT REDUNDANCY; MULTI-CRITERIA DECISION MAKING; PMU PLACEMENT; POWER GRIDS; STAGING; SYSTEM OBSERVABILITY;

EID: 84881650472     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISIE.2013.6563646     Document Type: Conference Paper
Times cited : (6)

References (30)
  • 5
    • 84881659209 scopus 로고    scopus 로고
    • Known secure sensor measurements' for critical infrastructure systems: Detecting falsification of systems state
    • M. McQueen, A. Giani, "'Known Secure Sensor Measurements' for Critical Infrastructure Systems: Detecting Falsification of Systems State," in Proc. of SERENE, 2011.
    • (2011) Proc. of SERENE
    • McQueen, M.1    Giani, A.2
  • 6
    • 0027589817 scopus 로고
    • Power system observability with minimal phasor measurement placement
    • May
    • T. L. Baldwin, L. Mili, M. B. Boisen Jr., R. Adapa, "Power System Observability With Minimal Phasor Measurement Placement," in IEEE Trans. on Power Systems, vol. 8, no.2, pp. 707-715, May 1993.
    • (1993) IEEE Trans. on Power Systems , vol.8 , Issue.2 , pp. 707-715
    • Baldwin, T.L.1    Mili, L.2    Boisen Jr., M.B.3    Adapa, R.4
  • 7
    • 54049116233 scopus 로고    scopus 로고
    • Optimal multistage scheduling of pmu placement: An ilp approach
    • Oct
    • D. Dua, S. Dambhare, R. K. Gajbhiye, S. A. Soman, "Optimal Multistage Scheduling of PMU Placement: An ILP Approach," in IEEE Trans. on Power Delivery, vol. 23, no. 4, pp. 1812-1820, Oct. 2008.
    • (2008) IEEE Trans. on Power Delivery , vol.23 , Issue.4 , pp. 1812-1820
    • Dua, D.1    Dambhare, S.2    Gajbhiye, R.K.3    Soman, S.A.4
  • 8
    • 49249129678 scopus 로고    scopus 로고
    • Generalized integer linear programming formulation for optimal pmu placement
    • Aug
    • B. Gou, "Generalized Integer Linear Programming Formulation for Optimal PMU Placement, " in IEEE Trans. on Power Systems, vol. 23, no. 3, pp. 1099-1104, Aug. 2008.
    • (2008) IEEE Trans. on Power Systems , vol.23 , Issue.3 , pp. 1099-1104
    • Gou, B.1
  • 11
    • 77957564910 scopus 로고    scopus 로고
    • Optimal placement of PMUs to maintain network observability using a modified BPSO algorithm
    • Jan
    • M. Hajian, A. M. Ranjbar, T. Amraee, B. Mozafari, "Optimal placement of PMUs to maintain network observability using a modified BPSO algorithm," in Intl. Journal of Electrical Power & Energy Systems, vol. 33, issue: 1, pp. 28-34, Jan. 2011.
    • (2011) Intl. Journal of Electrical Power & Energy Systems , vol.33 , Issue.1 , pp. 28-34
    • Hajian, M.1    Ranjbar, A.M.2    Amraee, T.3    Mozafari, B.4
  • 12
    • 0142008403 scopus 로고    scopus 로고
    • Genetic algorithms for optimal placement of phasor measurement units in electrical networks
    • Sep
    • F. J. Marin, F. Garcia-Lagos, G. Joya, F. Sandoval, "Genetic algorithms for optimal placement of phasor measurement units in electrical networks," in Electronics Letters, vol. 39, issue: 19, pp. 1403-1405, Sep. 2003.
    • (2003) Electronics Letters , vol.39 , Issue.19 , pp. 1403-1405
    • Marin, F.J.1    Garcia-Lagos, F.2    Joya, G.3    Sandoval, F.4
  • 13
    • 0037292302 scopus 로고    scopus 로고
    • Nondominated sorting genetic algorithm for optimal phasor measurement placement
    • Feb
    • B. Milosevic, M. Begovic, "Nondominated Sorting Genetic Algorithm for Optimal Phasor Measurement Placement," in IEEE Trans. on Power Systems, vol. 18, issue: 1, pp. 69-75, Feb. 2003.
    • (2003) IEEE Trans. on Power Systems , vol.18 , Issue.1 , pp. 69-75
    • Milosevic, B.1    Begovic, M.2
  • 14
    • 67650703200 scopus 로고    scopus 로고
    • Optimal placement of phasor measurement units using immunity genetic algorithm
    • July
    • F. Aminifar, C. Lucas, A. Khodaei, M. Fotuhi-Firuzabad, "Optimal Placement of Phasor Measurement Units Using Immunity Genetic Algorithm, " in IEEE Trans. on Power Delivery, vol. 24, no. 3, pp. 1014-1020, July 2009.
    • (2009) IEEE Trans. on Power Delivery , vol.24 , Issue.3 , pp. 1014-1020
    • Aminifar, F.1    Lucas, C.2    Khodaei, A.3    Fotuhi-Firuzabad, M.4
  • 17
    • 33645532449 scopus 로고    scopus 로고
    • Optimal pmu placement for full network observability using tabu search algorithm
    • May
    • J. Peng, Y. Sun, H. F. Wang, "Optimal PMU placement for full network observability using Tabu search algorithm," in International Journal of Electrical Power & Energy Systems, vol. 28, issue: 4, pp. 223-231, May 2006.
    • (2006) International Journal of Electrical Power & Energy Systems , vol.28 , Issue.4 , pp. 223-231
    • Peng, J.1    Sun, Y.2    Wang, H.F.3
  • 18
    • 49249129032 scopus 로고    scopus 로고
    • Optimal placement of phasor measurement units for power system observability
    • Aug
    • S. Chakrabarti, E. Kyriakides, "Optimal Placement of Phasor Measurement Units for Power System Observability," in IEEE Trans. on Power Systems, vol. 23, no. 3, pp. 1433-1440, Aug. 2008.
    • (2008) IEEE Trans. on Power Systems , vol.23 , Issue.3 , pp. 1433-1440
    • Chakrabarti, S.1    Kyriakides, E.2
  • 21
    • 80054922068 scopus 로고    scopus 로고
    • Joint placement of phasor and power flow measurements for observability of power systems
    • Nov
    • R. Kavesseri, S. K. Srinivasan, "Joint Placement of Phasor and Power Flow Measurements for Observability of Power Systems," in IEEE Trans. on Power Systems, vol. 26, no. 4, pp. 1929-1936, Nov. 2011.
    • (2011) IEEE Trans. on Power Systems , vol.26 , Issue.4 , pp. 1929-1936
    • Kavesseri, R.1    Srinivasan, S.K.2
  • 24
    • 79251502663 scopus 로고    scopus 로고
    • Multi-criteria decision-making approach for multi-stage optimal placement of phasor measurement units
    • R. Sodhi, S. C. Srivastava, S. N. Singh, "Multi-criteria decision-making approach for multi-stage optimal placement of phasor measurement units," in IET Generation, Transmission & Distribution, vol. 5, issue: 2, pp. 181-190, 2011.
    • (2011) IET Generation, Transmission & Distribution , vol.5 , Issue.2 , pp. 181-181
    • Sodhi, R.1    Srivastava, S.C.2    Singh, S.N.3
  • 25
    • 27844462056 scopus 로고    scopus 로고
    • Phasor measurement unit placement techniques for complete and incomplete observability
    • Oct
    • R. F. Nuqui, A. G. Phadke, "Phasor Measurement Unit Placement Techniques for Complete and Incomplete Observability," in IEEE Trans. on Power Delivery, vol. 20, no. 4, pp. 2381-2388, Oct. 2005.
    • (2005) IEEE Trans. on Power Delivery , vol.20 , Issue.4 , pp. 2381-2388
    • Nuqui, R.F.1    Phadke, A.G.2
  • 26
    • 0003722376 scopus 로고
    • Optimization and Machine Learning, Addison-Wesley Professional
    • D. E. Goldberg, Genetic Algorithms in Search, Optimization and Machine Learning, Addison-Wesley Professional, 1989.
    • (1989) Genetic Algorithms in Search
    • Goldberg, D.E.1
  • 28
    • 40549114013 scopus 로고    scopus 로고
    • Aggregation using the fuzzy weighted average, as computed using the Karnik-Mendel Algorithms
    • F. Liu, J. M. Mendel, "Aggregation using the fuzzy weighted average, as computed using the Karnik-Mendel Algorithms," in IEEE Trans. on Fuzzy Systems, vol. 12, no. 1, pp. 1-12, 2008.
    • (2008) IEEE Trans. on Fuzzy Systems , vol.12 , Issue.1 , pp. 1-1
    • Liu, F.1    Mendel, J.M.2
  • 29
    • 68849106521 scopus 로고    scopus 로고
    • Enhanced karnik-mendel algorithms
    • Dec
    • D. Wu, J. M. Mendel, "Enhanced Karnik-Mendel Algorithms," in IEEE Trans. on Fuzzy Systems, vol. 17, no. 4, pp. 9123-934, Dec. 2008.
    • (2008) IEEE Trans. on Fuzzy Systems , vol.17 , Issue.4 , pp. 9123-9934
    • Wu, D.1    Mendel, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.