메뉴 건너뛰기




Volumn , Issue , 2012, Pages 3890-3894

Feasibility of using distal endpoints for In-room PET Range Verification of Proton Therapy

Author keywords

[No Author keywords available]

Indexed keywords

DOSE DELIVERY; HEAD AND NECK; MC SIMULATION; POSITRON EMISSION TOMOGRAPHY (PET); PROTON THERAPY; RANGE VERIFICATIONS; STANDARD DEVIATION; THRESHOLD ENERGY;

EID: 84881603256     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2012.6551892     Document Type: Conference Paper
Times cited : (1)

References (11)
  • 1
    • 34249320889 scopus 로고    scopus 로고
    • Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy
    • K. Parodi, H. Paganetti, H. A. Shih, et al, "Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy," Int. J. Rad. Oncol. Biol Phys., vol. 68, pp. 920-934, 2007.
    • (2007) Int. J. Rad. Oncol. Biol Phys. , vol.68 , pp. 920-934
    • Parodi, K.1    Paganetti, H.2    Shih, H.A.3
  • 2
    • 79960382081 scopus 로고    scopus 로고
    • Monitoring proton radiation therapy with in-room pet imaging
    • X. Zhu, S. Espana, J. Daartz, et al, "Monitoring proton radiation therapy with in-room pet imaging," Phys. Med. Biol., vol. 56, pp. 4041-4057, 2011.
    • (2011) Phys. Med. Biol. , vol.56 , pp. 4041-4057
    • Zhu, X.1    Espana, S.2    Daartz, J.3
  • 3
    • 44349190821 scopus 로고    scopus 로고
    • Comparison between in-beam and offline positron emission tomography imaging of proton and carbon ion therapeutic irradiation at synchrotron- and cyclotron-based facilities
    • K. Parodi, T. Bortfeld, and T. Haberer, "Comparison between in-beam and offline positron emission tomography imaging of proton and carbon ion therapeutic irradiation at synchrotron- and cyclotron-based facilities." Int. J. Rad. Oncol. Biol. Phys., vol. 71, pp. 945-956, 2008.
    • (2008) Int. J. Rad. Oncol. Biol. Phys. , vol.71 , pp. 945-956
    • Parodi, K.1    Bortfeld, T.2    Haberer, T.3
  • 4
    • 10744227644 scopus 로고    scopus 로고
    • Washout measurement of radioisotope implanted by radioactive beams in the rabbit
    • H. Mizuno, T. Tomitani, et al, "Washout measurement of radioisotope implanted by radioactive beams in the rabbit," Phys. Med. Biol., vol. 48, pp. 2269-2281, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , pp. 2269-2281
    • Mizuno, H.1    Tomitani, T.2
  • 5
    • 51849166983 scopus 로고    scopus 로고
    • Density heterogeneities and the influence of multiple coulomb and nuclear scatterings on the bragg peak distal edge of proton therapy beams
    • G. O. Sawakuchi, U. Titt, D. Mirkovic, and R. Mohan, "Density heterogeneities and the influence of multiple coulomb and nuclear scatterings on the bragg peak distal edge of proton therapy beams," Phys. Med. Biol., vol. 53, pp. 4605-4619, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4605-4619
    • Sawakuchi, G.O.1    Titt, U.2    Mirkovic, D.3    Mohan, R.4
  • 6
    • 0038377458 scopus 로고    scopus 로고
    • Geant4a simulation toolkit
    • S. Agostinelli et al, "Geant4a simulation toolkit," Nucl. Instrum. Methods A, vol. 506, pp. 250-303, 2003.
    • (2003) Nucl. Instrum. Methods A , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 7
    • 51849122521 scopus 로고    scopus 로고
    • Clinical implementation of full Monte Carlo dose calculation in proton beam therapy
    • H. Paganetti, K. P. H. Jiang, et al, "Clinical implementation of full monte carlo dose calculation in proton beam therapy," Phys. Med. Biol., vol. 53, pp. 4825-4853, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4825-4853
    • Paganetti, H.1    Jiang, K.P.H.2
  • 8
    • 0033983759 scopus 로고    scopus 로고
    • Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions
    • W. Schneider, T. Bortfeld, and W. Schlegel, "Correlation between CT numbers and tissue parameters needed for monte carlo simulations of clinical dose distributions," Phys. Med. Biol., vol. 45, pp. 459-478, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 459-478
    • Schneider, W.1    Bortfeld, T.2    Schlegel, W.3
  • 9
    • 79954592033 scopus 로고    scopus 로고
    • The reliability of proton-nuclear interaction cross-section data to predict proton-induced pet images in proton therapy
    • S. Espana, X. Zhu, J. Daartz, G. E. Fakhri, T. Bortfeld, and H. Paganetti, "The reliability of proton-nuclear interaction cross-section data to predict proton-induced pet images in proton therapy," Phys. Med. Biol., vol. 56, pp. 2687-2698, 2011.
    • (2011) Phys. Med. Biol. , vol.56 , pp. 2687-2698
    • Espana, S.1    Zhu, X.2    Daartz, J.3    Fakhri, G.E.4    Bortfeld, T.5    Paganetti, H.6
  • 10
    • 84861175702 scopus 로고    scopus 로고
    • Range uncertainties in proton therapy and the role of Monte Carlo simulations
    • H. Paganetti, "Range uncertainties in proton therapy and the role of monte carlo simulations," Phys. Med. Biol., vol. 57, pp. R99-R117, 2012.
    • (2012) Phys. Med. Biol. , vol.57
    • Paganetti, H.1
  • 11
    • 70349582700 scopus 로고    scopus 로고
    • Systematic analysis of biological and physical limitations of proton beam range verification with offline pet/ct scans
    • A. Knopf, K. Parodi, T. Bortfeld, H. A. Shih, and H. Paganetti, "Systematic analysis of biological and physical limitations of proton beam range verification with offline pet/ct scans," Phys. Med. Biol., vol. 54, pp. 4477-4495, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4477-4495
    • Knopf, A.1    Parodi, K.2    Bortfeld, T.3    Shih, H.A.4    Paganetti, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.